Linear Medical Alarms PERS 3600B User Manual

PERS-3600B  
PERSONAL  
EMERGENCY  
REPORTING  
SYSTEM  
BY  
BY  
INSTALLATION & OPERATION  
INSTRUCTIONS  
USA & Canada (800) 421-1587 & (800) 392-0123  
(760) 438-7000 - Toll Free FAX (800) 468-1340  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. CONTROL AREA FEATURES  
2. REAR SIDE AND BOTTOM FEATURES  
HOME INDICATOR  
• LIGHTS WHEN ACTIVITY TIMER IS ON  
NOTE: THE CONSOLE IS  
BACKUP  
BATTERY  
ACCESS DOOR  
SHIPPED WITH REMOVABLE  
LABELS COVERING  
SOME OF THE REAR  
CONNECTIONS  
CONSOLE REAR  
• LIGHT IS OFF WHEN ACTIVITY TIMER IS OFF  
• BLINKS SLOWLY WHEN LESS THAN 15 MINUTES  
REMAIN ON THE ACTIVITY TIMER  
STATUS INDICATOR  
• NORMALLY OFF  
• LIGHTS WHEN ANY TRANSMITTERS ARE  
MISSING (SUPERVISORY)  
• BLINKS SLOWLY WHEN ANY TRANSMITTERS  
• BLINKS QUICKLY WHEN THE ACTIVITY  
TIMER HAS EXPIRED  
HOME BUTTON  
HAVE A LOW BATTERY  
• PRESS TO RESET ACTIVITY TIMER  
• PRESS FOR 5 SECONDS TO TURN  
ACTIVITY TIMER AND REMINDER RPT. OFF  
• IF ACTIVITY TIMER IS OFF,  
PRESS FOR 5 SECONDS  
TO TURN ACTIVITY TIMER AND  
REMINDER REPORT ON  
• USED IN TEST MODE TO  
-
POWER  
SWITCH  
RECORD AND PLAYBACK  
REMINDER MESSAGES  
LOCAL  
PHONE  
JACK  
TEST  
BUTTON  
EXTERNAL SPEAKER  
AND RELAY OUTPUT  
TERMINALS  
EXTERNAL  
SPEAKER  
SENDING INDICATOR  
EXTERNAL  
MICROPHONE  
TERMINALS  
• NORMALLY OFF  
• FLASHES WHEN CONSOLE  
IS PLACING A CALL  
TELEPHONE  
LINE JACK  
BYPASS JUMPER  
(FACTORY INSTALLED)  
POWER INDICATOR  
• LIGHTS WHEN AC IS PRESENT  
• BLINKS SLOWLY WHEN BATTERY IS CHARGING  
• BLINKS QUICKLY WHEN AC IS ABSENT  
(CONSOLE ON BATTERY POWER)  
CONSOLE BOTTOM  
HELP BUTTON  
• PRESS AND HOLD TO TRIGGER  
THE EMERGENCY ALARM  
• PRESS DURING RING FOR  
SPEAKERPHONE MODE  
16VAC 1.25 AMP  
PLUG-IN  
TRANSFORMER  
• OFF IN TEST AND SETUP MODES  
• PRESS DURING SPEAKERPHONE  
MODE TO DISCONNECT  
• PRESS WHILE IN TEST MODE TO  
CONNECT THE CONSOLE TO A PC  
FOR LOCAL PROGRAMMING WITH  
THE RA-2400 SOFTWARE  
CANCEL BUTTON  
STOPS ALARM  
• ADDS CANCEL TO AN ALARM  
REPORT IN PROGRESS  
• PRESS IMMEDIATELY AFTER  
EMERGENCY TO PREVENT REPORT  
• CLEARS INDICATORS  
STOPS TROUBLE BEEPER  
• PRESS FOR 5 SECONDS TO ADD  
A TRANSMITTER  
HOME BUTTON COVER  
• HIDES THE HOME BUTTON IF THE  
ACTIVITY TIMER IS NOT USED  
BATTERY FUSE COVER  
FUSE TYPE: 2AG  
FUSE RATING: 1AMP  
TWO-WAY  
AUDIO VOLUME  
DIGITAL VOICE  
VOLUME  
(REMOVE IF INSTALLED TO RECORD  
AND PLAYBACK REMINDER MESSAGES  
• CLEARS REMINDER MESSAGE  
3. TELEPHONE CONNECTIONS  
4. BACKUP BATTERY INSTALLATION  
REMOVE THE  
BATTERY DOOR  
1
2
BE SURE THAT  
THE POWER  
SWITCH IS OFF  
REAR OF  
CONSOLE  
ON  
OFF  
PUSH THE RELEASE TABS IN  
AND SLIDE THE DOOR UPWARD  
CONNECT THE RED LEAD  
TO POSITIVE AND THE  
BLACK LEAD TO THE  
NEGATIVE BATTERY  
TERMINAL  
3
CONNECT THIS JACK  
TO THE LOCAL  
TELEPHONE  
CONNECT THIS JACK  
TO THE TELEPHONE LINE  
CAUTION: CONNECTING  
THE BATTERY LEADS BACKWARDS  
WILL BLOW THE BATTERY FUSE  
FUSE TYPE: 1 AMP 2AG  
RESIDENT'S  
TELEPHONE  
JACK  
BATTERY TYPE:  
12-VOLT, 1.2 AMP HOUR  
SLIDE THE BATTERY  
4
INTO THE CASE AND  
REPLACE THE  
BATTERY DOOR  
IMPORTANT: WHEN REPLACING THE  
BATTERY, THE OLD BATTERY MUST  
BE RECYCLED. DELIVER THE BATTERY  
TO AN APPROPRIATE RECYCLING FACILITY  
RESIDENT'S  
LOCAL TELEPHONE  
(OPTIONAL)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. TRANSFORMER INSTALLATION  
6. APPLY POWER - SELECT DIALING METHOD  
PLUG TRANSFORMER  
INTO AN UN-SWITCHED  
AC OUTLET  
1
SLIDE POWER  
SWITCH ON  
ON  
OFF  
NOTE: THE DEFAULT DIALING METHOD IS TONE DIALING  
IF REQUIRED, CHANGE THE DIALING METHOD BY PRESSING  
AND HOLDING THE HOME & CANCEL BUTTONS FOR 3 SECONDS  
WHILE SWITCHING THE POWER ON  
SECURE  
TRANSFORMER  
WITH SCREW  
2
• 7 BEEPS SOUND FOR PULSE DIALING  
8 BEEPS SOUND FOR TONE DIALING  
7. TRANSMITTER INSTALLATION OPTIONS  
8. INSTALLING SINGLE TRANSMITTERS  
ADDS ONE TRANSMITTER AT A TIME  
FOR ALL TWO-BUTTON TRANSMITTERS  
1
2
PRESS CANCEL BUTTON  
FOR 5 SECONDS  
• CONSOLE ANNOUNCES  
THAT IT IS READY TO  
LEARN TRANSMITTERS  
IT WILL  
ACTIVATE  
USING  
EITHER  
BUTTON  
WHEN IT IS  
INSTALLED  
WITH THE  
LEFT BUTTON  
WHEN IT IS  
INSTALLED  
WITH THE  
IT WILL ONLY  
ACTIVATE  
USING BOTH  
BUTTONS  
ACTIVATE TRANSMITTER  
• CONSOLE ANNOUNCES  
TRANSMITTER TYPE THEN  
REVERTS TO STANDBY MODE  
RIGHT BUTTON  
NOTE: IF THE CONSOLE'S MEMORY  
IS FULL, THE CONSOLE WILL ANNOUNCE  
"ERROR ZONES FULL"  
DXS-62A  
FOR DXS-31 STATIONARY TRANSMITTERS  
3
REPEAT STEPS 1 & 2 FOR ADDITIONAL  
TRANSMITTERS (UP TO 16 TOTAL)  
WHEN IT IS INSTALLED  
WITH THE JUMPER SET  
FOR DELAY  
WHEN IT IS INSTALLED  
WITH THE JUMPER SET  
FOR INSTANT  
NOTE: PRESS CANCEL BEFORE TRANSMITTING TO RETURN  
TO STANDBY MODE WITHOUT ENTERING A TRANSMITTER  
• THE CONSOLE WILL ANNOUNCE ITS STATUS  
THE CONSOLE WILL RETURN TO STANDBY MODE AUTOMATICALLY  
WHEN A TRANSMITTER IS LEARNED OR AFTER 30 SECONDS  
HAS ELAPSED  
IT WILL  
FUNCTION  
AS EMERGENCY  
IT WILL  
FUNCTION  
AS ACTIVITY  
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER  
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED  
TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER.  
FOR MODEL DXS-32: CUT JUMPER (INSTANT TX) FOR USE  
AS AN ACTIVITY TX. SEE DXS-32 INSTALLATION INSTRUCTIONS  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. INSTALLING MULTIPLE TRANSMITTERS  
10. TESTING TRANSMITTERS  
ADDS MULTIPLE TRANSMITTERS  
1
PRESS TEST BUTTON  
• CONSOLE ANNOUNCES  
TEST MODE  
1
PRESS TEST BUTTON  
• CONSOLE ANNOUNCES  
TEST MODE  
2
PRESS TEST BUTTON AGAIN  
• CONSOLE ANNOUNCES ITS  
READY TO LEARN TRANSMITTERS  
2
ACTIVATE EACH OF THE  
CONSOLE'S TRANSMITTERS,  
ONE AT A TIME  
NOTE: EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD  
TRANSMITTER MODE, THE CONSOLE WILL BE READY TO INSTALL A  
TRANSMITTER IN THE NEXT AVAILABLE SENSOR ZONE LOCATION.  
THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION NUMBER.  
3
ACTIVATE TRANSMITTER  
• CONSOLE ANNOUNCES  
THE TRANSMITTER TYPE  
3
THE CONSOLE WILL ANNOUNCE  
THE TRANSMITTER'S TYPE  
AND ZONE NUMBER AND ANY  
SUPERVISORY CONDITIONS  
FOR THE TRANSMITTER  
NOTE: IF THE CONSOLE'S MEMORY  
IS FULL, THE CONSOLE WILL ANNOUNCE  
"ERROR ZONES FULL"  
REPEAT STEPS 2 & 3 FOR  
ADDITIONAL TRANSMITTERS  
(UP TO 16 TOTAL)  
DXS-62A  
4
5
PRESS CANCEL TO RETURN TO STANDBY MODE  
• THE CONSOLE WILL ANNOUNCE ITS STATUS  
THE CONSOLE WILL RETURN TO STANDBY MODE  
AUTOMATICALLY AFTER 3 MINUTES  
4
PRESS CANCEL TO RETURN TO STANDBY MODE  
• THE CONSOLE WILL ANNOUNCE ITS STATUS  
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER  
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED  
TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER  
THE CONSOLE WILL RETURN TO STANDBY MODE  
AUTOMATICALLY AFTER 3 MINUTES  
11. ERASING TRANSMITTERS  
12. RECORDING REMINDER MESSAGES  
RECORDING REMINDER MESSAGES  
1. PRESS AND RELEASE THE TEST BUTTON  
CAUTION: ALL TRANSMITTERS  
WILL BE ERASED!  
TO ENTER TEST MODE  
2. PRESS AND HOLD THE HOME BUTTON FOR  
5 SECONDS (BE READY TO RECORD)  
3. RECORD UP TO A 15 SECOND MESSAGE  
(SPEAK AT NORMAL VOLUME, TWO FEET FROM CONSOLE)  
4. PRESS THE HOME BUTTON TO STOP RECORDING  
5. PRESS THE HOME BUTTON AGAIN TO PLAY THE  
MESSAGE JUST RECORDED, PRESS THE HOME  
BUTTON TWICE AND HOLD IT AFTER THE 2ND PRESS  
TO RECORD ANOTHER MESSAGE IN THE NEXT  
AVAILABLE MESSAGE NUMBER  
1
PRESS AND HOLD THE TEST BUTTON FOR 5 SECONDS  
• CONSOLE ANNOUNCES "ZONE RESET"  
(ALL TRANSMITTERS ERASED)  
6. REPEAT STEPS 2-5 FOR ADDITIONAL MESSAGES  
(UP TO 8 MESSAGES ALLOWED)  
7. PRESS AND RELEASE THE CANCEL BUTTON TO  
EXIT TEST MODE  
TEST PLAYING REMINDER MESSAGES  
1. PRESS AND RELEASE THE TEST BUTTON  
TO ENTER TEST MODE  
2. PRESS AND RELEASE THE HOME BUTTON  
3. THE CONSOLE WILL ANNOUNCE EACH MESSAGE  
NUMBER, THEN PLAY THE RECORDED MESSAGE  
4. PRESS THE HOME BUTTON TO ADVANCE TO  
THE NEXT MESSAGE TO BE PLAYED  
5. PRESS AND RELEASE THE CANCEL BUTTON TO  
EXIT TEST MODE  
NOTE: TIME SCHEDULING FOR PLAYING REMINDER  
MESSAGES IS SET WITH THE RA-2400 SOFTWARE  
ERASING ALL REMINDER MESSAGES  
1. PRESS AND RELEASE THE TEST BUTTON  
TO ENTER TEST MODE  
2. PRESS AND HOLD THE HOME BUTTON FOR  
MORE THAN 10 SECONDS  
2
PRESS CANCEL TO RETURN TO STANDBY MODE  
• THE CONSOLE WILL ANNOUNCE ITS STATUS  
3. THE CONSOLE WILL ERASE ALL REMINDER MESSAGES  
AND PLAYBACK SCHEDULES  
4. PRESS AND RELEASE THE CANCEL BUTTON TO  
EXIT TEST MODE  
THE CONSOLE WILL RETURN TO STANDBY MODE  
AUTOMATICALLY AFTER 3 MINUTES  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. LOCAL PROGRAMMING WITH RA-2400  
PERFORM THE STEPS DETAILED IN THE  
14. SYSTEM OPERATION  
CONSOLE  
STANDING BY  
HOME LIGHT SHOWS  
ACTIVITY TIMER STATUS  
1
RA-2400/PERS REFERENCE GUIDE (P/N 224756)  
TO SET UP THE RA-2400 PROGRAM  
THE OTHER  
POWER  
LIGHT  
IS ON  
TO LOCALLY PROGRAM  
2
CONSOLE  
LIGHTS ARE  
NORMALLY  
OFF  
THE CONSOLE, CONNECT  
THE MODEM'S LINE JACK  
TO THE CONSOLE'S LINE  
JACK  
LINE-TO-LINE  
PRESS THE TEST BUTTON  
MOMENTARILY  
- IN CASE OF EMERGENCY -  
3
• CONSOLE ANNOUNCES  
TEST MODE  
START A LOCAL CONNECTION WITH  
THE RA-2400 SOFTWARE  
PRESS AND  
MOMENTARILY  
HOLD THE  
HELP BUTTON  
- OR -  
ACTIVATE  
AN EMERGENCY  
TRANSMITTER  
NOTE: CONSOLE WILL EXIT TEST MODE  
AUTOMATICALLY AFTER 3 MINUTES  
OR BY PRESSING THE CANCEL BUTTON  
PRESS TRANSMITTER  
BUTTON FOR AT LEAST  
2 SECONDS  
WHEN RA-2400 CONNECTION TIMER  
STARTS COUNTING DOWN,  
PRESS THE HELP BUTTON  
• THE CONSOLE ANNOUNCES  
"PHONE ON" WHEN THE CONSOLE  
HAS CONNECTED  
4
5
CONSOLE  
IN ALARM  
SENDING LIGHT  
FLASHES DURING  
COMMUNICATION  
THE CONSOLE  
ANNOUNCES  
EMERGENCY  
UNTIL THE CANCEL  
BUTTON IS PRESSED,  
CENTRAL STATION  
REPORT IS COMPLETE,  
OR THE SIREN TIME EXPIRES  
PRESS CANCEL TO  
STOP THE ALARM  
(ADDS CANCEL TO  
ALARM REPORT IN  
PROGRESS)  
PERFORM PROGRAMMING IN THE RA-2400 SOFTWARE, SEND AND SAVE  
THE ACCOUNT PROFILE, THEN DISCONNECT FROM THE CONSOLE  
15. ACTIVITY TIMER OPERATION  
16. AUDIO OPERATION  
1
ENABLING THE ACTIVITY TIMER  
PROGRAM THE CONSOLE FOR THE DESIRED AUDIO MODE:  
1) LISTEN-ONLY  
2) 2-WAY MANUAL  
1
PRESS THE HOME BUTTON FOR  
5 SECONDS TO TURN THE  
ACTIVITY TIMER ON  
3) 2-WAY VOICE ACTIVATED (DUPLEX)  
NOTE: THE ACTIVITY TIMER CAN  
BE ENABLED FOR 8, 12, OR  
24 HOURS, OR DISABLED BY  
PROGRAMMING  
AFTER THE CENTRAL STATION OPERATOR ACKNOWLEDGES THE  
COMMUNICATOR'S REPORT, THE CONSOLE WILL STOP ITS LOCAL  
ALARM AND SWITCH TO THE SELECTED AUDIO MODE FOR 90 SECONDS  
2
AUDIO OPERATION CAN ALSO BE ESTABLISHED BY CALLING THE  
CONSOLE TWICE AND KEYING IN THE FOUR DIGIT REMOTE AUDIO  
PASSWORD FOLLOWED BY THE # KEY (SEE SECTION #22)  
NOTE: TO TURN THE ACTIVITY TIMER OFF, PRESS THE HOME BUTTON FOR FIVE  
SECONDS, THIS WILL ALSO TURN ON/OFF REMINDER REPORTING IF REMINDER  
SCHEDULE TIME OUT REPORT IS ENABLED IN THE RA-2400 SOFTWARE (ACTIVITY  
TIMER CAN BE DISABLED SEPARATELY IN RA-2400 ALARMS PROGRAMMING)  
3
CENTRAL STATION OPERATOR OR AUDIO CALLER:  
USE THESE KEYS ON A TELEPHONE SET TO CONTROL THE CONSOLE'S  
AUDIO MODE (IN CENTRAL STATION, CONNECT A TELEPHONE TO THE  
SAME TELEPHONE LINE AS THE CENTRAL STATION RECEIVER)  
2
3
ACTIVITY TIMER RUNNING  
TIME RUNNING OUT  
THE HOME INDICATOR WILL BLINK &  
THE CONSOLE ANNOUNCES EVERY  
10 SECONDS WHEN LESS THAN  
15 MINUTES OF TIME REMAIN  
THE HOME INDICATOR WILL LIGHT,  
SHOWING THAT THE ACTIVITY  
TIMER IS ENABLED  
ALL  
PRESS "9" TO  
AUDIO  
DISCONNECT THE CALL  
MODES  
PRESS "3" TO LISTEN  
2-WAY  
MANUAL  
AUDIO  
MODE  
PRESS "1" TO TALK  
4
RESETTING ACTIVITY TIMER  
THE SUBSCRIBER NEEDS TO  
PRESS THE HOME BUTTON OR  
TRIGGER AN ACTIVITY  
TRANSMITTER BEFORE THE  
TIMER EXPIRES TO PREVENT  
AN INACTIVITY REPORT  
THE "1" AND "3" KEYS ARE NOT USED IN LISTEN-ONLY AUDIO MODE  
THE "1" AND "3" KEYS CAN BE USED IN 2-WAY VOICE ACTIVATED MODE.  
USING THEM WILL CAUSE THE SYSTEM TO SWITCH TO 2-WAY MANUAL  
MODE. PRESSING "8" RESTORES 2-WAY VOICE ACTIVATED MODE.  
PRESSING ANY KEY OTHER THAN "9" WILL EXTEND THE AUDIO TIME  
90 MORE SECONDS  
PRESSING THE HOME BUTTON  
RESTARTS THE TIMER  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
17. SPEAKERPHONE OPERATION  
PROGRAM THE CONSOLE TO ENABLE SPEAKERPHONE MODE  
18. SUPERVISORY CONDITIONS  
TRANSMITTER LOW BATTERY  
WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE  
CONSOLE'S STATUS INDICATOR WILL BLINK SLOWLY  
1
NOTE: SPEAKERPHONE MODE CAN ONLY BE USED ON INCOMING CALLS  
AND WILL NOT FUNCTION WHEN THE CONSOLE IS OPERATING FROM  
BACKUP BATTERY POWER. ATTEMPTING TO ANSWER WHILE THE CONSOLE  
IS ON BACKUP POWER WILL CAUSE AN EMERGENCY ALARM.  
TRANSMITTER SUPERVISORY  
IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS  
TO REPORT STATUS IN A 24 HOUR PERIOD, THE CONSOLE'S  
STATUS INDICATOR WILL LIGHT  
WHILE THE TELEPHONE IS RINGING, ACTIVATING AN EMERGENCY  
TRANSMITTER OR PRESSING THE HELP BUTTON WILL SEIZE THE  
TELEPHONE LINE  
2
LOW CONSOLE BACKUP BATTERY  
THE CONSOLE WILL TEST ITS BACKUP  
BATTERY EVERY 8 HOURS. IF THE BATTERY  
WHEN TROUBLE EXISTS,  
TESTS LOW, THE POWER INDICATOR WILL  
BLINK SLOWLY WHILE THE CONSOLE  
CHARGES THE BATTERY.  
THE CONSOLE WILL ANNOUNCE  
THE CONDITION EVERY  
HOUR UNTIL CLEARED  
THE SYSTEM WILL BEGIN 2-WAY VOICE ACTIVATED MODE FOR AUDIO  
COMMUNICATIONS  
3
WARNING: THE CONSOLE WILL NOT BE ABLE  
TO REPORT AN EMERGENCY WHILE THE  
SPEAKERPHONE MODE IS ACTIVE  
NOTE: TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE,  
PRESS EITHER THE HELP BUTTON OR THE BUTTON ON AN EMERGENCY  
TRANSMITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE  
BUTTONS AGAIN TO REPORT THE EMERGENCY.  
CLEARING STATUS INDICATIONS  
PRESS THE CANCEL BUTTON TO  
CLEAR THE STATUS INDICATOR  
AND STOP THE ANNUNCIATION  
NOTE: A TROUBLE  
CONDITION WILL LIKELY OCCUR AGAIN  
UNTIL THE PROBLEM IS FIXED  
THE CONSOLE WILL END AUDIO COMMUNICATIONS WHEN EITHER:  
4
THE CONSOLE WILL REPORT THESE SUPERVISORY CONDITIONS  
TO THE CENTRAL STATION IF ENABLED IN THE COMMUNICATOR  
PROGRAMMING (AUTOMATIC FULL-SYSTEM CONSOLE SUPERVISORY  
REPORTS CAN ALSO BE SENT AT 1, 7, OR 30 DAY INTERVALS)  
• THE HELP BUTTON IS PRESSED  
• ANY EMERGENCY TRANSMITTER IS ACTIVATED  
• THE AUTO-DISCONNECT TIMER RUNS OUT (PROGRAMMABLE  
FOR 15, 30, OR 60 MINUTES)  
19. OPTIONAL OUTPUT CONNECTIONS  
20. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS  
USE A SMALL  
SCREWDRIVER  
TO PUSH ON THE  
TERMINAL LOCKS  
TO ALLOW THE  
WIRE TO SLIDE  
INTO THE TERMINAL  
HOLE  
REMOVE  
JUMPER  
WIRE  
SHIELD  
WIRE  
NOTE: NOT TO BE USED IN  
UL INSTALLATIONS  
CONSOLE MAIN  
CONNECT WIRES TO  
RELAY TERMINALS  
CONSOLE MIC TERMINALS  
TERMINAL BLOCK  
EXTERNAL MICROPHONE (+)  
1 - +12 VDC @ 100 Ma  
MICROPHONE COMMON (-)  
2 - RELAY NORMALLY OPEN  
NOTE: THE CONSOLE IS SHIPPED WITH  
REMOVABLE LABELS COVERING SOME  
OF THE REAR CONNECTIONS  
3 - RELAY NORMALLY OPEN  
4 -  
GROUND  
5 - EXTERNAL SPEAKER  
NOTE: REMOVE  
JUMPER WHEN  
USING A UL  
LISTED MODEL  
RSM-1 OR OTHER  
UL LISTED  
CONSOLE  
TERMINAL BLOCK  
TERMINALS 2 & 3  
ARE A FORM "A" DRY  
CONTACT RELAY  
RATED 24 VOLTS AT  
1 AMP MAXIMUM  
NOTE: NOT TO BE USED IN  
UL INSTALLATIONS  
USE  
SHIELDED  
TWISTED PAIR  
WIRE FOR  
MICROPHONE  
SPEAKER  
NOISEMAKER OR  
VISUAL INDICATOR  
TERMINALS 4 & 5  
HAVE A FACTORY  
INSTALLED JUMPER  
DO NOT REMOVE  
UNLESS USING  
A UL LISTED MODEL  
RSM-1 OR OTHER  
UL LISTED SPEAKER  
SPKR  
SPKR  
EXTERNAL  
POWER SUPPLY  
MIC (-)  
MIC (+)  
LINEAR  
MODEL RSM-1  
RSM-1  
TERMINALS  
RSM-1 TERMINAL BLOCK  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. NON-VOICE PROMPT BEEP LEGEND  
WHEN VOICE PROMPTS ARE DISABLED,THE CONSOLE WILL SOUND BEEPS  
TO INDICATE VARIOUS CONDITIONS  
23. WIRELESS INSTALLATION TIPS  
WALLBOARD AND  
WOOD STUDS  
CONSTRUCTION  
1 BEEP...................TRANSMITTER ADDED TO A SENSOR ZONE  
1 LONG BEEP........SENSOR ZONES FULL  
MATERIALS WILL  
AFFECT RADIO RANGE  
90% - 100%  
OF FULL POWER  
2 BEEPS.................CONSOLE IN STANDBY MODE, ACTIVITY TIMER ON  
3 BEEPS.................CONSOLE IN STANDBY MODE, ACTIVITY TIMER OFF  
4 BEEPS.................CONSOLE IN TEST MODE  
CONCRETE WITH STEEL  
REINFORCEMENT OR  
METAL LATH AND PLASTER  
LIGHT CONCRETE  
OR BRICK  
5 BEEPS.................CONSOLE IN LEARN TRANSMITTER MODE  
6 BEEPS.................CONSOLE HAS ERASED ALL TRANSMITTERS  
7 BEEPS.................PULSE DIALING HAS BEEN SELECTED FOR THE CONSOLE  
8 BEEPS.................TONE DIALING HAS BEEN SELECTED FOR THE CONSOLE  
65% - 95%  
OF FULL POWER  
10% - 70%  
OF FULL POWER  
22. REMOTE AUDIO COMMUNICATIONS  
TO ESTABLISH REMOTE AUDIO COMMUNICATIONS WITH THE CONSOLE:  
CENTRALLY LOCATE CONSOLE  
1. DIAL THE NUMBER OF THE PHONE LINE THAT THE CONSOLE IS CONNECTED TO,  
ALLOW IT TO RING THREE TIMES, THEN HANG UP  
2. WAIT ABOUT 10 SECONDS, THEN CALL THE CONSOLE A SECOND TIME  
CONSOLE LOCATION WILL  
AFFECT RADIO RANGE  
RIGHT  
3. WHEN THE CONSOLE ANSWERS, A TONE WILL SOUND FOR ABOUT 8 SECONDS  
4. WHEN THE TONE ENDS, ENTER THE REMOTE AUDIO PASSWORD (DEFAULT 1234)  
FOLLOWED BY THE # KEY  
THE CONSOLE WILL BEGIN AUDIO COMMUNICATIONS (2-WAY DUPLEX, 2-WAY MANUAL,  
OR LISTEN-ONLY) DEPENDING ON THE CONSOLE’S PROGRAMMING  
TRANSMITTERS AT THE  
OTHER END OF THE HOUSE  
MIGHT BE TOO FAR AWAY  
SEE SECTION 16 FOR AUDIO COMMUNICATION OPERATION DETAILS  
NOTE: IFTHE CONSOLE AUDIO IS SETTO “NONE” REMOTE AUDIO COMMUNICATIONS  
WILL NOT FUNCTION  
WRONG!  
SPECIFICATIONS  
CODING FORMATS  
LINEAR LIMITED WARRANTY  
This Linear product is warranted against defects in material and workmanship for twelve  
(12) months.This warranty extends only to wholesale customers who buy direct from Linear  
or through Linear’s normal distribution channels. Linear does not warrant this product to  
consumers. Consumers should inquire from their selling dealer as to the nature of the  
dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC  
for consequential damages arising out of or in connection with use or performance  
of this product or other indirect damages with respect to loss of property, revenue, or  
profit, or cost of removal, installation, or reinstallation. All implied warranties, including  
implied warranties for merchantability and implied warranties for fitness, are valid only until  
the warranty expires. This Linear LLCWarranty is in lieu of all other warranties express  
or implied.  
DX CODE 24-BIT A1D PPM 1,048,567 CODES  
DXS CODE 24-BIT A1D PPM 1,048,567 CODES  
POWER REQUIREMENTS  
PRIMARY SUPPLY 16 VAC 1.25 AMP PLUG-IN TRANSFORMER  
BACKUP SUPPLY 12 VOLT 1.2 AMP/HOUR BATTERY  
NORMAL OPERATING CURRENT 120 mA  
ALARM OPERATING CURRENT 190 mA  
BACKUP OPERATION DURATION 30 HOURS MINIMUM  
BATTERY LIFE EXPECTED 3 YEARS  
BACKUP SUPPLY OPERATING CURRENT 40 mA  
BATTERY FUSE 1 AMP, TYPE 2AG  
All products returned for warranty service require a Return Product Authorization Number  
(RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other  
important details.  
RF CHARACTERISTICS  
RECEIVER TYPE DUAL-DIVERSITY SUPERHETERODYNE  
RF SENSITIVITY -100 dBm TYPICAL  
RADIO FREQUENCY 315 Mhz  
MAXIMUM RANGE 400 FEET LINE-OF-SIGHT, OPEN RANGE  
UL LISTED FOR 150 FEET  
IMPORTANT WIRELESS INFORMATION  
Linear radio controls provide a reliable communications link and fill an important need in  
portable wireless signaling. However, there are some limitations which must be observed.  
COMMUNICATOR  
COMMUNICATOR FORMATS 4 BY 2 (GENERAL OR POINT-TO-POINT),  
ADEMCO CONTACT ID  
For U.S. installations only: The radios are required to comply with FCC Rules and  
Regulations as Part 15 devices. As such, they have limited transmitter power and  
therefore limited range.  
UL TESTED WITH SURGARD SGMLRG-DG  
CENTRAAL STATION RECEEIVER  
DIALING TONE OR PULSE  
DIALING DELAY 0 OR 15 SECONDS  
REMOTE PROGRAMMING PASSWORD 6 DIGITS  
A receiver cannot respond to more than one transmitted signal at a time and may be  
blocked by radio signals that occur on or near their operating frequencies, regardless of  
code settings.  
NOTE:THE INSTALLER MUST  
REMOTE COMMUNICATIONS PASSWORD 4 DIGITS  
VERIFY COMPATIBILITY  
ACCOUNT NUMBER LENGTH 4 DIGITS  
PRIMARY TELEPHONE NUMBER 20 DIGITS  
BETWEEN THE PERS-3600B AND  
Changes or modifications to the device may void FCC compliance.  
THE UL LISTED DIGITAL ALARM  
SECONDARY TELEPHONE NUMBER 20 DIGITS  
SUPERVISORY TELEPHONE NUMBER 20 DIGITS  
CONSOLE STATUS REPORT OPTIONAL 1, 7 OR 30 DAY REPORT  
COMMUNICATOR RECEIVER  
Infrequently used radio links should be tested regularly to protect against undetected  
interference or fault.  
A general knowledge of radio and its vagaries should be gained prior to acting as a  
wholesale distributor or dealer, and these facts should be communicated to the ultimate  
users.  
CONSOLE  
OPERATING TEMPERATURE 32°-120° F (0-49° C)  
HELP ALARM DURATION 1-30 MINUTES  
ACTIVITY TIMER PERIOD 8, 12, OR 24 HOURS  
AUDIO LISTEN-ONLY, 2-WAY MANUAL, 2-WAY VOICE  
ACTIVATED (DUPLEX) SPEAKERPHONE  
RELAY OUTPUT N.O. @ 24 VOLT AC/DC 1 AMP  
MAXIMUM, NEC CLASS II CIRCUITRY  
Copyright © 2012 Linear LLC  
228305 AX1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lennox Hearth Bluetooth Headset BT135 User Manual
LG Electronics Microwave Oven MS3447GR User Manual
LG Electronics Washer TC51 User Manual
Lincoln Electric Welder 248HO User Manual
Margaritaville Blender DM3000 User Manual
Maytag Clothes Dryer MED5900TW0 User Manual
Maytag Washer W10270227 User Manual
McCulloch Brush Cutter MAC 250 B User Manual
Mellerware Electric Shaver 20610 User Manual
Metro DataVac Vacuum Cleaner DATAVAC 3ESD User Manual