Manitowoc Ice Ice Maker E 0600 User Manual

E-0600 STACKING KIT  
Installation Instructions  
1. Installation of E-0600 Series Ice Machine and Storage Bin:  
A. Open bin carton, lay carton on its side, and remove cardboard liner from inside bin. Place the liner on the floor in  
front of the carton and slide the bin onto the liner. Attach four bin legs, set the bin upright, and check for damage.  
Move bin to the set-up location and level. The legs are ad justable for leveling. If the legs are not used, use shims  
to level the bin. The NSF (National Sanitation Foundation) requires that a bin not on legs m ust be sealed to the  
floor using mastic around the entire perimeter on the bottom of the bin.  
B. See service manual for uncrating and inspection of both ice machines.  
C. Remove the top cover from the lower ice machine.  
D. Place the control bulb bracket on the back edge of bin, in the center (see FIG. 4).  
E. Place cover from E-0600 kit on ice machine and replace screws. Set ice machine on the bin squarely.  
F. Remove front panel, top cover, and end panel from second ice machine.  
2. Thermostat Control Installation (see FIG. 2):  
A. Remove thermostat control from E-0600 carton. Locate control on partition panel, under tim er box and toggle  
switch. Mark two hole locations on panel using bracket holes as a guide. Drill two 1/8” holes and m ount control  
to partition panel with two sheet metal screws.  
B. Wiring Control (see FIG. 2 and FIG. 3).  
a.  
Remove white plug located on partition panel (ice making compartment) underneath timer box and insert  
leads from thermostat control through partition panel into com pressor  
7/8” bushing from kit. Insert two wire  
compartment. Run leads up to and through smaller of the two bushings in partition panel and into timer box (see FIG.  
2).  
Remote and water m achines: See FIG. 2. Air m achines: See FIG. 3. Rem ove lead wire marked #16 from  
toggle switch and connect to one lead from thermostat with double quick-connect from kit. Connect other  
lead from thermostat to center quick-connect on toggle switch.  
C. Place ice machine end panel and cover back on and set machine on top of first machine, carefully and squarely.  
D. Remove the ice chutes and damper doors from upper and lower ice machines.  
E. Remove the water curtain from the lower ice machine.  
F. Pass the thermostat bulb through the ice chute opening in the upper machine (see FIG. 4).  
G. Remove the screw on the bin switch housing and place a plas tic clamp on the thermostat tubing. Put the housing  
screw through the clamp and replace screw and clamp to housing (see FIG. 4).  
H. Remove the right-hand water curtain hanger screw and put a plastic clam p on the therm ostat tubing. Carefully  
bend the tubing back to the evaporator position. Mount the clamp and curtain hanger back to original position.  
I. Remove the right-hand harvest rack bracket screw and pl ace a plastic clamp on the thermostat tubing. Put screw  
through clamp and mount clamp to the harvest rack.  
J. Feed the tubing through the right-hand corner of the ice chute opening. Carefully bend the tubing straight back to  
the bin wall and then over to the plastic clam p on the br acket. Slide the bulb into the clam p on the bracket and  
tighten the screws. Place a plastic clamp over the tubing and attach to the base of the machine with a sheet metal  
screw.  
K. Replace the lower ice m achine water curtain. Make sure the curtain can open and close freely without hitting on  
the control tubing. If the curtain does hit the tubing, bend tubing enough to allow the curtain to pass.  
3. Installation of Stacking Kit Ice Chutes (see FIG. 5 and 6):  
ove the water pump from the lower ice m achine. Take the water pump and slide it up and off the mounting  
A. Rem  
studs. Rem ove electrical plug from socket. Lift the pump out of the water trough and disconnect the plastic  
tubing. Reverse these steps for later installation.  
B. Place ice chute “A” in lower ice chute opening in base.  
Manitowoc Ice, Inc.  
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA  
8000893  
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879  
Sheet 1 of 2  
Rev. 06/06/01  
C. Make sure the bin control tube has clearance between the base opening and ice chute.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lanzar Car Audio Car Amplifier MXA1600 User Manual
Lenoxx Electronics Ventilation Hood Ventilators User Manual
LG Electronics Freezer GR S552 User Manual
Life Fitness Flat Panel Television LCD 0202 04 User Manual
Life Fitness Home Gym SM17 User Manual
Lightolier Indoor Furnishings TCU Series User Manual
Maretron Switch VS 070HG User Manual
Maxtor Computer Drive Pocket Drive User Manual
Memorex Stereo System MX5310 User Manual
Microsoft Computer Accessories 79G 03775 User Manual