The 812 OP/H is designed to provide composite  
sync, composite blanking, and color subcarrier for  
system applications which require 4Vpp drive  
pulses and 2Vpp subcarrier. Each of the output  
pulses is rise-time controlled to EIA standards and  
will drive a 75 Ohm load at its specified voltage.  
The subcarrier output is filtered for low harmonic  
distortion and is driven by a discrete amplifier. The  
812 OP/H will reside in the SPG-812 chassis  
alongsidevariousanaloganddigital modules-upto  
six modules per chassis.  
When the 812 OP/A analog black burst module is  
running in its free-run mode a front panel control  
adjusts the frequency of the Voltage Controlled  
Crystal Oscillator (VCXO). This device features a  
stability of 2.5ppm over the operating temperature  
range of 0° to 70° C.  
The rear panel view of the SPG-812 is shown on  
the back page, showing two 812 OP/H installed  
in the cell # 5 and # 6 (as viewed from the rear).  
An 812 OP/K is installed in cell # 3. Cell #1 is  
dedicated for tone, analog and AES. Cell # 2 is  
dedicated for gen-lock or the master time base,  
812 OP/A, B, C or D. A mixture of analog or  
digital in the same frame depends on the  
specific module chosen. The rear panel  
accommodates a connector for remote control of  
the test pattern generator. Two test pattern  
generators may reside in the same frame, one  
local and one remote.  
Whengen-lockingto incoming video, theSPG-812  
chassis will have either an analog 812 OP/C, gen-  
lock to analog black or a 812 OP/D digital genlock  
module in slot #2. This module places the timing  
pulses down the motherboard buss as reference.  
The 812 OP/H pulse generator module then uses  
these pulses to lock the PLL on the module and  
reset the vertical and horizontalcounterswithin the  
complex programmable logic devices. This times  
up all counters by an external reference.  
Power supply voltage fault indication is  
accomplished by a circuit that monitors all three  
supply voltages and turns off the green LED if  
one or any is lower then a nominal value.  
The PCO-818 automatic pulse change-over modules operate as independent or synchronized operation.  
Two PCO-818 change-over chassis may be interlinked to cause all modules to switch should a failure  
occur in the master generator.  
LINK  
ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, MO 63703-7668  
Phone 573 334 4433 FAX 573 334 9255  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Brush Cutter RCF2760 and RCF2772 User Manual
Learning Resources Baby Toy LER 0351 User Manual
Legacy Car Audio Cooktop LCDCS94 User Manual
Life Fitness Bicycle Accessories clsr 0xxx1 01 User Manual
Life Fitness Home Gym SM41 User Manual
Magma DVD Recorder MDR 24 96 User Manual
Magnavox DVD VCR Combo ZV450MW8A User Manual
Mellerware Convection Oven 24825 User Manual
Mellerware Hair Clippers 20800 User Manual
Michelin GPS Receiver X970 User Manual