8. External alarm contact:  
Indicator flashes if remote transmits a command. If  
indicator does not flash or lights up weakly, replace  
the batteries.  
This input allows you to connect any external alarm  
device with a non-powered NO (Normally Open) or  
NC (Normally Closed) contact. E.g. smoke alarms,  
The battery holder is located inside the remote.  
1
4
2
4
magnetic door/window contacts, flood and temper- The back of the remote can be easily opened using  
ature detectors, etc.  
your fingernails or a small screwdriver. Only use  
3V lithium batteries model CR2016. Push the ARM key  
for more than 3 seconds and release the button; the  
indicator blinks. If batteries are replaced, you’ve to re-  
register with the base station (refer to installation).  
You may connect multiple devices in series to the  
HomeGuard. This allows you to turn your  
HomeGuard into a complete security system with  
built-in telephone dialler.  
3
3
To connect any external security device, use the  
supplied cable with mini-plug or install an equiva-  
lent jack plug on these devices.  
4. SELECTING A SUITABLE LOCATION  
The base station has a so-called passive infrared ele-  
ment that detects any change in temperature with-  
in its range. A certain amount of heat related to  
human beings is detected for an alarm. However to  
achieve the best performance of your HomeGuard,  
note following installation recommendations before  
installing:  
3. WIRELESS KEY FOB REMOTE  
CONTROL KR21 (OPTION)  
ARM: Will put the HomeGuard into the armed position.  
The alarm is instant or delayed. Delayed arming  
allows you to leave the room within 30 seconds or  
enter the room and switch off the alarm within 15  
seconds after entering. The factory default is instant a. It should be located at approx. 170-180cm  
arming (no delay). To change this setting please  
refer to Delayed Arm (7).  
height on a fixed vertical surface e.g.  
wall or cupboard  
DISARM: Switches off and resets the HomeGuard.  
PANIC: If pressed simultaneously will cause an alarm  
instantly.  
b. Choose a location where an intruder may pass  
the monitored area at all time in an early stage  
of intrusion.  
Lights On/Lights Off: These buttons are not used  
with HomeGuard.  
c. Choose a location near to a wall outlet and tele-  
phone socket.  
HOMEGUARD MS8000  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
d. The sensor should not be placed above or near  
heating elements or in front of air-conditioners.  
e. Do not mount the sensor on a metal surface or  
next to electrical equipment such as TV sets or  
computers.  
before, the factory default code is [0000]. You will  
hear three high tones and one low tone as confir-  
mation. The green indicator will start flashing.  
2. Press 2 on the keyboard of the HomeGuard: One  
low tone is given for confirmation.  
3. Press the [ * ] button: One high tone is given for  
confirmation.  
2. Press 5 on the keyboard of the HomeGuard: One  
low tone is given for confirmation.  
Caution:  
4. Enter the first telephone number you selected  
(max. 16 digits). If a dialling pause is required  
(e.g. with a certain type of PABX between 0 and  
the number you want to dialled in order to  
obtain an outside line) press another [ * ] for a  
one second pause. One high tone is given for  
confirmation of each number entered.  
a. Radio equipment (e.g. wireless headphones or  
loudspeakers) working on a frequency band of  
433MHz will not create a false alarm, however,  
these devices will limit the RF range of the  
remote control considerably.  
3. Enter a new 4-digit PIN code: You will get three  
high tones and one low tone as confirmation  
and the indicator stops flashing.  
6. PROGRAMMING OF  
TELEPHONE NUMBERS.  
b. Pets, e.g. dogs or cats, may trigger the alarm,  
and should therefore not be kept in the same  
room as where the activated sensor is mounted.  
You may select up to three telephone numbers to  
be contacted if the alarm is triggered. These num-  
bers may include mobile (GSM) numbers, however  
you are not allowed to use national emergency  
numbers from e.g. police, paramedical, etc.  
The numbers you chose should be have well  
5. Press #: One high tone is given for confirmation.  
6. Press 1 to place the telephone number you just  
entered in memory location 1. One short low tone  
is given and the green indicator stops flashing.  
5. PIN CODE SETTING:  
Your HomeGuard can be operated and programmed  
by using a so-called PIN code (Personal Identification  
Number). The factory default code is: [0000]. To  
avoid unauthorised use, enter your own PIN code.  
informed people, instructed by you and able to help Repeat this procedure with the two other selected  
in case of an alarm (e.g. neighbours, friends, rela-  
tives or your own mobile).  
telephone numbers by pressing 2 and 3 for placing  
these in memory positions 2 and 3 respectively.  
Note: Choose a code you will easily remember,  
since the HomeGuard will recognise this code only  
for further operation.  
To enter telephone numbers:  
Note: All three numbers should be entered. You  
may enter the same number more than once.  
1. Enter your PIN (Personal Identification Number).  
Factory default is [0000]: You will hear three  
high tones and one low tone as confirmation.  
The green indicator starts flashing.  
1. Enter your current PIN (Personal Identification  
Number). If you have never changed this code  
Call Identification:  
If you select telephone numbers of people who’s number  
4
MARMITEK - NICOSHOP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
has been entered by more than one HomeGuard, you can  
transmit an extra audible signal with the pre-recorded  
message in order to identify the HomeGuard calling. The  
factory default is one beep at the end of the message.  
3. Press the ARM button on your remote: One low  
tone is given for confirmation.  
high tones and one low tone as confirmation.  
The green indicator starts flashing.  
4. Repeat step 1-3 for a second up to fourth  
remote if required.  
2. Press 7 on the keyboard of the HomeGuard: One  
low tone is given for confirmation.  
To change the number of beeps (1, 2 or 3):  
1. Enter your PIN  
5. Press any button on your HomeGuard keyboard  
to finalise the registration procedure: One short  
low tone is given and the green indicator stops  
flashing.  
3. Press [ * ] for Delay Arm or # for Instant Arm:  
One tone is given for confirmation and the indi-  
cator stops flashing.  
2. Press 4 on the keyboard  
3. Press 1, 2 or 3 for the required number of  
identification beeps.  
9. SIREN  
If no successive commands are entered within a  
period of 15 seconds, the base station returns to  
normal operation. To restart the registration you  
start the procedure from step1.  
Your HomeGuard is equipped with a built-in siren.  
This siren will frighten intruders so they’ll leave the  
house.  
7. REGISTERING REMOTE  
CONTROLS (HANDSHAKE)  
If you require a so-called silent alarm (without siren),  
you can change the factory default:  
HomeGuard can be remotely controlled by up to  
4 radio remotes (1 piece KR21 supplied). For securi-  
ty reasons, each remote selects a unique code (1  
out of 65.536) after the battery has been installed.  
Before using HomeGuard, the base station has to  
learn this specific code from each remote:  
8. DELAY ARM  
The alarm mode may be activated by either the  
remote control or by the keyboard.  
1. Enter your PIN (Personal Identification Number).  
Factory default is [0000]: You will hear three  
high tones and one low tone as confirmation.  
The green indicator starts flashing.  
If the remote control is used, the HomeGuard arms  
and disarms instantly.  
If you require a delay, in order to allow yourself to  
leave or enter the room before arming or disarming  
the HomeGuard, you may set the HomeGuard to  
Delay Arm:  
1. Enter your PIN (Personal Identification Number).  
Factory default is [0000] see (5): You will hear  
three high tones and one low tone as con-  
firmation. The green indicator starts flashing.  
2. Press 3 on the keyboard of the HomeGuard: One  
low tone is given for confirmation.  
3. Press [ * ] for Siren On or # for Silent Alarm: One  
tone is given for confirmation and the indicators  
stops flashing.  
2. Press 1 on the keyboard of the HomeGuard: One 1. Enter your PIN (Personal Identification Number).  
high tone is given for confirmation.  
Factory default is [0000]: You will hear three  
HOMEGUARD MS8000  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Factory default is [0000]: You will hear three high  
tones and one low tone as confirmation. The green  
indicator starts flashing.  
To generate a panic call: press both PANIC  
buttons at the same time (option).  
10. DE-ACTIVATING THE BUILT-IN  
MOTION SENSOR:  
If you prefer to operate the HomeGuard only by  
To reset the alarm:  
means of the external alarm contact rather than the Press # in the keyboard: You will hear one low tone  
If an alarm has occurred it can be reset by:  
1. The person called pressing 0 on the telephone  
dialler just after the beep(s) in the message.  
2. Disarming the system on the keyboard by  
entering your PIN followed by [ * ]  
built-in motion sensor, you can de-activate the PIR:  
as confirmation and the RED indicator lights up, the  
GREEN indicator will flash during the delay (30 sec-  
onds).  
1. Enter your PIN (Personal Identification Number).  
Factory default is [0000]: You will hear three  
high tones and one low tone as confirmation.  
The green indicator starts flashing.  
After 30 seconds the HomeGuard is armed and will  
generate one low tone for confirmation.  
3. Pressing DISARM on the remote control (option).  
2. Press 6 on the keyboard of the HomeGuard: One To disarm the HomeGuard via the keyboard:  
low tone is given for confirmation.  
Alarm message:  
During an alarm the telephone dialler will dial  
the first number. It will start transmitting the  
pre-recorder message as soon as the last digit  
has been dialled. The message lasts 9 seconds  
and will be repeated twice. The pre-recorded  
message is followed by a beep. After this beep  
the system will wait for call confirmation which  
can be given by pressing 0 on a DTMF (touch tone)  
telephone.  
1. Enter your PIN code: 4 short tones will be gener-  
3. Press [ * ] for activating the PIR or # for de-acti-  
vating the PIR: One tone is given for confirma-  
tion and the INDICATOR stops flashing.  
ated as confirmation.  
2. Press [ * ] : One short tone will be generated and  
the RED indicator will go out.  
11. OPERATING INSTRUCTIONS:  
To arm and disarm the HomeGuard with the  
remote control (option):  
Arm-Disarm  
The HomeGuard may be armed and disarmed by  
the remote control (option) or keyboard.  
1. Press ARM to activate the alarm.  
In case the confirmation is not received, the  
HomeGuard will start dialling the second number  
and follow the same procedure. If the second per-  
son does not give confirmation, the third number  
will be dialled.  
2. Press DISARM to de-activate the HomeGuard.  
To activate the security system from the key-  
board (always delayed):  
If you use the remote, the arming and disarming  
may be instant of delayed, depending on the set-  
tings of the HomeGuard.  
Enter your PIN (Personal Identification Number).  
6
MARMITEK - NICOSHOP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE:  
the battery if required.  
Instruct the person who’s number has been entered  
to give the confirmation 0 just after the beep(s).  
Since telephone answering machines or voice mail  
facilities will not generate the confirmation, these  
will be ignored. It is recommended to do a test with  
the people involved in order to let everyone get  
aquatinted with the system.  
Check if no other devices interfere on the same  
frequency e.g. wireless headphones etc.  
5. PIR or siren do not respond:  
Check that PIR or SIREN has been activated.  
6. The sensor HomeGuard does not react to the  
remote:  
Follow the registration procedure in order to  
lock in the remote.  
12. TROUBLESHOOTING:  
1. The base station does not react at all, the green  
indicator is not on:  
Check that the indicator on the remote comes  
on. If not, replace the battery  
Check the power supply and/or the replace the  
back-up battery.  
7. Any other malfunction:  
Disconnect the HomeGuards from mains and  
back-up battery. This will reset the HomeGuard.  
Re-install the HomeGuard according to the  
instruction manual.  
2. The telephone dialler does not dial out:  
Check that the telephone plug is connected  
properly  
Check that the telephone outlet is responding  
to a normal analog telephone.  
Do not open the power supply or  
HomeGuard. No serviceable parts inside!  
3. False alarms:  
Reposition the HomeGuard, away from heating  
elements, direct sunlight, etc.  
Check that no pets can trigger the alarm.  
4. Limited range of the remote (option):  
Check the condition of the battery and replace  
HOMEGUARD MS8000  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PIR of sirene reageren niet:  
Ga na of de PIR of SIRENE zijn ingeschakeld.  
DECLARATION OF CONFORMITY  
Hereby, Marmitek BV, declares that this HomeGuard MS8000 is in compliance with the  
essential requirements and other relevant provisions of Directive 1999/5/EC.  
De sensor reageert niet op de  
afstandsbediening:  
Volg de instructies op voor het aanmelden van af-  
standsbedieningen.  
Bij deze verklaart Marmitek BV, dat deze HomeGuard MS8000 voldoet aan de essentiële  
eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.  
Ga na of de indicator op de afstandsbediening aan  
gaat wanneer u op de toetsen drukt. Wanneer dit  
niet het geval is dient u de batterij te vervangen.  
Par la présente Marmitek BV déclare que l'appareil HomeGuard MS8000 est conforme  
aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE  
Hiermit erklärt Marmitek BV die Übereinstimmung des Gerätes HomeGuard MS8000 den  
grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie  
1999/5/EG.  
Bij andere problemen:  
Haal de adapter uit het stopcontact en verwijder  
de back-up batterij. De HomeGuard zal hierdoor  
worden gereset en neemt de oorspronkelijke fab-  
rieksinstellingen aan. Installeer de HomeGuard  
opnieuw met behulp van de aanwijzingen in deze  
gebruiksaanwijzing.  
MARMITEK BV - PO. BOX 4257 - 5604 EG EINDHOVEN - NETHERLANDS  
Maak de HomeGuard en de bijgeleverde  
voedingsadapter niet open.  
Deze apparatuur bevat geen vervangbare  
onderdelen!  
8
MARMITEK - NICOSHOP  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KTM Motorcycle 200 SX User Manual
Lanzar Car Audio Car Stereo System VC5K User Manual
Lasko Fan LAS3300 User Manual
LevelOne Switch VOI 9300 User Manual
Life Fitness Elliptical Trainer X1 XX00 0203 User Manual
Listen Technologies Carrying Case LA 338 User Manual
Lux Products Thermostat 52126 User Manual
Marcum Technologies Film Camera VS560 User Manual
Maretron Marine Instruments DSM250 01 User Manual
Melissa Vacuum Cleaner 640 019 User Manual