Download from Www.Somanuals.com. All Manuals Search And Download.  
1. FRONT PANEL FEATURES  
2. REMOVING BOTTOM COVER  
TROUBLE INDICATOR  
• NORMALLY OFF  
EMERGENCY BUTTON  
• PRESS AND HOLD TO TRIGGER  
THE EMEREGNCY ZONE  
• PRESS DURING RING FOR  
SPEAKERPHONE MODE  
• PRESS DURING SPEAKERPHONE  
MODE TO DISCONNECT  
• LIGHTS WHEN ANY TRANSMITTERS ARE MISSING  
(SUPERVISORY)  
BLINKS SLOWLY WHEN ANY TRANSMITTERS  
HAVE A LOW BATTERY  
TO ACCESS THE INSIDE OF THE CONSOLE  
PRESS THE TWO LOCKING TABS IN AND  
REMOVE THE CONSOLE'S BOTTOM COVER  
POWER INDICATOR  
CLEAR BUTTON  
STOPS ALARM  
• LIGHTS WHEN AC IS PRESENT  
BLINKS SLOWLY WHEN BATTERY IS CHARGING  
BLINKS QUICKLY WHEN AC IS ABSENT  
(CONSOLE ON BATTERY POWER)  
• OFF IN TEST AND SETUP MODES  
• ADDS CANCEL TO AN ALARM  
REPORT IN PROGRESS  
• PRESS IMMEDIATELY AFTER  
EMERGENCY TO PREVENT REPORT  
• CLEARS INDICATORS  
STOPS TROUBLE BEEPER  
• PRESS FOR 5  
SECONDS TO ADD  
A TRANSMITTER  
REMOVE  
COVER  
PRESS  
TABS  
IN  
HOME BUTTON  
• PRESS TO RESET ACTIVITY TIMER  
• PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF  
• IF ACTIVITY TIMER IS OFF, PRESS FOR  
5 SECONDS TO TURN ACTIVITY TIMER ON  
HOME INDICATOR  
• LIGHTS WHEN ACTIVITY TIMER IS ON  
BLINKS SLOWLY WHEN LESS THAN 15 MINUTES  
REMAIN ON THE ACTIVITY TIMER  
BLINKS QUICKLY WHEN THE ACTIVITY TIMER HAS EXPIRED  
HOME BUTTON COVER  
• ADHESIVE BACKED PLATE TO  
HIDE THE HOME BUTTON IF THE  
ACTIVITY TIMER IS NOT USED  
SENDING INDICATOR  
• NORMALLY OFF  
• FLASHES WHEN CONSOLE IS PLACING A CALL  
3. CONSOLE BOTTOM FEATURES  
4. OPTIONAL VB-4B VOICE BOARD INSTALLATION  
PRESS-FIT MICROPHONE INTO  
ROUND MOUNTING HOLE  
2
1
CONNECT BLACK  
MICROPHONE WIRE  
TO CENTER  
12-VOLT 1.2 AMP/HOUR  
BACKUP BATTERY  
TERMINAL  
16 VAC 1.25 AMP  
PLUG-IN  
TRANSFORMER  
CONNECT RED  
MICROPHONE WIRE  
TO THIS TERMINAL  
3
4
EXTERNAL SPEAKER,  
RELAY OUTPUT, AND  
DIALER POWER  
OPTIONAL  
VB-4B VOICE BOARD  
TERMINALS  
1 AMP 2AG  
BATTERY FUSE  
(HIDDEN)  
SEAT  
MICROPHONE  
CAREFULLY ALIGN  
PINS TO CONNECTORS  
ON BOTH ENDS OF BOARD  
BE SURE THAT THE  
WHITE ARROWS ON  
AUDIO BOARD POINT  
TOWARD THE  
LOCAL  
PHONE  
JACK  
5
NOTE: POWER MUST  
BE OFF AND BATTERY  
SHOULD BE REMOVED  
OR DISCONNECTED  
BEFORE INSTALLING  
THE AUDIO BOARD  
BATTERY AREA  
PRESS BOARD  
COMPLETELY  
INTO CONNECTORS  
TELEPHONE  
LINE JACK  
POWER  
SWITCH  
TEST  
BUTTON  
NOTE: AFTER THE AUDIO BOARD  
IS INSTALLED AND ENABLED, THE  
CONSOLE WILL SPEAK INSTEAD  
OF BEEP DURING PROGRAMMING  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. OPTIONAL RELAY OUTPUT CONNECTIONS  
6. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS  
VB-4B  
VOICE  
BOARD  
FORM "A" DRY CONTACT RELAY  
24 VOLTS AT 1 AMP MAXIMUM  
5
NOISEMAKER OR  
VISUAL INDICATOR  
4 - RELAY NORMALLY OPEN  
3 - RELAY COMMON  
EXTERNAL  
POWER SUPPLY  
2
1
REMOVE  
JUMPER  
WIRE  
CONSOLE  
TERMINAL BLOCK  
CONSOLE  
TERMINAL BLOCK  
VB-4B TERMINAL BLOCK  
EXTERNAL MICROPHONE (+)  
MICROPHONE COMMON (-)  
CONSOLE MICROPHONE (+)  
5 - DIALER POWER  
4 - RELAY NORMALLY OPEN  
3 - RELAY COMMON  
CONNECT WIRES  
TO TERMINALS  
DIALER COMMON  
EXTERNAL SPEAKER  
2 -  
1 - EXTERNAL SPEAKER  
NOTE: REMOVE  
JUMPER WHEN  
USING AN  
USE  
SHIELDED  
TWISTED PAIR  
WIRE FOR  
MICROPHONE  
EXTERNAL SPKR  
NOTE: NOT  
TESTED BY UL  
SPKR  
SPKR  
ROUTE CABLE UNDER  
STRAIN-RELIEF CLAMP  
MIC (-)  
MIC (+)  
LINEAR  
MODEL RSM-1  
RSM-1  
TERMINALS  
RSM-1 TERMINAL BLOCK  
7. BACKUP BATTERY  
8. INSTALL TRANSFORMER  
TURN POWER  
1
CONNECT RED LEAD TO  
POSITIVE AND BLACK LEAD TO  
2
SWITCH OFF  
PLUG TRANSFORMER  
INTO AN UN-SWITCHED  
NEGATIVE BATTERY TERMINAL  
1
117 VAC OUTLET  
ON  
OFF  
BATTERY TYPE: 12-VOLT, 1.2 AMP/HOUR  
FIT BATTERY  
3
SECURE  
TRANSFORMER  
INTO CONSOLE  
2
WITH SCREW  
SLIDE DOWN  
THEN BACK  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. APPLY POWER - SELECT DIALING METHOD  
10. TRANSMITTER INSTALLATION OPTIONS  
TURN POWER  
SWITCH ON  
FOR ALL TWO-BUTTON TRANSMITTERS  
IT WILL  
ACTIVATE  
USING  
EITHER  
BUTTON  
WHEN IT IS  
INSTALLED  
WITH THE  
ON  
LEFT BUTTON  
WHEN IT IS  
INSTALLED  
WITH THE  
IT WILL ONLY  
ACTIVATE  
USING BOTH  
BUTTONS  
RIGHT BUTTON  
NOTE: THE DEFAULT DIALING METHOD IS TONE DIALING  
IF REQUIRED, CHANGE THE DIALING METHOD  
BY PRESSING AND HOLDING THE HOME & CLEAR  
BUTTONS WHILE SWITCHING THE POWER ON  
FOR DXS-31 STATIONARY TRANSMITTERS  
WHEN IT IS INSTALLED  
WITH THE JUMPER SET  
FOR DELAY  
WHEN IT IS INSTALLED  
WITH THE JUMPER SET  
FOR INSTANT  
IT WILL  
FUNCTION  
AS EMERGENCY  
IT WILL  
FUNCTION  
AS ACTIVITY  
FOR MODEL DXS-32: CUT JUMPER (INSTANT TX) FOR USE  
AS AN ACTIVITY TX. SEE DXS-32 INSTALLATION INSTRUCTIONS  
• 7 BEEPS SOUND FOR PULSE DIALING  
• 8 BEEPS SOUND FOR TONE DIALING  
11. INSTALLING SINGLE TRANSMITTERS  
12. INSTALLING MULTIPLE TRANSMITTERS  
ADDS MULTIPLE TRANSMITTERS  
ADDS ONE TRANSMITTER AT A TIME  
1
1
PRESS TEST BUTTON  
• 4 BEEPS SOUND  
(TEST MODE)  
PRESS CLEAR BUTTON  
FOR 5 SECONDS  
• 5 BEEPS SOUND  
(TX ADD MODE)  
2
PRESS TEST BUTTON AGAIN  
• 5 BEEPS SOUND  
(ADD TX MODE)  
2
ACTIVATE TRANSMITTER  
• 1 BEEP SOUNDS  
(TX ADDED)  
CONSOLE REVERTS  
TO OPERATE MODE  
NOTE: EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX MODE,  
THE CONSOLE WILL BE READY TO INSTALL A TRANSMITTER IN THE NEXT  
AVAILABLE SENSOR ZONE LOCATION. IF THE VB-4B VOICE BOARD IS  
INSTALLED, THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION  
NUMBER.  
ACTIVATE TRANSMITTER  
• 1 BEEP SOUNDS  
(TX ADDED)  
3
NOTE: IF THE CONSOLE'S MEMORY  
IS FULL, ONE LONG BEEP SOUNDS WHEN  
TRYING TO ADD A TRANSMITTER  
DXS-62A  
NOTE: IF THE CONSOLE'S MEMORY  
IS FULL, ONE LONG BEEP SOUNDS  
WHEN TRYING TO ADD A TRANSMITTER  
3
REPEAT STEPS 1 & 2 FOR ADDITIONAL  
TRANSMITTERS (UP TO 16 TOTAL)  
NOTE: PRESS CLEAR BEFORE TRANSMITTING TO RETURN  
TO OPERATE MODE WITHOUT ENTERING A TRANSMITTER  
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED  
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED  
DXS-62A  
REPEAT STEPS 2 & 3 FOR  
ADDITIONAL TRANSMITTERS  
(UP TO 16 TOTAL)  
PRESS CLEAR TO RETURN TO OPERATE MODE  
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED  
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED  
4
5
THE CONSOLE WILL RETURN TO OPERATE MODE  
AUTOMATICALLY AFTER 30 SECONDS  
THE CONSOLE WILL RETURN TO OPERATE  
MODE AUTOMATICALLY AFTER 3 MINUTES  
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER  
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED  
TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER.  
NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER  
WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED  
TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. TESTING TRANSMITTERS  
14. ERASING TRANSMITTERS  
PRESS TEST BUTTON  
• 4 BEEPS SOUND (TEST MODE)  
1
CAUTION: ALL TRANSMITTERS  
WILL BE ERASED!  
2
ACTIVATE EACH OF THE  
CONSOLE'S TRANSMITTERS,  
ONE AT A TIME  
PRESS AND HOLD TEST BUTTON FOR 5 SECONDS  
• 6 BEEPS SOUND (ALL TRANSMITTERS WERE ERASED)  
1
COUNT THE NUMBER OF BEEPS  
THAT THE CONSOLE SOUNDS  
WHEN THE TRANSMITTER  
IS ACTIVATED  
3
1-BEEP = TX OK  
2-BEEPS = TX HAD ALARM  
3-BEEPS = TX MISSED STATUS  
4-BEEPS = TX HAS LOW BATTERY  
NOTE: WITH THE MODEL VB-4B VOICE BOARD  
INSTALLED, THE CONSOLE WILL ANNOUNCE  
THE TRANSMITTER STATUS  
2
PRESS CLEAR TO RETURN TO OPERATE MODE  
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED  
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED  
4
PRESS CLEAR TO RETURN TO OPERATE MODE  
• 2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED  
• 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED  
THE CONSOLE WILL RETURN TO OPERATE MODE  
AUTOMATICALLY AFTER 3 MINUTES  
THE CONSOLE WILL RETURN TO OPERATE MODE  
AUTOMATICALLY AFTER 3 MINUTES  
15. LOCAL PROGRAMMING WITH RA-2400  
16. TELEPHONE CONNECTIONS  
LOCAL  
TELEPHONE  
JACK  
PERFORM THE STEPS DETAILED IN THE  
1
TELEPHONE  
RA-2400/PERS-2400 REFERENCE GUIDE (P/N 217163)  
TO SET UP THE RA-2400 PROGRAM  
TO LOCALLY PROGRAM  
THE CONSOLE, CONNECT  
THE MODEM'S LINE JACK  
TO THE CONSOLE'S LINE  
JACK  
2
3
LINE-TO-LINE  
PRESS TEST BUTTON  
MOMENTARILY  
• 4 BEEPS SOUND  
(TEST MODE)  
CONSOLE WITH  
REAR COVER  
INSTALLED  
NOTE: CONSOLE WILL EXIT TEST MODE  
AUTOMATICALLY AFTER 3 MINUTES  
OR BY PRESSING THE CLEAR BUTTON  
WHEN RA-2400 CONNECTION  
TIMER STARTS COUNTING DOWN,  
PRESS THE EMERGENCY BUTTON  
• 4 BEEPS SOUND  
4
5
(RA-2400 ANSWER)  
ROUTE CABLES UNDER  
STRAIN-RELIEF TABS  
CONNECT LOCAL  
TELEPHONE TO  
THIS JACK  
PERFORM PROGRAMMING IN  
THE RA-2400 SOFTWARE, THEN  
DISCONNECT FROM THE CONSOLE  
CONNECT TELEPHONE  
LINE TO THIS JACK  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
17. SYSTEM OPERATION  
18. ACTIVITY TIMER  
ENABLING THE ACTIVITY TIMER  
PRESS THE HOME BUTTON FOR  
5 SECONDS TO TURN THE  
ACTIVITY TIMER ON  
CONSOLE  
STANDING BY  
1
POWER LIGHT IS ON  
NOTE: THE ACTIVITY TIMER CAN  
BE ENABLED FOR 8, 12, OR  
24 HOURS, OR DISABLED BY  
PROGRAMMING  
OTHER LIGHTS ARE OFF  
NOTE: TO TURN THE ACTIVITY TIMER OFF,  
PRESS THE HOME BUTTON FOR FIVE SECONDS  
2
3
ACTIVITY TIMER RUNNING  
TIME RUNNING OUT  
- IN CASE OF EMERGENCY -  
THE HOME INDICATOR WILL BLINK &  
A SHORT BEEP SOUNDS EVERY  
10 SECONDS WHEN LESS THAN  
15 MINUTES OF TIME REMAIN  
THE HOME INDICATOR WILL LIGHT,  
SHOWING THAT THE ACTIVITY  
TIMER IS ENABLED  
PRESS AND  
- OR -  
ACTIVATE  
MOMENTIARLY  
HOLD  
EMERGENCY  
TRANSMITTER  
EMERGENCY  
BUTTON  
PRESS TRANSMITTER  
BUTTON FOR AT LEAST  
2 SECONDS  
SIREN SOUNDS  
UNTIL CLEAR BUTTON  
IS PRESSED,  
CONSOLE  
IN ALARM  
4
RESETING ACTIVITY TIMER  
THE SUBSCRIBER NEEDS TO  
PRESS THE HOME BUTTON OR  
TRIGGER AN ACTIVITY  
TRANSMITTER BEFORE THE  
TIMER EXPIRES TO PREVENT  
AN INACTIVITY REPORT  
CENTRAL STATION  
REPORT IS COMPLETE,  
OR SIREN TIME EXPIRES  
SENDING LIGHT  
FLASHES DURING  
COMMUNICATION  
PRESS CLEAR TO  
STOP SIREN  
(ADDS CANCEL TO  
ALARM REPORT IN  
PROGRESS)  
PRESSING THE HOME BUTTON  
RESTARTS THE TIMER  
19. AUDIO BOARD OPERATION  
20. SPEAKERPHONE OPERATION  
1
PROGRAM THE CONSOLE TO ENABLE SPEAKERPHONE MODE  
1
NOTE: SPEAKERPHONE MODE CAN ONLY BE USED ON INCOMING CALLS  
AND WILL NOT FUNCTION WHEN THE CONSOLE IS OPERATING FROM  
BACKUP BATTERY POWER. ATTEMPTING TO ANSWER WHILE THE CONSOLE  
IS ON BACKUP POWER WILL CAUSE AN EMERGENCY ALARM.  
WHILE THE TELEPHONE IS RINGING, ACTIVATING AN  
EMERGENCY TRANSMITTER OR PRESSING THE EMERGENCY  
2
2
BUTTON WILL SEIZE THE TELEPHONE LINE  
CENTRAL STATION OPERATOR:  
3
THE AUDIO BOARD WILL BEGIN 2-WAY FULL DUPLEX MODE  
FOR AUDIO COMMUNICATIONS  
3
WARNING: THE CONSOLE WILL NOT BE ABLE  
TO REPORT AN EMERGENCY WHILE THE  
SPEAKERPHONE MODE IS ACTIVE  
NOTE: TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE,  
PRESS EITHER THE EMERGENCY BUTTON OR THE BUTTON ON AN  
EMERGENCY TRANSMITTER TO END THE PHONE CALL AND THEN PRESS  
ONE OF THESE BUTTONS AGAIN TO REPORT THE EMERGENCY.  
THE AUDIO BOARD WILL END AUDIO COMMUNICATIONS  
WHEN EITHER:  
4
• THE EMERGENCY BUTTON IS PRESSED  
• ANY EMERGENCY TRANSMITTER IS ACTIVATED  
• THE AUTO-DISCONNECT TIMER RUNS OUT  
PRESSING ANY KEY OTHER THAN "9" WILL EXTEND THE AUDIO TIME  
90 MORE SECONDS  
NOTE: TO USE THE AUDIO MODES, THE MODEL VB-4B AUDIO MODULE  
MUST BE INSTALLED IN THE CONSOLE  
NOTE: TO USE THE SPEAKERPHONE MODE, THE MODEL VB-4B AUDIO  
MODULE MUST BE INSTALLED IN THE CONSOLE  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. SUPERVISORY CONDITIONS  
22. WIRELESS INSTALLATION TIPS  
TRANSMITTER LOW BATTERY TROUBLE  
WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE  
CONSOLE'S TROUBLE INDICATOR WILL BLINK SLOWLY.  
WALLBOARD AND  
WOOD STUDS  
CONSTRUCTION  
MATERIALS WILL  
TRANSMITTER SUPERVISORY TROUBLE  
AFFECT RADIO RANGE  
IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS  
TO REPORT STATUS IN A 24 HOUR PERIOD, THE CONSOLE'S  
TROUBLE INDICATOR WILL LIGHT.  
90% - 100%  
OF FULL POWER  
CONSOLE BACKUP BATTERY TROUBLE  
WHEN TROUBLE EXISTS,  
THE CONSOLE WILL BEEP EVERY  
HOUR UNTIL CLEARED:  
THE CONSOLE WILL TEST ITS BACKUP  
BATTERY EVERY 8 HOURS. IF THE BATTERY  
TESTS LOW, THE POWER INDICATOR WILL  
BLINK SLOWLY WHILE THE CONSOLE  
CHARGES THE BATTERY.  
CONCRETE WITH STEEL  
REINFORCEMENT OR  
METAL LATH AND PLASTER  
LIGHT CONCRETE  
OR BRICK  
2-BEEPS = CONSOLE LOW BATTERY  
3-BEEPS = TRANSMITTER SUPERVISORY  
4-BEEPS = TRANSMITTER LOW BATTERY  
65% - 95%  
OF FULL POWER  
10% - 70%  
OF FULL POWER  
THE CONSOLE WILL REPORT  
TROUBLE AND/OR 30-DAY STATUS  
TO THE CENTRAL STATION IF  
ENABLED IN THE COMMUNICATOR  
PROGRAMMING  
CENTRALLY LOCATE CONSOLE  
NOTE: THE CONSOLE WILL ANNOUNCE  
THE SUPERVISORY CONDITIONS WITH  
THE OPTIONAL MODEL VB-4B VOICE  
BOARD INSTALLED. THE VOICE CAN  
BE DISABLED THROUGH  
CONSOLE LOCATION WILL  
AFFECT RADIO RANGE  
RIGHT  
PROGRAMMING  
TRANSMITTERS AT THE  
OTHER END OF THE HOUSE  
MIGHT BE TOO FAR AWAY  
CLEARING TROUBLE INDICATIONS  
PRESS THE CLEAR BUTTON TO STOP TROUBLE  
INDICATORS AND SOUNDERS  
NOTE: THE TROUBLE CONDITION WILL LIKELY OCCUR AGAIN  
UNTIL THE PROBLEM IS FIXED  
WRONG!  
LINEAR LIMITED WARRANTY  
SPECIFICATIONS  
This Linear product is warranted against defects in material and workmanship for twelve  
(12) months.This warranty extends only to wholesale customers who buy direct from Linear  
or through Linear’s normal distribution channels. Linear does not warrant this product to  
consumers. Consumers should inquire from their selling dealer as to the nature of the  
dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC  
for consequential damages arising out of or in connection with use or performance  
of this product or other indirect damages with respect to loss of property, revenue, or  
profit, or cost of removal, installation, or reinstallation. All implied warranties, including  
implied warranties for merchantability and implied warranties for fitness, are valid only until  
the warranty expires. This Linear LLCWarranty is in lieu of all other warranties express  
or implied.  
CODING FORMATS  
DX CODE 24-BIT A1D PPM 1,048,567 CODES  
DXS CODE 24-BIT A1D PPM 1,048,567 CODES  
POWER REQUIREMENTS  
PRIMARY SUPPLY 16 VAC 1.25 AMP PLUG-IN TRANSFORMER  
BACKUP SUPPLY 12 VOLT 1.2 AMP/HOUR BATTERY  
NORMAL OPERATING CURRENT 80 mA  
ALARM OPERATING CURRENT 120 mA  
BACKUP OPERATION DURATION 32 HOURS MINIMUM  
BATTERY LIFE EXPECTED 3 YEARS  
BACKUP SUPPLY OPERATING CURRENT 32 mA  
RF CHARACTERISTICS  
All products returned for warranty service require a Return Product Authorization Number  
(RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other  
important details.  
RECEIVER TYPE DUAL-DIVERSITY SUPERHETERODYNE  
RF SENSITIVITY -100 dBm TYPICAL  
RADIO FREQUENCY 315 Mhz  
MAXIMUM RANGE 400 FEET LINE-OF-SIGHT, OPEN RANGE  
UL LISTED FOR 150’  
IMPORTANT WIRELESS INFORMATION  
Linear radio controls provide a reliable communications link and fill an important need in  
portable wireless signaling. However, there are some limitations which must be observed.  
COMMUNICATOR  
COMMUNICATOR FORMATS 4 BY 2 (GENERAL OR POINT-TO-POINT),  
ADEMCO CONTACT ID  
For U.S. installations only: The radios are required to comply with FCC Rules and  
Regulations as Part 15 devices. As such, they have limited transmitter power and  
therefore limited range.  
UL TESTED WITH SURGARD SGMLRG-DG  
CENTRAL STATION RECEIVER  
DIALING TONE OR PULSE  
DIALING DELAY 0 OR 15 SECONDS  
A receiver cannot respond to more than one transmitted signal at a time and may be  
blocked by radio signals that occur on or near their operating frequencies, regardless of  
code settings.  
REMOTE ACCESS PASSWORD 6 DIGITS  
NOTE:THE INSTALLER MUST  
ACCOUNT NUMBER LENGTH 4 DIGITS  
PRIMARY TELEPHONE NUMBER 20 DIGITS  
SECONDARY TELEPHONE NUMBER 20 DIGITS  
SUPERVISORY TELEPHONE NUMBER 20 DIGITS  
VERIFY COMPATIBILITY  
BETWEEN THE PERS-2400B AND  
THE UL LISTED DIGITAL ALARM  
COMMUNICATOR RECEIVER  
Changes or modifications to the device may void FCC compliance.  
Infrequently used radio links should be tested regularly to protect against undetected  
interference or fault.  
CONSOLE STATUS REPORT OPTIONAL 1, 7 OR 30 DAY REPORT  
A general knowledge of radio and its vagaries should be gained prior to acting as a  
wholesale distributor or dealer, and these facts should be communicated to the ultimate  
users.  
CONSOLE  
OPERATING TEMPERATURE 32°-100° F (0-50° C)  
EMERGENCY ALARM DURATION 1-30 MINUTES  
ACTIVITY TIMER PERIOD 8, 12, OR 24 HOURS  
AUDIO LISTEN-ONLY, 2-WAY MANUAL, 2-WAY DUPLEX,  
SPEAKERPHONE  
RELAY OUTPUT N.O. @ 24 VOLT AC/DC 1 AMP  
MAXIMUM, NEC CLASS II CIRCUITRY  
Copyright © 2012 Linear LLC  
228279 BX1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenovo Computer Monitor 2448HB6 User Manual
LG Electronics CRT Television 32LY750H User Manual
Lincoln Electric Steamer MODEL 4000 SERIES User Manual
Lochinvar Boiler 151 286 User Manual
Magnavox Cassette Player AQ 6570 User Manual
Martin Audio Stereo Amplifier MA68Q User Manual
Master Bilt Refrigerator BLG 27HD User Manual
M Audio Indoor Furnishings QS_M80010QS User Manual
M Audio Personal Computer AV 30 User Manual
Memorex Stereo System MX5510 User Manual