29" Electric Dryer Installation Instructions
PRODUCT MODEL NUMBERS
MEDC200X, MEDC300X
OVERALL DIMENSIONS
Dryer dimensions
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if speci-
fied on the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended. Connect to
an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Water (Steam models only): The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
4"
C
B
(102 mm)
A
2½"
(64 mm)
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
4"
(102 mm)
A. Louvered hood
B. Box hood
4"
(102 mm)
Minimum Required Spacing
C. Angled hood (acceptable)
3"*
(76 mm)
The Vent system chart provides venting requirements
that will help achieve best drying performance.
14" max.*
(356 mm)
2
48 in.
*
2
(310 cm )
18"*
(457 mm)
NOTE: Side and bottom exhaust installation have a 90°
turn inside the dryer. To determine maximum exhaust
length, add a 90° turn to the total number of elbows
when referemcing the chart.
2
*
3"*
(76 mm)
24 in.
(155 cm )2
Vent system chart
29"
(737 mm)
1"
(25 mm)
27¾"
(705 mm)
Number of
90° elbows
Type
Box/louvered
Angled
hoods
1"
1"*
of vent
hoods
(25 mm) (25 mm)
B
C
A
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
0
1
2
3
A. Recessed area
Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
B. Side view - closet or confined area
C. Closet door with vents
Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
Rigid metal 35 ft. (10.7 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
Rigid metal 27 ft. (8.2 m)
4
Do not use vent runs longer than specified in vent
length chart.
Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Determine the number of elbows you will need.
Select the route that will provide the straightest and
most direct path outdoors.
Plan the installation to use the fewest number of elbows
and turns.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10096987