INTRODUCTION
FEATURES
The Model SXR-64A is a 64-channel, 12-zone, supervised wireless receiver/
annunciator designed for use in residential or commercial security systems. Housed
in a rugged metal enclosure, the SXR-64A connects to a hardwired alarm control
panel adding wireless capability to the panel.
SXR-64A
✶ 64 Programmable Transmitter Channels
✶ 8 Alarm Zones
✶ 4 Supervisory Zones
Supervised Wireless Receiver
and Zone Expander
The SXR-64A receives signals from a variety of security transmitters then processes,
displays and transfers the signal to the hardwired alarm control panel. Six unique
conditions for each transmitter channel can be shown on the unit’s display. Conditions
such as “Open Portal”, “Transmitter Low Battery”, “Transmitter Tamper” and “First
Alarm In” show the status of each transmitter in the system. Valuable features such
as Alarm Memory and Transmitter Status allow for quick system diagnosis and
troubleshooting.
✶ Rugged Metal Enclosure
✶ Six Condition Displays for Each Transmitter
✶ Alarm Memory with First-Alarm-In
✶ Automatic Supervised Operation
✶ Transmitter Contact State Monitoring
✶ Transmitter Tamper Monitoring
✶ Transmitter Low Battery Monitoring
✶ Transmitter Status Report Monitoring
✶ Easy Installer Programming Interface
✶ High-gain Superheterodyne Receiver
✶ Receiver Automatic Gain Control
✶ Antenna Connector
The receiver’s eight alarm zones and four supervisory zones provide a flexible
interface to the alarm control panel. Any or all of the zones can be used. All of the
solid state zone outputs can be either normally open or normally closed electrical
configuration and can switch up to 100 mA @ 24 VDC.
An easy programming interface using four pushbuttons lets the installer quickly setup
the system. The UP, DOWN, ADVANCE and MEMORY buttons are located inside the
receiver case and are used for transmitter and system programming.
An on-board, high-gain, superheterodyne radio receiver gives the SXR-64A excellent
reception. The MODE indicator shows RF activity. The local whip antenna (supplied)
or remote external antenna (Model EXA-1000) connects to the receiver through a
standard type “F” connector.
The SXR-64A decodes Linear’s SX, S1, and MegaCode™ format transmitters. The
SXR-64A can be used as a direct replacement for Linear’s SS-32, SSR-32, & SXR-64
receivers with an installation bonus of being able to use up to 64 transmitters in the
system.
Installation Instructions
✶ Decodes 303.875 MHz SX, S1, & MegaCode™ Format Transmitters
✶ Optional Display Blanking while Armed
✶ RF Activity Indicator
Power for the SXR-64A is provided from the alarm control panel. To control the alarm
memory, reset tamper and status alert conditions, an armed input on the receiver
connects to an armed output from the control panel.
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
✶ Positive or Negative Armed Input
SYSTEM OVERVIEW
CONDITION DISPLAYS
COMPONENT LOCATIONS
TYPICAL TRANSMITTERS
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
TRANSMITTER DISPLAY
SHOWS THE TRANSMITTER'S
TX-91
TX-92
TX-94
T-90D
TMD-90
TSD-90A
ANTENNA CONNECTOR
TYPE "F" ANTENNA CONNECTOR FOR
CONNECTION TO LOCAL OR REMOTE
ANTENNA THROUGH RG-59 COAX
CHANNEL NUMBER AND IS USED
DURING PROGRAMMING
OPEN PORTAL
CONDITION DISPLAY
ALL TRANSMITTERS WILL CAUSE THIS CONDITION WHEN AN ALARM SIGNAL IS
SENT. THE CONDITION WILL REMAIN UNTIL A RESTORE SIGNAL IS SENT, UNLESS
THE TRANSMITTER IS SET AS "AUTO RESTORE". THE CHANNEL'S ZONE OUTPUT
WILL BE FAULTED WHEN THIS CONDITION IS DISPLAYED.
SHOWS THE TRANSMITTER'S
CONDITION AND IS USED DURING
PROGRAMMING
MODE LIGHT
LIGHTS WHEN UNIT IS
IN PROGRAM MODE,
FLASHES WHEN RF IS
RECEIVED IN RUN
MODE
FIRST ALARM IN
WHEN THE PANEL IS ARMED, THE FIRST ALARM SIGNAL SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
ST-23A
LMT-1/303
MPX/303
MEMORY LIGHT
LIGHTS DURING PROGRAM
MODE TO SHOW WHEN A
TRANSMITTER HAS BEEN
ENTERED OR AN OPTION
HAS BEEN SELECTED,
LIGHTS DURING RUN MODE
WHEN SYSTEM IS ARMED,
BLINKS DURING EXIT DELAY
ADDITIONAL ALARMS IN
WHEN THE PANEL IS ARMED, ADDITIONAL ALARM SIGNALS SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
TEST POINTS
AUDIO TEST
POINTS FOR
LISTENING TO
RADIO INPUT
WITH BUTTSET
UP TO 64 TRANSMITTERS
CAN BE USED
TRANSMITTER LOW BATTERY
ANY TRANSMITTER THAT CAN SEND A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION WHEN ITS BATTERY IS LOW. DISPLAY WILL REMAIN UNTIL A SIGNAL
FROM THE SAME TRANSMITTER WITH A GOOD BATTERY IS SENT.
MEMORY BUTTON
USED DURING PROGRAMMING
TO SELECT OPTIONS AND
ENTER TRANSMITTERS
TRANSMITTER TAMPER
ANY TRANSMITTER THAT CAN SEND A TAMPER SIGNAL WILL CAUSE THIS
CONDITION WHEN IT IS TAMPERED. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
UP & DOWN BUTTONS
PRESS EITHER TO ENTER
PROGRAM MODE, UP
INCREASES AND DOWN
DECREASES VALUE DISPLAYED
PRESS TOGETHER TO EXIT
PROGRAM MODE
TERMINAL BLOCK
CONNECTIONS FOR ZONE AND
SUPERVISORY OUTPUTS,
TRANSMITTER STATUS ALERT
IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS FROM A TRANSMITTER
THAT IS SET AS SUPERVISED, THIS CONDITION WILL BE DISPLAYED. THE RECEIVER
CAN BE SET FOR TWO OR EIGHT HOURS OF MISSING STATUS TRANSMISSIONS
BEFORE THE CONDITION OCCURS. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
POWER AND ARMED INPUTS
ADVANCE BUTTON
USED DURING PROGRAMMING
TO CHANGE ZONE NUMBERS
AND SELECT FUNCTIONS
SXR-64A RECEIVER
ALARM CONTROL PANEL
WIRING KNOCKOUTS
FOR WIRING CONDUIT
CONNECTION
INSTALLATION TIPS
MOUNTING UNIT
ANTENNA INSTALLATION
90% - 100%
65% - 95%
10% - 70%
OF FULL POWER
OF FULL POWER
OF FULL POWER
USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER
7"
CONSTRUCTION
MATERIALS WILL
EFFECT RADIO RANGE
MOUNTING
PATTERN
5"
5"
WALLBOARD AND
WOOD STUDS
CONCRETE WITH STEEL
REINFORCEMENT OR
LIGHT CONCRETE
OR BRICK
USE LOCAL
METAL LATH AND PLASTER
WHIP ANTENNA
(SUPPLIED)
RECEIVER (ANTENNA)
LOCATION EFFECTS
RADIO RANGE
- OR -
RCVR
RCVR
BASEMENT
WRONG!
USE THE
BASEMENT
MODEL EXA-1000
REMOTE ANTENNA
(OPTIONAL)
RIGHT
MOUNT RECEIVER OR ANTENNA AS HIGH ABOVE
EARTH LEVEL AS POSSIBLE
LOCATING A RECEIVER OR ANTENNA BELOW
EARTH LEVEL WILL IMPAIR RANGE
ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS
RIGHT
WRONG!
CENTRALLY LOCATE RECEIVER
OR ANTENNA
TRANSMITTERS AT THE OTHER END OF
HOUSE MIGHT BE TOO FAR AWAY
TX
Less
than
3 ft.
DOOR
DOOR
above
slab
Wall
TRANSMITTER
MOUNTING WILL
EFFECT RADIO
RANGE
CONNECT ANTENNA
TX
Min.
3 ft.
Concrete
Large
slab
Concrete
slab
floor
COAX DIRECTLY OR
USE UP TO 25 FEET
OF RG-59 COAX AS
AN EXTENSION
metal
appliance
(refrig.)
floor
TX
RIGHT
WRONG!
WRONG!
TERMINAL BLOCK DETAILS
TYPICAL CONTROL PANEL CONNECTION
S1 FORMAT TRANSMITTER DETAILS
SXR-64A TERMINALS
EACH S1 FORMAT
SXR-64A TERMINALS
SET CHANNEL AND
SYSTEM SWITCH TO
ANY UNIQUE CODE
TRANSMITTER MUST
BE SET TO A DIFFERENT
CODE
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
9 10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
1
2
3
4
5
6
7
8
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST
ARM
OUTPUTS PROGRAMMED
FOR NORMALLY OPEN
CHANNEL
SWITCH
END-OF-LINE
RESISTORS
MODEL ST-1
STATUS
JUMPER
ZONE OUTPUTS
MODEL ST
FOR CONNECTION TO ALARM ZONE INPUTS ON THE ALARM
CONTROL PANEL. ZONE OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL PROGRAMMED FOR THAT ZONE IS
IN THE FAULTED (ALARM/OPEN) CONDITION ("O" DISPLAYED
ON THE CONDITION DISPLAY).
RESTORE
JUMPER
SYSTEM
SWITCH
CUT ST-1 JUMPERS
TO ENABLE STATUS
& RESTORE SIGNALS
SYSTEM
SWITCH
CHANNEL
SWITCH
LOW BATTERY OUTPUT
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "L" ON THE
CONDITION DISPLAY.
ST-1 & 50S40A NOTE: SET SXR-64A TRANSMITTER OPTION "A"
TO "ON" FOR THE CHANNEL THE TRANSMITTER IS PROGRAMMED TO.
OTHERWISE, THE LONG ALARM AND RESTORE
STATUS OUTPUT
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "S" ON THE
CONDITION DISPLAY.
ALARM CONTROL PANEL
ZONE 8
TRANSMISSIONS WILL CAUSE A DOUBLE ZONE CLOSURE
MODEL ST-23A
COMMON
SYSTEM
SWITCH
ST-23A NOTE: SET
SYSTEM SWITCH #1
TO OFF
TAMPER OUTPUT
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS A "P" ON THE CONDITION
DISPLAY OR WHEN ANY PROGRAMMING BUTTON IS
PRESSED WHILE THE SYSTEM IS ARMED.
ZONE 7
AUXILIARY
POWER
MODEL 50S40A
ZONE 6
COMMON
ZONE 5
ZONE 4
COMMON
ZONE 3
ZONE 2
COMMON
ZONE 1
CHANNEL
SWITCH
TEST OUTPUT
FOR CONNECTION TO A TEST ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER THAT CAN SEND A TEST SIGNAL HAS ITS
POWER INPUT
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S AUXILIARY
POWER OUTPUT. POWER INPUT
CAN BE FROM 11-16 VDC ONLY
TEST BUTTON PRESSED.
ARMED
OUTPUT
NOTES:
8
1. ALL COM TERMINALS ARE COMMON GROUND
AND CONNECTED TOGETHER.
ARMED INPUT
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S ARMED OUTPUT.
THE ARMED INPUT CAN BE SET FOR
ARMED-POSITIVE OR
2. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH OUTPUT
RETURNS TO ANY COM TERMINAL.
SYSTEM
SWITCH
WHEN UPGRADING AN SS-32,
SSR-32, OR SXR-64 INSTALLATION,
THE TRANSMITTER SWITCH
ARMED-NEGATIVE POLARITY.
CHANNEL
SWITCH
3. EACH OUTPUT CAN SWITCH UP TO 100 mA @ 24 VDC
MAXIMUM.
SETTINGS CAN REMAIN THE SAME