Installation Instructions  
LP-200012UL Gas Detector  
Instructions  
Please follow these instructions to connect the LP-200012UL to the NMEA 2000 network via a Maretron SIM100  
Switch Indicator Module. The wiring diagram appears in Figure 1 on the reverse side of this page. The diagram  
shows a connection to channel #1, but connections to other channels are similar.  
1. Connect the LP-200012UL power terminals to a 12VDC supply that is independent of the NMEA 2000  
network power supply, as shown in Figure 1. Powering the unit separately from the NMEA 2000 network  
allows the detector to work even when the NMEA 2000 network is powered off.  
2. Connect the two alarm contact terminals to a free switch channel on the SIM100. The example in Figure 1  
shows the detector connected to switch channel 1, terminals SW1A and SW1B. Note: The detector’s  
protective cover must be removed to perform this function.  
3. Use a Maretron DSM250 display (firmware 1.3.5 or higher), the DSM250 Viewing function of Maretron  
N2KAnalyzer software, or other Maretron display product capable of configuring the SIM100 to set the  
switch channel mode (indicated as “Channel #x Mode” on the DSM250) for the appropriate channel to the  
“End of Line Resistor” setting. For this example, you would set “Channel #1 Mode” to “End of Line  
Resistor”.  
4. Supply Power to the NMEA 2000 network and to the LP-200012UL and verify that the switch channel  
indicates an “off” (normal) state using Maretron N2KView software, N2KAnalyzer, or other product  
capable of displaying switch indicator state.  
5. Perform a test using a gas source (cigarette lighter without a flame) applied in front of the LP-200012UL  
and verify that the switch channel indicates an “on” (alarm) state during the test.  
6. Disconnect either of the two alarm wires between the LP-200012UL and the SIM100 and verify that the  
switch channel indicates an “error” state.  
7. Reconnect the alarm wires to the SIM100 and verify that the switch channel indicates an “off” (normal)  
state.  
WARNING: The LP-200012UL is shipped with an 8Kend-of-line resistor installed between the  
alarm contact terminals. Do not remove the resistor; it allows an indication if the wires are  
inadvertently disconnected between the LP-200012UL and the SIM100.  
(continued on reverse)  
Copyright © 2011 Maretron, LLP All Rights Reserved  
P/N: M001807 Rev.1.3 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Leica Digital Camera 18115 User Manual
Lenovo Computer Monitor L195 WIDE User Manual
Liebherr Refrigerator 110309 7084282 01 User Manual
LOREX Technology Webcam VQ1232 User Manual
Mackie Speaker SRM1801 User Manual
Makita Drill 6510LVR User Manual
Makita Power Hammer HM0810B User Manual
Makita Saw 5044KB User Manual
MB QUART Car Speaker MBQ12SB4 User Manual
Memorex CD Player MP3848 User Manual