MABIS Duro Med Blood Pressure Monitor Semi Automatic Blood Pressure Monitor User Manual |
INSTRUCTION MANUAL
Semi-Automatic
Blood Pressure Monitor
with Memory
04-263-001 (Adult size cuff)
04-263-006 (Large adult size cuff)
Please read this instruction manual
completely before operating this unit.
TM
Taking care of your health care needs
English • French • Portuguese • Spanish
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Product Identification & Caution . . . . . . . . . . . . . . . . . .4
General Blood Pressure Information . . . . . . . . . . . . . . .5
Important Information Before Use . . . . . . . . . . . . . . . . .7
Battery Installation/Replacement . . . . . . . . . . . . . . . . . .8
Applying Your Blood Pressure Cuff . . . . . . . . . . . . . . . .9
Taking Your Blood Pressure Reading . . . . . . . . . . . . . .10
Recalling Measurements in Memory . . . . . . . . . . . . . .11
Description of Display Symbols . . . . . . . . . . . . . . . . . .12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . .13
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . .13
Sample Blood Pressure Log . . . . . . . . . . . . . . . . . . . .14
Introduction
To achieve the maximum benefit from your blood pressure monitor, we recommend that you
first consult with your physician or trained healthcare professional.
Thank you for purchasing a MABIS Digital Blood Pressure Monitor. With proper care and use,
your monitor will provide you with many years of reliable readings.
The method of measurement that your Monitor uses is called the oscillometric method. The
monitor detects your blood’s movement through the artery in your arm and converts the move-
ments into a digital reading. The oscillometric method does not require a stethoscope, making
the monitor easy to use.
Blood pressure readings determined with this device are equivalent to measurements
obtained by a trained observer using the cuff/stethoscope auscultation method, within the
limits prescribed by the American National Standard for Electronic or Automated
Sphygmomanometers.
– 3 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Identification & Caution
LCD Display
Memory Recall Button
Cuff Tubing
Arm Cuff
Power Button
ON/OFF
Battery Compartment
Tubing Connector
4 x AA (LR06 size,
1.5V Batteries
Inflation Bulb
Air Release Valve
Caution:
You can stop the inflation or deflation process anytime by pressing the POWER button.
– 4 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Why Monitor Your Blood Pressure at Home?
Many people experience “White Coat Syndrome”, which is a temporary elevation of blood
pressure during a visit at their physician’s office. Although only temporary, it can cause blood
pressure to rise and give a false indication of a person’s true blood pressure.
Whether or not you experience “White Coat Syndrome”, home blood pressure monitoring
provides:
1) The opportunity to supplement your physician’s office measurements.
2) An accurate indication of any change.
3) A record to assist your physician in evaluating your health and making important
decisions.
4) Consistent, daily measurements of your blood pressure.
Note: Variations in your individual readings should only be interpreted by your physician or
trained healthcare professional.
General Blood Pressure Information
What is Blood Pressure?
Blood pressure is the pressure that is exerted by blood flowing against the walls of the blood
vessels throughout your body.
Your heart, which is the center of the circulatory system, provides the force for the blood to flow
or circulate. When your heart contracts or beats, the blood is forced through the blood vessels
increasing the pressure. This is the highest pressure in the cycle or what is referred to as
SYSTOLIC blood pressure. In between beats, your heart relaxes and your blood pressure
decreases. This is referred to as DIASTOLIC blood pressure.
This complete series of events, which occurs in a single heartbeat, is known as the CARDIAC
CYCLE.
Your MABIS Monitor will automatically read your blood pressure and display both systolic and
diastolic readings on the screen.Your systolic will be positioned as the upper number and the
diastolic reading will be the lower number.
(systolic)
120/80
(diastolic)
– 5 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Blood pressure is measured in millimeters (mm) of mercury (Hg) and is generally recorded
with the systolic pressure (120) listed first and the diastolic pressure (80) listed second. The
numbers are typically separated by a slash mark (/) as shown.
Both pressure readings, the SYSTOLIC and DIASTOLIC, are necessary for a physician to
evaluate the status of a patient’s blood pressure.
Please contact your physician for specific information regarding your own blood pressure.
What Influences Blood Pressure?
Many factors such as genetics, age, sex, altitude, physical activity, anxiety, muscular devel-
opment, certain medications or even the time of day can influence blood pressure.
Influences such as sleep or relaxation decrease blood pressure, while anxiety or exercise
increase blood pressure.
WHO Blood Pressure Classifications
Standards for assessment of high or low blood pressure have been established by the
World Health Organization (WHO) as shown on the following chart:
CATEGORY
SYSTOLIC
(mmHg)
DIASTOLIC
(mmHg)
Optimal
Normal
<120
<130
<80
<85
High – Normal
130-139
85-89
Mild Hypertension
Borderline
140-159
140-149
160-179
≥180
90-99
90-94
Moderate Hypertension
Severe Hypertension
100-109
≥110
Isolated Systolic Hypertension
Borderline
≥140
140-149
<90
<90
This chart is only a general guideline. Contact your physician or trained healthcare
professional to determine your NORMAL blood pressure.
– 6 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Variations in Blood Pressure
Blood pressure is influenced by many factors and can change from moment to moment.
Normally, blood pressure is lowest during sleeping periods and rises during the day. The
graph below represents variations in blood pressure shown over a day with measurements
taken every 5 minutes.
The dotted line represents the sleep
period. The rise in blood pressure at
1 pm (A in the graph) corresponds to
a stressful occurrence and at 7 pm (B
in the graph) a period of exercise.
Important Information Before Use
1. Blood pressure readings should be interpreted by a physician or trained healthcare pro-
fessional, who is familiar with your medical history.
2. Perform your measurement in a quiet place. You should be seated and relaxed.
3. Avoid smoking, eating, taking medication, alcohol consumption or physical activity 30
minutes prior to taking a reading. If you are exhibiting signs of stress, avoid taking your
measurement until the feeling subsides.
4. Rest 15 minutes prior to taking a reading.
5. Remove any constrictive clothing or jewelry that may interfere with the cuff placement.
6. Keep the monitor stable during measurements. Remain still; do not talk during
measurements.
7. Record your daily readings on a chart.
8. Take your readings at the same time, each day (or as recommended by your physician).
9. Wait a minimum of 15 minutes between readings. The wait time may vary depending on
individual physiological characteristics.
10. This device is intended for adult use.
11. The inflation or deflation process can be stopped by pressing the POWER button.
– 7 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery Installation/Replacement
1) Press down and lift the cover in the direc-
tion of the arrows as shown.
2) Insert or replace 4 “AA” batteries into the
compartment, matching the indicated
polarity symbols.
3) To close, match up and connect the
bottom hooks of the cover, then push
the top end.
Note: Replace the batteries when the Low
Battery symbol appears on the display or
when the display remains blank when the
POWER button is pressed.
4) It is recommended to remove the batteries
if the unit will not be used for an extended
period of time.
– 8 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Applying Your Blood Pressure Cuff
Avoid smoking, eating, taking medication, alcohol consumption or physical activity 30 min-
utes prior to taking a reading. If you are exhibiting signs of stress, avoid taking your meas-
urement until the feeling subsides. Rest 15 minutes prior to taking a reading.
Note: If for any reason you are unable to or should not use
your left arm, please modify the following instructions and
apply the cuff to your right arm. Your physician can tell you
which arm is best for you to use.
1. Remove any constrictive clothing or jewelry that may
interfere with the cuff placement. Be seated with your
feet flat on the floor.
m
ch
n
c
i
3
~
.
2
2
~1
.8
0
O
K
IND
EX
m
6
ch
c
n
i
2
3
~
2
2
~12.
.7
8
Fig. 1
2. Insert the end of the connector into the monitor, Fig. 1.
3. Widen or open the cuff by pulling or rolling the
bottom of the cuff towards the right,
Fig. 2. This should open the cuff,
creating a cylinder. Do not extend
the cuff beyond the metal bar.
4. Insert your arm into the cuff
(cylinder). Position the (
Fig. 2
)
mark over the main artery (on
the inside of your arm). Fig. 3.
Fig. 3
5. The bottom edge of the cuff should be positioned
approximately
1”
one inch ABOVE the elbow joint. Fig. 4.
6. Reaching underneath your left arm with your right hand,
pull the end of the cuff towards your body to tighten the
cuff, Fig. 5. Wrap and secure the cuff making sure that
the ( ) mark remains as shown, Fig. 3.
Fig. 4
7. The cuff should fit comfortably, yet snugly around your arm.
You should be able to insert two fingers between your arm
and the cuff.
Note: The cuff size is suitable for use when the vertical “Index”
mark is within the horizontal “OK” range. A different sized cuff is
needed if the “Index” mark is outside of the “OK” range.
Fig. 5
– 9 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Taking Your Blood Pressure Reading
Proceed only after reading the previous sections of this manual.
Remember! Remain still; do not talk during the measurement.
1. Rest your elbow on a solid surface with your palm facing
upward. Elevate your arm so that the cuff is at the same level
as your heart, Fig. 1. Your wrist should be level with your collar-
bone. Relax your left hand.
2. Press the POWER button. The
unit will run a self-test, Fig. 2.
Fig. 1
3. If a downward arrow ( ) flash-
es, there is air remaining in the
cuff. Release the air by pressing
the “Air Release Valve” until “0”
appears on the display, Fig 3.
Fig. 2
4. Using your right hand, squeeze
and release the inflation bulb at a steady pace. The inflation
pressure must be 50-60 mmHg above your normal systolic
pressure. If the pressure in the cuff is insufficient, an upward
arrow ( ) will flash. Continue to steadily inflate the cuff to the
proper level.
Fig. 3
5. Upon achieving the proper inflation level, release the pressure
on the bulb.
6. The pressure in the cuff will automatically begin to decrease.
The display will represent the deflation, Fig. 4.
7. Upon completion, your blood pressure (systolic and diastolic)
measurement will display, Fig. 5, with the downward arrow (
flashing.
)
8. Press the “Air Release Valve” until the cuff pressure is released
and the downward arrow ( ) disappears, Fig. 6.
Fig. 4
9. Your reading will be automatically stored in memory.
10. To conserve energy, press the POWER button to turn the power
off. Otherwise, the unit will automatically shut of after approxi-
mately 1 minute.
11.Disconnect the cuff tubing from the monitor prior to storing.
Fig. 6
– 10 –
Fig. 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Recalling Measurements in Memory
You can recall up to 60 measurements in memory to share with your physician or trained
healthcare professional.
1. Press the MEMORY button. The last
stored measurement will display.
2. Continue to press MEMORY to
view the next previously stored
measurement.
Note: The memory bank can store up to 60
readings. When the number of readings
exceeds 60, the oldest data will be replaced
with the new record.
All stored measurements will be erased by
removing any one of the batteries for approx-
imately 2 minutes.
– 11 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Description of Display Symbols
Display:
Icons:
Appears when measurement value is
stored in memory or is recalled from
memory
Systolic Pressure
Diastolic Pressure
Pulse Rate
Appears when batteries should be
replaced
Shows the pulse rate per minute
Occurs when a mistake was made
during measurement
Appears when manual cuff deflation is
needed.
No. of Memory
Sequence
Appears when manual cuff inflation is
needed.
Troubleshooting
If any abnormality occurs during use, please check and correct the following:
Condition
Correction
Display is blank when power is on.
Check and correct the polarity of the
installed batteries. Reinstall or replace
batteries.
Measurement incomplete or
abnormally low or high values
displayed.
Review and follow “Applying Your
Blood Pressure Cuff” and “Taking
Your Blood Pressure Reading” sections.
Replace the batteries.
EE symbol displays.
Did you talk or move during the
measurement? Review “Applying Your
Blood Pressure Cuff” section.
Measurements are different from
those typically measured by
physician or every measurement
reading is different.
Remember, blood pressure readings
are influenced by physical and mental
conditions and/or even the time of day.
Daily measurements should be
interpreted by your physician.
– 12 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and Maintenance
1. Disconnect the cuff tubing from the monitor prior to storing.
2. Only use a soft, dry cloth to clean your blood pressure monitor.
3. Avoid using any types of liquids on the monitor or cuff.
4. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
5. Avoid extreme temperatures.
6. Never disassemble the monitor or cuff.
7. Dropping or subjecting your blood pressure monitor to strong shocks should be avoided.
Product Specifications
Name and model number
Semi-Automatic Digital Blood Pressure Monitor
with Memory, 04-263-001, 04-263-006
Display system
Measuring method
Power source
Digital display/LCD
Oscillometric
4 “AA” batteries
Measuring range
Pressure: 20-280 mmHg
Pulse: 40-180 beats/minute
Accuracy
Pressure: ± 3 mmHg
Pulse: ±5% of reading
Inflation
Deflation
Memory
Manual Inflation
Automatic Pressure Release Valve
Built-in memory enabling display of up to 60 measurements
Automatic Power Off
Approximately 1 minute after last button operation
Temperature 50oF - 104oF (10oC - 40oC)
Humidity 40 - 85%
Operation Environment
Storage Environment
Temperature 23oF - 140oF (-5oC - 60oC)
Humidity 10 - 95%
Monitor Dimensions
Weight
5-1/2” x 4-1/2” x 2-1/4”
11.82 oz. (without batteries)
Arm Circumference Range
Adult size fits arm circumference: 8-5/8” - 12-5/8” (22-32 cm)
Large adult size fits arm circumference: 12-5/8” -16-1/2” (32-42 cm)
Accessories
Cuff, detailed guidebook, four “AA” batteries
Adult size cuff, Large adult size cuff
Options (sold separately)
Specifications are subject to change without notice
#91-032-263 02/02
– 13 –
©2002 MABIS Healthcare Inc.Www.Somanuals.com. All Manuals Search And Download.