IMPORTANT INFORMATION  
2
1.  
Read these instructions entirely before beginning any part of the installation. Save these instructions for any  
future repairs.  
2.  
3.  
Use these instructions as a guide during the installation of the fireplace.  
Be sure these instructions become the property of and are reviewed by all future users of this fireplace to  
encourage proper operation and maintenance.  
4.  
5.  
6.  
All the parts used with this fireplace system must be installed in accordance with these installation instructions.  
Failure to do so may be hazardous and will void the warranty.  
This fireplace and accessories should not be altered in any way that is not specifically recommended in this  
manual.  
Refer to your local building code for local requirements pertaining to installation of factory-built fireplaces.  
Martin Hearth & Heating fireplaces are intended for installation and use according to standard NFPA 211 of the  
National Fire Protection Association.  
7.  
8.  
This fireplace must not be installed with a masonry flue.  
This fireplace and chimney should not be used for venting a wood or coal burning heater or fireplace insert.  
WARNING: DO NOT INSTALL A SEPARATE SOLID FUEL INSERT OR GAS FIREPLACE INSERT IN THIS FIREPLACE AND CHIMNEY  
SYSTEM WITHOUT WRITTEN AUTHORIZATION FROM MARTIN HEARTH & HEATING.  
Do not pack required air spaces with combustible material or insulation not specifically recommended for use  
in such areas.  
9.  
Intended Product Usage  
This fireplace is intended for supplemental heating only and is not intended for use as a primary heatingsystem.  
This fireplace is designed to sit directly on a combustible floor. The fireplace can be installed with zero clearances  
to combustible building materials at the side, back and top spacers. Only parts manufactured by Martin Hearth &  
Heating and labeled for use with this fireplace should be used in the installation of the fireplace except for special roof  
flashings that may be fabricated locally. The use of improper parts in the installation can be hazardous and voids the  
warranty offered by Martin Hearth & Heating.  
This fireplace is designed to burn solid wood fuel (wood).This fireplace is not designed to burn coal, unplumbed liquid  
fuels, unplumbed gaseous fuels or household refuse. Any attempt to burn these fuels in the fireplace can be hazard-  
ous.  
This fireplace is designed for installation in mobile homes if it is installed in accordance with figure 32 in this manual,  
which includes using an OAC6 combustion air assembly, WB36LR glass door, SVT firestop thimble, and use either the  
LLK or RLK louver kit.  
WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A MOBILE HOME.  
CAUTION: IF INSTALLED IN A MOBILE HOME, THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.  
WARNING: THIS FIREPLACE AND CHIMNEY MUST NOT BE USED FOR VENTING A SOLID FUEL HEATER OR FIREPLACE INSERT UNLESS  
WRITTEN AUTORIZATION IS GIVEN BY MARTIN HEARTH & HEATING. FAILURE TO HEED THIS WARNING MAY CAUSE FIRE HAZARD AND WILL  
VOID THE WARRANTY.  
improper installation or use of this fireplace will void its warranty and can cause:  
1. Damage to the fireplace from overheating.  
2. Hazardous temperatures to develop on combustible materials adjacent to the fireplace or chimney.  
3. The emission of smoke, sparks or hazardous gases into the dwelling.  
4. Leakage of rain water into the dwelling.  
3
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION GUIDELINES  
5
As wood is burned in the fireplace, room air enters the air slot on the lower front edge and circulates around the  
firebox.  
The air circulation around the firebox serves to cool the fireplace and must not be blocked in any manner.  
Blocking of the inlet slot or outlet louver will cause the firebox to reach hazardous temperatures.  
When an OAC4 combustion air assembly and a combustion air duct are attached to the connecting point on  
the side of the fireplace, combustion air may enter the firebox through a dampered opening behind the side  
panel. This feature is designed for your benefit to reduce the room air used for combustion and to prevent  
excessive loss of heat from the room. When the fireplace is in use, this damper should be open. When the  
fireplace is not in use, the damper should be closed to prevent cold air from entering the firebox. The combustion  
air damper is open when the lever located on the side of the firebox is up and closed when the lever is down.  
Outside air for combustion is optional unless required by federal, state or local building codes. See the section  
of this manual providing the instructions for installation of the combustion air assembly for additional information.  
Glass doors should be installed to receive the maximum benefit from your fireplace. For large fires, the  
maximum heating benefit from the fireplace will be obtained with the doors open due to the high amount of  
radiant heat being emitted out of the front opening of the fireplace. With a small fire, or before retiring in the  
evenings, it is best to operate the fireplace with the doors closed to prevent excessive room air from being  
drawn up the chimney. When the doors are open, the mesh screens should be closed to help keep burning  
embers from popping out of the firebox.  
The unique design of the fireplace allows the routing of the combustion air duct downward, horizontally or  
upward to obtain the outside combustion air. This permits maximum flexibility in planning your installation. See  
figure 22 for typical installation methods. Be sure to review the precautions and recommendations in the  
section of this manual pertaining to outside combustion air assembly.  
The fireplace also is equipped with a flue damper, which must be open when the fireplace is in use. The flue  
damper control lever is located inside the fireplace. The counterweighted damper is operated by simply pushing  
up to open or pulling down to close the damper. When the fireplace is not in use, the damper should be closed  
to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping up the  
chimney. NOTE: It is normal for a small amount of smoke to be released from the upper portion of the fireplace  
the first few times you use your new Martin Hearth & Heating fireplace. This results from an oil residue on the  
metal. Open a door or window to allow the smoke to escape.  
WARNING: Fireplaces equipped with glass doors should be operated only with the glass doors fully open or  
fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace opening, creating  
risks of both fire and smoke.  
All fireplace chimneys are in direct contact with cold air on the exterior of the structure. Consequently, when  
the fireplace is not in use, cold air can fall down the chimney of the fireplace to cool off the fireplace chase.  
Therefore, the fireplace chase must be insulated to minimize the risk of cold air infiltration to the home. Even  
if the fireplace chase is adequately insulated, this cannot completely ensure that cold air infiltration into the  
structure will be eliminated. Cold air infiltration is a possibility with any fireplace or device that freely  
communicates with the air on the outside of the structure. Today’s homes are more energy-efficient and,  
therefore, better insulated and tightly constructed. Unfortunately, when air is removed from the house, as by  
a bathroom fan, or consumed by a furnace, additional air is needed to replace the air consumed. Unless the  
additional air is supplied, this can cause a negative pressure in the home. When this happens, the house will  
draw in outside air from the cracks in the windows, down the fireplace flue or other locations of air leakage in  
the home. Because cold air infiltration may be unavoidable in some structures, Martin Hearth & Heating is not  
responsible for heat loss or air infiltration through or around the fireplace.  
4
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEARANCES  
6
5
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE COMPONENTS  
MODEL NUMBER DESCRIPTION  
B36LA, B36RA  
Left or right end open fireplace. Includes wire firescreen, sealing flue damper and  
outside combustion air capability. When installed, outside combustion air can be  
connected to left side. See installation instruction for details.  
4-foot chimney section (8-inch-diameter flue).  
S48  
S36  
S18  
S12  
SE30  
3-foot chimney section (8-inch-diameter flue).  
1-1/2 foot chimney section (8-inch-diameter flue).  
1-foot chimney section (8-inch-diameter flue).  
30-degree elbows (package contains two 8 inch diameter elbows). One pair is required  
for each offset. Maximum -- two pairs (4 elbows per chimney).  
Chimney support (required when chimney height exceeds 30 feet).  
Round chimney cap for contemporary installations. Includes storm collar.  
Round telescoping chimney cap.  
SCS  
SC  
SCL  
SQL8  
612  
Square telescoping chimney cap.  
0-6/12 pitch flashing for contemporary installation. One required with SC round chimney  
cap on 0-6/12 pitch roof.  
1212  
6/12 - 12/12 pitch flashing for contemporary installation. One required with SC round  
chimney cap on 6/12-12/12 pitch roof.  
SF  
14 1/2” inch firestop spacer --One required at each ceiling or floor level.  
Firestop spacer - for 30º chimney incline through ceiling or floor.  
4-inch insulated combustion air duct -- 8 foot lengths.  
4-inch duct connector (for splicing FP-4 ducts). Includes two clamps.  
4-inches outside combustion assembly.  
SF-30  
FP-4-U  
403  
OAC4  
WB36LR  
H1658  
H1627  
Optional polished brass glass door kit.  
Hearth extension board for front opening. (16” x 58”)  
Hearth extension board for end opening. (16” x 27”)  
Telescoping Assembly for use with telescoping chimney caps.  
6S8  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE INSTALLATION  
7
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY COMPONENTS  
1.  
When installing “E” series triple wall chimney system on the B36LA and B36LR, do not mix chimney system  
Use same offset and rise chart for chimney when installing elbows.  
components other than those listed below.  
2.  
3.  
Maintain 2” airspace clearances to combustibles.  
MODEL NUMBER DESCRIPTION  
E48  
E36  
E18  
E12  
EE30  
4-foot chimney section (8-inch-diameter flue).  
3-foot chimney section (8-inch-diameter flue).  
1-1/2 foot chimney section (8-inch-diameter flue).  
1-foot chimney section (8-inch-diameter flue).  
30-degree elbows (package contains two 8 inch diameter elbows). One pair is required  
for each offset. Maximum -- two pairs (4 elbows per chimney).  
Chimney support (required when chimney height exceeds 30 feet).  
Round termination cap for contemporary installation, includes storm collar.  
Round Termination cap for chase installation (includes inlet air telescope).  
0-6/12 pitch flashing for contemporary installation. One required with SC round chimney  
cap on 0-6/12 pitch roof.  
ECS  
LFCC-1  
LFCCL-1  
612  
1212  
6/12 - 12/12 pitch flashing for contemporary installation. One required with SC round  
chimney cap on 6/12-12/12 pitch roof.  
LF-FS-2  
17” firestop spacer-One required at each ceiling or floor level below 20 foot chimney  
height.  
LF-FS-30  
Firestop spacer-for 30º chimney incline through ceiling or floor.  
Square termination for chase installation. Model T8 telescope assembly required but not  
included.  
LFSQT  
T8  
Telescoping Assembly for use with telescoping chimney caps.  
Flat flashing for chase installation (36” x 72”).  
LF-FF  
8
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTING A LOCATION  
CAUTION: Do not install fireplace over carpeting.  
This fireplace does not require any special foundation. If the fireplace is to be trimmed with large stane or brick  
facing, an adequate foundation is required to support these materials. Use figures 5 and 6 as a guide for  
selecting a location and determining the space required for the fireplace.  
The location for the fireplace should be  
adjacent to the load bearing wall and away  
from objects that will create drafts that could  
disturb the normal flow of air into the fire.  
Such objects are frequently opened doors  
and central heat and air outlets and returns.  
See figure 6 which illustrates various types  
of locations and installations and figure 1 for  
additional information concerning installation  
heights, construction details, and methods  
of installation.  
A location that requires cutting the least  
number of joists and rafters for the chimney  
installation will simplify and reduce  
installation cost. The opening required for  
passage of the chimney through the roof,  
ceilings and floors must be 17 inches square  
as indicated by figures 7 and 8. The 17-inch  
square opening provides for the installation  
of the model LF-FS-2 firestop spacer in a  
residential installation.  
Since the pitch of the roof influences the  
opening size required at the roof level, table  
1 should be used as a guide for sizing the  
roof opening.  
Proper selection of a chimney outlet location is also important. Objects such as overhanging or nearby trees,  
adjacent building or embarkments or unusual roof designs can all create air turbulance and interfere with  
chimney performance and cause the fireplace to spill smoke into the room.  
A factory-built fireplace, properly installed in a single story wing of a multi-story builing as shown by figure 9,  
may be affected by environmental factors that will cause poor chimney draft and occasional spillage of smoke  
from the fireplace opening. Although this occurs infrequently, location of the fireplace in the preferred location  
as indicated by figure 9 is recommended.  
If the chimney is to pass through living areas or spaces used for storage, be sure that it will be possible to  
enclose the chimney to prevent contact with and possible damage to the chimney. Elbows may be used to  
avoid obstructions such as electrical wires, water, or sewer pipes, attic fans, heating ducts, etc. Refer to the  
section of this manual concerning chimney offsets for proper elbow installation and use.  
If the fireplace is to be installed in an outside wall, the surrounding walls should be enclosed and insulated.  
failure to properly enclose the fireplace will cause a heat loss and diminish the fireplace efficiency due to  
transfer of heat through the fireplace to the outside.  
9
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FLOOR PROTECTION  
All fireplaces installed over a combustible floor must incorporate a non-combustible hearth extension. It is  
required to protect the floor in front of the fireplace from both radiant heat and sparks.  
Hearth extension dimensions should be determined by using the chart below. use hearth extensions as illus-  
trated in figures 6, 10 and 11 or use an acceptable thickness of a durable non-combustible material with an  
2
equal or greater insulating value than K = .43 Btu in/ft -HR-Fº, or a thermal resistance that equals or exceeds  
R = 1.16. These materials should be covered with a decorative non-combustible veneer.  
NOTE: Any non-combustible material with a K factor value that is less than .43, or whose R value is more than  
1.16 for 1/2” thick material is acceptable.  
HOW TO DETERMINE HEARTH EXTENSION REQUIREMENTS  
The following information is provided to determine required thickness for any non-combustible material when  
2
either the K or R values are known. They are expressed as the following: K = Btu-in/ft -HR-Fº or R = HR-fº/Btu.  
These materials should be covered by a decorative non-combustible material such as tile, brick, stone or slate.  
To determine the thickness needed for a material other than those listed in the chart, use the following formulas  
to calculate that which will be an acceptable equivalent.  
The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc-  
tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of these  
values and the formulas for converting one value to another is as follows:  
C = K divided by the material thickness  
(Example C = .43 divided by 1/2 (.50)  
C = .86)  
K = C multiplies by the material thickness  
(Example K = .86 multiplied by 1/2 (.50)  
K = .43)  
R = The material thickness divided by K  
(Example R = 1/2 (.50) divided by .43  
R = 1.16)  
With either type hearth extension minor shifting of the supporting floor or expansion and contraction may  
eventually cause a crack to develop between the hearth extension and the face of the fireplace. To help  
prevent the crack from developing, the hearth extension materials must be firmly fastened in place. Wall ties  
should be screwed to the face of the fireplace and imbedded in the mortar joints of brick, stone, or other non-  
combustible materials. The metal safety strip packed with the fireplace must be placed beneath the fireplace  
and extended under the hearth extension or into a mortar joint of the hearth extension. In the event a crack  
does eventually develop, the metal safety strip will serve as a barrier to prevent sparks or embers from falling  
from the fireplace onto combustible flooring materials.  
* See figure 6A for an alternate hearth extension using brick only.  
WARNING: THE CRACK BETWEEN THE HEARTH EXTENSIONAND FIREPLACE MUST BE SEALED WITH  
A NON-COMBUSTIBLE MATERIAL. WHEN INSTALLING THE HEARTH EXTENSION, BE CAREFUL NOT  
TO BLOCK THE HEAT CIRCULATING AIR INLETS (LOUVERS, SLOTS, ETC.). SEE FIGURE 6A.  
Wall Protection  
A model WS wall shield or an equivalent must be installed when the closed end of the fireplace is closer than  
24 inches from a wall perpendicular to the face of the fireplace. (see figures 10 and 11). The WS wall shield  
should be attached securely to the wall by driving nails or screws through it into the wall studs. The wall shield  
should be covered by a decorative non-combustible material such as brick, tile, slate, etc.  
The WS wall shield is constructed by 1 inch of Micore CV230 insulation board, manufactured by U.S. Gypsum  
Corporation, covered by a sheet of galvanized metal. An alternate insulating material with a K factor of .43 or  
lower can be used. refer to the preceeding section for instructions for selecting an alternate insulating material.  
WARNING: IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE  
MANUFACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL  
OR FROM FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE  
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRO-  
DUCTIVE HARM. ALSO, OPERATION, INSTALLATION AND SERVICING OF THIS PRODUCT COULD EX-  
POSE YOU TO AIRBORN PARTICLES OF GLASS WOOL FIBERS KNOW TO THE STATE OF CALIFORNIA  
TO CAUSE CANCER THROUGH INHALATION.  
10  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEARANCES  
11  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE INSTALLATION  
12  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE INSTALLATION  
13  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE INSTALLATION  
LOCATION SELECTION  
Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your  
dealer. Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to the  
Parts Diagram and List section of this manual for proper identification of parts.  
Do not substitute parts. Use only parts listed for use with Model MD36I fireplace.  
FIREPLACE INSTALLATION  
1. Refer to Figure 1 for examples of typical fireplace framing.  
2. Be sure the location of the fireplace will provide the required safety clearances as specified by this instruc-  
tion manual.  
3. Set the fireplace in the desired location and be sure it is securely supported and leveled. Install metal  
safety strip for hearth extension as shown by Figures 10, 11, and 12. Check the face of the fireplace with  
a carpenter’s level to make sure the fireplace is plumb. If it is not plumb, plumb it by placing shims under  
the edges of the fireplace.  
4. Block in the fireplace to prevent any shifting of the firebox. Secure the fireplace with nails or screws  
through the flanges located on each side of the fireplace. Install chimney and other fireplace components  
as needed.  
NOTE: Some local codes may require electrically grounding the fireplace and chimney.  
CHIMNEY INSTALLATION  
In order to assure safe and satisfactory performance of the fireplace, it is very important to properly install the  
chimney. This is an important part of the installation and the sections of this manual pertaining to chimney  
installation should be reviewed very thoroughly.  
For your safety, some of the important things to remember in regard to chimneys are listed below:  
11.4Use only parts and accessories labeled for use with this fireplace.  
2. Use only undamaged parts and accessories.  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY INSTALLATION  
3. Enclose the chimney where it passes through the living spaces to prevent contact with and possible damage  
to the chimney.  
4. Install firestop spacers at each ceiling level.  
5. Install the proper chimney cap or chimney housing on the chimney to prevent the entry of rain and debris  
into the chimney and to assure the proper venting of smoke.  
6. Do not use more than four elbows in the chimney.  
NOTE: To select the proper chimney height, refer to Figure 1. The flue outlet must be a minimum of three feet  
above the highest point where the chimney penetrates the roof and a minimum of two feet above all portions  
of the building within ten feet. (see figure 12) If the chimney is to include elbows to offset the chimney, refer to  
the Chimney Offset and Cap Installation section of this manual. There must be at least two inches air space  
between all sections of the chimney and combustible materials between floors.  
1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass  
through. Unless the chimney is to be offset, the point where the center line of the chimney will pass  
through the ceiling and roof can be determined with a plumb line as shown by Figure 15. The fireplace  
should be located in the planned installation position. After the center line is established and a nail is  
driven to mark the point, the opening can be cut if you are satisfied with the chimney location relative to  
ceiling and roof joists and/or any other obstructions. The roof opening center line should be marked by  
driving a nail through the roof from underneath that will penetrate the roof and can be located from the  
rooftop. If the chimney is to penetrate a pitched roof, the hole in the roof must be rectangular instead of  
square and should be sized according to Table1.  
2. Install the firestop spacer as required from beneath the ceiling unless the space above is attic space. In an  
attic, the firestop spacer should be installed at the floor level of the attic. Figure 17. You must have joists  
or headers on all four sides of the spacer and use a minimum of four 8-penny nails to secure the spacer.  
3. To install the “S” series chimney sections, insert the male end of the flue, the smallest diameter pipe, into  
the flue outlet of the fireplace and press down until the snap locks engage. Continue the process, adding  
the chimney sections on top of each other until the chimney is at least six inches above the roof opening on  
all sides. As the chimney sections are installed, check each joint to make sure it is properly locked to the  
previous section. If additional strength of the outer pipe joints is desired, you may use two or three sheet  
metal screws placed through the area where the outer pipes overlap one another. To install these screws,  
drill a 1/8-inch diameter hole through the chimney sections, taking care not to penetrate the inner flue pipe.  
Warning: Be very careful when drilling the holes into the outer pipe. The drill must not penetrate the in1ne5r  
stainless steel pipe.  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY INSTALLATION  
16  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY OFFSET INSTALLATION  
NOTE: If you intend to have a total fireplace installation of more than 30 feet, you must use a chimney support  
at or below 30 feet to support the weight of additional chimney pipe. If it is impossible to nail the chimney  
support to the load bearing framing of the builing at the 30 foot level, the chimney support may be installed at  
a lower level if the height of the chimney above the support does not exceed 30 feet. Effective height of the  
chimney support is 16-3/4 inches. Chimney supports must be installed at 30 foot intervals.  
To install the chimney support, place the crimped end of the flue into the last section of chimney pipe (see  
figure 15). Push down until the outside or inlet air duct of the chimney support overlpas and snaps and snap  
locks the chimney support into the chimney section.  
Nail the support straps tightly to a building frame member or ceiling joist as shown by figure 15. You must use  
at least two 8 penny nails per strap.  
ELBOW INSTALLATION  
NOTE: If triple wall elbow is to be placed directly to the top of the fireplace, it will be necessary to bend a tab  
over located on each of the four inlet air collar brackets. bend these tabs over only when using a triplewall  
elbow to start a chimney run. The tabs may be easily bent with your fingers or pliers. See figure 16A.  
The following are important points that should be observed when installing elbows on the fireplace:  
1. The support straps of all elbows not installed directly on top of the fireplace should be nailed securely to the  
surrounding structure. This allows the support strap to carry the weight of the chimney above the elbow  
and prevents this weight from breaking the elbow or chimney sections apart. See Figure 16.  
2. Elbows should not be used in any combination that inclines the chimney more than 30 degrees from vertical.  
3. The limitations on the quantity of elbows per chimney are as follows: If the total height of the fireplace and  
chimney is — 16' 0" or more — two elbows may be used in the chimney. 21' 0" or more — four elbows  
may be used in the chimney.  
4. The inclined portions of chimneys that pass through living spaces likely to be used for storage should be  
enclosed to avoid contact with and possible damage to the chimney. The minimum air space of two inches  
between the chimney and enclosing materials must be maintained. Figures 17 and 18 illustrates elbow  
installations.  
5. The length of the inclined portion of chimney between elbows must not exceed 6 feet when unsupported or  
20 feet if the chimney is supported at six-foot intervals with support such as metal support straps.  
6. When enclosing the elbows and inclined portions of the chimney, enclosing materials must be installed  
vertically to maintain the required two-inch minimum air space clearance to the chimney at the extremities  
of the offset. It is recommended that enclosing material not follow the inclined portions of the chimney.  
OFFSET INSTALLATION SEQUENCE  
1. Determine the location and amount of offset required, then select the combinations of chimney sections  
and elbows required from the offset chart. Refer to Table 2.  
2. Install the first elbow by placing the crimped end into the mating part of the fireplace or chimney section.  
Push down until the outside or inlet air duct of the elbow overlaps and the snaps lock the elbow into the  
fireplace or chimney section.  
3. Nail the support straps to the framing member with a minimum of two 8-penny nails per strap.  
4. Install the sections of pipe between elbows until the proper number of chimney sections have been installed.  
5. Install the second elbow to return the run of the chimney to vertical.  
6. Nail the support straps of the second elbow to a building frame member.  
7. Continue installing the vertical portion of the chimney.  
NOTE: If the inclined portion of the chimney passes through a floor or ceiling, an SF30 firestop spacer should  
be installed to provide the firestop and support required. Be sure proper spacing in maintained between the  
chimney and combustibles. See Figure 19.  
17  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY OFFSET AND CAP INSTALLATION  
18  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHIMNEY OFFSET AND CAP INSTALLATION  
19  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MCOHDEILMSNCECYHIMNCEYACPAP INSTALLATION  
SPECIAL NOTE: The proper height as previously explained is important to assure proper draft and safety. The  
chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should be  
kept in mind when determining the proper height for the chimney. The chimney should not be extended more  
than 90 inches above the supporting roof structure without additional support. In the case of an “A” frame type  
construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a support  
should be attached to the chimney at the 90 inch level that is strong enough to support a wind load of 3-1/8  
pounds for each inch the chimney extends above 90 inches. The flue outlet must be a minimum of three feet  
above the point where it penetrates the roof. See Figure 12.  
CAUTION: Be careful to avoid electrical shock hazard when contacting wires to the metal chimney components.  
1. Extend the regular chimney sections until the top of the chimney is 4 inches below the total flue height  
desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is  
completed.  
2. Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of  
the flashing under the shingles.  
3. Set the flashing on the roof and scribe a line around the flashing, then cut the top off the flashing by cutting  
1/4 inch below the scribed line. This should increase the diameter of the flashing outlet sufficiently to allow  
the flashing to be placed over the chimney. See Figure 18.  
4. Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the chimney  
to assure that the proper minimum clearances are maintained.  
5. Nail the flashing securely in place with eight nails.  
6. Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess mastic at  
this area to be used in step eight. NOTE: Use pliers and wear gloves when performing step seven to  
minimize the danger of cutting your hands on the edge of the storm collar.  
7. Place the storm collar around the chimney and put the collar together like a belt in belt loops. Slide the end  
of collar under the two loops on the other end with the loops facing up. Overlap the ends of the collar until  
it is tight against the chimney. Bend the free end of the collar back over the loops to hold the storm collar  
securely together. The excess end of the storm collar may be trimmed off.  
8. Slide the storm collar down snugly against the flashing until the excess mastic left in step six is forced up  
into the crack between the storm collar and the chimney. This should make the joint between the flashing  
and the chimney watertight.  
9. Install the chimney cap by placing the cap into matching parts of the last chimney section. Push down until  
the brackets on the bottom of the chimney cap sits on the chimney pipe. Then punch or drill 1/8 inch  
diameter holes in the inlet air duct (chimney pipe) where specified on the brackets and fasten it down with  
the No. 8 screws provided. Do not penetrate the inner stainless steel pipe while installing the screws.  
10. Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts have  
been damaged or bent during installation and that all parts have been installed properly.  
NOTE: The metal used for the chimney cap has a rust protective coating but the cut edges of the parts are not  
protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney  
cap should be detergent washed and painted with a galvanized primer paint.  
20  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS  
NOTE: The use of outside air for combustion is optional unless required by building codes. It is only  
necessary to supply outside combustion air to one side of the fireplace. Use the model OAC4 combustion  
air kit.  
1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air  
assembly should be avoided. These conditions will increase the resistance to the free flow of air through  
the duct. See Figure 22 for methods of installing the outside air for combustion assemblies.  
2. The combustion air assembly should be located at an exterior location, which is not likely to be accidentally  
blocked in any manner. The assembly should be located above the snow line to prevent blockage by snow  
accumulation.  
3. The combustion air inlet assembly should never be mounted in a garage or storage area where combustible  
fumes such as gasoline might be drawn into the fireplace.  
4. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is  
provided by open ventilation.  
5. Do not take combustion air from attic space or garage space.  
21  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MCOODEML OBAUCS4 TCOIOMBNUSTAIONIRAIRAASSSESMEBLMY BLY  
1. Remove the cover cap from the 4 inch outlet opening location on the left or right outside surface of the  
fireplace. DO NOT REMOVE THE COVER IF THE OUTSIDE AIR WILL NOT BE CONNECTED.  
2. Fasten the (4 inch) starting collar over the hole on the left or right side of the fireplace with the four sheet  
metal screws provided. (see figure 22).  
3. Cut a 6 inch diameter opening for model OAC4 in the outside wall covering where the model OAC4 outside  
grille is to be located. (See figure 24).  
4. Select and cut a piece of duct of sufficient length to attach to the fireplace and protrude at least three  
inches beyond the face of the wall to which the OAC4 inlet air box assembly will be attached. The duct may  
be cut with a standard pocket knife. (Use FP-4-U duct for maximum efficiency and safety) Do not use a  
combustible duct. Always use UL listed Class 0 or 1 duct material.  
5. If the duct is the insulated type, push the insulation back from one end of the duct approximately two  
inches. (See figure 25)  
6. Slip the exposed end of the duct over the flange tube of the fireplace.  
7. Place the duct clamp around the exposed end of the aluminum duct.  
8. Slip the band through the housing, then pull the band tight around the duct.  
9. Snap the band locking screw down and tighten it with a screwdriver or nutdriver. (see figure 25)  
10.Nail or screw the combustion air assembly to the surface of the wall.  
NOTE: If the wall covering is brick or stone, use appropriate masonry fasteners. Mount the combustion air  
assembly with “TOP” upward to prevent rain from entering the assembly. Be sure the 6 inch diameter  
opening around the air duct is sealed with insulation material to prevent cold air from entering through the  
wall. If it is necessary to splice the duct, a model 403 duct connector should be installed as described by  
figure 26.  
22  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS APPLIANCE INSTALLATION  
WARNING: Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak  
out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling  
which can cause serious injury or death to its inhabitants. To reduce these risks to a minimum, the following  
important notices and instructions should be read and followed carefully.  
IMPORTANT NOTICES:  
1. The provision for a gas line is intended for connection to a decorative gas appliance which has an automatic  
shutoff device and complies with the Standard for Decorative Gas Appliances for Installation in Vented  
Fireplaces, ANSI Z21.60. If a decorative gas appliance is installed, it must be installed in accordance with  
the National Fuel Gas Code, ANSI Z223.1.  
CAUTION: When a decorative gas appliance is installed, the fireplace damper must be set in the fully open  
position at all times.  
WARNING: THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO  
REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO  
FIREPLACE.  
THE INSTALLER OF THE FIREPLACE AND GAS APPLIANCE MUST DESCRIBE THE OPERATION  
OF THE FIREPLACE AND APPLIANCE TO THE PEOPLE WHO WILL BE OPERATING THEM AND  
LEAVE ALL INSTRUCTION MANUALS WITH THE OPERATOR OF THE APPLIANCE.  
2. An approved gas shut off valve must be located outside the fireplace in an area accessible to the users of  
the fireplace.  
3. All gas piping and fittings must be either steel or malleable iron.  
4. Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces. Check with  
local code authorities before proceeding with the installation.  
5. The gas appliance and all connecting gas piping should only be installed by a licensed gas appliance  
installer. See Figure 11 for the gas line opening dimensions on the fireplace.  
6. The installer should advise the persons who will use the appliance to set the fireplace damper in the full  
open position when the appliance is in use.  
The following instructions only apply to passing the gas line through the fireplace wall. Follow the instructions  
provided with the gas appliance for particular installation instructions regarding that gas appliance.  
1. Remove the side brick from the fireplace and locate the dimple “B” referred to by figure 27.  
2. Tap out a round hole in the brick liner with a hammer by tapping lightly on the recessed area.  
3. Remove the two screws that hold the cover plate on the jacket wrap and discard the cover plate.  
4. Use a screwdriver or similar tool to push the loose insulation out of the tube between the firebox and the  
outer jacket of the fireplace.  
5. Install the gas pipe through the tube between the firebox and jacket.  
6. Attach the gas appliance to the gas pipe according to the instructions provided with the gas appliance.  
7. Pack the insulation removed in step 4 around the pipe to prevent air flowing through the tube either into or  
out of the firebox.  
8. Be sure the gas is turned off at the appliance, then turn the gas on at the cut off valve and test the gas line  
connections for leaks with soapy water solution or a liquid leak detector. If a gas leak is detected, turn the  
gas off immediately and fix the leak. DANGER: Do not use candles, matches or other ignition sources  
when checking for gas leaks. Fuel gases are very flammable and in certain concentrations, explosive.  
Checking for leaks with an open flame may lead to fire or explosion.  
9. Proceed with installation and adjustment of the gas appliance as directed by the instructions provided with  
the gas appliance. If a gas leak is detected, turn the gas off immediately and fix the leak.  
23  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS APPLIANCE INSTALLATION  
TRIM INSTALLATION  
The face of your fireplace may be left exposed or trimmed with any noncombustible material such as brick,  
stone or marble. See Figure 28. If a noncombustible trim is installed, be sure it is fastened snugly to the face  
of the fireplace. A crack between the material and the face of the fireplace could pose a fire hazard and impair  
the proper operation of the fireplace. Blocking the fireplace with framing and attaching the base to the supporting  
floor will reduce the possibility of such a crack developing.  
CAUTION: Do not allow any trim materials to extend closer than 3/8-inch to the vertical edges of the  
firebox opening if you plan to equip the fireplace with glass doors.  
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints  
of masonry trim.  
Combustible material must not be installed below the top spacers of the fireplace or overlap the sides  
of the fireplace face. Seal the face of the fireplace to the surrounding wall with non-combustible caulk or trim  
materials to prevent cold air leakage around the fireplace.  
CAUTION: No trim should block or restrict in any way the flow of air into the air inlets in the face of the  
fireplace. See Figures 28 and 29  
Be sure to provide the required floor protection as described in a preceeding section of this manual. (See  
Figure 10).  
GLASS DOOR INSTALLATION  
This fireplace has been tested and listed for use with Model MGD36B or MGD36PB glass doors. For installa-  
tion of the Model MGD36B or MGD36PB glass doors, see the instructions provided with the doors.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRIM INSTALLATION  
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE  
FIREPLACE FOR B36LAAND B36RA  
NOTE: ON B36LA OR B36RA MODELS, NON-COMBUSTIBLE MAY BE INSTALLED TO  
THE TOP OF THE FIREPLACE OPENING. THIS FACING MATERIAL MUST BE  
FIGURE 28  
SECUREDAND SEALED TO THE FACE OF THE FIREPLACE. FAILURE TO PROPERLY  
SECURE AND SEAL NON-COMBUSTIBLE FACING MATERIALS TO THE FIREPLACE  
CAN CAUSE A POSSIBLE FIRE HAZARD AND WILL VOID THE WARRANTY.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE OPERATION  
WARNING: If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open  
position. (See additional operation information in section titled “Operation Guidelines”.)  
WHICH WOODS ARE BEST?  
Each wood species offers something different in aroma or heat value, and you should consider your needs and  
desires before building your fire.  
Softwoods, like pine, spruce, and fir are easy to ignite because they are resinous. However, a fire built entirely  
of softwoods burns out quickly and requires frequent replenishment. While a softwood fire is not too desirable  
for a long evening, it’s fine in the morning when you want quick warmth, or late in the evening when you want  
a fire that will burn out before you go to bed.  
On occasion when a longer fire is desired, it’s best to combine softwoods with the heavier hardwoods such as  
ash, beech, birch, maple, oak and hickory. These hardwood species burn less rapidly, with shorter flames, and  
produce steady, glowing coals.  
For the most pleasing aroma, you’ll want to burn the wood of fruit trees such as apple and cherry, or nut trees  
such as beech, hickory and pecan. Such wood is generally more expensive, but a little combined with other  
wood, goes a long way. Start your fire with a mixture of softwood and hardwood, then add some fruit or nut  
wood for nostalgic aroma. Since most woods will not burn well when freshly cut, the wood you purchase  
should be reasonably dry. The sizes you buy are dictated by the size of your fireplace. Purchase logs that will  
fit when laid across your grate, and ask that the larger, heavier logs be split. Kindling should be short, easily  
split lengths of softwood, lumber yard or mill scraps, or twigs and branches gathered from your yard.  
HOW TO BUILD A BETTER FIRE  
The first three fires should be of moderate size to allow the fireplace to adjust and the bricks to cure before  
being subjected to larger fires.  
First, make sure your room is well ventilated, your damper open and the flue is unobstructed. Then make sure  
your wood is dry and seasoned. Unseasoned wood burns poorly and coupled with poor ventilation or an  
obstructed chimney, leads to smoking problems.  
If your fireplace is equipped with an outside combustion air assembly, open its combustion air damper by  
pushing upward on the lever located above the firebrick on the corresponding side of the firebox.  
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR  
SIMILAR LIQUIDS TO START OR "FRESHEN UP" A FIRE IN THIS FIREPLACE. KEEP ALL SUCH LIQUIDS  
WELL AWAY FROM THE FIREPLACE WHILE IT IS IN USE. USE OF THIS FUEL CAN CAUSE A SERIOUS  
EXPLOSION.  
Prepare your fire by placing two logs on the iron grate or fire basket, and laying the tinder between them.  
Tinder may be dry scrap paper, twigs, or bark. On top place a small handful of twigs or split softwood kindling.  
Place more dry logs over this base. Keep logs close together, as narrow air spaces between them promote  
better drafts, and heat reflected between adjacent surfaces aids in raising and maintaining combustion  
temperatures.  
You’ll need a minimum of three logs, preferably four, to make a good fire. Add kindling and new logs as needed  
to rekindle a dying fire. New logs should be added at the rear grate after raking the coals toward the front. DO  
NOT OVERFIRE THE FIREPLACE. Overfire conditions may be created by large amounts of kindling, building scraps,  
or other improper fuels.  
Ashes, important because they form a bed of glowing coals, should only be left to accumulate within an inch or  
two of the bottom of the grate. Excess ashes can be used to check a flaming fire; or to “bank” your fire, cover  
the logs with ashes. A “banked” fire will hold glowing coals for 8-10 hours, thereby saving a fire for later use.  
26  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIREPLACE OPERATION  
WOOD VS. FOSSIL FUELS  
Compared to fossil fuels, a full cord of dry hickory weighs about two tons and is approximately equal in heating  
value to a ton of hard coal. On a pound basis, heavy hardwoods have about half the heating value of coal. The  
tabulation shows the relative densities and heat values of a variety of dry woods. Varieties at the top of the list  
(Dogwood) burn longer and those near the bottom (White Pine) ignite and burn quicker. A combination of both  
light and heavy wood is desired.  
SPECIES  
Dogwood  
Hickory  
Oak  
Black Locust  
Beech  
Hard Maple  
Birch  
Apple  
DENSITY  
.70-.79  
.70-.74  
.60-.73  
.69-.70  
.64-.66  
.58-.65  
.55-.64  
.58-.62  
HEAT VALUE  
100-107  
100  
SPECIES  
Ash  
Southern Pine  
Elm  
Cherry  
Douglas Fir  
Spruce  
DENSITY  
.57-.61  
.51-.60  
.50-.59  
.50-.52  
.45-.51  
.41-.44  
.33-.40  
.35-.37  
HEAT VALUE  
81-82  
73-81  
71-80  
70  
86-99  
95-98  
89-91  
83-88  
79-86  
83-84  
64-69  
59  
47-54  
50  
Redwood  
White Pine  
A FEW WORDS OF CAUTION  
Beware of burning certain material in your fireplace. Among these are plastics, poison ivy twigs and stems,  
and chemically treated woods such as discarded poles and railroad ties. These not only create air pollution,  
but can induce extreme irritation for some individuals.  
Use hemlock, spruce, juniper and other resinous woods with caution. They contain moisture pockets which,  
upon heating, “pop” with considerable vigor.  
Always use a fire screen. And always “bank” a fire, or at least push all unburned fuel to the rear of the grate  
before leaving a fire unattended. Do not use this fireplace as an incinerator.  
Because the termination of the chimney above the roof is exposed to wind and cold and the pressure changes  
these and other environmental conditions may cause, a sufficient chimney draft may be hard to establish at  
times. At other times the draft may be sufficiently disrupted to cause smoke to spill from the fireplace opening.  
If problems with chimney draft occur, help start chimney draft before you build a fire by holding a piece of  
burning paper near the flue opening at the top of the firebox to preheat the chimney. If smoke spills from the  
fireplace opening after the fire is burning, open a window on the up wind side of the house that is far enough  
away form the fireplace that the wind will not blow across the fireplace opening, push the burning wood as near  
the back of the fireplace as possible, and if the fireplace is equipped with glass doors, close them.  
DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED, OR SENILE PERSONS  
ALONE WITH A BURNING FIREPLACE.  
27  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE AND SAFETY  
FUEL STORAGE  
Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humidity area. It is  
far better to cut wood and allow it to dry for a year. In all cases, the wood should be stacked so that both ends  
of the sticks are exposed to the air and protected from rain. The drier the wood, the more usable heat produced  
by the fire and less likely rapid accumulation of soot and creosote within the chimney is to occur. See the  
section of this manual concerning chimney maintenance for information concerning the hazards of soot a  
creosote accumulation. Small quantities of wood required for fire tending must be kept at least 30 inches from  
the fireplace.  
DISPOSAL OF ASHES  
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be  
placed on a noncombustible floor or on the ground well away from all combustible materials pending final  
disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained  
in the closed container until all cinder has thoroughly cooled. Ashes should never be placed in a container with  
combustible materials.  
CHIMNEY MAINTENANCE  
Creosote, Formation and Need for Removal: When wood is burned slowly, it produces tar and other organic  
vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively  
cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When  
ignited, this creosote makes an extremely hot fire.  
The chimney should be inspected at least twice a year during the heating season to determine if a creosote  
buildup has occurred.  
If creosote has accumulated it should be removed to reduce the risk of a chimney fire.  
The chimney cap can be removed for inspection, maintenance and cleaning by removing three screws from  
the support legs and lifting upward.  
When the fireplace is first in use, inspect the chimney frequently and clean the chimney any time an accumulation  
is observed on the flue walls. The frequency of these inspections can be increased or reduced appropriately  
after a pattern of accumulation has been established. Please note, however, that changes in the outside  
environmental conditions such as temperature and humidity or changes in the operation of the fireplace can  
lead to rapid buildup of soot and/or creosote.  
To clean the chimney, obtain the services of a qualified and reputable chimney sweep, or remove the accumulation  
with brushes on wooden or fiberglass poles. Do not use metal pipes, chains, wires, etc., to clean the chimney  
because such items can scratch the surface of the stainless steel flue which can shorten the life of the flue and  
provide a rough surface for soot particles to attach to.  
Be sure to cover nearby furnishing and arrange some method of catching soot and creosote particles that may  
fall during the chimney cleaning process. If glass doors are installed on the fireplace, they should be closed.  
Extra caution must be used to avoid damage to the flue damper during the cleaning process.  
In addition to checking and cleaning the chimney on a regular basis, be sure to inspect the chimney before  
starting a fire at the beginning of each heating season. Make sure the chimney is clear from any accumulation  
of soot, creosote or any other debris, and that all joints are intact.  
Martin Hearth & Heating does not recommend chemical cleaners because some may contain elements that  
corrode the metal parts of the chimney or fireplace.  
28  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE AND SAFETY  
FIREPLACE MAINTENANCE  
At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes  
should be removed and the hearth area should be swept as clean as is practical. The slow absorption of  
moisture into the ashes over a long period of time could cause a condition which would be corrosive to the  
metal fireplace parts.  
At the beginning of each heating season, always operate the flue damper and make sure it has not become  
stuck from soot, creosote, etc., during the period of inactivity.  
Keep the lower and upper grille panels clean and free from dirt and lint accumulation at all times to get the  
maximum efficiency from your fireplace.  
As you use the fireplace, expansion and contraction will cause minor cracking of the hearth, back firebrick, and  
side firebrick refractory panels inside the fireplace. This is normal and unavoidable. If the cracks become large  
enough or parts dislodge and metal behind the refractory is exposed, the refractory panels should be replaced  
with new panels that can be obtained from your Martin Hearth & Heating fireplace dealer. See Figure 34.  
GLASS DOOR MAINTENANCE  
For glass door maintenance, see instructions provided with the glass doors.  
CHECKLIST OF DO’S AND DON’TS  
DO’S  
1. Do check with local building officials to be sure the installation of the fireplace complies with all building  
codes and requirements and obtain required building permits. Do plan your installation with safety as you  
primary consideration.  
3. Do use only the prescribed material and parts for the installation of the fireplace.  
4. Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace.  
5. Do trim the face of the fireplace only with noncombustible materials.  
6. Do attach the noncombustible face trim material firmly to the face of the fireplace.  
7. Do block in or fasten the fireplace to prevent the possibility of the fireplace shifting out of position.  
8. Do connect the air circulation blower to a properly grounded and fused electrical circuit.  
9. Do enclose the chimney where it passes through living spaces or spaces accessible for storage purposes  
to prevent contact with and possible damage to the chimney.  
10. Do install firestop spacers at each ceiling level when the chimney is installed in a multistory building.  
11. Do install the proper chimney cap or chimney housing on the chimney to prevent rain and debris from  
entering the chimney.  
12. Do keep all flammable liquids, gases and pressurized containers away form the fireplace.  
13. Do check the fireplace for proper adjustment and operation before leaving it unattended for long periods of  
time.  
14. Do inspect and clean the fireplace chimney regularly.  
15. Do keep the fire screens closed when the fireplace is left unattended to minimize the danger of sparks  
popping out of the fireplace.  
16. Do use the grate furnished with and for this fireplace.  
17. Do start a fire only with paper, kindling or solid composition fire starters specifically designed for starting a  
fire. The use of liquid fire starter can cause an explosion within the fireplace.  
18. Do place all ashes in a metal container with a tight fitting lid and place them on a noncombustible surface  
well away from other combustible materials until they have completely cooled.  
19. Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustible  
materials from the fireplace.  
29  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE AND SAFETY  
20. Do build fires of moderate intensity in the fireplace for the first three fires to allow materials to adjust and  
cure before being subjected to the intense heat of a large fire.  
DON’TS  
1. Don’t allow other installations or operation considerations to take priority over safety considerations.  
2. Don’t attempt to use the fireplace until the installation is complete.  
3. Don’t use unlisted parts and accessories with the fireplace except for special flashings fabricated locally.  
4. Don’t use damaged parts or accessories with this fireplace.  
5. Don’t install the fireplace in an exposed or uninsulated area.  
6. Don’t install the fireplace over carpeting.  
7. Don’t install the fireplace on a poorly constructed base or fail to fasten down or attach the fireplace to  
prevent it from shifting out of position.  
8. Don’t create or allow a crack to develop between the metal face of the fireplace and noncombustible trim.  
9. Don’t use power blowers or air circulation systems with this fireplace that are not specifically recommended  
by Martin Hearth & Heating.  
10. Don’t connect accessory air circulation blowers to improperly fused or ungrounded electrical circuits.  
11. Don’t install the fireplace where flammable or explosive liquids or vapors are likely to be present.  
12. Don’t neglect all the considerations mentioned in this manual concerning clearances to combustibles,  
spacing from obstructions and proper chimney height when selecting the location and installing the chimney.  
13. Don’t allow insulating materials to contact the chimney.  
14. Don’t neglect to apply caulking or mastic to the required joints of the flashing and between the flashing roof.  
15. Don’t dry clothing or other articles near the fireplace.  
16. Don’t store or place flammable liquids, gases or pressurized containers near the fireplace.  
17. Don’t neglect to instruct all responsible persons in the proper and safe operation of the fireplace.  
18. Don’t fail to instruct all persons, especially children and elderly persons, concerning the hazards of improper  
operation and unauthorized tampering with the fireplace.  
19. Don’t use this fireplace to burn paper, cardboard, or other debris.  
20. Don’t neglect to inspect and clean the chimney regularly.  
21. Don’t operate the fireplace with the glass fire screen doors partially open. The doors should always be fully  
open or fully closed.  
22. Don’t use gasoline, kerosene, engine oil, charcoal lighter fluid, or other flammable liquids to start or intensify  
a fire. Using these and similar materials can cause an explosion within the fireplace.  
23. Don’t store fuel supply closer to the fireplace than the minimum spacing required for combustible materials.  
24. Don’t subject the fireplace to the intense heat of a large fire the first three times the fireplace is used, but  
build moderate fires to allow the materials to cure and adjust.  
25. Don’t clean the chimney with metallic devices or chemical cleaners.  
26. Don’t use the fireplace or chimney for venting wood or coal burning heaters or inserts unless approved  
in writing by Martin Hearth & Heating .  
27. Don’t put combustibles within 24 inches of the fireplace opening.  
"WARNING: IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTUR-  
ERS INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR FROM FUEL COM-  
BUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF  
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. ALSO, OPERATION,  
INSTALLATION AND SERVICING OF THIS PRODUCT COULD EXPOSE YOU TO AIRBORNE PARTICLES OF  
GLASS WOOL FIBERS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER THROUGH INHALATION."  
30  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS DIAGRAM AND LIST  
All repair part orders should be placed through your local dealer. To ensure prompt and accurate service,  
please provide the following information when placing a repair part order: Model number of your Appliance,  
Part Name, Part Number, and Quantity of parts needed. See Figure 34.  
Technical Service Department  
2813 W. Mall Drive, Unit B.  
Florence, Alabama 35630.  
Tel. - 1-866-500-5671  
B36RA  
B36LA  
KEY  
MPL  
MPL  
PART NO.  
020270  
Z19901  
014012  
020293  
014048  
029986  
026400  
026391  
021673  
021541  
037390  
037393  
KEY  
MPL  
MPL  
PART NO.  
020270  
Z19901  
021663  
020293  
014048  
029986  
026400  
026391  
021673  
021541  
037390  
037393  
NO. PART NAME  
QTY.  
1
NO. PART NAME  
QTY.  
1
1
2
3
4
5
6
7
8
9
Retainer Side Brick  
1
2
3
4
5
6
7
8
9
Retainer Side Brick  
Retainer  
2
Retainer  
2
Firebrick Side Assy. Right  
Rod Outside Air  
Firebrick Back Assy.  
Hearth Refractory  
Screen Panel  
1
Firebrick Side Assy. Left  
Rod Outside Air  
Firebrick Back Assy.  
Hearth Refractory  
Screen Panel  
1
1
1
1
1
1
1
2
2
Screen Pull  
2
Screen Pull  
2
Rod Screen Weld Assy.  
1
Rod Screen Weld Assy.  
1
10 Panel Upper Ptnd.  
11 Rod Damper  
1
10 Panel Upper Ptnd.  
11 Rod Damper  
1
1
1
12 Damper Weldment  
1
12 Damper Weldment  
1
31  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTENTION  
APPLIANCE INSTALLER:  
PLEASE RETURN THIS INSTRUCTION  
MANUAL TO THE CONSUMER.  
53D9041. Rev 1 03/03  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Clock Radio WS 8056U User Manual
Lincoln Electric Portable Generator SVM103 A User Manual
Lowrance electronic Radio LVR 250 User Manual
LST Smoke Alarm 2251EIS User Manual
Magnavox Flat Panel Television 26MF301B User Manual
Manitowoc Ice Ice Maker K00385 User Manual
McCulloch Snow Blower 96192004000 User Manual
Melissa Toaster 243 028 User Manual
Mellerware Juicer 26300B User Manual
Microsoft All in One Printer C4500 User Manual