PRODUCT DESCRIPTION
REMOVE MOUNTING PLATE
The DXT-72 is a photoelectric smoke alarm with a built-in
transmitter designed for use with Linear’s DX Format receivers.
When smoke is detected, the alarm sounds a loud local
alarm. Twenty seconds after the local alarm sounds, the built-
in transmitter sends a digitally coded wireless signal to its
companion receiver. The wireless signal will be repeated every
20 seconds as long as smoke is still present.
DXT-72
TWIST MOUNTING
PLATE TO
UNLOCK
BY
REMOVE
MOUNTING
PLATE
WIRELESS
PHOTOELECTRIC
SMOKE
The digital DX code format features over a million possible
codes.The DX transmitters are precoded at the factory to unique
codes, so no field coding is required.The DXT-72 can send three
different codes: alarm, test and low battery.
ALARM
For versatility, any transmitter can be programmed into any
receiver channel. Receivers must be programmed to the
transmitter’s code before system testing and operation. Refer to
the receiver’s instructions for details on programming.
Installation
Instructions
The unit is powered by two 9-volt alkaline or lithium batteries.
These batteries are supplied with the transmitter and can power
the unit for up to two years. If the battery voltage drops below
a preset level the alarm will sound low battery beeps and a
low battery signal will be sent to the receiver every hour (some
receivers can report low battery, others cannot).
(760) 438-7000
☞ NOTE: After replacing batteries, press transmitter test
button to reset “low battery circuit”.
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
DXT-72 FEATURES
INSTALL BATTERIES
CHOOSE ALARM LOCATION
PRESS TRANSMITTER TEST BUTTON
AFTER INSTALLING BATTERIES
TO PRE-SET LOW BATTERY CIRCUIT
TRANSMIT LED
TRANSMITTER
TEST BUTTON
TRANSMITTER
BOARD
CONNECT AND INSTALL
TWO 9-VOLT DURACELL
ALKALINE MN1604 OR
ULTRALIFE LITHIUM U9VL
BATTERIES
BATTERY
HOLDING
CUPS
INSTALL MOUNTING PLATE
PROGRAM RECEIVER
MOUNT ALARM ON PLATE
MATCH UP
ALIGNMENT
TABS
REFER TO RECEIVER'S INSTRUCTIONS
TO PREPARE RECEIVER TO ACCEPT THE
TRANSMITTER'S CODE
SCREW
ANCHORS
FOR WALLBOARD
PRESS TRANSMITTER
TEST BUTTON
TO SEND SIGNAL
OR
PLASTIC
TWIST SMOKE
SINGLE-GANG
ELECTRICAL
BOX
ALARM CLOCKWISE
TO LOCK TO MOUNTING
PLATE