Linear Smoke Alarm DXS 72 User Manual

PRODUCT DESCRIPTION  
REMOVE MOUNTING PLATE  
The DXS-72 is a photoelectric smoke alarm with a built-in  
transmitter designed for use with Linear’s DXS and DX Format  
receivers. When smoke is detected, the alarm sounds a loud  
local alarm. Twenty seconds after the local alarm sounds, the  
built-in transmitter sends a digitally coded wireless signal to its  
companion receiver. The wireless signal will be repeated every  
20 seconds as long as smoke is still present.  
DXS-72  
DXS  
FORMAT  
By  
TWIST MOUNTING  
PLATE TO  
UNLOCK  
REMOVE  
MOUNTING  
PLATE  
WIRELESS  
PHOTOELECTRIC  
SMOKE  
The digital DXS code format features over a million possible  
codes. The DXS transmitters are precoded at the factory to  
unique codes, so no field coding is required. The DXS-72 can  
send three different codes: alarm, test and low battery status.  
For versatility, any transmitter can be programmed into any  
receiver channel. Receivers must be programmed to the  
transmitter’s code before system testing and operation.  
Refer to the receiver’s instructions for details on programming.  
The unit is powered by two 9-volt alkaline or lithium batteries.  
These batteries are supplied with the transmitter and can power  
the unit for up to two years. Every hour, the DXS-72 will send a  
status transmission to the receiver. The hourly signal updates  
the receiver to the transmitter’s condition. By monitoring status  
transmissions, the receiver can determine if a transmitter has a  
low battery or has been removed from the system. If the battery  
voltage drops below a preset level the alarm will sound low  
battery beeps and a low battery signal will be sent to the receiver  
with status reports (some receivers can report low battery status,  
others cannot).  
ALARM  
Installation  
Instructions  
(760) 438-7000  
USA & Canada (800) 421-1587 & (800) 392-0123  
Toll Free FAX (800) 468-1340  
NOTE: After replacing batteries, press transmitter test button to  
reset “low battery circuit”.  
DXS-72 FEATURES  
INSTALL BATTERIES  
CHOOSE ALARM LOCATION  
PRESS TRANSMITTER TEST BUTTON  
AFTER INSTALLING BATTERIES  
TO RESET LOW BATTERY CIRCUIT  
TRANSMIT LED  
TRANSMITTER  
TEST BUTTON  
TRANSMITTER  
BOARD  
CONNECT AND  
INSTALL TWO  
9-VOLT BATTERIES  
9-VOLT BATTERY TYPES:  
EVEREADY 216, 522, OR 1222  
DURACELL MN1604  
GOLD PEAK 1604P, 1604S  
ULTRALIFE LITHIUM U9VL  
BATTERY  
HOLDING  
CUPS  
INSTALL MOUNTING PLATE  
PROGRAM RECEIVER  
MOUNT ALARM ON PLATE  
MATCH UP  
ALIGNMENT  
TABS  
REFER TO RECEIVER'S INSTRUCTIONS  
TO PREPARE RECEIVER TO ACCEPT THE  
TRANSMITTER'S CODE  
SCREW  
ANCHORS  
FOR WALLBOARD  
PRESS TRANSMITTER  
TEST BUTTON  
TO SEND SIGNAL  
OR  
PLASTIC  
TWIST SMOKE  
SINGLE-GANG  
ELECTRICAL  
BOX  
ALARM CLOCKWISE  
TO LOCK TO MOUNTING  
PLATE  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kyocera All in One Printer KM C3130 User Manual
Lasko Fan 1850W User Manual
Logitech Computer Keyboard MK360 User Manual
Logitech Speaker 984 000193 User Manual
Magnavox Flat Panel Television 15MF605T User Manual
Mamiya Digital Camera M645 1000S User Manual
Maytag Iron MLI7500AAW User Manual
McCulloch Blower MCB2205 User Manual
Mellerware Toaster 24440 User Manual
Middleby Cooking Systems Group Oven UB 6T User Manual