Linear Home Security System DXS 54 User Manual

PRODUCT DESCRIPTION  
The DXS-54 is a battery powered passive infrared motion detector with The unit is powered from a 9-Volt alkaline battery. The batterys life  
a built-in transmitter designed for use with Linear’s DXS and DX format can be up to three years depending on the areas traffic. When the  
receivers. This transmitter can be used in a variety of motion detection battery gets low, the test indicator will flash and a low battery signal  
applications. When the passive infrared sensor detects motion in its will be sent to the receiver when the detector senses motion.  
DXS-54  
DXS  
FORMAT  
By  
field of view, the transmitter sends a digitally coded wireless signal to  
its companion receiver.  
Approximately every hour, the DXS-54 will send a status transmission  
to the receiver. The hourly signal updates the receiver to the  
SUPERVISED  
WIRELESS  
MOTION  
The digital DXS code format features over a million possible codes. transmitters condition. By monitoring status transmissions, the  
The DXS transmitters are precoded at the factory to unique codes, so receiver can determine if a transmitter has a low battery or has been  
no field coding is required. The DXS-54 can send three different removed from the system. DXS format receivers can monitor status  
signals: alarm, low battery and status.  
signals, DX format receivers cannot.  
For versatility, any transmitter can be programmed into any receiver To conserve battery life, during normal operation, the detector can  
channel. Receivers must be programmed to the transmitters code trigger the transmitter a maximum of once every four minutes.  
DETECTOR  
before system testing and operation. Refer to the receivers  
For setup and testing, pressing the detectors test button places the  
instructions for details on programming.  
unit in walk test mode for four minutes. The installer can walk in front  
Installation Instructions  
In a typical installation, the motion detector is mounted indoors in a of the unit while viewing the red test indicator through the detectors  
corner or on a wall between six and eight feet high. The sensor will lens to determine the detection area.  
monitor the infrared level in its detection pattern. If the level increases  
or decreases rapidly (as when a person or animal moves through the  
area) the transmitter triggers, sending an alarm signal to the receiver.  
In walk test, an alarm signal is sent each time the walk test indicator  
lights. During normal operation, the detector requires a pulse count”  
of three events in eight seconds before sending an alarm transmission.  
(760) 438-7000 FAX (760) 438-7043  
USA & Canada (800) 421-1587 & (800) 392-0123  
Toll Free FAX (800) 468-1340  
DXS-54 FEATURES  
DETECTION PATTERN  
TYPICAL INSTALLATION  
DON'T POINT AT HEAT SOURCES  
(HEATERS, ETC.), WINDOWS, OTHER  
MOTION DETECTORS OR DOOR/WINDOW  
TRANSMITTERS  
MOTION  
DETECTOR  
IN CORNER  
30 FEET  
TEST INDICATOR  
BEHIND LENS  
(BLINKS DURING  
WALK TEST, FLASHES  
WHEN BATTERY IS LOW  
DURING MOTION)  
MOTION  
DETECTOR  
LENS  
MOTION  
DETECTOR  
DETECTION  
AREA  
FRONT  
ROOM  
(FOR INDOOR  
USE ONLY)  
TOP  
VIEW  
WALK  
TEST  
BUTTON  
BEDROOM  
MOUNT  
DETECTOR  
SO THAT  
BATH  
OPERATING  
TEMPERATURE  
RANGE:  
+32° TO +120° F  
(0° TO +49° C)  
INTRUDER  
WILL CROSS  
BEAMS  
KITCHEN  
SIDE  
VIEW  
6-8 FEET  
CASE  
LOCKING  
SCREW  
(ON BOTTOM)  
30 FEET  
CONNECTING BATTERY  
MOUNTING DETECTOR BASE  
WALK TEST  
MOUNTING THE DETECTOR  
IN A CORNER IS PREFERRED  
REMOVE  
SCREW  
AND OPEN  
CASE  
AFTER MOUNTING, SNAP  
DETECTOR ONTO BASE  
AND REPLACE CASE SCREW  
USE SIDE HOLES  
FOR CORNER  
MOUNTING  
PUSH  
WALK  
USE CENTER  
HOLES FOR  
WALL  
WALK IN FRONT OF UNIT  
TEST  
WHILE WATCHING RED LIGHT  
BUTTON  
MOUNTING  
UNIT WILL STAY IN  
WALK TEST MODE  
FOR 4 MINUTES AFTER  
PRESSING WALK TEST  
BUTTON  
CONNECT 9-VOLT ALKALINE  
BATTERY TO BATTERY CLIP  
(PLUS SIDE UP)  
PUNCH OUT REQUIRED HOLES  
FOR SCREW MOUNTING  
MOUNT  
DETECTOR  
6-8 FEET  
HIGH  
NOTE:  
THE DETECTOR CAN  
BE MOUNTED WITH  
DOUBLE STICK TAPE,  
BUT IS NOT ALLOWED  
IN UL INSTALLATIONS  
NOTE: BE SURE TO  
REPLACE THE CASE  
SCREW AFTER CLOSING  
THE CASE  
VERIFY THAT DETECTION  
PATTERN COVERS DESIRED  
AREA  
NOTE: AFTER INITIAL SETUP  
WALK TEST UNIT ANNUALLY  
PROGRAM RECEIVER AND TEST  
CHANGING BATTERY  
LINEAR LIMITED WARRANTY  
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The  
Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers  
who buy direct from Linear or through Linears normal distribution channels. Linear does not warrant  
this product to consumers. Consumers should inquire from their selling dealer as to the nature of the  
dealers warranty, if any. There are no obligations or liabilities on the part of Linear corporation for  
consequential damages arising out of or in connection with use or performance of this product or  
other indirect damages with respect to loss of property, revenue, or profit, or cost of removal,  
installation, or reinstallation. All implied warranties, including implied warranties for merchantability and  
implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This  
Linear Corporation Warranty is in lieu of all other warranties express or implied.  
FOR PROGRAMMING,  
REFER TO THE RECEIVER'S  
INSTRUCTIONS  
WHEN THE DETECTOR  
HAS A LOW BATTERY:  
REMOVE  
AFTER PROGRAMMING RECEIVER  
TO THE TRANSMITTER'S CODE  
TEST THE SYSTEM  
SCREW  
AND OPEN  
CASE  
For warranty service on Linear equipment return product, at senders expense to:  
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact  
Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.  
STAYING CLEAR, WAIT AT LEAST  
FIVE MINUTES BEFORE WALKING  
INTO THE DETECTION AREA  
IMPORTANT !!!  
Linear radio controls provide a reliable communications link and fill an important need in portable wireless  
signalling. However, there are some limitations which must be observed.  
REPLACE THE BATTERY WITH  
A FRESH 9-VOLT ALKALINE  
OR LITHIUM BATTERY  
(PLUS SIDE UP)  
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as  
Part 15 devices. As such, they have limited transmitter power and therefore limited range.  
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by  
radio signals that occur on or near their operating frequencies, regardless of code settings.  
Changes or modifications to the device may void FCC compliance.  
USE ALKALINE  
OR LITHIUM  
BATTERIES ONLY  
Infrequently used radio links should be tested regularly to protect against undetected interference  
or fault.  
WALK ACROSS THE DETECTION  
PATTERN AND VERIFY THAT  
THE RECEIVER ACTIVATES  
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale  
distributor or dealer, and these facts should be communicated to the ultimate users.  
SNAP DETECTOR ONTO BASE  
AND REPLACE CASE SCREW  
WHEN FINISHED  
Copyright © 1997 Linear Corporation  
209509 B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kustom Stereo Amplifier WAV 210 User Manual
Lexmark All in One Printer 750e MFP User Manual
Lightolier Indoor Furnishings 1104F18ESR User Manual
Lincoln Convection Oven 1421 000 E User Manual
Lowrance electronic Radar Detector RIM 300 User Manual
Mattel PDAs Smartphones R7326 User Manual
Melissa Coffeemaker 245 022 User Manual
MGE UPS Systems Power Supply EX10 User Manual
Micro Star Computer Computer Hardware G31M User Manual
Midland Radio Weather Radio HH54 User Manual