IMPORTANT
WATER LEVEL CHECK INSTALLATION NOTICE
Q-0130, Q-0210, Q-0270, QM-45, QM-100
Water Level Check
The water float valve setting may change during shipping. Verify the water level is correct at initial startup.
Check the water level while the ice machine is in the freeze cycle and the water pump is running. The
correct water level is 3/8² (9.5mm) to 1/2" (12.7mm) below the top of the standpipe. A black line is present
to indicate the correct level. The water level is set correctly when water is slightly below or contacts the
black line during the freeze cycle. Use the following procedure to check the water level:
Set water level 3/8” to 1/2²
(9.5 to 12.7 mm) below top of
Siphon Cap
standpipe. Water must be slightly
Standpipe
below or contacting the line.
3/8” (9.5mm) to
1/2” (12.7mm)
Correct Water Level
1. Verify the ice machine is level.
2. Remove the siphon cap from the standpipe.
3. Place the main ON/OFF/WASH toggle switch to the ON position and wait until the float valve stops
adding water.
4. Observe the water level:
· If the water level is correct, continue with step 5.
· If the water level is incorrect, bend the float stem until the water level contacts or is slightly
below the black line (3/8² to 1/2" [9.5mm to 12.7mm] below the standpipe).
5. Move the main ON/OFF/WASH toggle switch to the OFF position. The water level in the trough will
rise above the standpipe and run down the drain.
6. Replace the siphon cap on the standpipe and verify the water level and siphon action by repeating steps 3
through 5.
Download from Www.Somanuals.com. All Manuals Search And Download.
|