| Marley Engineered Products Ventilation Hood GV 16 User Manual | 
| READ AND SAVE THESE INSTRUCTIONS   MODEL GV 16   GABLE MOUNTED   VENTILATOR   READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE   PATTON ATTIC VENTILATOR. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSON-   AL INJURY AND/OR PROPERTY DAMAGE!   Dimensions   7”   RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.   169⁄16”   3213⁄16”   Figure 2 — Dimensions   85⁄8   ” Description   IMPORTANT SAFETY INSTRUCTIONS   The Marley Engineered Products gable mounted attic ventilator is   fully automatic and designed for general ventilating use only in the   attic spaces of houses, apartments and other small buildings. Unit   can be installed behind existing attic louvers to exhaust hot air or   pull in cool air. An accessory dehumidistat can be used with this   unit to automatically activate in the winter to help eliminate exces-   sive moisture.   The ventilator comes complete with mounting brackets, 18”   armored flexible cable, prewired automatic thermostat mounted in   junction box, thermally protected motor, and heavy gauge plated   steel housing.   WARNING:   TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY   TO PERSONS, OBSERVE THE FOLLOWING:   1. Do not use this fan with any Solid-State Speed Control Device.   2. Use this unit only in the manner intended by the manufacturer. If you   have questions, contact the manufacturer.   3. Before servicing or cleaning unit, switch power off at service panel and   lock service panel to prevent power from being switched on accidentally.   4. Installation work and electrical wiring must be done by qualified per-   son(s) in accordance with all applicable codes and standards, including   fire-rated construction.   Unpacking   5. Sufficient air is needed for proper combustion and exhausting of gases   through the flue (chimney) of fuel burning equipment to prevent back   drafting. Follow the heating equipment manufacturer’s guideline and   safety standards such as those published by the National Fire Protection   Association (NFPA), and the American Society for Heating and Air   Conditioning Engineers (ASHRAE), and the local code authorities.   Unpack carefully. Inspect for loose, missing or damaged parts. In   the event of missing components or hidden damage, immediately   contact your distributor or the delivering carrier concerning dis-   crepancies. The motor/fan assembly has been carefully factory-   balanced. Care should be taken when handling to avoid damage   resulting in unnecessary vibration and noise.   Specifications   MOTOR   BLADE   RPM DIA.   MAX   ATTIC AREA   MIN. INTAKE   REQUIRED   CFM VOLTS WATTS AMPS HP   SHUTTER   *1520   1860   120   120   255   250   2.6   2.6   1/5   1/5   1100   16” STD. WOOD   LOUVER   2170   Sq. Ft.   5.1 Sq. Ft.   1115   16”   METAL   LOUVER   2656   Sq. Ft.   6.2 Sq. Ft.   * H.V.I. Certified at 0.03” Static Pressure   Download from Www.Somanuals.com. All Manuals Search And Download.   MAINTENANCE   4. See Fig. 7 for wiring dehumidistat to ventilator.   WARNING: MOTORS ARE THERMALLY PROTECTED   AND   AUTOMATICALLY   TEMPERATURE   CON-   120V, 60 Hz   SUPPLY   TROLLED AND MAY START WITHOUT WARNING.   THEREFORE, MAKE CERTAIN THAT POWER SOURCE   IS DISCONNECTED BEFORE ANY ATTEMPT TO SER-   VICE OR DISASSEMBLE ANY COMPONENTS! IF   POWER DISCONNECT IS OUT-OF-SIGHT, LOCK IT IN   THE OPEN POSITION AND TAG TO PREVENT APPLI-   CATION OF POWER.   WHITE   TO FAN   MOTOR   GROUND   BLACK   THERMOSTAT &   JUNCTION BOX   ASSEMBLY   Lubricate motor every 6 months using SAE 20 non-detergent oil.   Insert 2-3 drops of oil in the oiling hole on the back plate of the   motor.   DEHUMIDISTAT   Figure 7 — Wiring Diagram for Dehumidistat   5. Replace cover to thermostat/junction box.   OPERATION   TROUBLESHOOTING CHART   WARNING: ITEMS MARKED WITH AN ASTERISK (*)   SHOULD BE PERFORMED ONLY BY EXPERIENCED AND   QUALIFIED PERSONNEL.   Set automatic thermostat to meet your requirements. The ther-   mostat has an adjustable range from 60º to 120º and operates on   a 15º differential. For example, factory setting is 100º. At this set-   ting, as soon as temperature reaches 115º, thermostat will close   and start ventilator. When temperature has been reduced to 100º,   thermostat will open and ventilator will stop. Dial pointer may be   set at temperature that is best for local conditions.   NOTE: Remember the 15º differential. If dial point is set on 120º,   ventilator will start at 135º and operate until temperature has been   reduced to 120º, a difference of 15º. (See Figure 8.)   SYMPTOM   POSSIBLE CAUSE   CORRECTIVE ACTION   Excessive   noise.   1. Propeller blade contacting   housing.   2. Foreign material inside   housing.   1. Realign or replace.   2. Clean.   3. Motor loose.   3. Secure properly.   4. See Maintenance section.   5. Clean.   4. Motor needs oiling.   5. Dirt accumulation on pro-   peller, causing imbalance.   Insufficient   air flow.   1. Not enough eave vents to   provide make-up air.   2. Clogged screen.   1. See installation section.   2. Clean or replace.   Unit fails to   operate.   1. Blown fuse or open cir-   cuit breaker.   2. Defective motor.   *1. Replace fuse or reset cir-   cuit breaker.   *2. Replace.   60ºF   F A N 3. Improper setting of ther-   mostat. (REMEMBER THE   15º DIFFERENTIAL)   *3. See Operation section.   4. Defective thermostat.   *4. Replace   Figure 8 — Thermostat   90   O F F 120   Download from Www.Somanuals.com. All Manuals Search And Download.   PARTS LIST   REF. NO.   DESCRIPTION   QTY.   1 2 FAN BLADE ASSEMBLY   SHROUD ASSEMBLY   SHROUD   POP RIVET, 1/8 X 1/8 STEEL   SCREW 1/4”- 20 X 1.5”   MOTOR BAND   1 1 1 8 3 +   4 +   5 *   6 +   7 +   8 9 +   10   11   12   13 *   14   15   16   * STANDARD HARDWARE ITEM AVAILABLE   LOCALLY   + NOT AVAILABLE AS A REPLACEMENT PART   † ITEM NOT SHOWN   2 1 4 1 8 1 1 1 1 1 1 1 1 1 4 8 1 MOTOR BRACKET   SPEED NUT, 1/4 X 20   RIVET, 1/8 X 5/32 STEEL   MOTOR, PSC 115V 1/5 HP   BOOT, CAPACITOR TERMINAL COVER   CAPACITOR, 4 MFD, 370 VAC   KEPS NUT, #8-32   CUP, BX   CONDUIT, FLEXIBLE   THERMOSTAT ASSEMBLY   BX CONNECTOR   ANTI SHORT BUSHING   MOUNTING BRACKET   SCREW #8 X 3/8” TYPE AB   INSTRUCTION SHEET   17 +   18   19   20 *   21 †   HOW TO ORDER REPAIR PARTS   In order to obtain any needed repair or replacement   parts, warranty service or technical information, please   contact Marley Engineered Products Service Center toll-   free by calling 1-800-642-HEAT.   When ordering repair parts, always give the informa-   tion listed as follows:   SPX Corporation   470 Beauty Spot Rd. East   Bennettsville, SC 29512 USA   1. The Part Number   2. The Model Number   3. The Part Description   4. Date of Manufacture   Part No. 5200-2550-000   PPD 035   3-00   Download from Www.Somanuals.com. All Manuals Search And Download.   |