PRODUCT DESCRIPTION
The DXS-54 is a battery powered passive infrared motion detector with The unit is powered from a 9-Volt alkaline battery. The battery’s life
a built-in transmitter designed for use with Linear’s DXS and DX format can be up to three years depending on the area’s traffic. When the
receivers. This transmitter can be used in a variety of motion detection battery gets low, the test indicator will flash and a low battery signal
applications. When the passive infrared sensor detects motion in its will be sent to the receiver when the detector senses motion.
DXS-54
DXS
FORMAT
By
field of view, the transmitter sends a digitally coded wireless signal to
its companion receiver.
Approximately every hour, the DXS-54 will send a status transmission
to the receiver. The hourly signal updates the receiver to the
SUPERVISED
WIRELESS
MOTION
The digital DXS code format features over a million possible codes. transmitter’s condition. By monitoring status transmissions, the
The DXS transmitters are precoded at the factory to unique codes, so receiver can determine if a transmitter has a low battery or has been
no field coding is required. The DXS-54 can send three different removed from the system. DXS format receivers can monitor status
signals: alarm, low battery and status.
signals, DX format receivers cannot.
For versatility, any transmitter can be programmed into any receiver To conserve battery life, during normal operation, the detector can
channel. Receivers must be programmed to the transmitter’s code trigger the transmitter a maximum of once every four minutes.
DETECTOR
before system testing and operation. Refer to the receiver’s
For setup and testing, pressing the detector’s test button places the
instructions for details on programming.
unit in walk test mode for four minutes. The installer can walk in front
Installation Instructions
In a typical installation, the motion detector is mounted indoors in a of the unit while viewing the red test indicator through the detector’s
corner or on a wall between six and eight feet high. The sensor will lens to determine the detection area.
monitor the infrared level in its detection pattern. If the level increases
or decreases rapidly (as when a person or animal moves through the
area) the transmitter triggers, sending an alarm signal to the receiver.
In walk test, an alarm signal is sent each time the walk test indicator
lights. During normal operation, the detector requires a “pulse count”
of three events in eight seconds before sending an alarm transmission.
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
DXS-54 FEATURES
DETECTION PATTERN
TYPICAL INSTALLATION
DON'T POINT AT HEAT SOURCES
(HEATERS, ETC.), WINDOWS, OTHER
MOTION DETECTORS OR DOOR/WINDOW
TRANSMITTERS
MOTION
DETECTOR
IN CORNER
30 FEET
TEST INDICATOR
BEHIND LENS
(BLINKS DURING
WALK TEST, FLASHES
WHEN BATTERY IS LOW
DURING MOTION)
MOTION
DETECTOR
LENS
MOTION
DETECTOR
DETECTION
AREA
FRONT
ROOM
(FOR INDOOR
USE ONLY)
TOP
VIEW
WALK
TEST
BUTTON
BEDROOM
MOUNT
DETECTOR
SO THAT
BATH
OPERATING
TEMPERATURE
RANGE:
+32° TO +120° F
(0° TO +49° C)
INTRUDER
WILL CROSS
BEAMS
KITCHEN
SIDE
VIEW
6-8 FEET
CASE
LOCKING
SCREW
(ON BOTTOM)
30 FEET
CONNECTING BATTERY
MOUNTING DETECTOR BASE
WALK TEST
MOUNTING THE DETECTOR
IN A CORNER IS PREFERRED
REMOVE
SCREW
AND OPEN
CASE
AFTER MOUNTING, SNAP
DETECTOR ONTO BASE
AND REPLACE CASE SCREW
USE SIDE HOLES
FOR CORNER
MOUNTING
PUSH
WALK
USE CENTER
HOLES FOR
WALL
WALK IN FRONT OF UNIT
TEST
WHILE WATCHING RED LIGHT
BUTTON
MOUNTING
UNIT WILL STAY IN
WALK TEST MODE
FOR 4 MINUTES AFTER
PRESSING WALK TEST
BUTTON
CONNECT 9-VOLT ALKALINE
BATTERY TO BATTERY CLIP
(PLUS SIDE UP)
PUNCH OUT REQUIRED HOLES
FOR SCREW MOUNTING
MOUNT
DETECTOR
6-8 FEET
HIGH
NOTE:
THE DETECTOR CAN
BE MOUNTED WITH
DOUBLE STICK TAPE,
BUT IS NOT ALLOWED
IN UL INSTALLATIONS
NOTE: BE SURE TO
REPLACE THE CASE
SCREW AFTER CLOSING
THE CASE
VERIFY THAT DETECTION
PATTERN COVERS DESIRED
AREA
NOTE: AFTER INITIAL SETUP
WALK TEST UNIT ANNUALLY
PROGRAM RECEIVER AND TEST
CHANGING BATTERY
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The
Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers
who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant
this product to consumers. Consumers should inquire from their selling dealer as to the nature of the
dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear corporation for
consequential damages arising out of or in connection with use or performance of this product or
other indirect damages with respect to loss of property, revenue, or profit, or cost of removal,
installation, or reinstallation. All implied warranties, including implied warranties for merchantability and
implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This
Linear Corporation Warranty is in lieu of all other warranties express or implied.
FOR PROGRAMMING,
REFER TO THE RECEIVER'S
INSTRUCTIONS
WHEN THE DETECTOR
HAS A LOW BATTERY:
REMOVE
AFTER PROGRAMMING RECEIVER
TO THE TRANSMITTER'S CODE
TEST THE SYSTEM
SCREW
AND OPEN
CASE
For warranty service on Linear equipment return product, at sender’s expense to:
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact
Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
STAYING CLEAR, WAIT AT LEAST
FIVE MINUTES BEFORE WALKING
INTO THE DETECTION AREA
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless
signalling. However, there are some limitations which must be observed.
REPLACE THE BATTERY WITH
A FRESH 9-VOLT ALKALINE
OR LITHIUM BATTERY
(PLUS SIDE UP)
✶
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as
Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by
radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
✶
✶
✶
USE ALKALINE
OR LITHIUM
BATTERIES ONLY
Infrequently used radio links should be tested regularly to protect against undetected interference
or fault.
WALK ACROSS THE DETECTION
PATTERN AND VERIFY THAT
THE RECEIVER ACTIVATES
✶
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
SNAP DETECTOR ONTO BASE
AND REPLACE CASE SCREW
WHEN FINISHED
Copyright © 1997 Linear Corporation
209509 B