		 R 
					PORTABLE   
					FORCED   
					AIR HEATERS   
					OWNER’S MANUAL   
					100 SIDE   
					PV 002   
					150 SIDE HANDLE   
					PFA/PV 005   
					Heater Sizes: 70,000 100,000 150,000 BTU/Hr   
					IMPORTANT   
					Read and understand this manual before assembling, starting or servicing   
					heater. Improper use of heater can cause serious injury. Keep this manual   
					for future reference.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SAFETY   
					INFORMATION   
					! 
					WARNINGS   
					IMPORTANT: Read this owner’s manual carefully and completely   
					before trying to assemble, operate, or service this heater. Improper   
					use of this heater can cause serious injury or death from burns, fire,   
					explosion, electrical shock, and carbon monoxide poisoning.   
					! 
					DANGER   
					Carbon monoxide poisoning may lead to death!   
					Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning   
					resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the   
					heater may not be working properly. Get fresh air at once! Have heater serviced.   
					Some people are more affected by carbon monoxide than others. These include   
					pregnant women, persons with heart or lung disease or anemia, those under the   
					influence of alcohol, and those at high altitudes.   
					Make certain you read and understand all warnings. Keep this manual for   
					reference. It is your guide to safe and proper operation of this heater.   
					• Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never   
					use gasoline, naphtha, paint thinners, alcohol, or other highly flammable   
					fuels.   
					• Never use heater where gasoline, paint thinner, or other highly flammable   
					vapors are present.   
					• Follow all local ordinances and codes when using heater.   
					• Use only in well-vented areas. Provide at least a three-square-foot (2800   
					square cm) opening of fresh, outside air for each 100,000 BTU/Hr of rating.   
					• Use only in places free of flammable vapors or high dust content.   
					• Use only with the electrical voltage and frequency specified on model plate.   
					• Use only a three-wire, grounded (earthed) extension cord.   
					• Minimum heater clearances from combustibles:   
					Outlet: 8 Ft. (250 cm)   
					Sides, Top, and Rear: 4 Ft. (125 cm)   
					• Locate heater on a stable and level surface while hot or running or a fire may   
					occur.   
					• When moving or storing heater, keep heater in a level position or fuel   
					spillage may occur.   
					• Keep children and animals away from heater.   
					• Unplug heater when not in use.   
					• When used with thermostat, heater may start anytime.   
					• Never use heater in living or sleeping areas.   
					• Never block air inlet (rear) or air outlet (front) of heater.   
					• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.   
					• Never attach duct work to front or rear of heater.   
					3 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Hot Air Outlet   
					Upper Shell   
					Handle   
					PRODUCT   
					IDENTIFICATION   
					Fan Guard   
					Lower Shell   
					Fuel Tank   
					Side Cover   
					Air Filter   
					End Cover   
					Fuel Cap   
					Flame-Out   
					Control Reset   
					Button   
					Power Cord   
					35/50/70,000 BTU/HR DOMESTIC   
					PFA/PV 042   
					Figure 1 - 70,000 BTU/Hr Model   
					Hot Air   
					Outlet   
					Upper Shell   
					Lower   
					Shell   
					Fuel Cap   
					Fan Guard   
					Fuel Tank   
					Side Cover   
					Power Cord   
					Flame-Out Control   
					Reset Button   
					Hot Air   
					Outlet   
					Figure 2 - 100,000 BTU/Hr Model   
					Upper Shell   
					Lower   
					Shell   
					Fan Guard   
					Fuel   
					Tank   
					Fuel Cap   
					Slide Cover   
					Power Cord   
					Flame-Out   
					Control Reset   
					Button   
					Figure 3 - 150,000 BTU/Hr Model   
					4 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				1. Remove all packing items applied to heater for shipment.   
					2. Remove all items from carton.   
					3. Check items for any shipping damage. If heater is damaged, promptly inform   
					dealer where you bought heater.   
					UNPACKING   
					ASSEMBLY   
					These models are furnished with wheels and handles. Wheels, handles, and the   
					mounting hardware are found in the shipping carton.   
					(For 100,000 and 150,000   
					BTU/Hr Models Only)   
					Tools Needed   
					• Medium Phillips Screwdriver   
					• 3/8" Open or Adjustable Wrench   
					• Hammer   
					1. Slide axle through wheel support frame. Install wheels on axle.   
					IMPORTANT: When installing wheels, point extended hub of wheels toward   
					wheel support frame (see Figure 4).   
					2. Place cap nuts on axle ends. Gently tap with hammer to secure.   
					3. Place heater on wheel support frame. Make sure air inlet end (rear) of heater is   
					over wheels. Line up holes on fuel tank flange with holes on wheel support   
					frame.   
					4. Place front handle and rear handle on top of fuel tank flange. Insert screws   
					through handles, fuel tank flange, and wheel support frame. Attach nut finger   
					tight after each screw is inserted.   
					5. After all screws are inserted, tighten nuts firmly.   
					Front   
					Handle   
					Rear   
					Handle   
					Screw   
					Hot Air   
					Outlet   
					Air   
					Inlet   
					Fuel   
					Tank   
					Flange   
					Wheel   
					Support   
					Frame   
					Wheel   
					Nut   
					Extended   
					Hub   
					Cap Nut   
					Axle   
					Figure 4 - Wheel and Handle Assembly,100/150,000 BTU/Hr Models Only   
					5 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				The Fuel System: The air pump forces air through the air line. The air is then   
					pushed through the burner head nozzle. This air causes fuel to lift from the tank. A   
					fine mist of fuel is sprayed into the combustion chamber.   
					THEORY OF   
					OPERATION   
					The Air System: The motor turns the fan. The fan pushes air into and around   
					the combustion chamber. This air is heated and provides a stream of clean, hot air.   
					The Ignition System: The electronic ignitor sends voltage to the spark plug.   
					The spark plug ignites the fuel and air mixture.   
					The Flame-Out Control System: This system causes the heater to shut down   
					if the flame goes out.   
					Motor   
					Fan   
					Air Pump   
					Combustion   
					Chamber   
					Spark   
					Plug   
					Intake   
					Air   
					Filter   
					Burner   
					Head   
					Clean   
					Heated   
					Air Out   
					Cool   
					Air   
					In   
					Output   
					Air   
					Filter   
					Fuel   
					Tank   
					Fuel   
					Filter   
					Nozzle   
					Air line   
					To Burner   
					Electronic   
					Ignitor   
					Air For Fuel   
					System   
					Air For Combustion   
					And Heating   
					Fuel   
					FigTuHrEeOR5Y-CCUTrAoWsAsY Section OperPaFtAio/OnVa0l03View   
					FUELS   
					WARNING   
					Use only kerosene or No. 1 fuel oil to avoid risk of fire or   
					explosion. Never use gasoline, naphtha, paint thinners,   
					alcohol or other highly flammable fuels.   
					Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels   
					will result in:   
					• clogged fuel filter and nozzle   
					• carbon build up on spark plug   
					• use of non-toxic anti-icer in fuel during very cold weather   
					IMPORTANT: Use a KEROSENE ONLY container. Be sure storage container is   
					clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to   
					shut down heater. Foreign matter may also require you to clean fuel system often.   
					6 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				VENTILATION   
					WARNING   
					Follow the minimum fresh, outside air ventilation   
					requirements. If proper fresh, outside air ventilation is not   
					provided, carbon monoxide poisoning can occur. Provide   
					proper fresh, outside air ventilation before running heater.   
					Provide a fresh air opening of at least three square feet (2800 square cm) for each   
					100,000 BTU/Hr rating. Provide extra fresh air if more heaters are being used.   
					Example: A 150,000 BTU/Hr heater requires one of the following:   
					• a two-car garage door raised six inches (15.24 cm)   
					• a single-car garage door raised nine inches (22.86 cm)   
					• two, thirty-inch (76.20 cm) windows raised twelve inches (30.48 cm)   
					WARNING   
					OPERATION   
					Review and understand the warnings in the Safety   
					Information Section, page 3. They are needed to safely   
					operate this heater. Follow all local codes when using this   
					heater.   
					To Start Heater   
					1. Follow all ventilation and safety information.   
					2. Fill fuel tank with kerosene or No. 1 fuel oil.   
					3. Attach fuel cap.   
					4. Plug power cord of heater into standard 230 volt/50 hertz, grounded (earthed)   
					outlet. Use an extension cord if needed. Use only a three-wire, grounded   
					(earthed) extension cord.   
					Extension Cord Wire Size Requirements   
					Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) conductor   
					101 to 200 feet (30.6 to 61 meters) long, use 14 AWG (1.5 mm2) conductor   
					Heater will start when power cord is plugged into outlet. If not, push in flame-   
					out control reset button (see Figures 6 and 7).   
					Flame-Out   
					Control   
					Reset   
					Flame-   
					Out   
					Button   
					Control   
					Reset   
					Button   
					Figure 6 - Flame-Out Control Reset   
					Button, 70,000 BTU/Hr Model   
					Figure 7 - Flame-Out Control Reset   
					Button, 100/150,000 BTU/Hr Models   
					Continued   
					7 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				To Stop Heater   
					1. Unplug power cord from outlet.   
					OPERATION   
					Continued   
					To Restart Heater   
					1. Wait 2 minutes after stopping heater.   
					2. Repeat steps under To Start Heater, page 7.   
					1. Drain fuel tank.   
					STORAGE   
					Note: Some models have drain plug on underside of fuel tank. If so, remove   
					drain plug to drain all fuel. If heater does not have drain plug, drain fuel through   
					fuel cap opening. Be sure all fuel is removed.   
					2. Replace drain plug if used.   
					3. Add one gallon (4 liters) of clean kerosene to fuel tank.   
					4. Attach fuel cap.   
					5. Move heater forwards and backwards to stir fuel.   
					6. Remove fuel cap or drain plug and drain fuel tank. Be sure all fuel is removed.   
					7. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel.   
					8. Store heater in dry place. Make sure storage place is free of dust and corrosive   
					fumes.   
					IMPORTANT: Do not store kerosene over summer months for use during next   
					heating season. Using old fuel could damage heater.   
					PREVENTATIVE   
					MAINTENANCE   
					SCHEDULE   
					WARNING   
					Never service heater while it is plugged in, operating, or   
					hot. Severe burns and electrical shock can occur.   
					Item   
					How Often   
					How To   
					Fuel tank   
					Flush every 150-200 hours   
					of operation or as needed.   
					See Storage above.   
					Air output and   
					Replace every 500 hours of   
					lint filters operation or once   
					a year.   
					See Air Output, Air Intake,   
					and Lint Filters, page 12.   
					Air intake   
					filter   
					Wash and dry with soap and   
					water every 500 hours of   
					operation or as needed.   
					See Air Output, Air Intake,   
					and Lint Filters, page 12.   
					Fuel filter   
					Clean twice a heating season   
					or as needed.   
					See Fuel Filter, pages 10   
					and 11.   
					Spark plug   
					Clean and regap every 600   
					hours operation or replace   
					as needed.   
					See Spark Plug, page 11.   
					Fan blades   
					Motor   
					Clean every season or as needed.   
					See Fan, page 15.   
					Not required/permanently   
					lubricated   
					8 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				TROUBLE-   
					SHOOTING   
					WARNING   
					Never service heater while it is plugged in, operating, or hot.   
					Severe burns and electrical shock can occur.   
					OBSERVED FAULT POSSIBLE CAUSE   
					REMEDY   
					Wrong pump pressure   
					See Pump Pressure   
					Adjustment, page 12.   
					Heater ignites, but   
					flame-out control   
					shuts off heater after   
					a short period of time   
					Dirty air output, air intake, See Air Output, Air Intake   
					and lint filters   
					and Lint Filters, page 12.   
					See Fuel Filter, pages 10   
					and 11.   
					Dirty fuel filter   
					Dirt in nozzle   
					See Nozzle, page 13.   
					Dirty photocell lens   
					Bad flame-out control   
					Clean photocell lens.   
					Replace flame-out control.   
					Heater will not   
					ignite, but motor runs   
					for a short period of   
					time.   
					Wrong pump pressure   
					See Pump Pressure   
					Adjustment, page 12.   
					Carbon deposits on spark   
					plug and/or improper gap   
					See Spark Plug, page 11.   
					Dirty fuel filter   
					See Fuel Filter, pages 10   
					and 11.   
					See Nozzle, page 13.   
					Dirt in nozzle   
					Drain and flush fuel tank   
					with clean kerosene. See   
					Storage, page 8.   
					Water in fuel tank   
					WARNING: High voltage!   
					Electronic ignitor not   
					Make sure electronic   
					grounded (earthed)   
					ignitor mounting is tight.   
					Bad electronic ignitor   
					Replace electronic   
					ignitor.   
					Motor does not start   
					when heater is   
					plugged in, fan   
					rotates slowly or   
					does not turn.   
					Flame-out control not reset   
					Binding pump rotor   
					Reset flame-out control   
					button, see Figures 6 and   
					7, page 7.   
					If fan is hard to turn, see   
					Pump Rotor, page 14.   
					9 
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SERVICE   
					PROCEDURES   
					WARNING   
					Never service heater while it is plugged in, operating, or   
					hot. Severe burns and electrical shock can occur.   
					Upper   
					Shell   
					Upper Shell Removal   
					1. Remove screws along each   
					side of heater using 5/16"   
					nut-driver. These screws   
					attach upper and lower   
					shells together.   
					Fan   
					Guard   
					2. Lift upper shell off.   
					3. Remove fan guard.   
					Figure 8 - Upper Shell Removal, 70,000 BTU/Hr Model   
					Upper   
					Shell   
					Fan   
					Guard   
					Figure 9 - Upper Shell Removal, 100/150,000 BTU/Hr Models   
					Fuel Filter   
					Fuel Filter   
					(70,000 BTU/Hr Model)   
					1. Remove side cover screws   
					using 5/16" nut-driver.   
					2. Remove side cover.   
					3. Pull rubber fuel line off   
					fuel filter neck.   
					4. Carefully pry bushing and   
					fuel filter out of fuel tank.   
					5. Wash fuel filter with clean   
					fuel and replace in tank.   
					6. Attach rubber fuel line to   
					fuel filter neck.   
					Side Cover   
					Fuel Line   
					7. Replace side cover.   
					Figure 10 - Fuel Filter Removal, 70,000 BTU/Hr Model   
					10   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Fuel Filter, Bushing,   
					and Lower Fuel Line   
					Fuel Filter   
					(100/150,000 BTU/Hr Models)   
					1. Remove side cover screws   
					using 5/16" nut-driver.   
					2. Remove side cover.   
					3. Pull upper fuel line off fuel   
					filter neck.   
					Upper   
					Fuel Line   
					4. Carefully pry bushing,   
					lower fuel line, and fuel   
					filter out of fuel tank.   
					5. Wash fuel filter with clean   
					fuel and replace in tank.   
					6. Attach upper fuel line to   
					fuel filter neck.   
					7. Replace side cover.   
					Side Cover   
					Figure 11 -15F0u,0e00lBFTiUlt/Herr Removal, 100/150,000 BTU/Hr Models   
					PFA/P 041.G   
					Spark Plug   
					1. Remove upper shell (see   
					Spark Plug   
					Wire   
					Burner   
					Head   
					page 10).   
					2. Remove fan (see page 15).   
					3. Remove spark plug wire   
					from spark plug.   
					4. Remove spark plug from   
					burner head using 13/16"   
					open-end wrench.   
					5. Clean and regap spark plug   
					electrodes as follows:   
					70,000 BTU/Hr model:   
					.055" (1.4 mm) gap,   
					100/150,000 BTU/Hr   
					models: .075" (1.9 mm)   
					gap.   
					Spark   
					Plug   
					6. Install spark plug in burner   
					head.   
					SPARK PLUG REMOVAL 70, 100 &150   
					Figure 12 - Spark Plug Removal   
					PFA/P 031A   
					7. Attach spark plug wire to   
					spark plug.   
					8. Replace fan (see page 15).   
					9. Replace fan guard and   
					upper shell.   
					Bend Here   
					to Adjust   
					Gap   
					Gap   
					Figure 13 - Spark Plug Gap   
					11   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Air Intake Filter   
					Filter End   
					Air Output, Air Intake,   
					and Lint Filters   
					1. Remove upper shell (see   
					page 10).   
					Cover   
					Fan Guard   
					2. Remove filter end cover   
					screws using 5/16" nut-   
					driver.   
					3. Remove filter end cover.   
					4. Replace air output and lint   
					filters.   
					Lint Filter   
					Air Output   
					Filter   
					5. Wash or replace air intake   
					filter (see Preventative   
					Maintenance Schedule,   
					page 8).   
					Figure 14 - Air Output, Air Intake, and Lint Filters,   
					70,000 BTU/Hr Model   
					6. Replace filter end cover.   
					7. Replace fan guard and   
					upper shell.   
					Air Intake Filter   
					Fan Guard   
					Filter End   
					Cover   
					IMPORTANT: Do not oil   
					filters.   
					Lint Filter   
					Air Output   
					Filter   
					Figure 15 - Air Output, Air Intake, and Lint Filters,   
					100,000/150,000 BTU/Hr Models   
					Pump Pressure   
					Adjustment   
					(70,000 BTU/Hr Model Shown)   
					1. Remove pressure gauge   
					plug from filter end cover.   
					2. Install accessory pressure   
					gauge (part number   
					Pressure   
					Gauge   
					Plug   
					Relief   
					Valve   
					HA1180).   
					3. Start heater (see Operation,   
					page 7). Allow motor to   
					reach full speed.   
					PRESSURE GAUGE PLUG   
					PFA/OV 006B   
					Figure 16 - Pressure Gauge Plug Removal   
					4. Adjust pressure. Turn relief   
					valve to right to increase   
					pressure. Turn relief valve   
					to left to decrease pressure.   
					See specifications at right   
					for correct pressure for   
					each model.   
					5. Remove pressure gauge.   
					Replace pressure gauge   
					plug in filter end cover.   
					Pressure   
					Gauge   
					Pump   
					Pressure   
					4.5 PSI   
					4.5 PSI   
					4.9 PSI   
					Model   
					70,000 BTU/Hr   
					100,000 BTU/Hr   
					150,000 BTU/Hr   
					Figure 17 - Adjusting Pump Pressure   
					12   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Nozzle   
					1. Remove upper shell (see   
					Combustion   
					Chamber   
					page 10).   
					2. Remove fan (see page 15).   
					3. Remove fuel and air line   
					hoses from burner head.   
					4. Remove spark plug wire   
					from spark plug.   
					Spark Plug   
					Wire   
					Burner Head   
					5. Remove spark plug from   
					burner head using 13/16"   
					open-end wrench.   
					6. Remove three screws   
					using 5/16" nut-driver and   
					remove burner head from   
					combustion chamber.   
					7. Place burner head into vise   
					and lightly tighten.   
					Screw   
					Spark   
					Plug   
					8. Carefully remove nozzle   
					from burner head using   
					5/8" socket wrench (see   
					Figure 19).   
					Air Line Hose   
					Fuel Line Hose   
					9. Blow compressed air   
					through face of nozzle.   
					This will free any dirt in   
					nozzle area.   
					Figure 18 - Removing Burner Head   
					10. Inspect nozzle seal for   
					damage.   
					11. Replace nozzle into burner   
					head and tighten firmly   
					(80-110 inch-pounds/9.1-   
					12.4 n-m).   
					12. Attach burner head to   
					combustion chamber.   
					13. Install spark plug in burner   
					head.   
					Nozzle   
					Face   
					Nozzle   
					Seal   
					Nozzle   
					14. Attach spark plug wire to   
					spark plug.   
					15. Attach fuel and airline   
					hoses to burner head.   
					16. Replace fan (see page 15).   
					17. Replace fan guard and   
					upper shell.   
					Burner   
					Head   
					Fuel line   
					Fitting   
					Air line   
					Fitting   
					Figure 19 - Removing Nozzle   
					13   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Blade   
					Pump   
					Plate   
					Air   
					Intake   
					Filter   
					Pump Rotor   
					(Procedure if rotor is binding)   
					1. Remove upper shell (see   
					page 10).   
					Filter End   
					Cover   
					2. Remove filter end cover   
					screws using 5/16" nut-   
					driver.   
					Fan Guard   
					3. Remove filter end cover   
					and air filters.   
					4. Remove pump plate   
					screws using 5/16" nut-   
					driver.   
					Insert   
					Rotor   
					Air Output   
					50 ROTOR   
					PFA/P 056   
					Filter   
					5. Remove pump plate.   
					6. Remove rotor, insert, and   
					blades.   
					Figure 20 - Rotor Location, 70,000 BTU/Hr Model   
					Pump   
					Blade   
					Plate   
					7. Check for debris in pump.   
					If debris is found, blow   
					out with compressed air.   
					8. Install insert and rotor.   
					9. Check gap on rotor.   
					Adjust to .003"/.004"   
					(.076/.101 mm) if needed   
					(see Figure 22).   
					Air   
					Intake   
					Filter   
					Filter End   
					Cover   
					Fan Guard   
					Insert   
					Rotor   
					Note: Rotate rotor one   
					full turn to insure the gap is   
					.003"/.004" (.076/.101 mm) at   
					tightest position. Adjust if   
					needed.   
					Air   
					Output   
					150 ROTOR   
					FilPteFrA/P 059   
					10. Install blades, pump plate,   
					air filters, and filter end   
					cover.   
					Figure 21 - Rotor Location, 100/150,000 BTU/Hr Models   
					11. Replace fan guard and   
					upper shell.   
					Gap Adjusting   
					Screw   
					12. Adjust pump pressure (see   
					page 12).   
					Note: If rotor is still binding,   
					proceed as follows.   
					.003"/.004"   
					(.076/.101 mm) Gap   
					Measured With   
					Feeler Gauge   
					Sandpaper   
					13. Perform steps 1 through 6   
					above.   
					14. Place fine grade sandpaper   
					(600 grit) on flat surface.   
					Sand rotor lightly in   
					Blade   
					Rotor   
					“figure 8” motion four   
					times (see Figure 23).   
					15. Reinstall insert and rotor.   
					16. Perform steps 10 through   
					12 above.   
					Gap   
					Adjusting   
					Screw   
					Figure 22 - Gap Adjusting   
					Screw Locations   
					Figure 23 - Sanding Rotor   
					14   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Fan   
					IMPORTANT: Remove fan   
					from motor shaft before   
					removing motor from heater.   
					The weight of the motor   
					resting on the fan could   
					damage the fan pitch.   
					Fan   
					Setscrew   
					1. Remove upper shell (see   
					page 10).   
					2. Use 1/8" allen wrench to   
					loosen setscrew which   
					holds fan to motor shaft.   
					3. Slip fan off motor shaft.   
					4. Clean fan using a soft cloth   
					moistened with kerosene or   
					solvent.   
					Motor   
					Shaft   
					Figure 24 - Fan, Motor Shaft, and Setscrew Location   
					5. Dry fan thoroughly.   
					6. Replace fan on motor   
					shaft. Place fan hub flush   
					with end of motor shaft   
					(see Figure 25).   
					7. Place setscrew on flat of   
					shaft. Tighten setscrew   
					firmly (40-50 inch-pounds/   
					4.5-5.6 n-m).   
					Fan   
					8. Replace fan guard and   
					upper shell.   
					Flush   
					Motor   
					Shaft   
					Setscrew   
					Figure 25 - Fan Cross Section   
					Output Rating (BTU/Hr)   
					Fuel   
					70,000   
					100,000   
					150,000   
					SPECIFICATIONS   
					Use Only Kerosene or No. 1 Fuel Oil   
					Fuel Tank Capacity   
					(U.S. Gal./Liters)   
					5.0/18.9   
					.52/1.97   
					9.0/34.1   
					.78/2.95   
					13.5/51.1   
					1.10/4.16   
					Fuel Consumption   
					(Gal. Per Hr./Liters Per Hr.)   
					Electric Requirements   
					Amperage (Normal Run)   
					Hot Air Output (CFM/CMM)   
					RPM   
					220 V/60 Hz (Same All Models)   
					2.0   
					2.0   
					490/13.9 500/14.2   
					3450 3450   
					2.0   
					250/7.1   
					3450   
					15   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3 
					ILLUSTRATED   
					PARTS   
					1 
					BREAKDOWN   
					2 
					70,000 BTU/Hr   
					4 
					5 
					10   
					7 
					8 
					6 
					14   
					12   
					12   
					11   
					18   
					15   
					16   
					19   
					17   
					23   
					24   
					21   
					20   
					25   
					22   
					10-1   
					10-2   
					35   
					43   
					36   
					27   
					44   
					26   
					29   
					10-3   
					10-4   
					31   
					32   
					28   
					30   
					33   
					10-7   
					10-5   
					38   
					39   
					37   
					10-6   
					34   
					Burner Head Assembly   
					18-1   
					18-2   
					40   
					13   
					18-3   
					41   
					9 
					18-4   
					18-5   
					18-6   
					42   
					18-7   
					45   
					18-18   
					18-8   
					18-17   
					18-16   
					18-9   
					18-10   
					18-11   
					18-12   
					18-15   
					18-14   
					Motor and Pump Assembly   
					18-13   
					16   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				This list contains replaceable parts used in your heater. When ordering parts,   
					be sure to provide the correct model and serial numbers (from the model plate),   
					then the part number and description of the desired part.   
					PARTS LIST   
					70,000 BTU/Hr   
					KEY PART   
					PART   
					DESCRIPTION   
					KEY PART   
					NO. NUMBER   
					PART   
					DESCRIPTION   
					NO.   
					NUMBER   
					QTY.   
					QTY.   
					18-14 M29612-01   
					18-15 M12461-31   
					18-16 M50016   
					18-17 M8643   
					18-18 FHPF3-2C   
					Output Filter   
					1 
					6 
					1 
					4 
					2 
					1 
					2 
					1 
					6 
					1 
					6 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					M51104-01   
					098511-54   
					100647-01   
					098512-34   
					M11084-29   
					M16660   
					Handle   
					Upper Shell   
					1 
					1 
					6 
					1 
					2 
					1 
					2 
					1 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					2 
					1 
					3 
					2 
					1 
					1 
					2 
					2 
					Screw, #10-32 x 1"   
					Elbow, 90˚ (Barb Fitting)   
					Blade   
					Screw, #10-32 x 1/4"   
					Fan Guard   
					Screw, #10-16 x 1/2"   
					Combustion Chamber   
					Screw, #10-16 x 3/4"   
					Photocell Bracket   
					Screw, #6-32 x 3/8"   
					Photocell Assembly   
					Power Cord   
					19   
					M51105-01   
					NTC-4C   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					Hex locknut   
					M10908-2   
					HA3019   
					M50104-02   
					M11084-26   
					098511-12   
					M11271-8   
					M12462-15   
					M16841-58   
					M15823-39   
					M29652-04   
					079973-01   
					M16841-57   
					M10990-3   
					M50876-05   
					Bushing (wires)   
					Screw, #10-16 x 3/8"   
					Lower Shell   
					099055-07   
					**   
					10   
					Burner Head Assembly   
					Nozzle   
					Clip Nut   
					10-1 M50880-01   
					10-2 M10659-1   
					10-3 M10809-1   
					10-4 M8882   
					Relay (motor start)   
					Wire Assembly (red 9 1/2")   
					Screw, #8-18 x 1/2"   
					Rubber Airline   
					Nozzle Seal Washer   
					Nozzle Seal Spring   
					Nozzle Seal Sleeve   
					Burner Head Body   
					Barb Fitting   
					10-5 M51098-02   
					10-6 M50820-01   
					10-7 M10962-2   
					Fuel Line   
					Wire Assembly (red 8 1/2")   
					Rubber Bushing   
					Fuel Filter Assembly   
					(Includes bushing)   
					Electronic Ignitor   
					Screw, #10-16 x 3/4"   
					Terminal Board   
					Rivet   
					Spark Plug   
					Screw, #10-16 x 1/2"   
					Bushing   
					Strain Relief Bushing   
					Fan   
					Rubber Bumper   
					Screw, #8-32 x 1/4"   
					(holds relay in position)   
					Motor and Relay   
					Bracket Assembly   
					Motor and Pump Assembly   
					Motor (220V/60Hz)   
					Pump Body   
					11   
					M11084-27   
					M30865-02   
					M11143-1   
					101587-01   
					M50631   
					12   
					13   
					14   
					15   
					16   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					40   
					41   
					42   
					43   
					44   
					45   
					098557-07   
					M11084-29   
					099125-02   
					099157-01   
					097702-01   
					097630-02   
					098513-62   
					1 
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					M12461-13   
					Fuel Tank Cap   
					Flame-Out Control   
					Fuel Tank   
					17   
					18   
					098138-01   
					**   
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					3 
					1 
					1 
					1 
					1 
					M50899-03AA Side Cover   
					18-1 099656-02   
					18-2 079975-02   
					18-3 M22009   
					18-4 M22456-1   
					18-5 M29608   
					18-6 M29632   
					18-7 M29633   
					18-8 M29609   
					18-9 M12461-31   
					18-10 M8940   
					M11084-26   
					099177-01   
					078918-01   
					M9900-162   
					M27417   
					Screw, #10-16 x 3/8"   
					Hex Nut   
					Terminal Board Tab Cap   
					Wire Assembly (green 16")   
					Drain Plug   
					Insert   
					Rotor   
					End Pump Cover   
					Lint Filter   
					Intake Filter   
					PARTS AVAILABLE - NOT SHOWN   
					End Filter Cover   
					Screw, #10-32 x 1"   
					Steel Ball (1/4" Dia.)   
					Pressure Relief Spring   
					Adjusting Screw   
					Plug   
					M18053   
					Filler Neck Screen   
					Wiring Decal   
					Tradename Decal   
					General Information Decal   
					1 
					1 
					2 
					1 
					098227-53   
					097649-01   
					098493-01   
					18-11 M10993-1   
					18-12 M27694   
					18-13 M22997   
					**Not available as an assembly, order parts separately.   
					17   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ILLUSTRATED   
					PARTS   
					2 
					BREAKDOWN   
					1 
					100,000 BTU/Hr   
					3 
					4 
					5 
					8 
					12   
					13   
					14   
					7 
					15   
					16   
					8-1   
					9 
					10   
					17   
					8-2   
					11   
					30   
					20   
					19   
					31   
					18   
					28   
					21   
					25   
					8-3   
					8-4   
					27   
					23   
					24   
					36   
					22   
					29   
					8-7   
					33   
					34   
					35   
					8-5   
					32   
					44   
					26   
					BURNER HEAD 100 EAI/EBI   
					PFA/P 022   
					37   
					8-6   
					Burner Head Assembly   
					38   
					39   
					45   
					42   
					41   
					13-1   
					13-3   
					13-4   
					13-5   
					40   
					13-2   
					43   
					6 
					13-6   
					13-7   
					13-18   
					13-17   
					13-8   
					13-9   
					13-16   
					13-15   
					13-10   
					13-11   
					13-14   
					13-13   
					13-12   
					Motor and Pump Assembly   
					18   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				This list contains replaceable parts used in your heater. When ordering parts,   
					be sure to provide the correct model and serial numbers (from the model plate),   
					then the part number and description of the desired part.   
					PARTS LIST   
					100,000 BTU/Hr   
					KEY   
					PART   
					PART   
					KEY   
					PART   
					PART   
					NO.   
					NUMBER   
					DESCRIPTION   
					QTY. NO.   
					NUMBER   
					DESCRIPTION   
					QTY.   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					8-1   
					8-2   
					8-3   
					8-4   
					8-5   
					8-6   
					8-7   
					9 
					10   
					11   
					12   
					13   
					098511-138   
					100647-01   
					098512-31   
					M16660   
					HA3019   
					M27417   
					M10908-2   
					**   
					M23103   
					M10659-1   
					M10809-1   
					M8882   
					M50924-03   
					M50820-02   
					M10962-2   
					M11084-27   
					M50814-06   
					M51345-01   
					097293-01   
					**   
					Upper Shell   
					1 
					8 
					1 
					1 
					1 
					1 
					2 
					1 
					1 
					2 
					1 
					1 
					1 
					2 
					1 
					3 
					1 
					1 
					1 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					4 
					1 
					6 
					1 
					1 
					4 
					1 
					15   
					16   
					17   
					M50631   
					M12461-13   
					098138-02   
					Rubber Bumper   
					Screw, #8-32 x 1/4"   
					Motor and Relay   
					Bracket Assembly   
					Relay (motor start)   
					Wire Assembly (red 13 1/2")   
					Hex locknut   
					Electronic Ignitor   
					Screw, #10-16 x 3/4"   
					Terminal Board   
					Rivet   
					Bushing   
					Wire Assembly (green 16")   
					Bushing   
					Button Plug   
					Screw, #10-16 x 1/2"   
					Lower Shell   
					Clip Nut   
					Screw, #8-18 x 1/2"   
					Fuel filter   
					Rubber Bushing   
					Fuel Line   
					Fuel Tank   
					Fuel Tank Cap   
					Wire Assembly (red 8 1/2")   
					Flame-Out Control   
					Strain Relief Bushing   
					Power Cord   
					2 
					2 
					Screw, #10-16 x 1/2"   
					Combustion Chamber   
					Photocell Bracket   
					Photocell Assembly   
					Drain Plug   
					Screw, #6-32 x 3/8"   
					Burner Head Assembly   
					Nozzle   
					Nozzle Seal Washer   
					Nozzle Seal Spring   
					Nozzle Seal Sleeve   
					Burner Head Body   
					Barb Fitting   
					Spark Plug   
					Screw, #10-16 x 1/2"   
					Air Line   
					Fuel Line   
					Fan   
					Motor and Pump Assembly   
					Motor (220V/60Hz)   
					Pump Body   
					Screw, #10-32 x 1/4"   
					Insert   
					Rotor   
					End Pump Cover   
					Intake Filter   
					1 
					1 
					1 
					2 
					1 
					2 
					1 
					1 
					2 
					1 
					2 
					1 
					6 
					1 
					8 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					4 
					1 
					1 
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					40   
					41   
					42   
					43   
					44   
					45   
					M12462-15   
					M16841-59   
					NTC-4C   
					098557-07   
					M11084-29   
					099125-02   
					099157-01   
					M50104-03   
					M9900-192   
					M50104-01   
					099213-01   
					M11084-27   
					098511-140   
					M11271-8   
					M15823-39   
					M51150-01   
					M10990-3   
					M51151-01   
					098513-21   
					097702-01   
					M16841-57   
					097630-02   
					M11143-1   
					099055-07   
					13-1 099656-01   
					13-2 079975-02   
					13-3 FHPF3-2C   
					13-4 M22009   
					13-5 M22456-1   
					13-6 M50545   
					13-7 M12179   
					13-8 M16545   
					13-9 M8940   
					13-10 M10993-1   
					13-11 M27694   
					13-12 M22997   
					13-13 M12461-31   
					13-14 M12244-1   
					13-15 M12461-31   
					13-16 M11637   
					13-17 M50820-02   
					13-18 M8643   
					End Filter Cover   
					Steel Ball (1/4" Dia.)   
					Pressure Relief Spring   
					Adjusting Screw   
					Plug   
					Screw, #10-32 x 1"   
					Output Filter   
					Screw, #10-32 x 1"   
					Lint Filter   
					M51077-01AA Side Cover   
					M11084-27   
					078918-01   
					099177-01   
					Screw, #10-16 x 1/2"   
					Terminal Board Tab Cap   
					Hex Nut   
					PARTS AVAILABLE - NOT SHOWN   
					M18053   
					Filler Neck Screen   
					Wiring Decal   
					Tradename Decal   
					General Information Decal   
					1 
					1 
					2 
					1 
					Barb Fitting   
					Blade   
					Fan Guard   
					098227-53   
					097650-01   
					098493-01   
					14   
					M51114-01   
					**Not available as an assembly, order parts separately.   
					19   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ILLUSTRATED   
					PARTS   
					BREAKDOWN   
					2 
					150,000 BTU/Hr   
					1 
					3 
					4 
					44   
					6 
					7 
					9 
					46   
					10   
					5 
					16   
					8 
					11   
					7-1   
					14   
					19   
					23   
					7-2   
					12   
					24   
					15   
					39   
					28   
					37   
					13   
					45   
					25   
					17   
					7-3   
					7-4   
					26   
					38   
					27   
					18   
					20   
					7-7   
					22   
					21   
					7-5   
					29   
					43   
					47   
					30   
					BURNER HEAD 100 EAI/EBI   
					PFA/P 022   
					7-6   
					Burner Head Assembly   
					31   
					40   
					32   
					42   
					10-1   
					35   
					10-3   
					10-4   
					10-5   
					10-2   
					33   
					34   
					36   
					10-6   
					41   
					10-7   
					10-18   
					10-17   
					10-8   
					10-9   
					10-16   
					10-15   
					10-10   
					10-11   
					10-14   
					10-13   
					10-12   
					Motor and Pump Assembly   
					20   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				This list contains replaceable parts used in your heater. When ordering parts, be   
					sure to provide the correct model and serial numbers (from the model plate), then   
					the part number and description of the desired part.   
					PARTS LIST   
					150,000 BTU/Hr   
					KEY   
					NO.   
					PART   
					NUMBER   
					KEY   
					NO.   
					PART   
					NUMBER   
					QTY.   
					QTY.   
					DESCRIPTION   
					DESCRIPTION   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					098511-138   
					100647-01   
					098512-29   
					099229-01   
					M10908-2   
					HA3019   
					Upper Shell   
					1 
					8 
					1 
					1 
					2 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					2 
					1 
					3 
					1 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					4 
					1 
					6 
					1 
					1 
					4 
					2 
					1 
					1 
					2 
					2 
					1 
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					098557-07   
					M11084-29   
					M51345-02   
					M51150-01   
					M51151-02   
					M10990-3   
					M50814-03   
					098511-140   
					M50104-03   
					M50104-01   
					M11084-27   
					M11271-8   
					M15823-39   
					098513-56   
					097702-01   
					097630-02   
					M11143-1   
					099055-07   
					Ignitor Kit   
					Screw, #10-16 x 3/4"   
					Fuel Line   
					1 
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					2 
					2 
					6 
					8 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					4 
					1 
					1 
					Screw, #10-16 x 1/2"   
					Combustion Chamber   
					Photocell Bracket   
					Screw, #6-32 x 3/8"   
					Photocell Assembly   
					Burner Head Assembly   
					Nozzle with Sleeve   
					Nozzle Washer   
					Nozzle Spring   
					Nozzle Sleeve   
					Burner Head Body   
					Barb Fitting   
					Spark Plug   
					Screw, #10-16 x 1/2"   
					Fan   
					Motor and Pump Assembly   
					Motor (220V/60Hz)   
					Pump Body   
					Screw #10-32 x 1/4"   
					Rotor Insert   
					Pump Rotor   
					Pump End Cover   
					Intake Filter   
					Filter End Cover   
					Steel Ball, 1/4" diameter   
					Relief Spring   
					Adjusting Screw   
					Plug   
					Screw #10-32 x 1"   
					Output Filter   
					Screw, #10-32 x 1"   
					Lint Filter   
					Fuel Filter   
					Fuel Line Tube   
					Rubber Bushing   
					Air Line   
					Lower Shell   
					Bushing   
					Bushing   
					Screw, #10-16 x 1/2"   
					Clip Nut   
					Screw, #8-18 x 1/2"   
					Fuel Tank   
					Fuel Tank Cap   
					Flame-Out Control   
					Strain Relief Bushing   
					Power Cord   
					**   
					7-1   
					HA3010   
					7-2   
					7-3   
					7-4   
					7-5   
					7-6   
					7-7   
					M10659-1   
					M10809-1   
					M8882   
					M50924-03   
					M50820-02   
					HA3012   
					M11084-27   
					097293-01   
					**   
					8 
					9 
					10   
					10-1 099656-01   
					10-2 079975-02   
					10-3 FHPF3-2C   
					10-4 M22009   
					10-5 M22456-1   
					10-6 M50545   
					10-7 M12179   
					10-8 M16545   
					10-9 M8940   
					10-10 M10993-1   
					10-11 M27694   
					10-12 M22997   
					10-13 M12461-31   
					10-14 M12244-1   
					10-15 M12461-31   
					10-16 M11637   
					10-17 M50820-02   
					10-18 M8643   
					M51077-01AA Side Cover   
					M11084-27   
					099125-03   
					099157-01   
					M16841-59   
					Screw, #10-16 x 1/2"   
					Terminal Board   
					Rivet   
					Wire Assembly   
					(Red, 13 1/2")   
					Wire Assembly (Red, 6")   
					Drain Plug   
					(Includes “O” Ring)   
					Hex Nut   
					Tab Cap   
					Screw, #10-16 x 3/8"   
					Button Plug   
					Screw, #10-16 x 1/2"   
					Wire Assembly   
					(Green, 16")   
					1 
					1 
					40   
					41   
					M16841-57   
					M27417   
					1 
					1 
					1 
					2 
					1 
					2 
					42   
					43   
					44   
					45   
					46   
					47   
					099177-01   
					078918-01   
					099230-01   
					099213-01   
					M11084-27   
					M9900-192   
					Barb Fitting   
					Blade   
					1 
					11   
					M50631   
					Rubber Bumper   
					Motor Mounting Bracket   
					Motor Start Relay   
					Screw, #8-32 x 1/4"   
					Hex Lock Nut, 1/4-20   
					Fan Guard   
					PARTS AVAILABLE - NOT SHOWN   
					12   
					13   
					14   
					15   
					16   
					098138-02   
					M12462-15   
					M12461-13   
					NTC-4C   
					M18053   
					Filler Neck Screen   
					Tradename Decal   
					General Information Decal   
					Wiring Decal   
					1 
					2 
					1 
					1 
					097650-01   
					098493-01   
					098227-53   
					M51114-01   
					** Not available as an assembly. Order parts separately.   
					21   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WHEELS AND HANDLES FOR   
					100,000 AND 150,000 BTU/Hr MODELS   
					KEY PART   
					PART   
					100,000 150,000   
					NO. NUMBER   
					DESCRIPTION   
					QTY.   
					QTY.   
					1 
					HA2203   
					HA2204   
					Handles   
					Handles   
					2 
					— 
					8 
					1 
					— 
					8 
					2 
					2 
					1 
					— 
					— 
					2 
					8 
					— 
					1 
					8 
					2 
					2 
					— 
					1 
					2 
					3 
					M12345-33 Screw, #10-24 x 1 3/4"   
					M12342-3   
					M12831-3   
					NTC-3C   
					097896-01   
					M28526   
					Wheel Support Frame   
					Wheel Support Frame   
					Hex Nut, #10-24   
					Wheel   
					4 
					5 
					6 
					7 
					Cap Nut   
					M51015-01 Axle   
					M16801-2 Axle   
					1 
					2 
					3 
					4 
					5 
					7 
					6 
					22   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Power Plug   
					220V/60Hz   
					WIRING   
					DIAGRAMS   
					White   
					Black   
					Green   
					White   
					White   
					B 
					Spark Plug   
					Flame-   
					Out   
					Blue   
					White   
					Blue   
					Orange   
					Terminal   
					Board   
					Reset   
					Button   
					Ignitor   
					Motor   
					Control   
					Photocell   
					Red   
					Red   
					Green/   
					Yellow   
					R 
					Red   
					S or 2   
					Red   
					M or 3   
					Black   
					Motor   
					Start   
					Relay   
					L or 1   
					Figure 26 - Wiring Diagram   
					ACCESSORIES   
					Purchase accessories from   
					your local dealer.   
					AIR GAUGE KIT - HA1180   
					For all models. Special tool to   
					check pump pressure.   
					HEAVY DUTY WHEELS AND   
					HANDLE KIT - HA1202   
					For heavy duty applications.   
					Makes your heater even more   
					portable and convenient.   
					For 70,000 BTU/Hr model only.   
					23   
					101585   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARRANTY AND REPAIR SERVICE   
					CERTIFICATE OF GENERAL   
					EQUIPMENT - LIMITED 90 DAY WARRANTY   
					DESA International warrants new Products sold by it to be   
					POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING   
					THOSEOFMERCHANTABILITYANDFITNESSFORAPAR-   
					TICULAR PURPOSE ARE LIMITED TO THE DURATION OF   
					THIS EXPRESS WARRANTY.   
					free from defects in material or workmanship for a period of   
					ninety days after date of delivery to the first user and subject to   
					the following conditions:   
					DESA International's obligation and liability under this   
					Warranty is expressly limited to repairing or replacing at DESA   
					International's option, any parts which appear to DESA Interna-   
					tional upon inspection to have been defective in material or   
					workmanship when shipped from the factory. Such parts shall   
					beprovidedatnocosttotheuser, atthebusinessestablishment   
					of any factory authorized service center or the factory during   
					regular working hours. The Warranty shall not apply to compo-   
					nent parts or accessories of Products not manufactured by   
					DESA International and which carry the warranty of the manu-   
					facturer thereof, or to normal maintenance (such as pressure   
					adjustments) or to normal maintenance parts (such as filters   
					and spark plugs). Replacement or repair parts installed in the   
					Product covered by this Warranty are warranted only for the   
					remainder of this Warranty as if such parts were original compo-   
					nents of said Product. DESA INTERNATIONAL MAKES NO   
					OTHER EXPRESS WARRANTY. TO THE EXTENT PERMIT-   
					TED BY LAW DESA INTERNATIONAL MAKES NO IMPLIED   
					WARRANTY AND MAKES NO WARRANTY OF MER-   
					CHANTABILITY OR FITNESS FOR ANY PARTICULAR PUR-   
					Any transportation charges, costs of installation, duty,   
					taxes or any other charges whatsoever must be borne by the   
					user. DESA International's obligation under this limited War-   
					ranty shall not include any liability for direct, indirect, incidental,   
					or consequential damage or delay. If requested by DESA   
					International, Products or parts for which a warranty claim is   
					made are to be returned transportation prepaid by user to the   
					factory. Any improper use, including operation after discovery   
					of defective or worn parts, operation beyond capacity, substi-   
					tution of parts not approved by DESA International, or any   
					alteration or repair by others in such manner as in DESA   
					International's judgement affects the Product materially and   
					adversely, shall void this Warranty.   
					NO EMPLOYEE OR REPRESENTATIVE IS AUTHORIZED   
					TO CHANGE THIS WARRANTY IN ANY WAY OR GRANT   
					ANY OTHER WARRANTY UNLESS SUCH CHANGE IS   
					MADEINWRITINGANDSIGNEDBYANOFFICEROFDESA   
					INTERNATIONAL AT ITS HOME OFFICE.   
					WARRANTY SERVICE   
					Always specify model and serial numbers when communicating   
					with the factory.   
					We reserve the right to amend these specifications at any time   
					without notice. The only Warranty applicable is our standard   
					written Warranty. We make no other Warranty, expressed or   
					implied.   
					A Service Manual is available by writing to the Technical Service   
					Department at:   
					DESA   
					INTERNATIONAL   
					Corporate Headquarters   
					2701 Industrial Drive   
					P.O. Box 90004   
					Bowling Green, Kentucky 42102-9004   
					U.S.A.   
					101585-01   
					Rev. B   
					9/94   
					Printed in U.S.A.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |