PRODUCT DESCRIPTION
REMOVE MOUNTING PLATE
The DXS-72/EC is a photoelectric smoke alarm with a built-in
transmitter designed for use with Linear’s DXS and DX Format
receivers. When smoke is detected, the alarm sounds a loud local
alarm. Twenty seconds after the local alarm sounds, the built-in
transmitter sends a digitally coded wireless signal to its companion
receiver. The wireless signal will be repeated every 20 seconds as
long as smoke is still present.
MATCH UP
ALIGNMENT
TABS
DXS-72/EC
DXS
FORMAT
By
WIRELESS
PHOTOELECTRIC
SMOKE
The digital DXS code format features over a million possible codes.
The DXS transmitters are precoded at the factory to unique codes,
so no field coding is required. The DXS-72/EC can send three
different codes: alarm, test and low battery status.
ALARM
For versatility, any transmitter can be programmed into any receiver
channel. Receivers must be programmed to the transmitter’s
code before system testing and operation. Refer to the receiver’s
instructions for details on programming.
Installation
Instructions
The unit is powered by two 9-volt alkaline or lithium batteries. These
batteries are supplied with the transmitter and can power the unit
for up to two years. Every hour, the DXS-72/EC will send a status
transmission to the receiver. The hourly signal updates the receiver
to the transmitter’s condition. By monitoring status transmissions, the
receiver can determine if a transmitter has a low battery or has been
removed from the system. If the battery voltage drops below a preset
level the alarm will sound low battery beeps and a low battery signal
will be sent to the receiver with status reports (some receivers can
report low battery status, others cannot).
TWIST SMOKE
ALARM CLOCKWISE
TO LOCK TO MOUNTING
PLATE
(760) 438-7000 • FAX (760) 438-7043
ꢀ
NOTE: After replacing batteries, press transmitter test button
to reset “low battery circuit”.
DXS-72/EC FEATURES
INSTALL BATTERIES
CHOOSE ALARM LOCATION
PRESS TRANSMITTER TEST BUTTON
AFTER INSTALLING BATTERIES
TO RESET LOW BATTERY CIRCUIT
READ THE STANDARD FOR SMOKE ALARM
LOCATION ON THE BACK OF THESE INSTRUCTIONS
TRANSMIT LED
TRANSMITTER
TEST BUTTON
TRANSMITTER
BOARD
DETERMINE THE PROPER LOCATION FOR THE ALARM
BED
ROOM
BED
ROOM
HALL
LIVING
ROOM
RECREATION ROOM
CONNECT AND
INSTALL TWO
9-VOLT BATTERIES
BASEMENT
Indicates required smoke alarm
Indicates optional smoke alarm
if door is not provided between
Living and Recreation Rooms
9-VOLT BATTERY TYPES:
EVEREADY 216, 522, OR 1222
DURACELL MN1604
BATTERY
HOLDING
CUPS
GOLD PEAK 1604P, 1604S
ULTRALIFE LITHIUM U9VL
INSTALL MOUNTING PLATE
PROGRAM RECEIVER
MOUNT ALARM ON PLATE
MATCH UP
ALIGNMENT
TABS
REFER TO RECEIVER'S INSTRUCTIONS
TO PREPARE RECEIVER TO ACCEPT THE
TRANSMITTER'S CODE
SCREW
ANCHORS
FOR WALLBOARD
PRESS TRANSMITTER
TEST BUTTON
TO SEND SIGNAL
OR
PLASTIC
SINGLE-GANG
ELECTRICAL
BOX
TWIST SMOKE
ALARM CLOCKWISE
TO LOCK TO MOUNTING
PLATE