Lopi Indoor Fireplace Freedom Bay Fireplace Insert User Manual

Freedom Bay Fireplace Insert  
Owner's  
Manual  
Masonry Fireplace  
Insert  
Save these instructions  
for future reference  
SAFETY NOTICE:  
If this appliance is not properly installed, a house fire may  
result. For your safety, follow the installation directions.  
Contact local building or fire officials about restrictions and  
installation inspection requirements in your area.  
Copyright 2007, Travis  
Industries, Inc.  
Listed  
$10.00  
100-01163  
4050922  
Tested to: U.L. 1482  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
3
Maintaining Your Appliance  
General Information  
Daily Maintenance (while stove is in use) ................21  
Remove Ash (if necessary)..............................21  
Clean the Glass (if necessary) .........................21  
Introduction ......................................................2  
Important Information .........................................2  
Safety Precautions.............................................4  
Features & Specifications....................................6  
Monthly Maintenance (while appliance is in use).......22  
Door and Glass Inspection ..............................22  
Creosote - Formation and Need for Removal ......2  
Fireplace Insert Installation  
Planning The Installation .....................................7  
Preparation for Installation ..............................7  
Additional Accessories Needed for Installation ....7  
Installation Considerations ..............................7  
Yearly Maintenance............................................23  
Touch Up Paint.............................................23  
Cleaning the Air Duct and Blower .....................23  
Firebrick and Baffle Inspection .........................23  
Fireplace Requirements ......................................8  
Insert Placement Requirements............................9  
Hearth Requirements .........................................9  
Masonry Fireplace Requirements..........................9  
Drafting Performance .........................................10  
Leveling Bolt Installation......................................10  
Blower Installation..............................................10  
Block-Off Plate Installation...................................11  
Insert with Positive Connection.............................12  
Insert with Direct Connection ...............................12  
Insert with Face Seal Connection.....................13  
Door Parts........................................................24  
Replacing the Glass.......................................24  
Replacing the Door Gasket..............................24  
Replacing the Door Handle..............................24  
Firebox Parts ....................................................25  
Floor and Side Firebrick..................................25  
Baffle Removal & Replacement.............................26  
Air Tube Removal & Replacement.........................26  
Warranty  
Warranty ..........................................................27  
Operating Your Appliance  
Listing Information  
Safety Notice: ...................................................14  
Before Your First Fire .........................................14  
Opening the Door ..............................................14  
Bypass Operation ..............................................15  
Starting a Fire ...................................................15  
Adjusting the Burn Rate ......................................17  
Ash Removal ....................................................17  
Blower Operation...............................................18  
Re-Loading the Stove.........................................18  
Overnight Burn..................................................18  
Normal Operating Sounds ...................................18  
Hints for Burning................................................19  
Selecting Wood.................................................19  
Troubleshooting ................................................20  
Listing Label .....................................................28  
Optional Equipment  
Door Shell Installation .........................................29  
Surround Panels ...............................................31  
Index  
Index...............................................................32  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Safety Precautions  
The viewing door must be  
closed and latched during  
operation.  
Gasoline or other flammable  
liquids must never be used to  
start the fire or "Freshen Up" the  
fire. Do not store or use  
gasoline or other flammable  
liquids in the vicinity of this  
appliance.  
Never block free airflow through  
the air vents on this appliance.  
This appliance is designed and  
approved for the burning of cord  
wood only. Do not attempt to  
burn any other type of fuel other  
than cord wood in this  
Ashes must be disposed in a  
metal container with a tight lid  
and placed on a non-  
combustible surface well away  
from the home or structure.  
ASHES  
appliance, it will void all  
warranties and safety listings.  
Do not touch the appliance while  
it is hot and educate all children  
of the danger of a high-  
temperature appliance. Young  
children should be supervised  
when they are in the same room  
as the appliance.  
Keep furniture, drapes, curtains,  
wood, paper, and other  
combustibles a minimum of 36"  
away from the front of the  
appliance.  
36"  
This appliance must be properly  
installed to prevent the  
possibility of a house fire. The  
instructions must be strictly  
adhered to. Do not use  
makeshift methods or  
compromise in the installation.  
Contact your local building  
officials to obtain a permit and  
information on any installation  
restrictions or inspection  
requirements in your area.  
Notify your insurance company  
of this appliance as well.  
Ok  
Inspect the chimney connector  
and chimney at least twice  
monthly and clean if necessary.  
Creosote may build up and  
cause a house fire.  
This appliance must be  
connected to a listed high  
temperature (UL 103 HT)  
residential type chimney or an  
approved masonry chimney with  
a standard clay tile, or stainless  
steel liner.  
Type  
HT  
Clay  
Liner  
Do not connect this appliance to  
any chimney serving another  
appliance.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
5
When installed in a mobile  
home, this appliance must be  
bolted to the floor, have outside  
air, and not be installed in the  
bedroom (Per H.U.D.  
requirements). Check with local  
building officials.  
Do not place clothing or other  
flammable items on or near this  
appliance.  
Mobile  
Home  
Never try to repair or replace  
any part of this appliance unless  
instructions are given in this  
manual. All other work must be  
done by a trained technician.  
Do not make any changes or  
modifications to an existing  
masonry fireplace or chimney to  
install this appliance.  
Do not make any changes to the  
appliance to increase  
combustion air.  
Allow the appliance to cool  
before carrying out any  
maintenance or cleaning.  
Overfiring the appliance may  
cause a house fire. If a unit or  
chimney connector glows, you  
are overfiring.  
Maintain the door and glass seal  
and keep them in good  
condition.  
Do not use a grate or other  
device to elevate the fire off of  
the firebox floor. Burn the fire  
directly on the bricks.  
Avoid placing wood against the  
glass when loading. Do not  
slam the door or strike the glass.  
Do not throw this manual away.  
This manual has important  
operating and maintenance  
instructions that you will need at  
a later time. Always follow the  
instructions in this manual.  
Travis Industries, Inc. grants  
no warranty, implied or  
stated, for the installation or  
maintenance of your  
appliance, and assumes no  
responsibility of any  
consequential damage(s).  
This  
Manual  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Features & Specifications  
Installation Options:  
Features:  
Masonry Fireplace Insert  
EPA Phase II Approved  
3.1 Cubic Foot Firebox Volume  
Single Operating Control  
Accepts Logs Up to 24" Long  
Steel Plate Construction (5/16" & 3/16")  
Heavy Duty Refractory Firebrick  
High-Tech Blower  
WARNING: Do not install this fireplace insert into a  
factory-built metal (Z.C.) fireplace.  
Heating Specifications:  
Approximate Maximum Heating Capacity (in square feet)*  
Maximum BTU's per Hour (Cord Wood Calculation)  
Overall Efficiency (Oregon Method)  
1,200 to 2,250  
74,300  
70 %  
Maximum Burn Time  
Up to 12 Hours  
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside  
temperature. It is also affected by the quality and moisture level of the fuel.  
Dimensions:  
Measure side clearances  
6" Diameter Flue  
from the side of the insert.  
29-1/4"  
5-5/8"  
Weight = 470 Lbs.  
20-1/4"  
Measure top  
clearances from  
the top plate.  
21-3/4"  
Electrical Line (may  
be attached to the  
opposite side)  
15-3/4"  
43-3/4"  
4-3/4"  
Measure front clearances  
Fireplace Opening  
from the faceplate.  
Faceplate  
Figure 1  
Emissions:  
2.6 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (for qualified installers only)  
7
SAFETY NOTICE:  
Please read this entire manual before you install and use your new room heater. Failure  
to follow instructions may result in property damage, bodily injury, or even death.  
Contact local building orfire officials about restrictions and installation inspection  
requirements in yourarea.  
Planning The Installation  
We suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you  
install the fireplace insert yourself, your authorized dealer should review your installation plans.  
Check with local building officials for any permits required for installation of this fireplace insert and  
notify your insurance company before proceeding with installation.  
Preparation for Installation  
Check for damage to the exterior of the fireplace insert (dents should be reported, scratches can be  
fixed by applying touch up paint).  
Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).  
The fireplace insert can be lightened by removing the firebricks and baffle (pg 25) - replace before  
operation.  
Additional Accessories Needed for Installation  
1
2
Door Shell Kit (Black 99300175 Brass 99300176 or Pewter 99300177 - see pg 29)  
Surround Panels (see page 31)  
Installation Considerations  
Considerations  
Installation Type  
• Provides best draft  
• Easiest to clean  
Insert with Positive Flue (Full Reline)  
(Page 12)  
• Provides good draft  
• Requires fireplace block-off plate - see page 10  
Insert with Direct Connect Flue  
(Page 12)  
• Utilizes existing masonry fireplaces with cross section  
of 28" to 144"  
• Provides marginal draft  
• Easiest to install  
• Requires the optional surround panels and insulation  
(see "Surround Panels" on page 31).  
Insert with Face Seal Connection  
(Page 13)  
NOTE: Before installing verify with local building  
officials that this type of installation is  
approved in your area.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Installation (for qualified installers only)  
Fireplace Requirements  
Figure 2 shows the minimum size requirements for the type of fireplace used.  
Minimum Fireplace Size  
C
ombustible  
a
b
c
d
e
f
Height (front)  
Height (rear)  
Width (front)  
Width (rear)  
Depth  
21-3/4"  
21-3/4"  
29-1/4"  
29-1/4"  
15-3/4"  
20-3/4"  
45-1/4"  
56-1/4"  
50-1/4"  
Mantel  
j
Non-Combustiblhe Facing  
i
Hearth Depth*  
Hearth Width  
Facing Width  
Facing Height  
g
h
i
b
a
d
with Mantel Shield 37-1/4"  
Mantel Height 52-1/4"  
with Mantel Shield 39-1/4"  
c
e
j
Non-Combustible Hearth  
g
* This is the distance the insert protrudes from  
the fireplace opening plus the required 16" of  
hearth extension.  
f
Figure 2  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (for qualified installers only)  
Insert Placement Requirements  
9
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,  
doors), 36" of the front of the insert  
Insert and hearth must be installed on a level, secure floor  
The minimum clearances, facing, and hearth requirements in Figure 3 must be met.  
Measure side clearances from  
the side of the insert.  
Minimum Clearances  
Combustibl  
k
l
Sidewall to Insert  
Side Facing  
15"  
13-1/2"  
30"  
17"  
32"  
19"  
16"  
8"  
e
Mantel  
Combustible Top Facing  
m
Top Facing  
n
Side  
Wall  
with mantel shield  
Mantel to Insert  
with mantel shield  
Hearth (Front)  
Hearth (Side)  
n
m
Facing  
o
p
q
k
l
Front of Insert  
36"  
p
Non-Combustible  
x
Extension onto Hearth  
4-3/4"  
Hearth  
q
x
o
Measure front clearances from  
the faceplate.  
Figure 3  
Hearth Requirements  
Must extend 16" in front of the insert and 8" on both sides  
Must be non-combustible and at least .018" thick (26 gauge)  
Masonry Fireplace Requirements  
Chimney must have a clay tile liner or a stainless steel liner (positive connection)  
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired  
prior to installation of the insert  
Chimney height: 15' minimum; 33' maximum.  
Entire fireplace, including chimney, must meet local building requirements  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Installation (for qualified installers only)  
Drafting Performance  
This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,  
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),  
may adversely affect draft. Travis Industries can not be responsible for external forces leading to less  
than optimal performance.  
Leveling Bolt Installation  
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise  
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust  
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune  
the leveling bolts to level the insert (see Figure 4).  
The leveling bolts go  
into the holes at the  
rear corners of the  
insert.  
This distance is the  
hearth step-up. The  
leveling bolts should  
stick out this far from the  
base of the insert.  
Fireplace  
Hearth  
Figure 4  
Blower Installation  
The included blower is fragile and should be installed last (see the directions below).  
Remove the two  
screws underneath the  
ashlip with a 3/8"  
nutdriver. Align the  
blower under the  
ashlip and replace the  
two screws to secure.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (for qualified installers only)  
Block-Off Plate Installation  
11  
Whenever this appliance is installed with a direct connection a block-off plate, or other non-combustible  
seal-off device (e.g. damper adapter), will need to be installed. This device is used to seal the chimney,  
insuring no smoke enters the home and providing the chimney system with a seal to promote draft. The  
directions below detail the steps for construction and installation of a block-off plate.  
1
2
Determine a location for the block-off plate at the top of the firebox below the damper area (make  
it high enough to allow installation of the connection pipe). The location should be level and in an  
area where it can be mounted easily. Measure the width at the rear ("A") and front ("B") of the  
firebox at the height where the block-off plate will be installed (see Figure 5). Then measure the  
depth of the location where the block-off plate will be installed ("C").  
Make a cardboard template of the measurements, but add a 2" flange to each side. This flange  
will be used to mount the block-off plate to the inside of the firebox. Bend the flanges downwards  
on the template and place it inside the fireplace. If the template fits correctly in its planned  
location, go to the next step. If it does not, make a new template with the appropriate corrections  
until it fits correctly.  
3
4
With the template in place, mark the location of the flue (see “Dimensions” on page 6). This  
location approximates the center of the flue when the insert is in place (a slight offset may occur  
based upon insert and block-off plate placement). Remove the template and cut a 6 1/4"  
diameter hole centered on this mark.  
Make the block-off plate of 24 gage or thicker steel to match the template. Drill two holes in each  
flange for mounting the plate.  
5
6
Mount the block-off plate using masonry screws.  
Insulate the block-off plate using high-temperature fiberglass insulation (Kaowool® or equivalent)  
and furnace cement (allow the cement to dry for at least 24 hours before burning).  
7
After placing the appliance and installing the pipe through the block-off plate, use high-  
temperature fiberglass insulation and furnace cement to seal any cracks between the pipe and  
block-off plate.  
Block-Off Plate Template  
2" Flanges  
Measurement  
"A"  
(for attaching  
the block-off  
plate)  
Damper  
Measurement  
"C"  
See the  
B
dimensions to  
determine the  
location of the  
center of the  
flue.  
C
A
Measurement "B"  
Firebox  
See the dimensions to determine the location of  
the center of the flue.  
Figure 5  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Installation (for qualified installers only)  
Install a non-combustible  
cover plate to prevent water  
from entering the chimney  
Insert with  
Positive  
Connection  
Cap (prevents water  
from entering)  
NOTE:  
Flue Liner  
The liner must be  
stainless steel  
Most factory-built  
chimney manufacturers  
make stainless steel  
chimney liners, either  
flexible or rigid. This  
provides a wide variety  
of installation options.  
Make sure to follow the  
manufacturer's  
connector or flexible  
vent. Follow the liner  
manufacturer's  
insturctions for  
installation and  
support.  
Combustible Mantle  
Surround Panels  
Airtight Insulated  
Clean-Out  
instructions for  
installation and  
support.  
Remove damper  
or wire it open  
See the section "Insert  
Placement Requirements" for  
minimum clearances and  
hearth required.  
Figure 6  
Insert with Direct  
Connection  
Flue  
Liner  
NOTE:  
Stainless steel  
Direct connections  
require installation of  
an airtight block-off  
plate or damper  
adapter (see "Block-off  
Plate Installation" on  
page 11).  
chimney connector  
must Extend 1' past  
the block-off plate or  
to the flue liner  
Combustible Mantle  
Surround Panels  
Airtight  
Insulated  
Clean-Out  
Remove  
damper  
or wire it  
open  
See the section  
"Insert Placement  
Requirements" for  
minimum clearances  
and hearth required.  
Block-off plate or  
damper adapter  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (for qualified installers only)  
13  
Insert with Face  
Seal Connection  
NOTE:  
NOTE: It is  
Face seal connections  
require installation of the  
surround panels and  
insulation (see the  
"Surround Panel  
Installation" on page  
31).  
recommended your  
chimney have a  
minimum 28 and a  
maximum of 144  
square inch cross-  
sectional area to use a  
face seal connection,  
otherwise your  
Flue  
Liner  
Combustible Mantle  
chimney maynot have  
sufficient draw for the  
fireplace insert to  
operate correctly.  
Surround Panels  
with insulation  
Airtight Insulated  
Clean-Out  
See the section "Insert  
Placement Requirements"  
for minimum clearances  
and hearth required.  
Remove damper  
or wire it open  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Operating Your Appliance  
Safety Notice:  
If this appliance is not properly installed, a house fire may result. For your safety, follow the installation  
directions. Contact local building or fire officials about restrictions and installation inspection  
requirements in your area.  
Read and follow all of the warnings on pages 4 and 5 of this manual.  
Before Your First Fire  
Verify the Installation  
Before starting the stove, verify that it is properly installed and all of the requirements in this manual have  
been followed.  
Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.).  
Curing the Paint  
2 to 4 hours  
This heater uses a heat-activated paint that will emit some fumes while  
starting the first fire. Open doors and windows to the room to vent these  
fumes. This typically lasts two to four hours. You may also notice oil burning  
off of the interior of the heater. This rust-stopping agent will soon dissipate.  
Door Gasket - The door gasket might adhere to the paint on the front of the  
heater. Leave the door slightly ajar for the first fire and be careful when  
opening the door after the first fire.  
Over-Firing the Stove  
This stove was designed to operate at a high temperature. But due to differences in vent configuration,  
fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area  
starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to  
cool before proceeding.  
Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we  
suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top -  
temperatures exceeding 800° are generally considered over-firing and will void the warranty.  
Opening the Door  
Rotate  
Swing  
the door  
open.  
the door  
handle.  
The door becomes hot during use. Use a glove to open the door if the handle is hot.  
To prevent smoke from entering the room, open the bypass before opening the door (see following page  
for directions). You can also open the door a small amount and let air enter the firebox.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Your Appliance  
15  
Bypass Operation  
The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the  
flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary  
combustion and making the heater more efficient.  
When starting or re-loading, pull the bypass out.  
During normal operation, push the bypass in.  
Bypass Pulled Out  
Used for starting and re-loading  
Use the included pull tool  
to operate the bypass rod  
Bypass Pushed In  
Used for normal operation  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Operating Your Appliance  
Starting a Fire  
Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee",  
some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire  
starting.  
Make sure the air control is pushed in and the by-pass pulled out. If additional air is needed, open the  
doors 1/4" during the first five minutes of start-up.  
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start  
or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use.  
If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's  
instructions carefully.  
If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the  
firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage").  
Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning  
rapidly, place a few larger pieces of wood onto the fire.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Your Appliance  
17  
Adjusting the Burn Rate  
Use the air control slider to control the burn rate of the stove. See the illustration below for details.  
Use the air control to  
change the burn rate.  
Low Burn  
High Burn  
(air control closed)  
(air control open)  
Approximate Air Control Settings:  
Overnight Burn  
Medium Burn  
Medium High Burn  
High Burn  
Fully out to 9/32" open  
9/32" to 5/16" open  
5/16" to 7/16" open  
7/16" open to fully pushed in  
The air control becomes hot during operation - use gloves or a tool to prevent burns.  
The air control may take several minutes to influence the burn rate. When making adjustments, you  
may wish to let the stove burn for 10 minutes to gauge performance.  
Ash Removal  
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes  
should be placed on a noncombustible floor or on the ground, away from all combustible  
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally  
dispersed, they should be retained in the closed container until all cinders have thoroughly  
cooled.  
ASHES  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Operating Your Appliance  
Blower Operation  
The blower will turn  
on once the stove is  
up to temperature.  
This is typically 15 to  
30 minutes after  
OFF  
HIGH  
LOW  
Turn the dial all  
the way counter-  
clockwise until it  
clicks off.  
The high position  
is all the way  
Turn the dial  
all the way  
counter-clockwise, clockwise.  
without clicking  
starting the fire.  
off.  
Follow the directions  
below to alter the  
blower speed.  
The blower may be used to affect heat output (i.e.: to reduce heat output, turn the blower down).  
Route the power cord in a location where it will not come in contact with the appliance or become hot.  
Re-Loading the Stove  
Follow the directions below to minimize smoke spillage while re-loading the stove.  
1
2
3
Open the air control all the way (push it in). Open the bypass (pull it out).  
Open the door slightly. Let the airflow inside the firebox to stabilize before opening the doors fully.  
Load wood onto the fire.  
Overnight Burn  
This stove is large enough to accommodate burn times up to eight hours. Follow the steps below to  
achieve an overnight burn.  
1
2
3
4
Move the air control to high burn and let the stove become hot (burn for approximately 15 minutes).  
Load as much wood as possible. Use large pieces if possible.  
Let the stove burn on high for 15 minutes to keep the stove hot, then turn the air control to low.  
In the morning the stove should still be hot, with embers in the coal bed. Stir the coals and load  
small pieces of wood to re-ignite the fire, if desired.  
Differences if chimney height and draft may lower overall burn times.  
Normal Operating Sounds  
Creaks and Clicks:  
The 3/16" and 5/16" steel may creak or click when  
the stove heats up and cools down - this is normal.  
Blower Sounds:  
The blower will make a slight "humm" as it  
pushes air through the stove.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Your Appliance  
19  
Hints for Burning  
Get the appliance hot before adjusting to low burn  
Use smaller pieces of wood during start-up and high burns to increase temperature  
Use larger pieces of wood for overnight or sustained burns  
Stack the wood tightly together to establish a longer burn  
Leave a bed of ashes (1/2" deep) to allow for longer burns  
Be considerate of neighbors & the environment: burn dry wood only  
Burn small, intense fires instead of large, slow burning fires when possible  
Learn your appliance's operating characteristics to obtain optimum performance  
Selecting Wood  
Wet  
Wood  
Dry  
Wood  
Dry Wood is Key  
Dry wood burns hot, emits less  
smoke and creates less creosote.  
Leads  
To  
Leads  
To  
Testing Wood Moisture  
Split wood stored in a dry area will  
be fully dry within a year. This  
insures dry wood. If purchasing  
wood for immediate use, test the  
wood with a moisture meter. Some  
experienced wood burners can  
measure wood moisture by  
knocking pieces together and  
listening for a clear "knock" and not  
a "thud".  
Less  
Heat  
More  
Heat  
Leads  
To  
Leads  
To  
More Smoke  
and Creostoe  
Less Smoke  
and Creostoe  
Why Dry Wood is Key  
Wet wood, when burned, must release water stored within the wood. This cools the fire, creates  
creosote, and hampers a complete burn. Ask any experienced wood burner and he or she will agree: dry  
wood is crucial to good performance.  
Wood Cutting and Storage  
Cut wood to length and  
chop into quarters.  
Store the wood off the ground in a  
covered area. Allow for airflow  
around the wood to dry the wood.  
Air Flow  
Air Flow  
Air Flow  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
Operating Your Appliance  
Troubleshooting  
Problem  
Possible Cause  
Open the bypass (pg. 15).  
Smoke Enters Room During  
Start-Up  
Open the air control (pg. 17).  
Cold Air Blockage - burn a piece of newspaper to  
establish a draft.  
If the flame is not getting enough air, a small crack in  
the door is all that is needed.  
Open the bypass (pg. 15).  
Kindling Does Not Start - Fire  
Smolders  
Open the air control (pg. 17).  
Not enough starter paper - use additional newspaper if  
necessary.  
If the flame is not getting enough air, a small crack in  
the door is all that is needed.  
Open the bypass before opening the door (pg. 15).  
Open the air control before opening the door (pg. 17).  
Smoke Enters Room While Re-  
Loading  
Let the air stabilize before fully opening the door. Then  
open the door approximately 1 inch. Let air go into the  
firebox for a few seconds. Once the smoke appears to  
be flowing up the chimney consistently, open the door.  
Insufficient Draft - Chimney height and outside  
conditions can negatively affect draft. In these cases a  
small amount of smoke may enter the home. Adding  
more pipe or a draft-inducing cap may help.  
Wood is Wet - see the section "Selecting Wood" on  
page 19 for details on wood.  
Stove Does Not Burn Hot Enough  
Make sure the air control is all the way open. Slide the  
control back and forth to insure the control is not stuck.  
Insufficient Draft - Chimney height and outside  
conditions can negatively affect draft. In these cases  
the fire may burn slowly. Adding more pipe or a draft-  
inducing cap may help.  
Stove is Not Up to Temperature - This is normal. The  
blower will come on when the stove is hot - usually 15  
to 30 minutes.  
Blower Does Not Run  
Electricity is Cut to the Blower - Check the household  
breaker or fuse to make sure it is operable.  
Depending upon wood, draft, and other factors, the  
burn time may be shorter then stated. Make sure the  
doors are sealing and not allowing air into the firebox -  
See the section "Door and Glass Inspection" on page  
22 for details.  
Stove Does Not Burn Long  
Enough  
Check the ash bed for coals. Often, coals are still  
glowing under a slight bed of flyash. By raking these  
into a pile you can re-start your stove quickly.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintaining Your Appliance  
21  
Failure to properly maintain and inspect your appliance may reduce the performance and life of the  
appliance, void your warranty, and create a fire hazard.  
Daily Maintenance (while stove is in use)  
Remove Ash (if necessary)  
Ash removal is not required once it builds up. 1/2" to 1" of ash may be desirable because it slows the  
burn rate. Generally, remove ash once it has built up over 1". Follow the directions below to remove  
ash.  
1
2
Let the stove cool completely (at least two hours after the last coal has extinguished).  
Place a cloth or cardboard protector over the hearth to catch ash and protect against  
scratching.  
3
Open the doors and scoop the ash into a metal container with a tight fitting lid. The  
closed container of ashes should be placed on a noncombustible floor or on the  
ground, away from all combustible materials, pending final disposal.  
ASHES  
Improperly disposed ashes lead to fires. Hot ashes placed in cardboard boxes, dumped in back yards,  
or stored in garages, are recipes for disaster.  
Wood-burning stoves are inherently dirty. During cleaning have a vacuum ready to catch spilled ash  
(make sure ash is entirely extinguished).  
There are vacuum cleaners specifically made to remove ash (even if the ash is warm). Contact your  
dealer for details.  
Clean the Glass (if necessary)  
This appliance has an airwash to keep the glass clean. However, burning un-seasoned wood or burning  
on lower burn rates leads to dirtier glass (especially on the sides). Clean the glass by following the  
directions below.  
Allow the stove to fully cool. Apply glass  
cleaner or soapy water to the inside of  
the glass. Wipe with newspaper or a  
paper towel.  
For Stubborn Creosote:  
Dip newspaper or a paper towel  
in cool ashes and wipe it on the  
glass. The ash acts as a light  
abrasive.  
The glass will develop a very slight haze over time. This is normal and will not affect viewing of the fire.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
Maintaining Your Appliance  
Monthly Maintenance (while appliance is in use)  
Make sure the appliance has fully cooled prior to conducting service.  
Door and Glass Inspection  
The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket  
to make sure it forms an air-tight seal to the firebox.  
The door can be lifted off the hinges if extensive repairs are conducted.  
Use wood stove gasket  
High-Temperature anti-sieze  
cement to re-adhere  
may be used on the door  
loose gasket.  
hinges to eliminate squeaks.  
Severely frayed or thread-bare  
gasket should be replaced.  
If the glass is damaged, replace  
it - see “Replacement Parts” for  
details.  
Side View of Door Handle  
Exploded View  
The door latch should pull the door  
against the face of the stove (but  
not so tight as to not allow full  
handle rotation). If the latch  
requires adjustment, follow the  
directions below.  
Door Cam  
Door  
Handle  
Door Cam  
Adjustment:  
To tighten, remove  
a washer from the  
inside of the door  
frame. To loosen,  
place an additional  
washers on the  
inside of the door  
Washers  
Use a 9/16"  
socket wrench to  
remove this nut.  
Door Frame  
frame or loosen  
the nut 1/2 turn.  
Creosote - Formation and Need for Removal  
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled  
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-  
burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote  
makes an extremely hot fire. The chimney and chimney connector should be inspected at least once  
every two months during the heating season to determine if a creosote buildup has occurred. If creosote  
has accumulated, it should be removed to reduce the risk of a chimney fire.  
If you are not certain of creosote inspection, contact your dealer or local chimney sweep for a full  
inspection. Excess creosote buildup may cause a chimney fire, that may result in property damage,  
injury, or death.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintaining Your Appliance  
23  
Yearly Maintenance  
Make sure the appliance has fully cooled prior to conducting service.  
Touch Up Paint  
Included with the owner's pack of this appliance is a can of Stove-Brite®  
paint. To touch up nicks or dulled paint, apply the paint while the appliance is  
cool. Sand rusted or damaged areas before preparation (use 120 grit  
sandpaper). Clean and dry the area to prepare the surface. Wait at least one  
hour before starting the appliance. The touched up area will appear darker  
than the surrounding paint until it cures from heat. Curing will give off some  
fumes while curing – open windows to ventilate.  
Touch-Up  
Paint  
Cleaning the Air Duct and Blower  
Use a vacuum to clean the air ducts (channels). This prevents dust from burning and creating odors.  
The optional blower should be vacuumed every year to remove any buildup of dust, lint, etc.  
Use a vacuum cleaner to  
remove any buildup on the  
screens of the blower.  
Firebrick and Baffle Inspection  
Use the illustration on page 25 as a reference for checking the following items. Make sure the appliance  
is cool before proceeding.  
Baffle Firebricks - check the bricks along the ceiling of the firebox to make sure they are intact and have  
no gaps between them. Slide the bricks to eliminate any gaps.  
Baffle Supports - make sure the front and back baffle supports in are place and not degraded. Slight  
scaling or rusting of the metal is normal.  
Secondary Air Tubes - Check the two air tubes and collars to make sure they are intact and not severely  
deteriorated. Slight scaling or rusting of the metal is normal. Make sure the push pins hold the air tubes  
in place.  
Floor and Wall Firebricks - replace any severely damaged firebrick along the side or floor of the firebox.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
Maintaining Your Appliance  
Door Parts  
7
1
2
3
8
4
5
6
12  
9
14  
10  
13  
1/8Hex Wrench  
# 20 Torx Driver  
11  
NOTE: Place the glass gasket around the  
perimeter of the door retainer.  
9/16" Wrench  
NOTE: Glue the door gasket  
to the door retainer.  
ID #  
Description  
Qty  
Part #  
ID #  
Description  
Qty  
Part #  
1
Door Shell - Black  
Door Shell - Brass  
Door Shell - Pewter  
Glass Gasket  
1
230-00578  
230-00579  
230-00577  
224-11086  
99900409  
224-14042  
99900410  
224-14052  
100-03501  
101-00007  
2
Glass (19-1/4" x 9-7/8")  
1
173-01001  
3
5
7
1
1
1
4
6
8
Door Retainer (w gasket)  
Door Gasket  
Spring - Black  
Spring - Brass  
Spring - Pewter  
Cam  
Glass Clips - Top  
Glass Clip - Bottom  
Set Screw  
1
1
1
224-23029  
99900406  
100-14122  
99300100  
100-04103  
99900417  
224-230022  
224-230021  
225-20038  
Gasket Cement  
Door Handle Asbly - Black  
Door Handle Asbly - Brass  
Door Handle Asbly - Pewter  
Washers  
9
11  
2
1
10  
12  
1
2
1
2
Nut, Brass  
13  
#8-32 3/8" Type F Screw  
8
225-20039  
14  
Replacing the Glass  
The glass must not contact the door retainer or glass clips directly. The glass gasket and glass clip  
gaskets insulate the glass to prevent cracking. Do not over-tighten the glass clips.  
See "Door Shell Installation" (pg. 29) for details on removing the door handle and shell. NOTE: The glass  
gasket is placed in the grove along the inside perimeter of the door retainer. Make sure the glass clip  
screws are all fully tightened - they must be flush with the door retainer for the door shell to install.  
Replacing the Door Gasket  
The door gasket inserts into the outer groove of the door retainer. Stove gasket cement holds it in place.  
Before installing, remove any residual cement. Lay the gasket in place (start at the lower left corner) and  
cut off any excess gasket (do not stretch the gasket. The cement fully cures with heat from the stove.  
You may need to open and close the door repeatedly to get the gasket to seat fully.  
Replacing the Door Handle  
See the illustration above for a component list (see pg. 24 for details on adjusting the door).  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintaining Your Appliance  
25  
Firebox Parts  
8
7
9
10  
1
2
6
10  
5
3
10  
10  
4
10  
10  
10  
10  
10  
10  
10  
10  
11  
10  
10  
12  
12  
ID #  
1
3
5Baffle  
7
9
Description  
Air Tubes & Sleeve  
Air Tube Retainer Sleeve  
Support,  
Damper Slider  
Damper Extension Rod with  
Pull Ring  
Brick, Cut - 8.25" x 4.5"  
Qty  
1
3
Part #  
ID #  
2
4
Description  
Air Tube Roll Pins  
Baffle Support, Front "Y"  
Damper Plate  
Damper Yoke  
Qty  
6
1
1
1
Part #  
98900210  
100-11001  
1
98900338  
98900334  
98900357  
99900277  
98900320  
98900315  
175-00001 (1)  
98900102 (9)  
251-00011  
Rear  
"T"  
999768  
1
1
8
10  
Brick - 9" x 4.5" un-cut  
15  
11  
2
251-00010  
12  
Brick, Cut – 6.25” x 4.5”  
2
Floor and Side Firebrick  
Do not pry firebrick - they chip and crack easily. Remove the floor firebricks first. The side firebrick  
are removed later because they are pinned in place by the floor firebrick. Clean the firebox prior to  
replacing the firebrick.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
Maintaining Your Appliance  
Baffle Removal & Replacement  
1
2
3
Lift up on the front portion of the front three firebricks.  
Lift the front baffle support “Y” and rotate it forward until it can be removed.  
Slide the center front firebrick forward and out the door opening. Then slide the side front  
firebricks towards the middle then out in the same manner.  
4
5
Slide the center baffle support forward and out of the firebox.  
Slide the rear firebrick forward and out of the firebox. NOTE: When the center rear firebrick are  
slid forward the damper plate will come to rest on the rear secondary air tube and rear air  
channel.  
6
7
Slide the damper slider all the way forward.  
Reach into the firebox and push up on the damper yoke until the damper yoke separates from the  
damper slider. Remove both the damper slider and damper plate by sliding them between the  
front two secondary air tubes.  
REPLACEMENT INSTRUCTIONS:  
1
2
Place the damper plate above the secondary air tubes in the rear center of the firebox.  
Position the damper slider so the damper yoke inserts into the two tubes on the damper slider  
(make sure to have correct orientation). Then slide the damper slider over the damper plate until  
both are centered in the firebox.  
3
Follow the instructions above in reverse order, starting with step number 5.  
Air Tube Removal & Replacement  
Air Tube Collar  
Air Tube  
Remove the left pin on the air tube collar  
a
Roll Pin  
Slide the air tube to the left, swing it  
down and remove from the firebox.  
b
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Limited 7 Year Warranty  
27  
To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase  
date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is  
defined as the equipment manufactured by Travis Industries, Inc.) to be defect-free in material and workmanship to the original purchaser from the date of  
purchase as follows:  
Check with your dealer in advance for any costs to you when arranging a warranty call.  
Mileage or service charges are not covered by this warranty. This charge can vary from store to store.  
Years 1 & 2 - COVERAGE: PARTS & LABOR  
Firebox Assembly:  
Ceramic Glass  
Re-Installation Allowance  
In cases where heater must be removed from home  
for repairs, a partial cost of re-installation is covered  
(pre-authorization required)  
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber  
Glass (breakage from thermal shock)  
Door Assembly:  
Firebrick  
Breakage from thermal shock  
Solid Brass or Cast Door, Latch Assembly, Glass Retainers  
One-Way Freight Allowance  
Plated Finish  
Plated Door, Legs, etc… See "Conditions & Exclusions" # 9 below.  
Accessories  
Legs, Pedestal, Panels, Blower  
One-way freight allowance on pre-authorized repair  
done at factory is covered.  
Air Control Assembly  
Slider Plate, Pressure Plate  
Exclusions:  
Paint, Gasketing  
Years 3 Through 5 - COVERAGE: PARTS & LABOR  
Firebox Assembly:  
Door Assembly:  
One-Way Freight Allowance  
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber  
Solid Brass or Cast Door, Latch  
Assembly, Glass Retainers  
One-way freight allowance on pre-authorized  
repair done at factory is covered.  
Air Control Assembly  
Slider Plate, Pressure Plate  
Exclusions:  
Paint, Gasketing, Plated Finish, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-Installation Allowance  
Years 6 & 7 - COVERAGE: PARTS ONLY  
Firebox Assembly:  
Door Assembly:  
Solid Brass or Cast Door, Latch Assembly, Glass Retainers  
Air Control Assembly  
Slider Plate, Pressure Plate  
Firebox, Baffle Supports, Air Tubes, Air Channels, Convection Chamber  
Exclusions:  
Paint, Gasketing, Plated Finish, Accessories (Legs, Pedestal, Panels, Blower), Glass, Firebrick, Re-Installation Allowance, One-  
Way Freight Allowance, Labor  
CONDITIONS & EXCLUSIONS  
1.This new  
appliance must be installed by  
a
qualified installer.  
It must be installed, operaitneda,ccoradnadncemwaitihnttahineeindstruacttionasllin tthimees  
Owner’s Manual. Any alteration, willful abuse, accident, neglect, or misuse of the product shall nullify this warranty.  
2.This warranty is nontransferable, and is made to the ORIGINAL purchaser, provided that the purchasreizedwTarsavismdaedaeler. through an autho  
3.Discoloration and some minor expansion, contraction, or movement of certain parts and resulting nofeiscet ,andi,sthenreofromrea,l notacnodverneodt  
under warranty. Over-firing (operation where the steel may glow red) of this appliance can cause serious damage and will nullify this warranty.  
a
de  
4.The warranty, as outlined within this document, does not apply to the chimney components or otheinr conNjuonc-Ttiroanviwsith athcecessories used  
installation of this product. If in doubt as to the extent of this warranty, contact your authorized Travis retailer before installation.  
5.Travis Industries will not be responsible for inadequate performance caused by environmental conditiobnusildinsgusc,hrooaf stopsn,ewairnbdy, hilltsreoers,  
mountains or negative pressure or other influences from mechanical systems such as furnaces, fans, clothes dryers, etc.  
6.This Warranty is void if:  
a.The unit has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals.  
b.The unit is subject to submersion in water or prolonged periods of dampness or condensation.  
c.Any  
limited to, improper chimney/venting installation.  
7.Exclusions to this Year Warranty include:  
damage  
to  
the  
unit,  
combustion  
chamber, heat exchanger  
or  
other  
components  
due  
to  
wateers, ult orf, buwt neoather  
damage wh  
7
injury, loss of use, damage, failure to functionsused,uiemprtooperaincsctidaellantti,on,naeltgelrigaetionnceo,r mi  
adjustment of the manufacturer's settings of components, lack of proper and regular maintenance, damage incurred while the appliance is in transit, alteration, or  
act of God.  
8.This  
7
Year warranty excludes damage caused by normal wear and tear, such as paint discolorastkioenting,ocrhipcpheipdpoinrgc,rackweodrn or torn ga  
firebrick, etc. Also excluded is damage to the unit caused by abuse, improper installation, modification of the unit, or the use of fuel other than that for which the  
unit is configured (use cord wood only).  
9.Damage to brass or plated surfaces caused by fingerprints, scratches, melted items, or other efxatceernsafrlomstohuercuesse ofleafbtrasoivne the sur  
cleaners is not covered in this warranty. Damage to the surfaces from over-firing (operation where the steel may glow red) is not covered in this warranty.  
10.TRAVIS INDUSTRIES, INC. is free of liability for any damages caused by the appliance, as well as inconveniencemaetxeprieanlss.esIncaidnedntal or  
consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply.  
11.This warranty does not cover any loss or damage incurred by the use or removal of any component or apparTatruasvistoapoprliafnrocemwitthheout the  
express written permission of TRAVIS INDUSTRIES, INC. and bearing a TRAVIS INDUSTRIES, INC. label of approval.  
12.Any statement or representation of Travis products and their performance contained in Travis advertising, packrea,goinrgprilniteterdatmu aterial is not part of  
this 7 year warranty.  
13.This warranty is automatically voided if the appliance’s serial number has been removed or altered in anncye iswuasye. dIf fotrhceomamppelricaial purposes,  
it is excluded from this warranty.  
14.No dealer, distributor, or similar person has the authority to represent or warrant Travis products beyond theed wteirthmins thciosnwtaairnranty. TRAVIS  
INDUSTRIES, INC. assumes no liability for such warranties or representations.  
15.Travis Industries will not cover the cost of the removal or re-installation of hearths, facing, mantels, venmtipnogneonrtso. ther co  
16.If for any reason any section of this warranty is declared invalid, the balance of the warranty remains hiner ecflafeucstesanshdallarllemoat in in effect.  
17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied,  
are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein.  
IF WARRANTY SERVICE IS NEEDED:  
1.If you discover  
a
problem that you believe is covered by this warranty, you MUST REPORT it YtoS, giyvoinugr theTmravpirsoof doef aler WITHIN 30  
purchase, the purchase date, and the model name and serial number.  
2.Travis Industries has the option of either repairing or replacing the defective component.  
3.If your dealer is unable to repair your appliance’s defect, he may process  
a
warranty claim throinucglhudinTgRthAeVnISameINoDf USTRIES, IN,C.  
the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your  
appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC.,  
at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated  
within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES,  
INC., to your regional distributor, or dealership.  
4.Check with your dealer in advance for any costs to you when arranging  
can vary from store to store.  
a
warranty call. veMreildeabgyethisowrarrasnetryv.icTehis cchhaarrggees are not  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Listing Label  
Listing Label  
DO NOT REMOVE THIS LABEL  
Listed Solid Fuel Burning Appliance  
Suitable for use in masonry fireplaces.  
NER-QA219,TL-116  
MODEL:  
FREEDOM BAY (FLUSH BAY-96)  
SERIAL  
NUMBER  
Tested to: UL-1482/UL-907  
Report No. 6009 (May 1994)  
PREVENT HOUSE FIRES - Install and use only in accordance with the  
manufacturer's installation and operating instructions. Contact your local  
building or fire officials about restrictions and installation inspection in your  
area. Refer to local building codes and manufacturer's instructions for  
precautions required for passing a chimney through a combustible wall or  
ceiling. Do not run a chimney connector through a combustible wall or ceiling.  
Do not connect this unit to a chimney flue serving another appliance.  
Clearances may be reduced by methods specified in NFPA 211, listed wall  
shields, pipe shields, or other means approved by local building or fire officials.  
Minimum Clearances  
to Combustible Materials  
Fireplace Insert Installation  
Insert Clearance Diagram  
MANTEL  
Freedom Bay  
K
L
K. Mantle  
32.0 in.  
M
N
INSERT  
16  
with Mantle Shield  
L. Top Facing  
19.0 in.  
30.0 in.  
17.0 in.  
15.0 in.  
13.5 in.  
8
HEARTH EXTENSION  
with Shield  
M. Adjacent Sidewall  
N. Side Facing  
Front 16.0 in.  
Sides 08.0 in.  
COMPONENTS REQUIRED FOR MASONRY FIREPLACE INSTALLATION:  
Surround Panels.  
Direct flue connection is optional. Do not remove bricks or mortar from  
masonry fireplace.  
Note: Replace glass with 5mm neoceramic or ceramic glass only.  
For use with solid wood fuels only. Operate only with feed door closed - open to  
feed fire only. Do not use a grate or elevate fire - build fire directly on the hearth.  
Manufactured By:  
4800 Harbour Pointe Blvd. SW Mukilteo,  
U.S. ENVIRONMENTAL PROTECTION AGENCY  
Certified to comply with July 1990 particulate emission standards.  
Date of Manufacture  
2004 2005 2006 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.  
DO NOT REMOVE THIS LABEL  
Made in U.S.A.  
IGN 0228  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Equipment  
29  
Door Shell Installation  
1. Removethedoorretainershippinglatchfollowingthedirectionsbelow.  
Standard  
Screwdriver  
Rotate this shaft  
1/4 turn clockwise  
until the door  
unlatches.  
Swing the door retianer open. Remove and  
discard the shipping latch and nut.  
Shipping Latch  
Door Retainer  
9/16" Wrench  
2. Placethedoorshellfacedownonanon-scratchingsurface. Liftthedoorretaineroffthehinges.  
Insert the retainer into the door shell following the directions below. Note how the door shell is guided  
into place  
Door Retainer  
Door Shell  
The indent on the door retainer slides into  
the clip on the door shell (on both sides).  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
Optional Equipment  
3. Attach the retainer to the shell following the directions below.  
Make sure the door retainer is centered on the door shell.  
You can gauge the alignment by looking at the gaps here.  
1/8” Hex Wrench  
Once the door is aligned, tighten  
the two set screws on the bottom  
of the door shell to secure the  
door retainer.  
NOTE: in rare cases the door retainer may not line up with  
4. Attach the door handle  
following the directions to  
the right.  
the door shell, preventing the door handle from lining up  
correctly. To adjust the position horizontally, loosen the set  
screws (see step 3) and adjust the door retainer position. To  
adjust vertically, remove the retainer and adjust the clips on  
the door shell (see step 2).  
5. Replace the door on the  
hinges and latch the door.  
6. Attach the ashlip trim and  
side frames following the  
directions below.  
9/16" Wrench  
Slide the ashlip trim  
into place then  
tighten the five set  
screws on the  
Insert the screws  
through the face and  
nuts (the nuts are used  
as spacers) and secure  
to the side frames.  
bottom of the ashlip  
to secure.  
5/16”  
Socket  
1/16Hex Wrench  
Side Frame  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Equipment  
31  
Surround Panels  
NOTE: Install the door shell (and side frames) prior to installing the surround panels.  
SURROUND PANEL SIZE  
8"  
10"  
12"  
HEIGHT  
29-1/2"  
31-1/2"  
33-1/2"  
WIDTH  
45-3/8 "  
49-3/8 "  
53-3/8 "  
PART #  
99300293  
99300294  
99300295  
Stove Top  
Installation Instructions  
b
a
Rotate the panel back  
Top of Insert  
1. With the insert 12” from the  
fireplace, install the side  
surround panels (see the  
directions to the right).  
Place two U-Nuts (included  
with the insert) over the inside  
flange on one of the side  
and place it so the inside  
flange fits inside the side  
convection jacket. Note  
how the stove top fits  
into the notch.  
surround panels (flat side in).  
Side  
Convection  
Jacket  
2. Adjust the position of the  
side panels so they are: 1)  
flush with the bottom of the  
insert; 2) both the same  
distance back from the  
front of the insert; 3)  
Notch  
Back Side  
of Side  
Surround  
Panel  
perpendicular to the floor  
(use the top panel, if  
necessary, to judge  
alignment). Tighten the  
screws that hold the side  
panels in place.  
The flat side  
faces inwards.  
c
3. Place the insert into the  
fireplace and connect the  
flue (if using a positive or  
direct connection). Install  
the top panel and trim  
following the directions  
below.  
Attach the side panels with the two screws  
included with the insert. The screws pass  
through the side convection jacket and  
attach to the U-Nuts. Do not tighten the  
screws fully until the panels are aligned.  
Micro (1/16”)  
Standard  
Screwdriver  
Insulation Installation  
(required only for face seal  
installations)  
Spring  
Clips  
Top Trim  
"L" Bracket  
Top  
1. With the insert drawn 6"  
from the fireplace, glue the  
insulation strip included  
with the insert to the back  
of the panels using RTV  
silicon or stove gasket  
cement. The insulation  
should be installed so it  
overlaps the fireplace  
Panel  
Right Side  
Trim  
Optional Trim Installation:  
Insert one leg of each "L" bracket into the top  
and side trim piece. Align the trim to form a  
precise corner, then tighten the two set  
screws with a small standard screwdriver.  
Slide the trim over the panels. Place the  
spring clips behind the panels at the locations  
shown. This keeps the trim tight against the  
panel.  
opening to form a seal  
between the panels and  
the fireplace face. Let the  
silicon or cement dry.  
Optional Knock-Out  
An optional knock-out is provided on both  
sides if the power cord is routed behind the  
surround panel.  
Install the top panel so the tabs insert  
into the joggle clips on the top panel  
2. Push the insert into the fireplace, allowing the insulation to form a seal between the panels and the  
fireplace. Use a screwdriver to tuck any exposed insulation behind the panels.  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32  
Index  
Air Control (Burn Rate) ...................................17  
Air Tube Part Number ....................................25  
Air Tube Removal & Replacement ....................26  
Ash Disposal ................................................21  
Baffle Parts ..................................................25  
Baffle Removal and Replacement.....................26  
Blower Cleaning............................................23  
Blower Does Not Run (Troubleshooting) ............20  
Blower Installation .........................................10  
Blower Operation (optional) .............................18  
Burn Rate ....................................................17  
Chimney Cleaning .........................................22  
Chimney Inspection (Creosote) ........................22  
Cleaning the Ash...........................................21  
Cleaning the Glass ........................................21  
Clearances ..................................................9  
Creosote Check ............................................22  
Daily Maintenance.........................................21  
Dimensions..................................................6  
Door and Glass Inspection ..............................22  
Door Assembly .............................................24  
Door Gasket Replacement ..............................24  
Door Handle Replacement ..............................24  
Door Opening...............................................14  
Door Parts ...................................................24  
Draft Performance .........................................10  
Emissions....................................................6  
EPA Approval...............................................6  
Features......................................................6  
Fire Starting .................................................16  
Firebox Assembly..........................................25  
Firebox Parts................................................25  
Firebrick and Baffle Inspection .........................23  
Firebrick Removal & Replacement ....................25  
Floor Protection Requirements (Hearth) .............9  
Glass Cleaning .............................................21  
Glass Replacement .......................................24  
Hearth (Floor Protection).................................9  
Heating Specifications....................................6  
Hints for Burning ...........................................19  
Installation (planning) .....................................7  
Installation Options ........................................6  
Installation ...................................................7  
Listing Label.................................................28  
Maintenance ................................................21  
Masonry Fireplace.........................................9  
Monthly Maintenance .....................................22  
Noise (Normal Operating Sounds) ....................18  
Opening the Door..........................................14  
Operation ....................................................14  
Over-Firing the Stove .....................................14  
Overnight Burn .............................................18  
Paint (Touch-Up Paint) ...................................23  
Paint Curing .................................................14  
Re-Loading the Stove.....................................18  
Safety Label.................................................28  
Safety Precautions ........................................4  
Smell ..........................................................14  
Smoke Enters Room (Troubleshooting)..............20  
Sounds (Normal Operating Sounds)..................18  
Starting a Fire...............................................16  
Stove Does Not Burn Long Enough...................20  
Stove is Not Hot Enough (Troubleshooting) ........20  
Table of Contents..........................................3  
Touch-Up Paint.............................................23  
Troubleshooting (Operation) ............................20  
Warranty Card ..............................................2  
Warranty .....................................................27  
Wood..........................................................19  
Yearly Maintenance .......................................23  
© Travis Industries  
100-01163  
4041129  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Krown Manufacturing Answering Machine Model Krown 100 User Manual
Laser Switch PW USBACDC User Manual
Liebherr Freezer CS 1400 7082 663 00 User Manual
Life Fitness Treadmill 93T XXXX 09 User Manual
Lightolier Indoor Furnishings 100IFIC User Manual
Lincoln Electric Welding System IM10023 User Manual
Magnavox DVR MDR535H User Manual
Maytag Clothes Dryer W10388780A User Manual
Memorex DVD Player MVDP1085 User Manual
Memorex Stereo System MX3905 User Manual