WARNING: THIS
PRODUCT SHOULD NOT
BE USED IN LIFE
1. PRODUCT DESCRIPTION
2. SYSTEM OVERVIEW
3. DISPLAYED CONDITIONS
Linear’s Xtended Range FM receivers and transmitters are designed for use in various
wireless remote control applications. When the Model XR-16 receiver detects a signal
from its companion transmitters, it will verify the digital code, activate the correct output
channel, and trigger the remote device connected to the receiver.
XR-16
XTENDED RANGE
SIXTEEN CHANNEL
SUPERVISED
STATIONARY
RECEIVER
TRANSMITTER CONDITION
SAFETY APPLICATIONS.
EXAMPLE
TRANSMITTERS
FCC Rules allow
unlicensed high-power
transmissions at or near
the operating frequency
of this product which
may interfere with, or
even disable, normal
operation of this radio
device.
The XR-16 receiver has full supervision capabilities. If the “status” option for a channel
is selected, the receiver expects hourly status signals from that channel’s transmitter.
If these signals cease, the receiver will indicate trouble by activating its status output
after four hours. Contact supervision allows the receiver’s outputs to follow the
transmitter’s inputs, each output staying activated as long as each transmitter input is
activated. Alternately, an “auto-restore” option can be selected in the transmitter,
causing a momentary receiver output each time any transmitter input is activated. If
the transmitter sends a low battery signal, the receiver’s low battery output will activate.
SIGNAL
INDICATOR
POWER
INDICATOR
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
Power for the XR-16 receiver can come from an external 12 VDC power supply (Linear
Model T-1224DC) or from a 12-volt battery. A diode protects the unit from reverse
power polarity. The XR-16 draws about 50 mA standby, and about 350 mA when all
outputs are active. The alarm, low battery and status outputs are solid state and are
capable of switching up to 100 mA @ 24 VDC to ground (programmable as N/O or
N/C). The receiver’s relay can activate with all signals, or just alarm signals. It provides
isolated N/O and N/C relay contacts capable of switching a maximum of 1 Amp @
24 VDC.
TRANSMITTER ALARM
TRANSMITTERS WILL CAUSE THIS CONDITION WHEN THEY SEND A
VIOLATION SIGNAL. THE CONDITION WILL REMAIN UNTIL A RESTORE
SIGNAL IS SENT, UNLESS THE TRANSMITTER IS SET AS "AUTO
RESTORE". THE TRANSMITTER'S CHANNEL OUTPUT WILL BE FAULTED
AS LONG AS THIS CONDITION IS DISPLAYED.
For Use With
MODEL
XT-1
MODEL
XT-4
Linear’s XR Series
Xtended Range
Transmitters
TRANSMITTER LOW BATTERY
ANY TRANSMITTER SENDING A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION. DISPLAY WILL REMAIN UNTIL A SIGNAL OCCURS FROM THE
SAME TRANSMITTER WITH A GOOD BATTERY.
Two antennas (sold separately) are available for the XR-16. The Model ANT-1A is an
8-inch “rubber duck” antenna for short range applications (less than 1 mile). The ANT-1
requires a Model CON-180A connector to mate the antenna to the receiver. The Model
ANT-2 is a 3-foot whip antenna for use in long range or difficult installations where more
range from the XR-16 is required. A common 9-foot 1/4 wave CB whip antenna can
also be used with the XR-16 for maximum range.
AN UNLIMITED NUMBER
OF TRANSMITTERS CAN
BE USED WITH THE XR-16
TRANSMITTER STATUS ALERT
EACH RECEIVER CHANNEL CAN BE SET AS SUPERVISED OR NON-
SUPERVISED. IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS
FROM A TRANSMITTER PROGRAMMED TO A SUPERVISED CHANNEL
FOR FOUR HOURS, THIS CONDITION WILL BE DISPLAYED. DISPLAY WILL
CLEAR THE NEXT TIME A SIGNAL IS RECEIVED FROM THE
TRANSMITTER.
Installation
Instructions
Two 8-position switches set the unit’s system code. This code must be matched in the
XR-16’s transmitters. There are 65,536 different system codes possible. The two
8-position option switches select the status supervision option for each of the
16 channels.
The receiver is housed in a metal enclosure with an SO-239 antenna connector. Three
displays are visible through a window on the case. The left two displays show the
channel number, the right display shows the condition. The display scrolls through all
the channel numbers with a condition. The right decimal point lights when the receiver
has power. During reception, the center decimal point lights. Two internal test points
are provided for signal strength and audio monitoring.
16 CHANNEL
OUTPUT
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
DASHES WILL MOVE ACROSS THE
DISPLAY WHILE THE RECEIVER IS IDLE
XR-16 RECEIVER
CONTROL PANEL
4. COMPONENT LOCATIONS
5. MOUNT RECEIVER
6. CONNECT ANTENNA
7. TERMINAL BLOCK DETAILS
XR-16 TERMINALS
POWER INPUT
7"
USE ANT-1A ANTENNA FOR
SHORT RANGE (LESS THAN
1 MILE) APPLICATIONS
SYSTEM CODE
SWITCHES "A" & "B"
ANT-1A
ANTENNA
GND
+12 VDC
COM
FOR CONNECTION TO A REGULATED DC POWER SOURCE.
THE POWER INPUT CAN BE FROM 11-16 VDC ONLY.
RELAY OUTPUT
STATUS OPTION
SWITCHES 1-16
MOUNTING
PATTERN
DRY CONTACTS, FORM C, 1 AMP @ 24 VDC MAXIMUM
RATING. JUMPER SELECTABLE TO ACTIVATE AS LONG AS
ANY OUTPUT IS ACTIVE, OR AS LONG AS ANY CHANNEL
OUTPUT IS ACTIVE.
5-1/8"
5-1/8"
N/C
CON-180A
STRAIGHT
CONNECTOR
N/O
TRANSMITTER
CHANNEL
NUMBER
GND
STATUS OUTPUT
ACTIVATES WHEN ANY CHANNEL PROGRAMMED TO
EXPECT STATUS TRANSMISSIONS DOES NOT RECEIVE ANY
STATUS SIGNALS FOR FOUR HOURS. REMAINS ACTIVE
UNTIL SIGNALS ARE RECEIVED AND ALL STATUS
STS ALM
LOW BAT
GND
ANTENNA
CONNECTOR
USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER
TRANSMITTER
CONDITION
INDICATIONS ("S" ON CONDITION DISPLAY) ARE CLEARED.
USE 3-FOOT LONG ANT-2
ANTENNA FOR LONGER
RANGE APPLICATIONS OR
DIFFICULT INSTALLATIONS
CH16
CH15
CH14
CH13
GND
LOW BATTERY OUTPUT
ACTIVATES WHEN ANY TRANSMITTER SENDS A LOW
BATTERY SIGNAL. REMAINS ACTIVE UNTIL A GOOD
BATTERY SIGNAL IS RECEIVED AND ALL LOW BATTERY
INDICATIONS ("L" ON CONDITION DISPLAY) ARE CLEARED.
RECEIVER CHANNEL OUTPUTS
CH12
CH11
CH10
CH9
EACH OUTPUT ACTIVATES WHEN ANY TRANSMITTER
PROGRAMMED FOR THAT CHANNEL IS IN THE VIOLATED
(ALARM) CONDITION. REMAINS ACTIVE UNTIL ALL
TRANSMITTERS PROGRAMMED TO THAT CHANNEL ARE
RESTORED AND ALL ALARM INDICATIONS ("A" ON
CONDITION DISPLAY) ARE CLEARED.
MOUNT ANTENNA AS HIGH AS POSSIBLE
(A METAL MOUNTING POLE IS
RECOMMENDED)
TEST POINTS
SIGNAL
LEVEL
ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS
AUDIO
IF THE TRANSMITTER IS PROGRAMMED FOR AUTO-
RESTORE, THE OUTPUT WILL BE MOMENTARY,
ACTIVATING FOR ONLY TWO SECONDS.
GND
OUTPUT
CH8
AN 18-FOOT RG-58 CABLE IS SUPPLIED
WITH THE ANT-2 KIT. UP TO 50 FEET OF
RG-58 CAN BE USED. USE RG-8 FOR UP
TO 100-FOOT CABLE RUNS.
GROUND
CH7
NOTES:
CH6
1. OUTPUTS CAN CONNECT TO ZONE INPUTS ON AN
ALARM CONTROL PANEL OR MANY OTHER TYPES OF
EXTERNAL DEVICES.
CH5
TERMINAL
BLOCK
GND
2. ALL GND TERMINALS ARE COMMON GROUND AND
CONNECTED TOGETHER.
CH4
TO XR-16
CH3
3. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH
OUTPUT RETURNS TO ANY COM TERMINAL.
OUTPUT
OPTION
JUMPER
CH2
RELAY
OPTION
JUMPER
MOUNT ANTENNAS AS FAR AS POSSIBLE FROM
COMPUTERS TO MINIMIZE INTERFERENCE
GENERATED BY THE COMPUTER
WIRING
KNOCKOUTS
CH1
4. EACH SOLID STATE OUTPUT CAN SWITCH UP TO
100 mA @ 24 VDC MAXIMUM.
Download from Www.Somanuals.com. All Manuals Search And Download.
|