Linear Switch WS15Z 1 User Manual

WS15Z-1  
Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Scene  
and NWI Capable, Wall Mounted Switch, 3-Way, Series 300  
WS15Z-1 AND THE LOAD MUST SHARE THE SAME PROPRIETARY NEUTRAL  
WHITE  
BLACK  
NEUTRAL  
120 VAC  
LOAD  
15 AMPS  
MAXIMUM  
BLUE  
LINE  
SCORED TAB WILL  
BREAK FLUSH WITH  
EDGE OF PLASTIC  
PUSH ON  
PUSH OFF  
PUSH TOP OR  
BOTTOM OF PADDLE  
SWITCH TO CONFIGURE  
GROUND  
GREEN  
Shown with supplied decorative trim plate  
STATUS LED  
NOTE: This module must be “included in the Network” only where it will be permanently installed. The proper operation of this node in the  
mesh network is dependent on it knowing its location with respect to other nodes.You cannot “test bench” configure this module.  
WS15Z-1 WALL MOUNTED SWITCH  
• To add a node: NWI: Tap the button once. This can be done upon  
power-up of the node to be included, or once the controller is prepared  
to add all nodes to the network. Classic inclusion:Tap the button twice  
• To remove a node: Tap the button twice  
STEP 3. You should see an indication on your Controller that the “device  
was included” in the network.  
Linear’s family of Z-Wave certified wireless lighting controls (switches,  
dimmers, outlets and plug-in modules) brings a new level of intelligent  
wireless capability to commercial and residential environments.  
The Z-Wave wireless protocol is an international wireless standard for  
remote home automation, security and other applications. Embedded in  
each device, the Z-Wave smart chip enables two-way RF communication  
among hundreds of Z-Wave enabled devices, allowing products and  
services from multiple manufacturers to work seamlessly.  
NOTE: If you have trouble adding the WS15Z-1 to a group it may be  
that the Home ID and Node ID were not cleared from it after testing.  
You must first “RESET UNIT” with your controller to remove it from  
the network.  
Linear Z-Wave products are easy to install, and allow dealers to create  
an integrated wireless network with nearly limitless expansion and  
interoperability with security and health monitoring systems, energy  
management, home entertainment, appliances, and more.  
Although adding it to a group includes it in the network, removing it from  
a group does not remove it from the network. If removed from a group,  
it functions as a repeater (only). “RESET UNIT” removes it completely  
from the network.  
DANGER! SHOCK HAZARD. Read and understand these  
instructions before installing. This device is intended for installation in  
accordance with the National Electric code and local regulations in the  
United States, or the Canadian Electrical Code and local regulations  
in Canada. It is recommended that a qualified electrician perform this  
installation. Make sure the load controlled by the switch does not exceed  
1800 watts. For indoor use only. Retain instructions for future use.  
BASIC OPERATION  
(Local Control)  
The switch paddle on the WS15Z-1 allows the user to:  
Turn the attached load on or off.  
Tapping top of switch turns the load attached ON.  
Tapping bottom of switch turns the load attached OFF.  
• Pressing and holding switch does not effect the load attached to the  
WS15Z-1, but will allow dimming and brightening of Z-Wave dimmers  
if associated (see below for details)  
INSTALLATION  
Wire this Switch in place of a current wall switch according to the diagram  
above. When used, WT00Z-1’s are required to be wired to the same  
line (or neutral) which is also wired to the master unit as well as the  
load being controlled, and not wired to any other neutral. If multiple  
neutrals are tied together in one box, separate the neutrals to preserve  
the integrity of the WS15Z-1 circuit. Caution! Do not wire unit “live” (with  
power on the circuit) and do not allow the yellow wire to contact line  
voltage, neutral or ground or you will damage the device. Refer to your  
Controller operating instructions to add this module under the command  
of the Wireless Controller.  
LED Indication  
The LED on the WS15Z-1 will turn ON when the load attached is OFF, to  
act as a night light. However, the LED can be user configured to turn ON,  
when the load attached is ON, if so desired.  
Remote Control  
The WS15Z-1 will respond to BASIC and BINARY commands that are  
part of the Z-Wave system. Refer to your controller’s instructions as to  
whether your controller can transmit those commands.  
INCLUDING/EXCLUDING WS15Z-1 TO THE NETWORK  
Internal Circuit Protection  
STEP 1. Prepare the Controller to include a unit to the network by adding  
it to a group (method of adding a node to the network). Refer to controller  
instructions.  
The WS15Z-1 internal circuitry is protected by an internal fuse. This  
internal fuse is factory serviceable only.Check your home circuit breakers  
before concluding that the product must be returned to manufacturer for  
repair at a nominal charge.  
STEP 2. The WS15Z-1 must be in its permanently installed location.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lasko Patio Heater 5409 User Manual
Lenovo Laptop B560 User Manual
Lenovo Tablet 064652U User Manual
Lincoln Electric Portable Generator IM972 User Manual
Magnadyne Remote Starter X11 User Manual
Marantz Car Amplifier RC9200 RC5400 RC3200 RC1400 User Manual
Marley Engineered Products Ventilation Hood 2438 User Manual
Marvel Industries Beverage Dispenser Refrigerated Wine Chiller User Manual
Maytag Clothes Dryer MEDE900VJ1 User Manual
Mellerware Blender 85200A User Manual