Magenta Car Satellite TV System NEC 600 User Manual

MultiView  
NEC 600  
Receiver  
Quick Reference  
&
Setup Guide  
Magenta Research  
128 Litchfield Road, New Milford, CT 06776 USA  
(860) 210-0546 FAX (860) 210-1758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTs.  
Page  
Contents  
Chapter  
1. Specifications...................................................................................................2  
2. Introduction ........................................….........................................................3  
2.1 Overview................................................................................….................3  
2.3 Compatible Cabling ........................................................................…...….3  
3. Setup and Installation.......................................… ......................................….4  
3.1 Cabling Considerations.................................................................................4  
3.2 Making the Connections.....................................................................…......4  
3.2.1 Connections and Setup in General .......................................……......4  
3.3 Video Adjustment……..................................…...................................……...6  
4. Troubleshooting...........................................................................................….8  
4.1 Common Problems ..................................................................................….8  
Appendix A. Cabling Pinouts.........................................…...............................…...10  
Appendix B. Sync Mode…….………………………………………………………….11  
Appendix C. SAP Address….………………………………………………………….12  
Appendix D. Rotary Knob menu……………………………………………………….13  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
1. Specifications  
Cable Required: Category 5, 5e, 6 shielded or unshielded twisted pair  
Compliance: CE; FCC Class A, IC Class A  
Video Support: all supported VESA modes to WUXGA (1920x1200), RGBHV,  
HDTV modes including 1080p, 1080i, 720p  
(Note: The NEC 600 does not support component, composite  
or S-video video signals)  
Resolution and  
Refresh Rate:  
At 600 ft. (183 m) or less: a maximum of 1920x1200  
Required Source  
Impedance:  
Video OUT: 75 ohms;  
Audio models: Audio OUT (if any): 600 ohms maximum  
Required Destination  
Impedance:  
Video IN: 75 ohms;  
Audio models: Audio IN (if any): 600 ohms minimum  
Audio  
Characteristics: Full Stereo  
Line Level 600 Ohm Unbalanced  
Serial  
Characteristics: Protocol: Asynchronous; transparent to data format;  
3 wire, baud rate of 9600*  
Connectors:  
(2) RJ-45, (1) DB9M (console only, not for SAP use)  
Temperature  
Tolerance:  
Operating: 32 to 104°F (0 to 40°C);  
Storage: -4 to +140°F (-20 to +60°C)  
Humidity  
Tolerance:  
Up to 80% noncondensing  
Steel  
Enclosure:  
Power:  
N/A—power supplied by display.  
There are no provisions for external power  
Size:  
1.6"H x 6.8"W x 11.4"D (4.0 x 17.3 x 28.9 cm)  
2.2 lb. (1.0 kg)  
Weight:  
*The serial baud rate may be changed internally via SAP commands (see SAP  
communication Protocol User Manual), however it is recommended to use 9600  
baud for best performance.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2: Introduction.  
2. Introduction  
2.1 Overview  
This manual covers the Magenta MultiView™ NEC 600 card slot CAT5 Receiver unit.  
The NEC 600 is intended for use only in compatible NEC displays that have the card  
slot feature. All signals are input directly into the display so external cabling or power is  
not required.  
The NEC 600 card slot receiver supports video, stereo audio and the SAP pollable  
RS232 option on a single CAT5 cable. In order to support all signals a compatible  
SAP series transmitter must be used.  
If video only is all that is necessary, any MultiView series transmitter may be used.  
The NEC 600 can be controlled and configured via the SAP protocol from a SAP  
enabled transmitter.  
For information on the usage of the SAP protocol, please refer to the SAP  
Communication Protocol user manual.  
A CAT5 output is included for daisy chaining.  
An external DB9 connector is used for console access to the receiver and is not  
intended for RS232 serial communication from a transmitter unit.  
The NEC 600 receiver also features integrated skew compensation.  
For information on the respective transmitter unit, please refer to the appropriate  
manual included with the transmitter.  
WARNING  
This equipment is not intended for, nor does it support, distribution  
through an Ethernet network. Do not connect these devices to any sort  
of networking or telecommunications equipment!  
2.2 Compatible Cabling  
CAT5 cabling for the MultiView™ Series must be pinned to the T568B wiring  
specification (see appendix A). We also highly recommend that all CAT5 cables be  
pre-terminated and tested. Cables terminated on-site or in an existing infrastructure  
should be tested before use to ensure compliance with the T568B specification. Using  
incorrectly terminated CAT5 cables can damage the Magenta MultiView™ Series.  
Magenta Research products are compatible with CAT5/5e/6 data cabling as well as  
skew free CAT5/5e cabling manufactured for video applications. Note that some skew  
free CAT5 is specific to a particular vendor and is not compatible with our products.  
Please ensure any skew free CAT5 cable is non-proprietary prior to purchase/  
installation.  
CAT6 cable, due to the manufacture method, can exhibit much greater skew than  
standard CAT5/5e and may require skew compensation beyond what the standard  
product offers. Please contact Magenta Research for assistance.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
3. Setup and Installation  
3.1 Cabling Considerations  
• We recommend mounting and connecting all cabling to the MultiView™ Series  
components before applying power.  
• Make sure that the CAT5 cable you intend to use has been tested to comply  
with the T568B wiring specification (See Appendix A).  
3.2 Making the Connections  
3.2.1 CONNECTIONS AND SETUP IN GENERAL  
This section contains figures showing connections with the specific MultiView™ Series  
models. In general, however, the connection and setup procedure at both transmitter  
and receiver ends is as follows:  
At the transmitter end (refer to the transmitter user guide) :  
1. Connect the source video to the MultiView™ Series transmitter video input port,  
which is an HD15 connector labeled SOURCE IN.  
2. If desired, attach a local monitor via the local monitor port to LOCAL OUT.  
3. Make your audio/serial connections via the 1/8” (3.5mm) audio connector, phoenix ,  
or DB9 serial connector (transmitter model dependent).  
4. Connect the CAT5 cable to the transmitter.  
5. Apply power on the transmitter. The LED should light and, if there’s a local  
monitor attached, a video image should appear on the monitor’s screen.  
At the receiver end (Ensure display is powered off and disconnected from AC  
power):  
1. Remove the left handle on the display and then remove the top option slot blank  
cover.  
2. Insert the NEC 600 receiver into the NEC display slot and secure with the 2 screws  
that secured the blank cover removed in step 1 and replace the handle.  
3. Connect the CAT5 cable to the UTP INPUT connection.  
4. Connect the AC power and turn display on (Note that the NEC display only  
recognizes card slot options only from a cold start (i.e. when the AC power is first  
connected and the display powered on, not in standby mode).  
5. To adjust video levels see Section 3.3.  
6. To set the SAP address for SAP serial transmission, use the two rotary knobs. See  
Appendix C and reference the SAP Communication Protocol user manual.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 3: SETUP & INSTALLATION.  
3.2.2 CONNECTIONS ON THE NEC600 RECEIVER  
Below the NEC 600 connections are detailed:  
Figure 3-1. Connections on the MultiView NEC 600.  
CAT5  
input  
CAT5  
output  
SAP Series Option  
Address Settings/LED  
indicators.  
EQ/SKEW  
Adjustment  
& LED indicators  
See Section 3.3  
See below and  
Appendix C.  
AUX DB9 used for local receiver  
control and/or firmware upgrades.  
This is not a valid display control  
port.  
The NEC 600 card slot receiver does not have any internal jumper or switch settings for  
configuration. Any configuration parameters are changed via the SAP protocol (See the  
SAP Communication protocol user manual for information).  
Sync modes may be changed via the EQ/Skew/Mode knob. See Appendix B.  
In order to set the NEC 600 receiver SAP address for addressable RS232 usage, use  
the two rotary knobs labeled “SAP Address”. See Appendix C for address information.  
The SAP and LNK LED indicators can be used to check SAP connectivity per the  
following :  
LNK Status LED:  
Glowing dim:  
On:  
Valid connection to SAP transmitter.  
SAP session is active.  
SAP Status LED:  
Red Pulse:  
Green Pulse:  
Transmit data activity (to TX unit).  
Receive data activity (from TX unit).  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
3.3 Video Adjustment  
3.3.1 Cable Distance Compensation Settings  
In order to get the highest quality video signals from your MultiView CAT5 Video  
System, please follow the instructions and diagrams below:  
An Image Adjustment Utility is available for download from:  
Simply open in any image browser on a computer.  
If the image file can not be downloaded, use a utility to draw a black box on a white  
background.  
NOTE: TURN KNOB SLOWLY DURING ADJUSMENT PROCEDURE. Turning too  
fast may result in missing the proper EQ setting resulting in picture loss.  
To Reset EQ and Skew values to 0, remove AC power from the display, push and  
hold EQ/Skew Knob in and re-apply power to the display.  
1. Push EQ/Skew knob in once so that the Mode LED is flashing white.  
2. Turn the EQ/Skew knob clockwise until the shadow next to the black box just  
disappears. The brightness in the white area should be the same as the white area  
above and below the black box. The 1-4 Range LED’s will turn on for indicated  
cable distances. Starting from zero feet to 600 may take some time. Please  
continue turning the knob for best picture quality.  
3. Press and release EQ/Skew knob until the mode LED is green or wait 10 seconds.  
Push button  
Adjustment Knob  
Mode LED:  
Green: Normal Operation  
White Flashing: EQ adjust  
Red/Blue/Green flashing: Skew  
adjust  
Range LEDs for  
Skew adjustment  
Solid White: Sync Adjust  
Figure 3-2: Adjustment locations  
Figure 3-3: Image Adjustment Utility—Cable Length EQ  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 3: Setup and Installation.  
3.3.2 Skew Compensation Settings  
The NEC 600 receiver features integrated skew compensation to adjust for signal  
timing differences due to differing pair lengths within the CAT5 cable. Using the delay  
signals, skew may be compensated from 2 to 65 nanoseconds in 2 nanosecond  
increments on each individual color pair.  
An image file is available to assist in these settings. See Figure 3-4 for an example.  
1. To adjust individual colors, press the EQ/Skew knob until the desired color Mode  
LED is flashing. The LED color corresponds to the color channel being adjusted.  
2. Using the image utility, turn knob to add/subtract delay timing until a single  
vertically aligned line of red, green, blue is obtained.  
3. When complete press EQ/Skew knob until the Mode LED is green or wait 10  
seconds .  
Not all colors will have the same delay settings.  
Figure 3-4: Image Adjustment Utility—Skew  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
4. Troubleshooting  
4.1. Common Problems  
In most cases, nearly every issue with the MultiView CAT5 Video System can be  
resolved by checking the CAT5 termination and making sure that it’s pinned to the  
TIA/EIA 568B wiring specification. However, there may be other problems that  
cause the system to not perform as it’s designed. Below are solutions to the most  
common installation errors.  
Problem:  
Solution:  
No video signal at the transmitter local port or at the receiver.  
• Check that both units are powered.  
• Ensure EQ adjustment is set correctly — turn knob slowly.  
• Make sure the CAT5 cable is terminated correctly per the  
TIA/EIA 568B wiring specification.  
• Is the display device powered on and functioning?  
Check to ensure display settings (resolution, refresh rate, etc) are  
compatible with input signal.  
• The NEC 600 only supports RGBHV video modes. Component,  
composite or S-video is not supported. This is due to the design on  
the option card slot interface and not the NEC 600 receiver.  
Problem:  
Solution:  
Poor video quality:  
Have all receiver adjustments been finished (see section 3.3).  
• Ensure EQ adjustment is set correctly — turn knob slowly.  
• Check all cable connections.  
• The video signal’s refresh rate may be set too high. Reset to a  
lower refresh rate in your monitor-configuration menu.  
• There may be a delay skew issue. See Section on Skew.  
Problem:  
Solution:  
Poor audio quality:  
• Powered speakers are required. Make sure speaker power is  
ON.  
• Check input source levels from the source device. Make sure  
the audio source is not overdriven or underdriven.  
Problem:  
Solution:  
Serial communication doesn’t work correctly.  
• Are the serial devices connected properly? Are the serial  
parameters correct for source/destination devices?  
• SAP units have a default baud rate of 9600 bps and use 3 wire  
(TX,RX,GND) signals only.  
• Please refer to the SAP Communication Protocol user manual for  
information on using SAP series commands.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Problem:  
Solution:  
Green shift” or “green washout” on multimedia signals.  
The standard video/serial model is designed to function with DC  
coupled signals in which the black level is referenced to 0 volts.  
Nearly all VGA cards function this way.  
Some media servers, however, provide AC coupled signals and  
can cause a green color shift in the video. This is a result of the  
sync clamping on the red and blue channels of the video/serial  
model.  
For five-component (RGB/H&V) AC coupled video, the  
MultiView CAT5 XRTx Universal transmitter has been designed  
with full DC restoration capability. This problem is easily solved  
via a simple switch setting in the XRTx Transmitter. Please refer to  
the XRTx Transmitter user manual.  
Problem:  
Solution:  
Image has purple/blue tint  
Display gain may need adjustment. Older displays may have an  
incorrect gain adjustment setting. This requires using the remote to  
access the “expert mode” . Please contact NEC technical support or  
Magenta Research for assistance in this.  
Displays purchased after May 2009 should not require this.  
Problem:  
Solution:  
Notes on Daisy Chaining:  
When daisy chaining, the maximum cable distance is not increased  
beyond the rated distance of the receiver used. For example, an  
AK600 can only daisy chain within 600 ft of the transmitter.  
It is possible to daisy chain out of a short range receiver into a longer  
range receiver to increase the range. For example, over 600 ft an  
AK600 can be daisy chained into an AK1200 which allows for daisy  
chaining to 1,200 ft.  
When using NEC600 SAP units, a maximum of 10 units may be  
daisy chained within the rated cable length of the receiver if  
using standard CAT5/6 or a maximum of 7 units may be daisy  
chained within the rated cable length of the receiver if using  
skew-free cable.  
Note that if SA/SAP units are used for video only and the SA/  
SAP option is not in use, then you may daisy chain to 12 units.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
Appendix A. Cabling Pinouts  
Table A-1. T568B CAT5 pinout  
NOTE: The external DB9 connector is intended for console access to the receiver and  
does not support external SAP RS232 protocol. This connection should not be used to  
control the display.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX B: Setting Sync modes.  
Appendix B. Setting Sync Mode  
The NEC 600 has the capability for fixed and agile sync. The default sync mode setting  
is for agile sync which replicates the source sync polarity signals. However some  
displays require a fixed sync polarity that is not possible to change at the video source.  
1080P signals may also require this mode if the sync is a very narrow pulse.  
The following details how to change the sync polarity of the horizontal and vertical sync  
signal. This is only valid if sync mode is set to FIXED (Note that the transmitter must  
also be set to the same sync mode—see transmitter user manual. Not all  
transmitters support this feature).  
To enter Sync Configuration mode, press and hold the EQ/Skew knob for 5  
seconds until the Mode LED turns solid white (not flashing).  
The Range LEDS (1-4) will indicate which parameter is selected and its  
current value. To change a value, turn the knob. To select the next  
parameter, press the knob. To exit , press knob until Mode LED turns green  
or wait 10 seconds.  
LED 1: Dim green = Agile Sync (default)  
Bright Green = Fixed Sync  
LED 2: Dim Green = Negative Horizontal sync polarity  
Bright Green = Positive Horizontal sync polarity  
LED 3: Dim Green = Negative Vertical sync polarity  
Bright Green = Positive Vertical sync polarity  
In normal operation, the Range LED’s also indicate which sync mode is in use:  
LED1: Off indicates Agile, non-fixed sync mode (default)  
On indicates Fixed sync mode in use.  
LED2: On indicates Positive Horizontal sync polarity if fixed sync is enabled.  
Off indicates Negative Horizontal sync polarity if fixed sync is enabled.  
LED3: On indicates Positive Vertical sync polarity if fixed sync is enabled.  
Off indicates Negative Vertical sync polarity if fixed sync is enabled.  
NOTE: When in Sync Configuration mode, pressing the knob past LED3 will  
result in all LED’s being off. This is a special video voltage offset mode that is  
currently not implemented. It is important that the knob not be turned when in  
this mode as you could change the video voltage level and affect picture quality.  
If this does happen, please turn the knob fully counterclockwise to restore the  
video voltage level to its default state.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAGENTA MULTIVIEW™ SERIES  
Dec Hex  
00 00  
01 01  
02 02  
03 03  
04 04  
05 05  
06 06  
07 07  
08 08  
09 09  
10 0A  
11 0B  
12 0C  
13 0D  
14 0E  
15 0F  
16 10  
17 11  
18 12  
19 13  
20 14  
21 15  
22 16  
23 17  
24 18  
25 19  
26 1A  
27 1B  
28 1C  
29 1D  
30 1E  
31 1F  
32 20  
33 21  
34 22  
35 23  
36 24  
37 25  
38 26  
39 27  
40 28  
41 29  
42 2A  
43 2B  
44 2C  
45 2D  
46 2E  
47 2F  
48 30  
49 31  
50 32  
51 33  
52 34  
53 35  
54 36  
55 37  
56 38  
57 39  
58 3A  
59 3B  
60 3C  
61 3D  
62 3E  
63 3F  
Dec Hex  
64 40  
65 41  
66 42  
67 43  
68 44  
69 45  
70 46  
71 47  
72 48  
73 49  
74 4A  
75 4B  
76 4C  
77 4D  
78 4E  
79 4F  
80 50  
81 51  
82 52  
83 53  
84 54  
85 55  
86 56  
87 57  
88 58  
89 59  
90 5A  
91 5B  
92 5C  
93 5D  
94 5E  
95 5F  
96 60  
97 61  
98 62  
99 63  
100 64  
101 65  
102 66  
103 67  
104 68  
105 69  
106 6A  
107 6B  
108 6C  
109 6D  
110 6E  
111 6F  
112 70  
113 71  
114 72  
115 73  
116 74  
117 75  
118 76  
119 77  
120 78  
121 79  
122 7A  
123 7B  
124 7C  
125 7D  
126 7E  
127 7F  
Dec Hex  
128 80  
129 81  
130 82  
131 83  
132 84  
133 85  
134 86  
135 87  
136 88  
137 89  
138 8A  
139 8B  
140 8C  
141 8D  
142 8E  
143 8F  
144 90  
145 91  
146 92  
147 93  
148 94  
149 95  
150 96  
151 97  
152 98  
153 99  
154 9A  
155 9B  
156 9C  
157 9D  
158 9E  
159 9F  
160 A0  
161 A1  
162 A2  
163 A3  
164 A4  
165 A5  
166 A6  
167 A7  
168 A8  
169 A9  
170 AA  
171 AB  
172 AC  
173 AD  
174 AE  
175 AF  
176 B0  
177 B1  
178 B2  
179 B3  
180 B4  
181 B5  
182 B6  
183 B7  
184 B8  
185 B9  
186 BA  
187 BB  
188 BC  
189 BD  
190 BE  
191 BF  
Dec Hex  
192 C0  
193 C1  
194 C2  
195 C3  
196 C4  
197 C5  
198 C6  
199 C7  
200 C8  
201 C9  
202 CA  
203 CB  
204 CC  
205 CD  
206 CE  
207 CF  
208 D0  
209 D1  
210 D2  
211 D3  
212 D4  
213 D5  
214 D6  
215 D7  
216 D8  
217 D9  
218 DA  
219 DB  
220 DC  
221 DD  
222 DE  
223 DF  
224 E0  
225 E1  
226 E2  
227 E3  
228 E4  
229 E5  
230 E6  
231 E7  
232 E8  
233 E9  
234 EA  
235 EB  
236 EC  
237 ED  
238 EE  
239 EF  
240 F0  
241 F1  
242 F2  
243 F3  
244 F4  
245 F5  
246 F6  
247 F7  
248 F8  
249 F9  
250 FA  
251 FB  
252 FC  
253 FD  
254 FE  
255 FF  
Appendix C. SAP  
Addressing  
To set the NEC600 SAP address, use  
the two rotary address knobs on the  
unit. You will need to convert the  
decimal address desired to a  
hexadecimal address using the table to  
the right.  
The left knob designated H is the most  
significant digit, while the right side  
designated L is the least significant  
digit.  
For example, to set a decimal address  
of 90, the knobs should be set to H=5  
and L=A, for a hexadecimal number of  
5A.  
Please refer to the SAP  
Communication Protocol User Guide  
for information on usage of the SAP  
series commands.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Appendix D. Rotary Knob Menu  
The following diagram details the various configuration settings available through the  
rotary knob. This is provided to graphically show each menu choice.  
Mode LED:  
Solid Green  
Range LEDs:  
config status  
Press knob  
> 0.5sec  
(< 5sec)  
Press knob  
> 5sec  
Normal Operation  
Mode LED  
Flashing White  
Mode LED  
Solid White  
Range LED1:  
Sync-mode  
Status  
Configure  
Sync-mode:  
Agile/fixed  
Video EQ  
Adjustement Mode  
Range LEDs:  
EQ setting  
Press knob  
> 0.5sec  
Press knob  
> 0.5sec  
Press knob  
> 0.5sec,  
or 10sec  
timeout  
from any  
menu  
Mode LED  
Flashing Red  
Mode LED  
Solid White  
Range LED2:  
HSync-polarity  
Status  
Configure  
HSync-polarity:  
+/-  
Red-skew  
Adjustement Mode  
Range LEDs:  
skew setting  
Press knob  
> 0.5sec  
Press knob  
> 0.5sec  
Mode LED  
Flashing Green  
Mode LED  
Solid White  
Range LED3:  
VSync-polarity  
Status  
Configure  
VSync-polarity:  
+/-  
Green-skew  
Adjustement Mode  
Range LEDs:  
skew setting  
Press knob  
> 0.5sec  
Press knob  
> 0.5sec  
Mode LED  
Mode LED  
Blue-skew  
Adjustement Mode  
Adjust: video-offset  
voltage.  
Flashing Blue  
Solid White  
Range LEDs:  
Range LEDs:  
skew setting  
Video offset  
voltage setting  
Note: Video-offset voltage  
adjustment is for future use.  
Always set to "0".  
Range LED  
Status Display  
Dim: Config option = 0 (off, or de-selected)  
Bright: Config Option = 1 (on, or selected)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magenta Research  
128 Litchfield Road, New Milford, CT 06776 USA  
(860) 210-0546 FAX (860) 210-1758  
PN 5310229-01, Rev 01, Jul-2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Pavoni Coffeemaker P03 User Manual
Lennox Hearth Indoor Fireplace ULC S610 User Manual
Lexmark Indoor Fireplace MONTEST User Manual
Life Fitness Elliptical Trainer CT9500 User Manual
Lincoln Electric Welding System SVM172 A User Manual
Maytag Refrigerator ARB1905CW User Manual
Melissa Vacuum Cleaner 240 013 User Manual
Memorex MP3 Player MKS2114 User Manual
Meridian America Speaker System G68 User Manual
Metrologic Instruments Barcode Reader MS1890 User Manual