Magic Chef Refrigerator MCWC44DZ User Manual

STAINLESS STEEL BUILT-IN WINE COOLER  
WITH DUAL TEMPERATURE ZONES  
AND TOUCH-SCREEN CONTROL PANEL  
INSTRUCTION MANUAL  
Model No.: MCWC44DZ  
To ensure proper use of this appliance and your safety, please read the  
following instructions completely before operating this appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAMES OF THE PARTS  
MODEL NO.: MCWC44DZ  
1) Interior Light  
2) DC Electric Fan  
3) Zone Partition  
4) Inner rear  
5) Wine Shelf  
6) Door Handle  
7) Partition Gasket  
8) Tempered Glass Door  
(Touch-Screen Control Panel is on the front of the Glass Door.)  
SPECIFICATIONS – Model # MCWC44DZ  
44 Bottle Built-In Wine Cooler  
Product Description  
Model No.  
with Dual Temperature Zones  
and Touch-Screen Control Panel  
MCWC44DZ  
Unit Dimensions  
( inches )  
Width  
23.4”  
Height  
34.4”  
Depth  
24.4”  
Net Weight ( lbs)  
104lbs  
EN  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
To reduce the risk of fire, electrical shock,  
or injury when using your appliance, follow  
these basic precautions:  
aWARNINGa  
Read all instructions before using the wine cooler.  
DANGER or WARNING: Risk of child entrapment.  
To avoid the possibility of child entrapment, please take the following precautions  
before throwing out the appliance.  
-
-
Remove all doors from the unit.  
Leave the shelves in place so that children may not easily climb inside.  
Never allow children to operate, play with, or crawl inside the appliance.  
Refrigerants: All refrigeration products contain refrigerants, which under the  
guidelines of federal law must be removed before disposal of product. It is the  
consumer’s responsibility to comply with federal and local regulations when  
disposing of this product.  
Never clean appliance parts with flammable fluids. The fumes can create a fire  
hazard or explosion.  
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity  
of this or any other appliance. The fumes can create a fire hazard or an explosion.  
-Save these instructions-  
INSTALLATION INSTRUCTIONS  
Before Using Your Appliance  
Remove the exterior and interior packing.  
Before connecting the appliance to the power source, let it stand upright for approximately 4  
hours. This will reduce the possibility of a malfunction in the cooling system from improper  
handling during transportation.  
Clean the interior surface with lukewarm water using a soft cloth. (Cleaning instruction on page 8)  
Free-Standing Installation  
This appliance is designed to be installed built-in or free standing.  
Locate the appliance away from direct sunlight and sources of heat (stove, heater, radiator, etc.).  
Direct sunlight may affect the acrylic coating and heat sources may increase electrical  
consumption. Ambient temperature below 68°F (20°C) or above 90°F (32°C) will hinder the  
performance of this appliance. This unit is not designed for use in a garage or any other  
outside installation.  
Avoid locating the appliance in moist areas.  
Plug the appliance into dedicated, properly installed-grounded wall outlet. Do not under any  
circumstances cut or remove the third (ground) prong from the power cord. Any questions  
concerning power and/or grounding should be directed toward a certified electrician or an  
authorized service center. This unit is not designed to be installed in an RV or used with an  
inverter.  
After plugging the appliance into a wall outlet, turn the unit on and allow the unit to cool down for 3  
~ 4 hours before placing wine bottles in the appliance.  
EN  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-In Installation  
The cutout dimension illustrated in figure (A) allows for  
door swing and access to the pull-out shelves when  
installed as a built-in appliance. If installing between  
frameless cabinets, a ½” wide filler strip or side panel may  
be needed on hinge side. The filler strip will act as a  
spacer between the appliance case and adjacent cabinet  
door swing. The width of the opening must include the  
filter panels.  
Note:  
The door should protrude at least 1” beyond the  
surrounding cabinets.  
Figure A  
The cutout depth must be 24”.  
Electrical Connection  
aWARNINGa  
Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is  
damaged, have it replaced by an authorized service center.  
This appliance should be properly grounded for your safety. The power cord of this appliance is  
equipped with a three-prong plug which mates with standard three prong wall outlets to minimize the  
possibility of electrical shock.  
Do not, under any circumstances, cut or remove the third ground prong from the power cord supplied.  
This appliance requires a standard 115 Volt A.C. /60Hz electrical outlet with three-prong ground.  
This appliance is not designed to be used with an inverter.  
The cord should be secured behind the appliance and not left exposed or dangling to prevent  
accidental injury.  
Never unplug the appliance by pulling the power cord. Always grip the plug firmly and pull straight out  
from the receptacle.  
Do not use an extension cord with this appliance. If the power cord is too short, have a qualified  
electrician or service technician install an outlet near the appliance. Use of an extension cord can  
negatively affect the performance of the unit.  
If any problems with the appliance persist, please contact our Customer Service Dept. to consult with  
a representative at 888 775-0202 or visit our website to request warranty service at  
EN  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLIANCE FEATURES  
Touch-screen Control Panel  
Touch-screen control panel is on the front of glass door for convenient temperature reading and  
setting. You can easily read the zone temperature without opening the door and control your unit  
just by touching the screen. For details of temperature setting, please see “Operating Your  
Appliance”. (pg. 6-7)  
Two Temperature Zones  
There are two zones in this appliance divided by a partition.  
Each zone has its independent temperature control and display.  
The upper zone can hold up to 16 bottles.  
The lower zone can hold up to 28 bottles.  
Interior Light  
Each zone has its own interior light, which can be switched on or off by pressing the pad  
(light)  
on the control panel. Long-life and high efficiency LEDs are installed for durability and energy  
efficiency.  
Upper Zone  
There are two wine shelves of full depth in the upper zone. Each shelf can holds up to 8 bottles  
with the bottle necks alternating front to back.  
The second supporting guide in the upper zone (counted from top, see illustration “A” on this  
page) is not designed for wine shelves.  
Lower Zone  
There are also two wine shelves of full depth in the lower zone. Each shelf can holds up to 8  
bottles with the bottle necks alternating front to back.  
The bottom rack in the lower zone, which consists of two stories, each holds up to 6 bottles with  
bottle necks facing the front (see illustration below on this page).  
Engaged Wine Shelves  
All the wine shelves have tabs to engage the cabinet on both sides.  
Any of the shelves can be removed to accommodate larger bottles.  
To Remove a Shelf:  
Remove all bottles from the shelves.  
Lift the shelve upwards and then gently pull out the shelves.  
To Replace a Shelf:  
Place the sides of the shelves back onto the supporting guides of the cabinet and push back until  
the shelf tabs slide into place.  
NOTE: Ensure that the tabs are firmly engaged in place before storing any bottles.  
EN  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING YOUR APPLIANCE  
Temperature Control and Display  
1. The temperatures in upper zone and lower zone can be independently controlled and displayed.  
2. The temperature in either zone can be controlled between 39°F to 61°F (4to 16). (The zone  
temperature may have a tolerance of +/-5°F (+/-3) from setting depending on different loading  
and ambient conditions.)  
3. The temperature display, indicator , control pads  
(left side) are for upper zone of the wine cooler.  
4. The temperature display, indicator , control pads  
(right side) are for lower zone of the wine cooler.  
(warmer) and  
(colder) near the symbol  
(warmer) and  
(colder) near the symbol  
5. The indicators  
and , and the control pads  
(lock) and  
(light) are for both zones.  
Indicators Lights  
When lit, the  
indicator light indicates that the unit is in the “Stand by” mode.  
When lit, the indicator light indicates that all of the control pads are locked and no  
adjustment can be made to the unit.  
When lit, the indicates that the corresponding zone is in the refrigeration cycle (compressor  
is running). The indicator will go off once the desired temperature is reached. Note: The  
light will remain on and the compressor may continue to run for several minutes after  
the desired temperature is reached.  
Standby  
1. When the unit is plugged in all of the display indicators will light for 3 seconds and an audible  
beep will be heard. The unit will automatically resume the previous settings from when the unit  
was unplugged. If the unit was previously in the “Stand By” mode when unplugged it will resume  
in the “Stand By” mode and the  
indicator will be lit.  
2. You can manually set the unit to the “Stand By” mode by pressing and holding both the  
pads simultaneously of the lower zone located on the right side of the control panel for  
and  
approximately 3 seconds. The control pad must be “unlocked” to set the unit to the “Stand By”  
mode. The  
indicator light will illuminate to confirm this setting.  
Lock and Unlock  
The lock feature is designed to prevent the settings of your wine cooler from being adjusted  
accidentally. In order to adjust any of the settings you must unlock the control panel by pressing the  
“lock” pad for approximately 3 seconds. Once the unit is unlocked an audible beep will be heard and  
the “lock” indicator light will go out.  
If no selection is made to adjust the unit in approximately one minute the control panel will  
automatically return to the “lock” mode.  
To lock the unit manually press the “lock” pad.  
EN  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temperature setting  
Unlock the control panel by pressing the pad for approximately 3 seconds. Once the control  
panel is unlocked an audible beep will be heard and the indicator will go out.  
Under normal conditions the temperature display indicates the current temperature of the  
corresponding zone. When adjusting the temperature, the temperature display will flash to  
indicate that the temperature is being adjusted.  
The temperature in both upper zone and lower zone can be set independently by pressing  
(warmer) or  
(colder) pads that correspond to desired zone. The temperature range of  
both zones can be set between 39°F to 61°F (4° to 16°) +/- 5°F.  
When the pad  
(warmer) or  
(colder) is pressed, the temperature displayed will increase  
(warmer) or (colder) is pressed  
or decrease in an increment of one degree. If the pad  
and held for 2 seconds, the temperature displayed will increase or decrease in a speed of one  
degree per half second.  
Once you have adjusted the upper or lower zone to the desired temperature, release the  
temperature pad. At this time the temperature displayed will flash for approximately 3 seconds  
to confirm the selected temperature. Once the display stops flashing the temperature display  
will indicate the current temperature of that zone.  
Note:  
The temperature display can be changed between Celsius and Fahrenheit by simultaneously  
pressing and holding both pads (warmer) and (colder) for the upper zone for  
approximately 3 seconds. This unit cannot be in (Lock) mode to perform this operation.  
Interior Light  
To turn on / off the interior light, press the  
(Light) pad. The unit cannot be in the (Lock) mode to  
perform this operation. Note: The light will turn on / off after the touch pad is released.  
AUTOMATIC DEFROST  
There is no need for manual defrosting of this appliance due to automatic defrosting function.  
The ice build-up on the inner back wall during compressor operation will be automatically  
defrosted in a compressor off cycle.  
When defrosting is in process, the indicators for both zones will go off, and the circulation fans  
for both zones will run.  
Defrost water will drain out passing through the drain outlet in the inner back wall into a drain pan  
located above the compressor, from where it evaporates.  
EN  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
Cleaning Your Appliance  
Upon installation of your new appliance, it is recommended that it be cleaned thoroughly.  
Turn off the appliance first and then unplug the unit from the wall outlet.  
Remove all contents.  
Wash the inside with a damp warm cloth soaked in lukewarm water and baking soda solution.  
The solution should be about 2 tablespoons of baking soda to a quart of water.  
Be sure to keep the door gasket (seal) clean to keep the unit running efficiently.  
The outside of the appliance should be cleaned with mild detergent and warm water.  
Dry the interior and exterior with a soft cloth.  
Dust or anything else blocking the vent may hinder the cooling efficiency of the appliance.  
Vacuum the vent if necessary.  
Vacation Time  
Turn off the appliance first and then unplug the unit from the wall outlet.  
Remove all the contents.  
Clean the appliance.  
Leave the door open slightly to avoid possible formation of condensation, mold, or odors.  
Short vacations: Leave the appliance operating during vacations of less than three weeks.  
Long vacations: If the appliance will not be used for several months, remove all content and  
unplug the power cord. Clean and dry the interior thoroughly. To prevent odor and mold growth,  
leave the door open slightly: blocking it open if necessary.  
Moving Your Appliance  
Turn off the appliance first and then unplug the unit from the wall outlet.  
Remove all the contents.  
Securely tape down all loose items inside your appliance.  
Tape the doors shut.  
Energy Saving Tips  
The appliance should be located in the coolest area of the room, away from heat producing  
appliances or heating ducts, and out of the direct sunlight.  
Ensure that door is closed when the appliance is turned on.  
EN  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
You can solve many common appliance problems easily, saving you the cost of a possible  
service call. Try the suggestions below to see if you can solve the problem before calling for  
service.  
PROBLEM  
Appliance does not operate.  
POSSIBLE CAUSE  
Not plugged in.  
The circuit breaker tripped or a blown fuse.  
Temperature control is set too warm. Turn the  
control to a cooler setting and allow several hours  
for the temperature to stabilize.  
Temperature inside the appliance is too warm.  
Door is kept open too long or is opened too  
frequently. Warm air enters the appliance every  
time the door is opened. Open the door less  
often.  
The door is not closed completely.  
The door gasket does not seal properly.  
The appliance has recently been disconnected  
for a period of time. 4 hours are required for the  
appliance to cool down completely.  
Temperature inside the appliance is too cold.  
Vibrations.  
Temperature control is set too cold. Turn the  
control to a warmer setting and allow several  
hours for the temperature to stabilize.  
Check to assure that the appliance is on a level  
surface.  
The appliance is touching the wall. Re-level the  
appliance and move it from the wall.  
If continued vibration occurs, turn off the  
appliance and unplug the power plug. Contact  
Customer Service Dept. for further assistance.  
Door is slightly open.  
Door is kept open too long, or is opened too  
frequently. Open the door less often.  
The door is not sealed properly.  
Door is slightly open, causing cold air from inside  
the appliance to meet warm moist air from  
outside.  
Moisture forms on inside appliance walls.  
Moisture forms on outside of appliance.  
The door will not close properly.  
Abnormal display on control panel  
The appliance is not on a level surface.  
The gasket is dirty.  
“E1” on display for upper zone – error of  
temperature sensor for upper zone.  
“E2” on display for lower zone – error of  
temperature sensor for lower zone.  
“E3” on display for upper zone – error of DC  
electric fan for upper zone.  
“E4” on display for lower zone – error of DC  
electric fan for lower zone.  
If any of above errors happens, please contact  
Customer Service Dept. for further assistance.  
Do not attempt to repair it yourself.  
EN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appliance Warranty  
MC Appliance Corporation warrants each new appliance to be free from defects in material  
and workmanship and agrees to remedy any such defect or to furnish a new part(s) (at the  
company’s option) for any part(s) of the unit that has failed during the warranty period. Parts  
and labor expenses are covered on this unit for a period of one year after the date of  
purchase. In addition, MC Appliance Corp. warrants the compressor (parts only) to be free  
from defects in material and workmanship for a period of 5 years. The consumer is  
responsible for all labor and transportation expenses related to the diagnosis and  
replacement of the compressor after the initial one-year warranty expires. If in the event that  
the unit is determined to be non-repairable under the terms of this warranty, the consumer is  
responsible for all transportation expenses to return the unit to our factory prior to receiving a  
refund. A copy of the dated sales receipt / invoice is required to receive warranty  
service or a refund.  
This warranty covers appliances in use within the continental United States, Puerto  
Rico and Hawaii. The warranty does not cover the following:  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Damages due to shipping damage or improper installation.  
Damages due to misuse or abuse.  
Content losses due to failure of the unit.  
Inside components such as door panels, door shelves, racks, light bulbs, etc.  
Punctures to the evaporator system due to improper defrosting of the unit.  
Repairs performed by unauthorized service agents.  
Service calls that do not involve defects in material and workmanship such as  
instruction on proper use of the product, door reversal or improper installation.  
Replacement or resetting of house fuses or circuit breakers.  
Failure of this product if used for other than for its intended purpose.  
Disposal costs for any failed unit not returned to our factory.  
Any delivery costs incurred as the result of a unit that fails to perform as specified.  
ƒ
ƒ
ƒ
ƒ
This warranty is in lieu of all warranties expressed or implied and no representative or  
person is authorized to assume for us any other liability in connection with the sale of  
this product. Under no circumstances is the consumer permitted to return this unit to  
the factory without prior written consent from MC Appliance Corporation.  
Model  
Parts  
Labor  
Compressor Type of Service  
(part only)  
MCWC44DZ  
One-Year  
One-Year  
Five-Year  
In-Home  
For Service or Assistance please call 888 775- 0202. Or visit us on the web at  
www.mcappliance.com to request warranty service.  
EN  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lathem Power Supply PS8 2412 User Manual
Lenmar Enterprises Battery Charger BCV636 User Manual
Lenovo Laptop 06472BU User Manual
Lenoxx Electronics Air Conditioner HS32 Series User Manual
LevelOne Network Router WBR 3402TX User Manual
LG Electronics Car Speaker MFL68001401 User Manual
LG Electronics Dehumidifier ZD30 User Manual
Lincoln Electric Welder SVM151 A User Manual
Melissa Styling Iron 635 122 User Manual
Memorex Stereo System MX4139 User Manual