Maytag Water Heater HRE2930T User Manual

Series Nine  
ELECTRIC  
WATER HEATER  
USER’S GUIDE  
Model Numbers  
HRE2930T  
HRE3930T  
HRE2940L  
HRE3940L  
HRE2940S  
HRE3940S  
HRE2940T  
HRE3940T  
HRE2950S  
HRE3950S  
HRE2950T  
HRE3950T  
HRE2966T  
HRE3966T  
FOR POTABLE WATER  
HEATING ONLY  
GAMA certification applies to all residential  
electric water heaters with capacities of 20 to  
120 Gallons. Input rating of 12 Kw or less at a  
voltage no greater than 250 V.  
NOT SUITABLE FOR  
SPACE HEATING  
Caution:  
WARNING  
Read and Follow All  
Safety Rules and  
Operating Instructions  
Before First Use of  
This Product.  
READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE  
COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR  
OPERATING THIS WATER HEATER.  
Save this Manual for Future Reference.  
Printed in the U.S.A. 0104  
Part No. 66001711  
184741-000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Instructions (cont’d)  
WARNING  
WATER HEATERS EQUIPPED FOR ONE VOLTAGE  
ONLY: This water heater is equipped for one type  
voltage only. Check the rating plate near the bot-  
tom access panel for the correct voltage. DO NOT  
use this water heater with any voltage other than  
the one shown on the model rating plate. Failure to  
use the correct voltage can cause problems which  
can result in DEATH, SERIOUS BODILY INJURY, OR  
PROPERTY DAMAGE. If you have any questions or  
doubts consult your electric company.  
WARNING  
HYDROGEN GAS: Hydrogen gas can be produced in  
a hot water system that has not been used for a  
long period of time (generally two weeks or more).  
Hydrogen gas is extremely flammable and explo-  
sive. To prevent the possibility of injury under these  
conditions, we recommend the hot water faucet be  
opened for several minutes at the kitchen sink  
before any electrical appliances which are connect-  
ed to the hot water system are used (such as a dish-  
washer or washing machine). If hydrogen gas is pre-  
sent, there will probably be an unusual sound simi-  
lar to air escaping through the pipe as the hot  
water faucet is opened. There must be no smoking  
or open flame near the faucet at the time it is open.  
CAUTION  
WATER HEATERS EVENTUALLY LEAK: Installation of  
the water heater must be accomplished in such a  
manner that if the tank or any connections should  
leak, the flow of water will not cause damage to the  
structure. For this reason, it is not advisable to install  
the water heater in an attic or upper floor. When  
such locations cannot be avoided, a suitable drain  
pan should be installed under the water heater.  
Drain pans are available at your local hardware  
store. Such a drain pan must have a minimum diam-  
eter of at least 134 inches greater than the water  
heater diameter and must be piped to an adequate  
drain.  
CAUTION  
Never use this water heater unless it is completely  
full of water. To prevent damage to the tank and  
heating element, the tank must be filled with water.  
Water must flow from the hot water faucet before  
turning “ON” power.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Safety Instructions  
.....................................................................................................................................2,3  
Table of Contents...........................................................................................................................................4  
Customer Information............................................................................................................................5  
Product Specifications  
.............................................................................................................................6  
Accessories and Tools Needed  
....................................................................................................7  
Accessories............................................................................................................................................................................7  
Tools .....................................................................................................................................................................................7  
Instructions for Installation........................................................................................................8-17  
Removing the Old Water Heater..........................................................................................................................................8  
Locating the New Water Heater ..........................................................................................................................................9  
Typical Installation................................................................................................................................................................9  
The Convertible Lower Element........................................................................................................................................10  
Water Piping.......................................................................................................................................................................11  
T&P Valve and Pipe Insulation .......................................................................................................................................11  
Temperature-Pressure Relief Valve .....................................................................................................................................12  
Filling the Water Heater.....................................................................................................................................................13  
Converting the Lower Element.....................................................................................................................................13-15  
Wiring Diagrams................................................................................................................................................................16  
Wiring ................................................................................................................................................................................17  
Installation Checklist ..........................................................................................................................................................18  
Service and Maintenance  
............................................................................................................19-24  
Temperature Regulation......................................................................................................................................................19  
Thermostats........................................................................................................................................................................19  
Thermostat Settings............................................................................................................................................................19  
Thermostat Adjustment......................................................................................................................................................20  
Anode Rod Inspection........................................................................................................................................................20  
Temperature-Pressure Relief Valve Operation....................................................................................................................20  
Draining..............................................................................................................................................................................21  
Thermostat Removal/Replacement................................................................................................................................21,22  
Element Cleaning and Replacement .............................................................................................................................22-24  
Drain Valve Washer Replacement ......................................................................................................................................24  
Service.................................................................................................................................................................................24  
Troubleshooting  
......................................................................................................................................25-27  
Start Up Conditions............................................................................................................................................................25  
Thermal Expansion........................................................................................................................................................25  
Strange Sounds...............................................................................................................................................................25  
Operational Conditions ................................................................................................................................................25, 26  
Smelly Water..................................................................................................................................................................25  
Air in Hot Water Faucets...............................................................................................................................................25  
Rumbling Noise .............................................................................................................................................................25  
High Temperature Shut Off System........................................................................................................................25, 26  
Not Enough Hot Water.................................................................................................................................................26  
Water is Too Hot ...........................................................................................................................................................26  
Leakage Checkpoints.....................................................................................................................................................27  
Repair Parts List.......................................................................................................................................28-34  
Warranty....................................................................................................................................................................36  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customer Information  
NEC - National Electrical Code NFPA 70. This publica-  
tion is available from your local government or public  
library or electric company or by writing Underwriters  
Laboratories Inc., 333 Pfingsten Road, Northbrook, IL  
60062.  
Thank You  
for purchasing a Maytag water heater.  
Properly installed and maintained, it should give you years of  
trouble free service. It is strongly suggested that this new  
water heater be professionally installed, call Maytag Customer  
Service at 1-800-788-8899 for recommended installers.  
• If after reading this manual you have any questions or do  
not understand any portion of the instructions, call Maytag  
Customer Service at 1-800-788-8899 for an authorized  
servicer.  
Abbreviations Found In This Instruction Manual  
U.L. - Underwriters Laboratories Inc.  
NEC - National Electrical Code  
ANSI - American National Standards Institute  
• Carefully plan the place where you are going to put the  
water heater. Correct electrical wiring and connections are  
very important in preventing death from possible electrical  
shock and fires.  
Examine the location to ensure the water heater complies  
with the “Locating the New Water Heater” section.  
• Read the “Safety Instructions” section, pages 2 and 3 of this  
manual first and then the entire manual carefully. If you  
don’t follow the safety rules, the water heater will not oper-  
ate properly. It could cause DEATH, SERIOUS BODILY  
INJURY AND/OR PROPERTY DAMAGE.  
This manual contains instructions for the installation, oper-  
ation, and maintenance of this electric water heater. It also  
contains warnings throughout the manual that you must  
read and be aware of. All warnings and all instructions are  
essential to the proper operation of the water heater and  
your safety. Since we cannot put everything on the first few  
pages, READ THIS ENTIRE MANUAL BEFORE  
ATTEMPTING TO INSTALL OR OPERATE THE  
WATER HEATER.  
• For California installation this water heater must be braced,  
anchored, or strapped to avoid falling or moving during an  
earthquake. See instructions for correct installation proce-  
dures. Instructions may be obtained from the California  
office of the State Architect, 400 P Street, Sacramento, CA  
95814.  
• Massachusetts Code requires this water heater to be  
installed in accordance with Massachusetts 248-CMR 2.00:  
State Plumbing Code and 248-CMR 5.00.  
• The installation must conform with the instructions in this  
manual; electric company rules; and Local Codes, or in the  
absence of Local Codes, with the current edition of the  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Specifications  
Model  
HRE2930T  
HRE3930T  
HRE2940L  
HRE3940L  
HRE2940S  
HRE3940S  
HRE2940T  
HRE3940T  
Tank Capacity  
In Gallons  
30  
40  
40  
40  
Element  
Wattage  
Upper  
3800  
3800  
3800  
3800  
at 240 Volt  
Lower 3800  
Upper  
5500  
25  
3800  
5500  
3800  
5500  
3800  
5500  
Recovery Rate  
In Gals Per Hr.  
@ 90°F Rise  
17.3  
17.3  
17.3  
17.3  
Lower 17.3  
17.3  
25  
17.3  
25  
17.3  
25  
Diameter  
Height  
18  
25″  
201/2  
18″  
591/2  
461/2  
321/4  
44″  
Maximum Fuse or  
Circuit Breaker Size  
20  
12  
30  
10  
20  
12  
30  
10  
20  
12  
30  
10  
20  
12  
30  
10  
Minimum  
Wire Size (Gauge)  
Model  
HRE2950S  
HRE3950S  
HRE2950T  
HRE3950T  
HRE2966T  
HRE3966T  
Tank Capacity  
In Gallons  
50  
50  
66  
Element  
Wattage  
Upper  
3800  
3800  
3800  
at 240 Volt  
Lower 3800  
Upper  
5500  
25  
3800  
5500  
3800  
5500  
Recovery Rate  
In Gals Per Hr.  
@ 90°F Rise  
17.3  
17.3  
17.3  
Lower 17.3  
17.3  
25  
17.3  
25  
Diameter  
Height  
22″  
48″  
201/2  
22″  
601/4  
54″  
Maximum Fuse or  
Circuit Breaker Size  
20  
12  
30  
10  
20  
12  
30  
10  
20  
12  
30  
10  
*Minimum  
Wire Size (Gauge)  
*Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local  
electrical code.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories and Tools Needed  
Accessories  
To simplify the installation Maytag has available the installa-  
tion parts shown below. You may or may not need all of these  
accessories depending on your type of installation. Call  
Maytag Customer Service at 1-800-788-8899 for an autho-  
rized installer.  
DRAIN PANS AVAILABLE IN 22DIAMETER (PART  
NUMBER 66001011) FOR WATER HEATERS HAVING  
A DIAMETER 20OR LESS, 24” DIAMETER (PART  
NUMBER 66001105) FOR WATER HEATERS HAVING  
A DIAMETER 22” OR LESS AND AVAILABLE IN 28″  
DIAMETER (PART NUMBER 66001012) FOR WATER  
HEATERS HAVING A DIAMETER 26.25OR LESS  
EXPANSION TANKS FOR THERMAL EXPANSION  
CONDITIONS AVAILABLE IN 2 GALLON (PART  
NUMBER 66001013) AND 5 GALLON (PART  
NUMBER 66001014) CAPACITY  
ADDITIONAL TOOLS NEEDED  
WHEN SWEAT SOLDERING  
Tools  
You may or may not need all of these tools, depending on your  
type of installation. These tools can be purchased at your local  
Maytag store.  
Tubing Cutters or Hacksaw  
• Propane Torch  
• Soft Solder  
• Pipe Wrenches (2) 14″  
• Screwdriver  
• Solder Flux  
• Emery Cloth  
• 6 Foot Tape or Folding Rule  
• Garden Hose  
• Wire Brushes  
• Drill  
• Pipe dope or Teflon Tape  
HACKSAW  
6 FOOT TAPE  
GARDEN HOSE  
3/4WIRE BRUSH  
SLOT-HEAD SCREW DRIVER  
PIPE  
WRENCH  
1/2WIRE BRUSH  
PHILLIPS SCREWDRIVER  
PROPANE TORCH  
ROLL OF LEAD FREE  
SOFT SOLDER  
PIPE DOPE  
(SQUEEZE TUBE)  
SOLDER FLUX  
ROLL OF EMERY  
CLOTH  
TUBING CUTTER  
ROLL OF TEFLON TAPE  
(Use only on water connec-  
tions)  
DRILL  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation  
Removing the Old Water Heater  
Turn “OFF” electrical supply to the water heater.  
a. If you have copper piping to the water heater, the two  
copper water pipes can be cut with a hacksaw approxi-  
mately four inches away from where they connect to  
the water heater. This will avoid cutting off the pipes  
too short. Additional cuts can be made later if neces-  
sary. Disconnect the temperature-pressure relief valve  
drain line. When the water heater is drained, discon-  
nect the hose from the drain valve. Close the drain  
valve. The water heater is now completely disconnect-  
ed and ready to be removed.  
1
5
Turn “OFF” the water supply to the  
water heater at the water shutoff valve  
or water meter.  
2
2
5
1
4
Attach a hose to the water heater drain  
valve and put the other end in a floor  
drain or outdoors. Open the water  
heater drain valve. Open a nearby hot  
water faucet which will relieve pressure  
in the water heater and speed draining.  
3
b. If you have galvanized pipe to the water  
5
heater, loosen the two galvanized pipes  
with a pipe wrench at the union in each  
line. Also disconnect the piping remain-  
ing to the water heater. These pieces  
should be saved since they may be needed  
when reconnecting the new water heater.  
Disconnect the temperature-pressure  
relief valve discharge pipe. When the  
water heater is drained, disconnect the  
hose from the drain valve. Close the drain  
valve. The water heater is now completely  
disconnected and ready to be removed.  
WARNING  
The water passing out of the drain  
valve may be extremely hot. To  
avoid being scalded, make sure all  
connections are tight and that the  
water flow is directed away from  
any person.  
3
Check again to make sure the electrical supply is turned  
4
“OFF” to the water heater. Then disconnect the electri-  
cal supply connection from the water heater junction  
box.  
CAUTION  
Mineral buildup or sediment may have accumulated  
in the old water heater. This causes the water  
heater to be much heavier than normal and this  
residue, if spilled out, could cause staining.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Locating The New Water  
CAUTION  
WATER HEATERS EVENTUALLY LEAK: Installation of the  
Heater  
water heater must be accomplished in such a manner  
that if the tank or any connections should leak, the flow  
of water will not cause damage to the structure. For this  
reason, it is not advisable to install the water heater in  
an attic or upper floor. When such locations cannot be  
avoided, a suitable drain pan should be installed under  
the water heater. Drain pans are available at your local  
hardware store. Such a drain pan must have a minimum  
diameter of at least 134 inches greater than the water  
heater diameter and must be piped to an adequate  
drain.  
You should carefully choose an indoor location for the new  
water heater, because the placement is a very important con-  
sideration for the safety of the occupants in the building and  
for the most economical use of the appliance. This water  
heater is not intended for outdoor installation.  
Whether replacing an old water heater or putting the water  
heater in a new location, the following critical points must be  
observed.  
CAUTION  
INSTALLATION IN RESIDENTIAL GARAGES: The water  
heater must be located and/or protected so it is not  
subject to physical damage by a moving vehicle.  
1. The location selected should be indoors as close to and as  
centralized with the water piping system as possible. This  
water heater, as well as all water heaters, will eventually  
leak. Do not install without adequate drainage provisions  
where water flow will cause damage.  
2. The location selection must provide adequate clearances for  
servicing and proper operation of the water heater.  
VACUUM RELIEF REQUIRED BY SOME CODES  
(REFER TO LOCAL CODES)  
SHUTOFF VALVE  
HOT  
Typical Installation  
WATER  
COLD WATER INLET  
OUTLET  
CHECK ALL CONNECTIONS FOR LEAKS.  
CONSULT THE LOCAL UTILITY COMPANY TO EXAM-  
INE INSTALLATION FOR PROPRIETY AND SAFETY.  
ELBOW  
UNION  
UNION  
* WARNING  
3/4THREADED  
TEMPERED  
WATER  
CONNECTORS  
HOTTER WATER CAN SCALD: Water heaters are  
intended to produce hot water. Water heated to a  
temperature which will satisfy clothes washing,  
dish washing, and other sanitizing needs can scald  
and permanently injure you upon contact. Some  
people are more likely to be permanently injured by  
hot water than others. These include the elderly,  
children, the infirm, or physically/mentally handi-  
capped. If anyone using hot water in your home fits  
into one of these groups or if there is a local code or  
state law requiring a certain temperature water at  
the hot water tap, then you must take special pre-  
cautions. In addition to using the lowest possible  
temperature setting that satisfies your hot water  
needs, a means such as a mixing valve, should be  
used at the hot water taps used by these people or  
at the water heater. Mixing valves are available at  
plumbing supply or hardware stores. Follow manu-  
facturers instructions for installation of the valves.  
Before changing the factory setting on the thermo-  
stat, read the “Temperature Regulation” section in  
this manual.  
OUTLET  
*MIXING VALVE  
ELECTRICAL  
JUNCTION BOX  
TEMPERATURE-  
PRESSURE  
RELIEF VALVE  
ACCESS COVER  
ACCESS COVER  
DISCHARGE  
PIPE  
(Do not cap  
or plug)  
DRAIN VALVE  
6AIR GAP  
TO SUITABLE DRAIN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
The Convertible Lower  
Element  
The Upper Element, is a conventional 3800 watt element  
which only operates at its rated wattage on 240 volts. (See rat-  
ing plate on water heater).  
The Lower Element of the water heater can be converted  
from operation at 3800 watts to 5500 watts on a 240 volt  
system.  
Read and follow water heater warnings and instructions.If  
after reading these instructions in this manual, if you do not  
understand any portion, call Maytag Customer Service at 1-  
800-788-8899 for an authorized servicer.  
WARNING  
Before making the conversion to 5500 watts, check  
the (1) power supply…must be 240 volts, (2)  
wiring...10 gauge AWG @ Type TW, 60°C or equiva-  
lent, and (3) Circuit breakers or fusing…capable of  
30 amp loading. Also, the installation must conform  
with this manual, local codes and electric utility  
rules. Failure to comply can result in DEATH, SERI-  
OUS BODILY INJURY, OR PROPERTY DAMAGE.  
NOTE: Whether or not the element conversion is made the  
model rating plate must be marked. Using a hard point ink  
pen, check the appropriate block within the model rating  
plate, which is located adjacent to the lower access panel.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
2. Look at the top cover of the water heater. The cold water inlet  
is marked cold. Connect the cold water pipe to the cold water  
inlet of the water heater.  
Water Piping  
* WARNING  
NOTE: Your water heater is super insulated to minimize heat  
loss from the tank. Further reduction in heat loss can be accom-  
plished by insulating the hot water lines from the water heater.  
HOTTER WATER CAN SCALD: Water heaters are intend-  
ed to produce hot water. Water heated to a tempera-  
ture which will satisfy clothes washing, dish washing,  
and other sanitizing needs can scald and permanently  
injure you upon contact. Some people are more likely  
to be permanently injured by hot water than others.  
These include the elderly, children, the infirm, or physi-  
cally/mentally handicapped. If anyone using hot water  
in your home fits into one of these groups or if there is  
a local code or state law requiring a certain tempera-  
ture water at the hot water tap, then you must take  
special precautions. In addition to using the lowest pos-  
sible temperature setting that satisfies your hot water  
needs, a means such as a mixing valve, should be used  
at the hot water taps used by these people or at the  
water heater. Mixing valves are available at plumbing  
supply or hardware stores. Follow manufacturers  
instructions for installation of the valves. Before chang-  
ing the factory setting on the thermostat, read the  
Temperature Regulation” section in this manual.  
COLD INLET  
WATER LINE  
SHUT-OFF  
VALVE  
HOT OUTLET TO  
HOUSE  
THREADED TO  
SWEAT COUPLING  
THREADED TO  
SWEAT COUPLING  
3/4THREADED  
3/4THREADED  
NIPPLE  
NIPPLE  
HOT  
COLD  
TEMPERATURE-  
PRESSURE RELIEF  
VALVE  
*See illustration on page 9 for mixing valve usage.  
If a water heater is installed in a closed water supply system; such  
as one having a back-flow preventer, check valve, water meter  
with a check valve, etc. in the cold water supply; means shall be  
provided to control thermal expansion. Contact the local utility  
or call Maytag Customer Service at 1-800-788-8899 for an  
authorized servicer on how to control this situation.  
DISCHARGE PIPE  
(Do not cap or plug)  
NOTE: To protect against untimely corrosion of hot and cold  
water fittings, it is strongly recommended that di-electric  
unions or couplings be installed on this water heater when  
connected to copper pipe.  
6AIR GAP  
FLOOR DRAIN  
NOTE: The secondary anode rod/hot outlet nipple and the  
cold inlet nipple are packaged separately with the water heater.  
The above parts must be installed in the appropriate HOT  
and COLD water connection locations.  
T&P Valve and Pipe Insulation  
(on Selected Models)  
The illustration shows the attachment of the water piping to the  
water heater. The water heater is equipped with 34 inch water  
connections.  
Remove insulation for T&P Valve  
and pipe connections from carton.  
Fit pipe insulation over the  
NOTE: If using copper tubing, solder tubing to an adapter  
before attaching the adaptor to the cold water inlet connec-  
tion. Do not solder the cold water supply line directly to the  
cold water inlet. It will harm the dip tube and damage the tank.  
incoming cold water line and the  
hot water line. Make sure that the  
insulation is against the top cover of the heater.  
Fit T&P Valve insulation over valve. Make sure that the insula-  
tion does not interfere with the lever of the T&P valve.  
1. Look at the top cover of the water heater. The water outlet is  
marked hot. Connect the hot water pipe to the hot water out-  
let of the water heater.  
Secure all insulation using tape.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Temperature-Pressure Relief Valve  
WARNING  
WARNING  
At the time of manufacture this water heater was provided  
with a combination temperature-pressures relief valve cer-  
tified by a nationally recognized testing laboratory that  
maintains periodic inspection of production of listed equip-  
ment or materials, as meeting the requirements for Relief  
Valves and Automatic Gas Shutoff Devices for Hot Water  
Supply Systems, and the current edition of ANSI Z21.22 •  
CSA 4.4 and the code requirements of ASME. If replaced,  
the valve must meet the requirements of local codes, but  
not less than a combination temperature and pressure  
relief valve certified as meeting the requirements for Relief  
Valves and Automatic Gas Shutoff Devices for Hot Water  
Supply Systems, ANSI Z21.22 • CSA 4.4 by a nationally rec-  
ognized testing laboratory that maintains periodic inspec-  
tion of production of listed equipment or materials.  
The valve must be marked with a maximum set pressure  
not to exceed the marked hydrostatic working pressure of  
the water heater (150 lbs./sq. in.) and a discharge capacity  
not less than the water heater input rate as shown on the  
model rating plate. (Electric heaters - watts divided by  
1000 x 3412 equal BTU/Hr. rate.)  
The temperature-pressure relief valve must be manu-  
ally operated at least once a year. Caution should be  
taken to ensure that (1) no one is in front of or  
around the outlet of the temperature-pressure relief  
valve discharge line, and (2) the water manually dis-  
charged will not cause any bodily injury or property  
damage because the water may be extremely hot.  
If after manually operating the valve, it fails to com-  
pletely reset and continues to release water, immedi-  
ately close the cold water inlet to the water heater,  
follow the draining instructions, and replace the  
temperature-pressure relief valve with a new one.  
COLD  
HOT  
COLD  
HOT  
Your local jurisdictional authority, while mandating the use  
of a temperature-pressure relief valve complying with ANSI  
Z21.22 • CSA 4.4 and ASME, may require a valve model dif-  
ferent from the one furnished with the water heater.  
Compliance with such local requirements must be satisfied  
by the installer or end user of the water heater with a  
locally prescribed temperature-pressure relief valve  
installed in the designated opening in the water heater in  
place of the factory furnished valve.  
CONDUIT  
TEMPERATURE-  
PRESSURE  
RELIEF VALVE  
DISCHARGE PIPE  
(Do not cap or plug)  
For safe operation of the water heater, the relief valve  
must not be removed from it’s designated opening or  
plugged.  
The temperature-pressure relief valve must be installed  
directly into the fitting of the water heater designated for  
the relief valve. Position the valve downward and provide  
tubing so that any discharge will exit only within 6 inches  
above, or at any distance below the structural floor. Be cer-  
tain that no contact is made with any live electrical part.  
The discharge opening must not be blocked or reduced in  
size under any circumstances. Excessive length, over 30  
feet, or use of more than four elbows can cause restriction  
and reduce the discharge capacity of the valve.  
6AIR GAP  
FLOOR DRAIN  
WARNING “RELIEF VALVE OPENING”  
No valve or other obstruction is to be placed between the  
relief valve and the tank. Do not connect tubing directly to  
discharge drain unless a 6air gap is provided. To prevent  
bodily injury, hazard to life, or property damage, the relief  
valve must be allowed to discharge water in quantities  
should circumstances demand. If the discharge pipe is not  
connected to a drain or other suitable means, the water  
flow may cause property damage.  
This water heater is provided with a combination Temperature-Pressure Relief Valve listed as complying with  
the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANS Z21.22  
and the code requirements of ASME.  
Your local jurisdictional authority, while mandating the use of a Temperature-Pressure Relief Valve complying  
with ANS Z21.22 and ASME, may require a valve model different from the one furnished with the water heater.  
Compliance with such local requirements must be satisfied by the installer or end user of the water heater with  
a locally prescribed Temperature-Pressure Relief Valve installed in the designated opening in the water  
heater.  
TANK  
JACKET  
BRASS  
COUPLING  
TANK  
FITTING  
T&P RELIEF  
TEMPERATURE-  
PRESSURE  
RELIEF VALVE  
VALVE PROBE  
MUST EXTEND  
INTO TANK  
The Discharge Pipe:  
• Must not be smaller in size than the outlet pipe size of  
the valve, or have any reducing couplings or other  
restrictions.  
(13/8" x 3  
BRASS  
/4")  
T&P  
SHANK  
LENGTH  
NIPPLE  
• Must not be plugged or blocked.  
If a short shank (less than 2") temperature-pressure relief valve is to be installed  
(as shown), a nipple and coupling must be used.  
If a long shank (2" or longer) is to be installed, do not use the nipple and coupling.  
• Must be of material listed for hot water distribution.  
• Must be installed so as to allow complete drainage of  
both the temperature-pressure relief valve, and the dis-  
charge pipe.  
“Install Temperature-Pressure protective equipment required by local codes, but not less than a combina-  
tion Temperature-Pressure Relief Valve certified as meeting the requirements for Relief Valves and  
Automatic Gas Shutoff Devices for Hot-Water Supply Systems, ANS Z21.22 by a nationally recognized test-  
ing laboratory that maintains periodic inspection of production of listed equipment or materials. The valve  
must be oriented, provided with tubing, or otherwise installed so that discharge can exit only within 6 inches  
above, or at any distance below the structural floor, and cannot contact any live electrical part.”  
For safe operation of the water heater, the Relief Valve must not be removed or plugged.  
• Must terminate at an adequate drain.  
• Must not have any valve between the relief valve and  
tank.  
See manual heading - “Temperature-Pressure Relief Valve” for installation and maintenance of Relief  
Valve, discharge pipe and other safety precautions.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Filling the Water Heater  
To fill the water heater with water:  
1. Close the water heater drain valve by turning the handle to  
WARNING  
Before making the conversion to 5500 watts, check  
the right (clockwise). The drain valve is on the lower front  
of the water heater.  
2. Open the cold water supply valve to the water heater.  
NOTE: The cold water supply valve must be left open  
when the water heater is in use.  
3. To insure complete filling of the tank, allow air to exit by  
opening the nearest hot water faucet. Allow water to run  
until a constant flow is obtained. This will let air out of the  
water heater and the piping.  
the (1) power supply...must be 240 volts, (2)  
wiring...10 gauge AWG @ Type TW, 60°C or equiva-  
lent, and (3) Circuit breakers or fusing...capable of  
30 amp loading. Also, the installation must con-  
form with this Manual, local codes and electric utili-  
ty rules. FAILURE TO COMPLY CAN RESULT IN  
DEATH, SERIOUS BODILY INJURY OR PROPERTY  
DAMAGE.  
CAUTION  
Never use this water heater unless it is completely  
full of water. To prevent damage to the tank and  
heating element, the tank must be filled with  
water. Water must flow from the hot water faucet  
before turning “ON” power.  
4. Check all new water piping for leaks. Repair as needed.  
Converting the Lower  
Element  
These instructions only cover the conversion of the convert-  
ible element, read this entire manual before attempting to  
install or operate the water heater. The water heater is factory  
set to operate at 3800 watts. The lower element can be con-  
verted to operate at 5500 watts. Refer to “The Convertible  
Lower Element” section.  
NOTE: Whether or not the element conversion is made the  
model rating plate must be marked. Using a hard point ink  
pen, check the appropriate block within the model rating  
plate, which is located adjacent to the lower access panel.  
Necessary element conversion parts are located in a small bag  
contained within the large plastic manual envelope attached  
to the side of the water heater.  
The Upper Element is a conventional 3800 watt element  
which only operates at its rated wattage on 240 volts. (See rat-  
ing plate on water heater).  
The Lower Element of the water heater can be converted  
from operation at 3800 watts to 5500 watts on a 240 volt sys-  
tem.  
CONVERSION PARTS  
5500 W  
If after reading these instructions and this manual, if you do  
not understand any portion, call Maytag Customer Service at  
1-800-788-8899 for an authorized servicer.  
SCREW  
BUSS BAR  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Converting the Lower Element  
(cont’d)  
1. Before beginning the conversion turn “OFF” electric  
power supply to the water heater.  
4. Lift out the tab as shown to unclip the terminal cover from  
the thermostat. The terminal cover can now be removed from  
the thermostat.  
Lift out tab to unclip  
terminal cover from  
thermostat.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. FAILURE TO DO THIS COULD  
RESULT IN DEATH, SERIOUS BODILY INJURY, OR  
PROPERTY DAMAGE.  
2. The convertible element is located behind the lower access  
panel of the water heater. Remove the two screws securing  
the access panel, and remove panel.  
5. Remove the screws from terminal 2 of the element, and  
move the looped end of the wire aside.  
3. Remove the block of insulation and pad to expose the  
terminal cover.  
6. The buss bar is labeled 5500 W. Place the buss bar over ter-  
minals 2 and 3 with the 5500 W visible. Install the extra  
screw provided into terminal 3.  
5500 W  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Converting the Lower Element  
(cont’d)  
7. The wire removed from terminal 2 has a looped end. It  
must remain looped and now be placed (as shown) on top  
of the buss bar, over the opening of terminal 2, and secured  
using the remaining screw.  
11. Replace the access panel.  
8. Tighten terminals 2 and 3 to ensure proper electrical con-  
nection.  
12. Complete wiring to the water heater, or if completed,  
turn “ON” electric power to the water heater after filling  
the tank with water.  
WARNING  
Failure to tighten terminal screws can cause a fire  
which can result in DEATH, SERIOUS BODILY INJURY,  
OR PROPERTY DAMAGE.  
9. Replace the terminal cover on the thermostat making sure  
that the locking tabs on the terminal cover are in place.  
WARNING  
Make sure the thermostat is flush against the tank,  
the terminal cover is in place, and the insulation is  
replaced. Failure to do so can result in DEATH, SERI-  
OUS BODILY INJURY, OR PROPERTY DAMAGE.  
10. Place the insulation block and pad back in place so that it  
completely covers the thermostat and element.  
CAUTION  
Never use this water heater unless it is completely  
full of water. To prevent damage to the tank and  
heating element, the tank must be filled with water.  
Water must flow from the hot water faucet before  
turning “ON” power.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
TO ELECTRIC  
POWER SUPPLY  
Wiring Diagrams  
STANDARD WIRING FOR  
BLACK  
2 WIRE LEAD WATER HEATERS  
NON-SIMULTANEOUS OPERATION  
240 VOLT DOUBLE ELEMENT  
RED  
UPPER E.C.O. &  
THERMOSTAT  
UPPER  
ELEMENT  
LOWER  
HEATING ELEMENT  
WIRING FOR 3 WIRE LEAD WATER  
HEATERS NON-SIMULTANEOUS OPER-  
ATION 240 VOLT DOUBLE ELEMENT  
YELLOW  
UPPER  
HEATING ELEMENT  
LOWER  
HEATING ELEMENT  
*Note: Some Lower Hi-Temp Limit switches may have 4 terminals. Use only the 2 terminals on left.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Wiring  
C. Flexible metal conduit or 3 metallic tubing shall be permit-  
CAUTION  
ted for grounding if all the following conditions are met:  
1. The length in any ground return path does not exceed  
6 feet.  
2. The circuit conductors contained therein are protected  
by overcurrent devices rated at 20 amperes or less.  
3. The conduit or tubing is terminated in fittings  
approved for grounding.  
Never use this water heater unless it is completely  
full of water. To prevent damage to the tank and  
heating element, the tank must be filled with  
water. Water must flow from the hot water faucet  
before turning on power.  
You must provide all wiring of the proper size outside of the  
water heater. You must obey local codes and electric company  
requirements when you install this wiring.  
For complete grounding details and all allowable exceptions,  
refer to the current edition of the NEC - National Electrical  
Code NFPA 70.  
If you are not familiar with electric codes and practices, or if  
you have any doubt, even the slightest doubt, in your ability to  
connect the wiring to this water heater, obtain the service of a  
competent electrician. Call Maytag Customer Service at  
1-800-788-8899 for an authorized servicer.  
4. A standard 12conduit opening has been made in the water  
heater junction box for the conduit connection.  
5. Wiring Diagrams (See “Wiring Diagrams” Section) have  
been supplied showing the two most common types of con-  
nections between the water heater and the power supply.  
You can easily see which type connection you have by  
removing the junction box cover on top of the water heater.  
A. Two Wire Connection Diagrams: is the most common  
requiring you to simply connect red to red, black to black,  
and the ground wire to the green ground screw in the junc-  
tion box of the water heater.  
WARNING  
WATER HEATERS EQUIPPED FOR ONE VOLTAGE  
ONLY: This water heater is equipped for one type  
voltage only. Check the rating plate near the bot-  
tom access panel for the correct voltage. DO NOT  
use this water heater with any voltage other than  
the one shown on the model rating plate. Failure to  
use the correct voltage can cause problems which  
can result in DEATH, SERIOUS BODILY INJURY, OR  
PROPERTY DAMAGE. If you have any questions or  
doubts consult your electric company.  
B. Three Wire Connection Diagram: is used when you are  
connecting the water heater to power a supply that has a  
“Time Clock” or “Off Peak” Meter. To make these connec-  
tions refer to block 1 or 2 in this wiring diagram for the type  
of system you have.  
NOTE: If you have purchased a three wire connection  
water heater but you are not on a “Time Clock” or “Off  
Peak” meter and have a standard two wire connection  
power supply, simply follow the connection diagram in  
block 3 of the Three Wire Connection Diagram.  
CAUTION  
If wiring from your fuse box or circuit breaker box  
was aluminum for your old water heater, replace it  
with copper wire. If you wish to reuse the existing  
aluminum wire, have the connection at the water  
heater made by a competent electrician. Call  
Maytag Customer Service at 1-800-788-8899 for an  
authorized servicer.  
6. Use wire nuts and connect the power supply wiring to the  
wires inside the water heater’s junction.  
1. Provide a way to easily shut off the electric power when  
working on the water heater. This could be with a circuit  
breaker or fuse block in the entrance box or a separate dis-  
connect switch.  
7. The water heater must be electrically “grounded” by the  
installer. A green ground screw has been provided on the  
water heater's junction box. Connect ground wire to this  
location.  
2. Install and connect a circuit directly from the main fuse or  
circuit breaker box. This circuit must be the right size and  
have its own fuse or circuit breaker. Refer to the chart in  
the “Product Specifications” section for the correct size  
wire and fuse or circuit breaker.  
8. Replace the wiring junction cover using the screw provided.  
WIRE  
NUTS  
3. If metal conduit is used for the grounding conductor:  
A. The grounding electrode conductor shall be of copper,  
aluminum, or copperclad aluminum. The material shall  
be of one continuous length without a splice or joint.  
B. Rigid metal conduit, intermediate metal conduit, or  
electrical metallic tubing may be used for the grounding  
means if conduit or tubing is terminated in fittings  
approved for grounding.  
CONDUIT  
GREEN  
GROUND  
SCREW  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instructions for Installation (cont’d)  
Installation Checklist  
COLD  
HOT  
1. Whether or not the element conversion is made, the model  
rating plate must be marked. Using a hard point ink pen,  
check the appropriate block within the model rating plate,  
which is located adjacent to the lower access panel.  
2. Is the fuse or circuit breaker size correct as shown in the  
COLD  
HOT  
chart in the “Product Specifications” section?  
CONDUIT  
3. Are the wires from the circuit breaker or fuse service to the  
water heater’s junction box on the correct wire size (gauge) as  
shown in the chart in the “Product Specifications” section?  
TEMPERATURE-  
PRESSURE  
RELIEF VALVE  
4. Is the new temperature-pressure relief valve properly  
installed, and piped to an adequate drain? See  
Temperature-Pressure Relief Valve” in the “Instructions  
for Installation” section.  
DISCHARGE PIPE  
(Do not cap or  
plug)  
5. Is the water heater completely filled with water? See  
“Filling the Water Heater” instructions in the “Instructions  
for Installation” section.  
6. Will a water leak damage anything? See “Locating the  
New Water Heater” in the “Instructions for Installation”  
section.  
6AIR GAP  
7. Are the cold and hot water lines connected to the water  
heater correctly? See “Water Piping” instructions in the  
“Instructions for Installation” section.  
FLOOR DRAIN  
8. Is there adequate clearance for maintenance around the  
water heater?  
9. Do you need to call your electric company to check your  
wiring?  
MODEL RATING PLATE  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance  
Temperature Regulation  
WARNING  
LOWER THERMOSTAT  
WITH HIGH LIMIT  
HOTTER WATER CAN SCALD: Water heaters are  
intended to produce hot water. Water heated to a  
temperature which will satisfy clothes washing,  
dish washing, and other sanitizing needs can scald  
and permanently injure you upon contact. Some  
people are more likely to be permanently injured by  
hot water than others. These include the elderly,  
children, the infirm, or physically/mentally handi-  
capped. If anyone using hot water in your home fits  
into one of these groups or if there is a local code or  
state law requiring a certain temperature water at  
the hot water tap, then you must take special pre-  
cautions. In addition to using the lowest possible  
temperature setting that satisfies your hot water  
needs, a means such as a mixing valve, should be  
used at the hot water taps used by these people or  
at the water heater. Mixing valves are available at  
plumbing supply or hardware stores. Follow manu-  
facturers instructions for installation of the valves.  
Before changing the factory setting on the thermo-  
stat, read the “Temperature Regulation” section in  
this manual.  
LOWER THERMOSTAT  
WITHOUT HIGH LIMIT  
LOWER THERMOSTAT ADJUSTABLE  
BEHIND LOWER ACCESS PANEL  
Temperature Settings  
WARNING  
Never allow small children to use a hot water tap,  
or to draw their own bath water. Never leave a  
child or handicapped person unattended in a bath-  
tub or shower.  
HOT–Is a thermostat setting of approximately 120°F,  
which will supply hot water at the most eco-  
nomical temperatures.  
A–Is a thermostat setting of approximately 130°F.  
B–Is a thermostat setting of approximately 140°F.  
C–Is a thermostat setting of approximately 150°F.  
Thermostats  
The thermostats of this water heater have been factory set at a  
position which approximates 120°F (HOT) to reduce the risk  
of scald injury.  
VERY HOTIs a thermostat setting of approximately 160°F.  
It is recommended that the dial be set lower  
whenever possible.  
The upper and lower thermostats are factory set at a position  
which approximates 120°F (HOT) and are adjustable if a dif-  
ferent water temperature is desired. Read all warnings in this  
manual and on the water heater before proceeding.  
NOTE: Water temperature range of 120°–140°F recom-  
mended by most dishwasher manufacturers.  
Time to Produce  
2nd & 3rd Degree  
Temperature Setting  
Burns on Adult Skin  
About 1/2 seconds  
About 1-1/2 seconds  
Less than 5 seconds  
About 30 seconds  
160°F  
150°F  
140°F  
130°F  
120°F  
More than 5 minutes  
UPPER THERMOSTAT ADJUSTABLE  
BEHIND UPPER ACCESS PANEL  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance (cont’d)  
Thermostat Adjustments  
replaced more often than an anode rod that appears to be  
The upper and lower thermostats have been factory set at  
HOT (approximately 120°F) to reduce the risk of scald injury.  
intact. Replacement of a depleted anode rod can extend the  
life of your water heater. Inspection should be conducted by a  
qualified service technician, and at a minimum should be  
checked annually after the warranty period.  
The upper and lower thermostats are adjustable if a different  
water temperature is desired. Read all warnings in the  
Temperature Regulation” section before proceeding.  
NOTE: It is not necessary to adjust the upper thermostat.  
However, if it is adjusted above the factory set point of  
120°F (HOT) it is recommended that it not be set higher  
than the lower thermostat setting.  
Temperature-Pressure Relief  
Valve Operation  
The temperature-pressure relief valve must be manually oper-  
ated at least once a year.  
To adjust the temperature setting for both upper and lower  
thermostats, proceed as follows:  
TEMPERATURE-PRESSURE  
RELIEF VALVE  
1. Turn “OFF” the electric power to the water heater at the  
junction box.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
DISCHARGE PIPE  
WARNING  
The temperature-pressure relief valve must be  
manually operated at least once a year. Caution  
should be taken to ensure that (1) no one is in front  
of or around the outlet of the temperature-pres-  
sure relief valve discharge line, and (2) the water  
manually discharged will not cause any property  
damage or bodily injury. The water may be  
extremely hot.  
If after manually operating the valve, it fails to  
completely reset and continues to release water,  
immediately close the cold water inlet to the water  
heater, follow the draining instructions, and  
replace the temperature-pressure relief valve with  
a new one.  
2. Take off the access panel, insulation block and pad.  
3. The slotted adjustment (using a screwdriver) can be turned  
clockwise (  
) to increase the temperature setting or  
counter clockwise (  
setting.  
) to decrease the temperature  
4. Replace the insulation block, pad and access panel.  
5. Turn “ON” the power supply.  
Failure to install and maintain a new properly listed tempera-  
ture-pressure relief valve will release the manufacturer from  
any claim which might result from excessive temperature or  
pressure.  
Anode Rod Inspection  
The anode rod is used to protect the tank from corrosion.  
Most hot water tanks are equipped with an anode rod. The  
submerged rod sacrifices itself to protect the tank. Instead of  
corroding the tank, water ions attack and eat away the anode  
rod. This does not affect the water’s taste or color. The rod  
must be maintained to keep the tank in operating condition.  
WARNING  
If the temperature-pressure relief valve on the  
appliance weeps or discharges periodically, this  
may be due to thermal expansion. Your water  
heater may have a check valve installed in the  
water line or a water meter with a check valve. Call  
Maytag Customer Service at 1-800-788-8899 for an  
authorized servicer. Do not plug the temperature-  
pressure relief valve.  
Anode deterioration depends on water conductivity, not nec-  
essarily water condition. A corroded or pitted anode rod indi-  
cates high water conductivity and should be checked and/or  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance (cont’d)  
Draining  
Thermostat  
Removal/Replacement  
The water heater should be drained if being shut down during  
freezing temperatures. Also periodic draining and cleaning of  
sediment from the tank may be necessary.  
1. Turn “OFF” the electrical power to the water heater at the  
junction box.  
1. Before beginning turn “OFF” the electric power supply to  
the water heater.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
2. Remove the access panel and the insulation block and pad.  
3. Lift out the tab as shown below to unclip the terminal cover  
from the thermostat. The terminal cover can now be  
removed from the thermostat.  
2. CLOSE the cold water inlet valve to the water heater.  
3. OPEN a nearby hot water faucet and leave open to allow  
for draining.  
4. Connect a hose to the drain valve and terminate to an ade-  
quate drain or outdoors.  
Lift out tab to unclip  
terminal cover from  
thermostat.  
5. OPEN the water heater drain valve to allow for tank  
draining.  
NOTE: If the water heater is going to be shut down and  
drained for an extended period, the drain valve should be  
left open with hose connected allowing water to termi-  
nate to an adequate drain.  
6. Close the drain valve.  
7. Follow “Filling the Water Heater” instructions in the  
“Instructions for Installation” section.  
LOWER THERMOSTAT  
WITHOUT HIGH LIMIT  
UPPER OR LOWER  
THERMOSTAT WITH  
HIGH LIMIT  
8. Turn “ON” power to the water heater.  
4. Remove the two wires attached to the thermostat.  
CAUTION  
5. Remove the thermostat from behind the thermostat bracket.  
6. Disconnect wires from thermostat and slide out of the bracket.  
Never use this water heater unless it is completely  
full water. To prevent damage to the tank and heat-  
ing element, the tank must be filled with water.  
Water must flow from the hot water faucet before  
turning “ON” power.  
7. Place the new lower thermostat in the bracket making sure it  
fits firmly against the tank.  
8. Attach the wires to the new thermostat.  
NOTE: Some of the terminals may require straight-in  
wiring through an eye-opening. If wires are now looped, re-  
cut and strip wire 38to a straight length and insert.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance (cont’d)  
Thermostat Removal (cont’d)  
3. Attach a hose to the water heater drain valve and put the  
9. Put plastic terminal cover back in place.  
other end in a floor drain or outdoors. Open the water  
heater drain valve. Open a nearby hot water faucet which  
will relieve pressure in the water heater and speed draining.  
10. Replace the insulation block and pad to cover the thermostat.  
11. Replace access panel, then turn the electric power “ON”.  
Element Cleaning/  
Replacement  
NOTE: These instructions are written for element cleaning  
and element replacement for the lower element. If it is nec-  
essary to clean or replace the upper element, then repeat  
these instructions.  
WARNING  
The water passing out of the drain valve may be  
extremely hot. To avoid being scalded, make sure all  
connections are tight and that the water flow is  
directed away from any person.  
To remove the element from your tank in order to clean or  
replace it:  
4. Remove the two screws securing the access panel, and  
remove panel.  
1. Before beginning turn “OFF” the electric power supply to  
the water heater.  
WARNING  
5. Remove the block of insulation and pad to expose the  
terminal cover.  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
2. Turn off the water supply to the water heater at the water  
shutoff valve or water meter.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance (cont’d)  
6. Lift out the tab as shown to unclip the terminal cover from  
the thermostat. The terminal cover can now be removed  
from the thermostat.  
Lift out tab to unclip  
terminal cover from  
thermostat.  
11. Close the water heater drain valve by turning the handle  
to the right (clockwise). The drain valve is on the lower  
front of the water heater.  
12. Open the cold water supply valve to the water heater.  
NOTE: The cold water supply valve must be left open  
when the water heater is in use.  
13. To insure complete filling of the tank, allow air to exit by  
opening the nearest hot water faucet. Allow water to run  
until a constant flow is obtained. This will let air out of  
the water heater and the piping.  
LOWER THERMOSTAT  
WITHOUT HIGH LIMIT  
UPPER OR LOWER  
THERMOSTAT WITH  
HIGH LIMIT  
7. Disconnect the two wires on the element and unscrew the  
old element from the tank.  
CAUTION  
Never use this water heater unless it is completely  
full of water. To prevent damage to the tank and  
heating element, the tank must be filled with water.  
Water must flow from the hot water faucet before  
turning “ON” power.  
14. Check element for water leaks. If leakage occurs, tighten  
element or repeat steps 2 and 3, remove element and  
reposition gasket. Then repeat steps 10 through 14.  
15. Reconnect the two wires to the element and then check  
to make sure the thermostat remains firmly against the  
surface of the tank.  
8. Clean the area around the element opening. Remove any  
sediment from or around the element opening and inside  
the tank.  
9. If you are cleaning the element you have removed, do so  
by scraping or soaking in vinegar or a de-liming solution.  
WARNING  
Replacement elements must (1) be the same volt-  
age and (2) no greater wattage than listed on the  
model rating plate affixed to the water heater.  
10. A new gasket should be used in all cases to prevent a pos-  
sible water leak. (See Element Gasket in the Repair Parts  
Chart). Place the new element gasket on the thread side  
of the cleaned or new element and screw into tank, secur-  
ing tightly using an element wrench.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service and Maintenance (cont’d)  
Element Cleaning/  
Replacement (cont’d)  
Drain Valve Washer  
Replacement  
NOTE: For replacement, use a 1732x 1364x 18thick washer  
available at your nearest hardware store. For ordering a  
replacement washer, refer to the “Repair Parts” section.  
16. Replace the terminal cover on the thermostat making  
sure that the locking tabs on the terminal cover are in  
place.  
1. Before beginning turn “OFF” the electrical power supply  
to the water heater.  
Lift out tab to clip  
terminal cover to  
thermostat.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
2. Follow “Draining” instructions in the “Service and  
Maintenance” section.  
3. Turning counter clockwise, remove the hex cap below the  
screw handle.  
LOWER THERMOSTAT  
WITHOUT HIGH LIMIT  
UPPER OR LOWER  
THERMOSTAT WITH  
HIGH LIMIT  
4. Remove the washer and put the new one in place.  
5. Screw the handle and cap assembly back into the drain  
valve and retighten using a wrench. DO NOT OVER  
TIGHTEN.  
17. Place the insulation block and pad back in place so that it  
completely covers the thermostat and element.  
6. Follow “Filling the Water Heater” instructions in the  
“Instructions for Installation” section.  
7. Check for leaks.  
8. Turn “ON” electric power to the water heater.  
HANDLE AND  
CAP ASSEMBLY  
WASHER  
18. Replace access panel.  
19. Turn “ON” electric power to water heater.  
Service  
Before calling for repair service, read the “Start Up  
Conditions” and “Operational Conditions” found in the  
Troubleshooting” section of this manual.  
If a condition persists or you are uncertain about the opera-  
tion of the water heater, let a qualified person check it out.  
Call Maytag Customer Service at 1-800-788-8899.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Start Up Conditions  
Smelly water may be eliminated or reduced in some water heater  
models by replacing the anode(s) with one of less active material,  
and then chlorinating the water heater tank and all hot water  
lines. Call Maytag Customer Service at 1-800-788-8899 for an  
authorized servicer for further information concerning an Anode  
Replacement Kit #66001068 and this Chlorination Treatment.  
THERMAL EXPANSION  
Water supply systems may, because of such events as high line  
pressure, frequent cut-offs, the effects of water hammer  
among others, have installed devices such as pressure reducing  
valves, check valves, back flow preventers, etc...to control  
these types of problems. When these devices are not equipped  
with an internal by-pass, and no other measures are taken, the  
devices cause the water system to be closed. As water is heat-  
ed, it expands (thermal expansion) and closed systems do not  
allow for the expansion of heated water.  
If the smelly water persists after the anode replacement and chlo-  
rination treatment, we can only suggest that continuous chlorina-  
tion and filtering conditioning equipment be considered to elimi-  
nate the water problem.  
The water within the water heater tank expands as it is heated  
and increases the pressure of the water system. If the relieving  
point of the water heater's temperature-pressure relief valve is  
reached, the valve will relieve the excess pressure. The temper-  
ature-pressure relief valve is not intended for the constant  
relief of thermal expansion. This is an unacceptable condition  
and must be corrected.  
Do not remove the anode leaving the tank unprotected. By  
doing so, all warranty on the water heater tank is voided.  
“AIR” IN HOT WATER FAUCETS  
WARNING  
HYDROGEN GAS: Hydrogen gas can be produced in  
a hot water system that has not been used for a  
long period of time (generally two weeks or more).  
Hydrogen gas is extremely flammable and explo-  
sive. To prevent the possibility of injury under these  
conditions, we recommend the hot water faucet be  
opened for several minutes at the kitchen sink  
before any electrical appliances which are connect-  
ed to the hot water system are used (such as a dish-  
washer or washing machine). If hydrogen gas is pre-  
sent, there will probably be an unusual sound simi-  
lar to air escaping through the pipe as the hot  
water faucet is opened. There must be no smoking  
or open flame near the faucet at the time it is open.  
It is recommended that any devices installed which could create  
a closed system, have a by-pass and/or the system have an  
expansion tank to relieve the pressure built by thermal expan-  
sion in the water system. Expansion tanks are available for  
ordering through the Maytag Customer Service. Contact the  
local water supplier and/or call Maytag Customer Service at  
1-800-788-8899 for an authorized servicer for assistance in  
controlling these situations.  
STRANGE SOUNDS  
Possible noises due to expansion and contraction of some  
metal parts during periods of heat-up and cool-down do not  
represent harmful or dangerous conditions.  
RUMBLING NOISE  
In some water areas, scale or mineral deposits will build up on  
your heating elements. This buildup will cause a rumbling  
noise. Follow “Element Cleaning/Replacement” instructions  
to clean and replace the elements.  
Operational Conditions  
SMELLY WATER  
HIGH TEMPERATURE SHUT OFF SYSTEM  
In each glasslined water heater there is installed at least one anode  
rod (see parts section) for corrosion protection of the tank.  
Certain water conditions will cause a reaction between this rod  
and the water. The most common complaint associated with the  
anode rod is one of a “rotten egg smell”. This odor is derived from  
hydrogen sulfide gas dissolved in the water. The smell is the result  
of four factors which must all be present for the odor to develop:  
The water heater has a high limit shut off system with a reset  
button located on the thermostat.  
Follow the resetting instructions which refer to the high limit  
behind the access panel.  
NOTE: If your water heater is connected to an “OFF  
PEAK” clock, and uses the “3 wire lead” wiring diagram in  
the “Wiring Diagram” section, then the water heater will  
have a hi-limit on both the upper and lower thermostats.  
Follow the instructions to reset the hi-limit behind the  
upper and lower access panels.  
a. a concentration of sulfate in the supply water.  
b. little or no dissolved oxygen in the water.  
c. a sulfate reducing bacteria within the water heater. (This  
harmless bacteria is non-toxic to humans.)  
d. an excess of active hydrogen in the tank. This is caused by  
the corrosion protective action of the anode.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting (cont’d)  
NOT ENOUGH OR NO HOT WATER  
1. Before beginning, turn “OFF” electrical power supply to  
the water heater.  
1. In a new installation, the water heater may not be proper-  
ly connected. Make sure the cold water supply valve is  
open. Review and check piping installation. Make sure  
that the cold water line is connected to the cold water  
inlet to the water heater and the hot water line to the hot  
water outlet on the water heater.  
2. Make sure the electrical supply to your water heater is  
“ON”.  
3. Check for loose or blown fuses in your water heater cir-  
cuit. Circuit breakers weaken with age and may not han-  
dle their rated load and should be replaced.  
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before removing  
any access panels or servicing the water heater,  
make sure the electrical supply to the water heater  
is turned “OFF”. Failure to do this could result in  
DEATH, SERIOUS BODILY INJURY, OR PROPERTY  
DAMAGE.  
4. Make certain the disconnect switch, if used, is in the  
“ON” position.  
5. Check to see the electric service to your house has not  
been interrupted. If this is the case, contact the electric  
company.  
2. Remove the two screws securing the access panel and  
remove panel.  
3. Remove the insulation block and pad to expose the termi-  
nal cover.  
6. Are the thermostats set to the desired temperature? See  
Temperature Regulation” section.  
4. Reset the high limit by pushing in the red button marked  
“RESET”.  
7. If you had experienced very hot water and now no hot  
water, the problem may be due to the high temperature  
shut off system. See “High Temperature Shut Off  
System” in the “Troubleshooting” section.  
RESET BUTTON  
8. During very cold weather, the incoming water will also be  
colder and it will require a longer time to become heated.  
9. The hot water usage may exceed the capacity of the water  
heater. If so, wait for water heater to recover after abnor-  
mal demand. Also examine pipes and faucets for possible  
water leaks.  
5. Replace the insulation block and pad so that it completely  
covers the thermostat and element.  
10. If you can not determine the problem, then call the  
Maytag Service Department.  
6. Replace the access panel.  
WATER IS TOO HOT  
7. Turn “ON” electric power to the water heater.  
Adjust the thermostat to a lower setting. See the  
Temperature Regulation” section.  
CAUTION  
If the high limit must be reset again, call Maytag  
Customer Service at 1-800-788-8899 for an autho-  
rized servicer to find out why the high limit turned  
“OFF” the electric power.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting (cont’d)  
Leakage Checkpoints  
Use this guide to check a “Leaking” water heater. Many sus-  
pected “Leakers” are not leaking tanks. Often the source of  
the water can be found and corrected.  
CAUTION  
Read this manual first, then before checking the  
water heater make sure the electric supply has been  
turned “OFF”, and never turn the electric supply  
“ON” before the tank is completely full of water.  
If you are not thoroughly familiar with electric codes, the  
water heater, and safety practices, contact your local utility or  
call Maytag Customer Service at 1-800-788-8899 for an  
authorized servicer to check the water heater.  
A
*Condensation may be seen on pipes in humid weather  
or pipe connections may be leaking.  
A
B
*The primary anode rod may be leaking.  
B
A
Small amounts of water from temperature-pressure  
relief valve may be due to thermal expansion or high  
water pressure in your area.  
C
D
C
*The temperature-pressure relief valve may be leaking  
at the tank fitting.  
D
E
The elements may be leaking at the tank fitting.  
E
WARNING  
HAZARD OF ELECTRICAL SHOCK! Before  
removing any access panels or servicing the  
water heater, make sure the electrical supply  
to the water heater is turned “OFF”. Failure to  
do this could result in DEATH, SERIOUS BODI-  
LY INJURY, OR PROPERTY DAMAGE.  
Turn electrical power “OFF”, remove access panels,  
insulation blocks and pads. If leaking around ele-  
ments, follow proper draining instructions and  
remove element. Reposition or replace gasket on ele-  
ment. Place element into opening and tighten  
securely. Then follow “Filling the Water Heater”  
instructions in the “Installation Instructions” section.  
Water from drain valve may be due to the valve being  
opened slightly.  
F
E
G
H
*The drain valve may be leaking at the tank fitting.  
*Water in the water heater bottom or on the floor may  
be from condensation, loose connections or the  
temperature-pressure relief valve. DO NOT replace  
the water heater until a full inspection of all possible  
water sources is made and necessary corrective steps  
taken.  
G
H
F
Leakage from other appliances, water lines, or ground  
seepage should also be checked.  
*NOTE: To check where threaded portion enters  
tank, insert cotton swab between jacket opening  
and fitting. If cotton is wet, follow “Draining”  
instructions in the “Service and Maintenance” sec-  
tion and then remove fitting. Put pipe dope or  
teflon tape on the threads and replace. Then follow  
“Filling the Water Heater” instructions in the  
“Instructions for Installation” section.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2930T  
HRE3930T  
HRE2940S  
HRE3940S  
HRE2940T  
HRE3940T  
30 GALLON  
30 GALLON  
40 GALLON  
40 GALLON  
40 GALLON  
40 GALLON  
NOTE:  
UPPER ELEMENT: These water heaters are equipped  
with 3800 watt elements.  
LOWER ELEMENT: These water heaters are equipped  
with factory installed convertible elements, which can be  
operated at 3800 watts or 5500 watts. Convertible elements  
are not offered as replacement parts.  
If a replacement 3800 watt, 240 volt element is needed,  
order part no. 66001106 replacement element. If, at the time  
of installation, the water heater was converted to operate at  
5500 watts, order part number 66001107 replacement ele-  
ment. (See model rating plate “If Converted” box).  
22  
21  
20  
23  
3
1
19  
2
18  
9
15  
17  
16  
8
6
4
10  
9
7
5
11  
14  
12  
13  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2930T  
HRE3930T  
HRE2940S  
HRE3940S  
HRE2940T  
HRE3940T  
30 GALLON  
30 GALLON  
40 GALLON  
40 GALLON  
40 GALLON  
40 GALLON  
MODEL NUMBERS  
HRE2930T HRE3930T HRE2940S HRE3940S HRE2940T HRE3940T  
PART NUMBERS  
KEY PART  
NO. DESCRIPTION  
1
Temperature-Pressure Relief Valve 66001700 66001700  
66001700 66001700 66001700 66001700  
66001709 66001709 66001709 66001709  
66001728 66001728 66001701 66001701  
66001015 66001015 66001015 66001015  
66001021 66001021 66001021 66001021  
2
3
4
5
T&P Insulation  
Dip Tube  
66001709 66001709  
66001544 66001544  
66001015 66001015  
66001021 66001021  
Drain Valve  
Drain Valve Washer  
1732x 1364x 1  
8thick)*  
6
7
8
Element Gasket  
Lower Element  
Buss Bar Kit  
66001053 66001053  
66001053 66001053 66001053 66001053  
SEE NOTE ON PAGE 28  
66001055 66001055 66001055 66001055  
66001054 66001054 66001054 66001054  
66001055 66001055  
66001054 66001054  
9
Thermostat Bracket  
10  
2 Pole Thermostat  
(Two Wire Lead Models)†  
66001007  
66001007  
66001007  
11  
12  
Terminal Cover (Lower)  
Lower Thermostat w/Hi Limit  
(Three Wire Lead Models)†  
66001268  
66001268  
66001268  
66001008  
66001008  
66001008  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
#
Terminal Cover (Lower Three Wire)  
Lower Access Panel  
Upper Access Panel  
Terminal Cover (Upper)  
Upper Thermostat w/Hi Limit  
Upper Element  
Element Gasket  
Primary Anode  
Secondary Anode/Nipple w/Heat Traps 66001716 66001716  
66001272  
66001272  
66001272  
66001703 66001703  
66001703 66001703  
66001064 66001064  
66001009 66001009  
66001703 66001703 66001703 66001703  
66001703 66001703 66001703 66001703  
66001064 66001064 66001064 66001064  
66001009 66001009 66001009 66001009  
SEE NOTE ON PAGE 28  
66001053 66001053 66001053 66001053  
66001725 66001725 66001111 66001111  
66001720 66001720 66001717 66001717  
66001705 66001705 66001705 66001705  
66001708 66001708 66001708 66001708  
66001711  
66001053 66001053  
66001252 66001252  
Nipple w/Heat Traps  
Pipe Insulation  
Manual  
66001704 66001704  
66001708 66001708  
*Also available at most hardware stores.  
†Refer to Wiring Diagram Section for verification.  
#Not Illustrated  
Now that you have purchased this water heater, should a  
need ever exist for repair parts or service, simply call Maytag  
Customer Service at 1-800-788-8899 for an authorized ser-  
vicer. Be sure to provide all pertinent facts when you call or  
visit.  
The model number of the water heater will be found on the  
model rating plate located above the access panel.  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE  
THE FOLLOWING INFORMATION:  
Model Number  
Serial Number  
Part Description  
Part Number  
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2940L  
HRE3940L  
40 GALLON  
40 GALLON  
NOTE:  
UPPER ELEMENT: These water heaters are equipped  
with 3800 watt elements.  
LOWER ELEMENT: These water heaters are equipped  
with factory installed convertible elements, which can be  
operated at 3800 watts or 5500 watts. Convertible elements  
are not offered as replacement parts.  
If a replacement 3800 watt, 240 volt element is needed,  
order part no. 66001106 replacement element. If, at the time  
of installation, the water heater was converted to operate at  
5500 watts, order part number 66001107 replacement ele-  
ment. (See model rating plate “If Converted” box).  
22  
21  
20  
23  
3
1
19  
2
18  
15  
9
17  
16  
8
6
10  
7
5
9
4
11  
14  
12  
13  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2940L  
HRE3940L  
40 GALLON  
40 GALLON  
MODEL NUMBERS  
HRE2940L HRE3940L  
PART NUMBERS  
KEY PART  
NO. DESCRIPTION  
1
2
3
4
5
Temperature-Pressure Relief Valve 66001682 66001682  
T&P Insulation  
Dip Tube  
66001709 66001709  
66001722 66001722  
66001015 66001015  
66001021 66001021  
Drain Valve  
Drain Valve Washer  
1732x 1364x 1  
8thick)*  
6
7
8
9
10  
Element Gasket  
Lower Element  
Buss Bar Kit  
Thermostat Bracket  
2 Pole Thermostat  
(Two Wire Lead Models)†  
Terminal Cover (Lower)  
Lower Thermostat w/Hi Limit  
(Three Wire Lead Models)†  
66001053 66001053  
SEE NOTE ON PAGE 30  
66001055 66001055  
66001054 66001054  
66001007  
11  
12  
66001268  
66001008  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
#
Terminal Cover (Lower Three Wire)  
Lower Access Panel  
Upper Access Panel  
Terminal Cover (Upper)  
Upper Thermostat w/Hi Limit  
Upper Element  
Element Gasket  
Primary Anode  
Secondary Anode/Nipple w/Heat Traps 66001720 66001720  
66001272  
66001703 66001703  
66001703 66001703  
66001064 66001064  
66001009 66001009  
SEE NOTE ON PAGE 30  
66001053 66001053  
66001723 66001723  
Nipple w/Heat Traps  
Pipe Insulation  
Manual  
66001705 66001705  
66001708 66001708  
66001711  
*Also available at most hardware stores.  
†Refer to Wiring Diagram Section for verification.  
#Not Illustrated  
The model number of the water heater will be found on the  
model rating plate located above the access panel.  
Now that you have purchased this water heater, should a  
need ever exist for repair parts or service, simply call Maytag  
Customer Service at 1-800-788-8899 for an authorized ser-  
vicer. Be sure to provide all pertinent facts when you call or  
visit.  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE  
THE FOLLOWING INFORMATION:  
Model Number  
Serial Number  
Part Description  
Part Number  
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2950S  
HRE3950S  
HRE2950T  
HRE3950T  
HRE2966T  
HRE3966T  
50 GALLON  
50 GALLON  
50 GALLON  
50 GALLON  
66 GALLON  
66 GALLON  
NOTE:  
UPPER ELEMENT: These water heaters are equipped  
with 3800 watt elements.  
LOWER ELEMENT: These water heaters are equipped  
with factory installed convertible elements, which can be  
operated at 3800 watts or 5500 watts. Convertible elements  
are not offered as replacement parts.  
If a replacement 3800 watt, 240 volt element is needed,  
order part no. 66001106 replacement element. If, at the time  
of installation, the water heater was converted to operate at  
5500 watts, order part number 66001107 replacement ele-  
ment. (See model rating plate “If Converted” box).  
22  
21  
20  
23  
3
1
19  
2
18  
15  
9
17  
16  
8
6
10  
9
7
5
4
11  
14  
12  
13  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MODEL NUMBERS  
HRE2950S  
HRE3950S  
HRE2950T  
HRE3950T  
HRE2966T  
HRE3966T  
50 GALLON  
50 GALLON  
50 GALLON  
50 GALLON  
66 GALLON  
66 GALLON  
MODEL NUMBERS  
HRE2950S HRE3950S HRE2950T HRE3950T HRE2966T HRE3966T  
PART NUMBERS  
KEY PART  
NO. DESCRIPTION  
1
Temperature-Pressure Relief Valve 66001700 66001700  
66001700 66001700 66001700 66001700  
2
3
4
5
T&P Insulation  
Dip Tube  
Drain Valve  
66001709 66001709  
66001544 66001544  
66001015 66001015  
66001021 66001021  
66001702 66001702 66001702 66001702  
66001015 66001015 66001015 66001015  
66001021 66001021 66001021 66001021  
Drain Valve Washer  
1732x 1364x 1  
8thick)*  
6
7
8
Element Gasket  
Lower Element  
Buss Bar Kit  
66001053 66001053  
66001053 66001053 66001053 66001053  
SEE NOTE ON PAGE 32  
66001055 66001055 66001055 66001055  
66001054 66001054 66001054 66001054  
66001055 66001055  
66001054 66001054  
9
Thermostat Bracket  
10  
2 Pole Thermostat  
(Two Wire Lead Models)†  
66001007  
66001007  
66001007  
11  
12  
Terminal Cover (Lower)  
Lower Thermostat w/Hi Limit  
(Three Wire Lead Models)†  
66001268  
66001268  
66001268  
66001008  
66001008  
66001008  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
#
Terminal Cover (Lower Three Wire)  
Lower Access Panel  
Upper Access Panel  
Terminal Cover (Upper)  
Upper Thermostat w/Hi Limit  
Upper Element  
Element Gasket  
Primary Anode  
Secondary Anode/Nipple w/Heat Traps 66001217 66001217  
66001272  
66001272  
66001272  
66001703 66001703  
66001703 66001703  
66001064 66001064  
66001009 66001009  
66001703 66001703 66001703 66001703  
66001703 66001703 66001703 66001703  
66001064 66001064 66001064 66001064  
66001009 66001009 66001009 66001009  
SEE NOTE ON PAGE 32  
66001053 66001053 66001053 66001053  
66001727 66001727 66001733 66001733  
66001720 66001720 66001217 66001217  
66001705 66001705 66001707 66001707  
66001709 66001709 66001709 66001709  
66001711  
66001053 66001053  
66001726 66001726  
Nipple w/Heat Traps  
Pipe Insulation  
Manual  
66001707 66001707  
66001709 66001709  
*Also available at most hardware stores.  
†Refer to Wiring Diagram Section for verification.  
#Not Illustrated  
The model number of the water heater will be found on the  
model rating plate located above the access panel.  
Now that you have purchased this water heater, should a  
need ever exist for repair parts or service, simply call Maytag  
Customer Service at 1-800-788-8899 for an authorized ser-  
vicer. Be sure to provide all pertinent facts when you call or  
visit.  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE  
THE FOLLOWING INFORMATION:  
Model Number  
Serial Number  
Part Description  
Part Number  
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts List (cont’d)  
MAYTAG ELECTRIC WATER HEATERS  
MAYTAG/STATE  
PART NUMBER CONVERSION KEY  
MAYTAG  
66001007  
66001008  
66001009  
66001011  
66001012  
66001013  
66001014  
66001015  
66001021  
66001053  
66001054  
66001055  
66001064  
66001068  
66001105  
66001106  
66001107  
66001111  
66001252  
66001268  
66001272  
66001544  
66001682  
66001700  
66001701  
66001702  
66001703  
66001704  
66001705  
66001707  
66001708  
66001709  
66001711  
66001716  
66001717  
66001720  
66001722  
66001723  
66001725  
66001726  
66001727  
66001728  
66001733  
STATE  
9002437  
9002436  
9002435  
9001609  
9001608  
ETC2X  
ETC5X  
9002401  
9001584  
9000308  
9000309  
9001591  
9002438  
9001453  
9002769  
9000225  
9000396  
9001672  
9001834  
9002276  
9002303  
9003501  
9003741  
9003917  
9003929  
9003919  
9003900  
9003915  
9003719  
9003909  
9003717  
9003716  
184741-000  
9003963  
9003964  
9003967  
9003926  
9003922  
9003487  
9003927  
9003928  
9003979  
9003729  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
FULL ONE YEAR WARRANTY  
For One Year from the date of Original Retail Purchase, any part which fails in normal home use will be repaired or  
replaced free of charge.  
If a leak occurs in the Tank, a new water heater of the closest capacity and quality then available, will be replaced free  
of charge.  
The warranty of the replacement is the balance of the original water heater’s Warranty.  
LIMITED PARTS WARRANTY  
After the First year and through the Ninth Year from the date of Original Retail Purchase, any Parts which fail due  
to a defect in materials or workmanship, will be replaced or repaired free of charge for the part itself, with the owner  
paying all other costs, including labor, mileage and transportation.  
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty cov-  
erage for parts that are proved to be defective in material or workmanship is effective for one year from the date of  
the Original Retail Purchase.  
The warranty of the replacement is the balance of the original water heater’s Warranty, or twelve months from the  
date of the part(s) purchase, whichever comes first.  
The warranty is limited to the original owner of the water heater.  
LIMITED TANK WARRANTY AGAINST LEAKS  
After the First Year and through the Ninth Year from the date of Original Retail Purchase, if a leak occurs in the  
Tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge for the  
water heater, with the owner paying all other costs, including labor, mileage and transportation.  
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above warranty cov-  
erage for tanks that are proven to be defective in material or workmanship is effective for two years from the date of  
the Original Retail Purchase.  
The warranty of the replacement is the balance of the original water heater’s Warranty.  
Please note: The Full and Limited Warranty applies only while this water heater is used in the United States of America.  
The warranty is limited to the original owner of the water heater.  
TO RECEIVE WARRANTY SERVICE  
To locate an authorized service company in your area contact the Maytag dealer from whom your appliance was pur-  
chased; or call Maytag Customer Service at the number listed below. Should you not receive satisfactory warranty  
service, please call or write:  
Maytag Customer Service  
P. O. Box 2370  
Cleveland, TN 37320-2370  
U.S.A. 1-800-788-8899  
When contacting Maytag Customer Service be sure to provide the Model and Serial Number of your appliance, The  
Name and Address of the Dealer from whom you purchased the appliance and the Date of Purchase.  
MAYTAG WATER HEATERS ARE MANUFACTURED AND THIS WARRANTY PROVIDED BY  
STATE INDUSTRIES, INC., ASHLAND CITY, TN. MAYTAG IS A TRADEMARK OF MAYTAG COR-  
PORATION AND IS USED UNDER LICENSE TO STATE INDUSTRIES, INC.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

LA Audio Electronic Microphone MS424 User Manual
Lenovo Computer Hardware 3656 User Manual
Lifebreath Thermostat 40DHWDFT User Manual
Logitech Mouse M310 User Manual
Mackie Speaker System ART400A User Manual
Magnasonic DVD VCR Combo DVD833 2 User Manual
Magnasonic Flat Panel Television 14611MHD User Manual
Maytag Dishwasher 8269550 User Manual
Metabo Welding System TIG 170 AC DC User Manual
Micon Security Camera IP 220E User Manual