QUICK INSTALLATION  
Power off all your computers and connect them to the LIGHT GREEN ports on  
the rear of the LINDY CPU Switch Smart. LINDY 3-in-1 keyboard/video/mouse  
combination cables are recommended for convenience. Suitable individual  
standard keyboard, video and mouse cables are also widely available.  
Connect your keyboard, monitor and mouse to the DARK GREEN port on the  
rear of the LINDY CPU Switch Smart.  
OPERATION GUIDE SUMMARY  
The LINDY CPU Switch Smart’s default configuration is suitable for most  
systems.  
A computer may be selected using the front panel key, a three button mouse or a  
keyboard hotkey combination. To select a computer using the mouse press and  
release the left or right hand buttons whilst holding down the central mouse  
button. To select a computer using the keyboard hotkeys hold down the CTRL  
and ALT keys, press and release the required port key (e.g. 1) and then release  
the CTRL and ALT keys.  
Safety information  
For use in dry, oil free indoor environments only.  
Do not attempt to service the LINDY CPU Switch Smart yourself.  
Follow all warnings and instructions marked on the LINDY CPU Switch Smart, its  
optional power adapter and its accessories.  
Warning - live parts contained within optional power adapter.  
No user serviceable parts within optional power adapter - do not dismantle.  
Replace the optional power adapter with a manufacturer approved type only.  
If you use a power extension cord with the LINDY CPU Switch Smart, make sure the  
total ampere rating of the devices plugged into the extension cord does not exceed the  
cords ampere rating. Also, make sure that the total ampere rating of all the devices  
plugged into the wall outlet does not exceed the wall outlets ampere rating.  
LINDY CPU Switch Smart  
ENGLISH  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPEZIELLE EIGENSCHAFTEN  
Der LINDY CPU Switch SMART ist Flash-uprgradable. Die Firmware ist damit an  
zukünftige neue Hardware prinzipiell anpassbar.  
Der LINDY CPU Switch kann kaskadiert werden.  
Der LINDY CPU Switch SMART hat ein robustes Metallgehäuse für hohe  
Stabilität und optimale EMV Abschirmung.  
Der LINDY CPU Switch SMART unterstützt sowohl Desktop, Tower als auch  
Notebook PCs, RS6000, DEC Alpha und Silicon Graphics Workstations.  
INSTALLATION  
Schalten Sie alle Ihre Computer aus und schließen Sie sie an die HELLGRÜN  
markierten Ports auf der Rückseite des LINDY CPU Switch SMART an. Wir  
empfehlen der Übersichtlichkeit halber die Verwendung der LINDY 3-in-1-  
Tastatur/Monitor/Mauskabel. Es können jedoch auch geeignete einzelne LINDY  
Standardkabel verwendet werden.  
Schließen Sie Ihre Tastatur, Ihren Monitor und Ihre PS/2-Maus an die  
DUNKELGRÜN markierten Ports auf der Rückseite des LINDY CPU Switch  
SMART an.  
Die Vorgabeeinstellungen (Lieferzustand) des LINDY CPU Switch SMART sind  
für die meisten Installationen geeignet (Änderungen siehe Ausführliches  
englisches Manual).  
SICHERHEITSHINWEISE  
Nur für den Gebrauch innerhalb von trockenen, ölfreien Räumen vorgesehen.  
Die Wartung des LINDY CPU Switch SMART darf nur ausschließlich von dazu  
qualifiziertem Fachpersonal vorgenommen werden.  
Sämtliche Warnhinweise und Anweisungen auf dem LINDY CPU Switch SMART,  
seinem optionalen Netzteil und Zubehörteilen sind zu beachten und zu befolgen.  
Warnung im Netzteil sind unter Spannung stehende Teile enthalten. Das  
Netzteil darf nicht geöffnet werden und soll bei Defekt nur durch einen vom  
Hersteller zugelassenen Typ ersetzt werden.  
LINDY CPU Switch Smart  
GERMAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E
Guía rápida de instalación y funcionamiento  
INSTALACIÓN RÁPIDA  
Desconecte todos los ordenadores y conéctelos a los puertos VERDE CLARO en la  
parte posterior del LINDY CPU Switch Smart. Para mayor comodidad se recomiendan  
cables combinados 3-en-1 teclado/vídeo/ratón. También están ampliamente disponibles  
cables individuales normales adecuados para el teclado, el vídeo y el ratón.  
Conecte el teclado, el monitor y el ratón al puerto VERDE OSCURO en la parte  
posterior del LINDY CPU Switch Smart.  
RESUMEN DE LA GUÍA DE FUNCIONAMIENTO  
La configuración por defecto del LINDY CPU Switch Smart es adecuada para la  
mayoría de los sistemas.  
Puede seleccionarse un ordenador utilizando la tecla del panel frontal, un ratón de tres  
botones o una combinación de teclas rápidas en el teclado. Para seleccionar un  
ordenador utilizando el ratón, pulse y suelte los botones izquierdo o derecho mientras  
mantiene pulsado el botón del medio. Para seleccionar un ordenador utilizando las  
teclas rápidas del teclado, mantenga pulsadas las teclas CTRL y ALT, pulse y suelte la  
tecla del puerto requerida (p.e. 1) y a continuación suelte las teclas CTRL y ALT.  
Información sobre seguridad  
Solamente debe usarse en interiores, en entornos secos y sin grasa.  
No intente realizar ningún tipo de mantenimiento al LINDY CPU Switch Smart usted  
mismo.  
Siga todos los avisos e instrucciones marcadas en el LINDY CPU Switch Smart, el  
adaptador de potencia opcional y todos sus accesorios.  
Aviso el adaptador de potencia opcional tiene piezas con tensión.  
El adaptador de potencia opcional no contiene piezas que pueda mantener el usuario –  
no desmontarlo.  
Cambie el adaptador de potencia opcional solamente con un tipo aprobado por el  
fabricante.  
Si utiliza una cable de extensión con el LINDY CPU Switch Smart, compruebe que el  
amperaje nominal total de los equipos enchufados en el cable de extensión no superen  
el amperaje nominal del cable de extensión. Asimismo, compruebe que el amperaje  
nominal total de todos los equipos conectados a la toma de red no superen el amperaje  
nominal de la toma.  
LINDY CPU Switch Smart  
SPANISH  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Téléchargez une version Français complète de ce manuel :  
F
Guide dinstallation rapide et mode demploi  
INSTALLATION RAPIDE  
Mettez tous vos ordinateurs hors tension et raccordez-les aux ports VERT CLAIR  
à l'arrière du LINDY CPU Switch Smart. Les câbles clavier/vidéo/souris Adder 3-  
in-1 sont recommandés pour des raisons pratiques. Des câbles clavier, vidéo et  
souris standard se trouvent également facilement sur le marché.  
Raccordez votre clavier, moniteur et souris au port VERT FONCE à l'arrière du  
LINDY CPU Switch Smart.  
MODE DEMPLOI SOMMAIRE  
La configuration par défaut du LINDY CPU Switch Smart convient à la plupart  
des systèmes.  
Pour sélectionner un ordinateur, utilisez la touche du panneau avant, une souris  
à trois boutons ou une combinaison de touches de raccourci clavier. Pour  
sélectionner un ordinateur à l'aide de la souris, maintenez la pression sur le  
bouton central et appuyez sur le bouton gauche ou droite avant de relâcher. Pour  
sélectionner un ordinateur avec les touches de raccourci clavier, maintenez les  
touches CTRL et ALT enfoncées, appuyez sur la touche du port souhaité (ex. 1)  
et relâchez, puis relâchez les touches CTRL et ALT.  
Consignes de sécurité  
A n'utiliser qu'à l'intérieur, dans un environnement sec et exempt d'huile.  
Ne pas assurer soi-même l'entretien du LINDY CPU Switch Smart.  
Observer tous les avertissements et instructions marqués sur le LINDY CPU Switch  
Smart, son adaptateur de courant optionnel et ses accessoires.  
Avertissement l'adaptateur de courant optionnel renferme des pièces sous tension.  
L'adaptateur de courant optionnel ne contient aucune pièce devant être révisée par  
l'utilisateur ne pas le démonter.  
Ne remplacer l'adaptateur de courant optionnel que par un adaptateur approuvé par le  
fabricant.  
Lorsqu'une rallonge est utilisée pour le LINDY CPU Switch Smart, vérifier que l'intensité  
nominale totale des périphériques branchés sur la rallonge ne dépasse pas l'intensité  
nominale du câble. Par ailleurs, vérifier que l'intensité nominale totale de tous les  
périphériques branchés sur la prise murale ne dépasse pas l'intensité nominale de la  
prise murale elle-même.  
LINDY CPU Switch Smart  
FRENCH  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I
Guida di installazione rapida e funzionamento  
INSTALLAZIONE RAPIDA  
Spegnere tutti i computer e collegarli alle porte VERDE CHIARO sul retro del  
LINDY CPU Switch Smart. Per facilità consigliamo i cavi LINDY combinati 3-in-1  
tastiera/video/mouse. Sono pure disponibili cavi mouse, video e tastiera standard  
individuali adatti.  
Collegare la tastiera, monitor e mouse alla porta VERDE SCURO sul retro del  
LINDY CPU Switch Smart.  
SOMMARIO GUIDA OPERATIVA  
La configurazione di default del LINDY CPU Switch Smart è adatta alla maggior  
parte dei sistemi.  
Si può selezionare un computer usando il tasto sul pannello frontale, un mouse a  
tre bottoni o una tastiera con tasti attivi. Per selezionare un computer con il  
mouse, premere e rilasciare i bottoni sinistro o destro trattenendo  
contemporaneamente quello centrale. Per selezionare un computer con tasti attivi  
tastiera, tener premuti i tasti CTRL e ALT, premere e rilasciare il tasto porta  
richiesta (es. 1) e quindi rilasciare i tasti CTRL e ALT.  
Informazionoi riguardanti la sicurezza  
Da usare esclusivamente in interni asciutti e privi di olio.  
Non cercare di effettuare manutenzione sul LINDY CPU Switch Smart.  
Seguire tutti gli avvertimenti ed istruzioni presenti sul LINDY CPU Switch Smart,  
sulladattatore opzionale di potenza e sugli accessori.  
Attenzione ladattatore opzionale di potenza contiene parti sotto tensione.  
Ladattatore opzionale di potenza non contiene parti soggette a manutenzione da parte  
dellutente non smontarlo.  
Sostituire ladattatore opzionale di potenza solo con uno di tipo approvato dal  
produttore.  
Se si usa una prolunga con il LINDY CPU Switch Smart, controllare che la potenza  
nominale totale in ampère dei dispositivi collegati alla prolunga non superi la potenza  
nominale in ampère della prolunga stessa. Controllare inoltre che la potenza nominale  
totale in ampère dei dispositivi collegati non superi la potenza nominale in ampère della  
LINDY CPU Switch Smart  
ITALIAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
presa a muro.  
LINDY CPU Switch Smart  
ITALIAN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About this manual  
LINDY CPU Switch Smart - Installation and Use  
Third edition (June 2001)  
(c) 2001 LINDY Electronics Ltd.  
Part No. LY0039/3  
Part No. 32298  
Part No. 32299  
LINDY CPU Switch Smart 2 Port  
LINDY CPU Switch Smart 4 Port  
All rights reserved. Whilst every precaution has been taken in the preparation of this  
manual, LINDY Electronics Ltd assumes no responsibility for errors or omissions.  
Neither is any liability assumed for damages resulting from the use of the  
information contained herein. We reserve the right to change the specifications,  
functions and circuitry of the product without notice. All trademarks acknowledged.  
Safety information  
For use in dry, oil free indoor environments only.  
Do not attempt to service the LINDY CPU Switch Smart yourself.  
Follow all warnings and instructions marked on the LINDY CPU Switch Smart, its  
optional power adapter and its accessories.  
Warning - live parts contained within optional power adapter.  
No user serviceable parts within optional power adapter - do not dismantle.  
Replace the optional power adapter with a manufacturer approved type only.  
If you use a power extension cord with the LINDY CPU Switch Smart, make sure  
the total ampere rating of the devices plugged into the extension cord does not  
exceed the cords ampere rating. Also, make sure that the total ampere rating of  
all the devices plugged into the wall outlet does not exceed the wall outlets  
ampere rating.  
LINDY CPU Switch Smart  
Installation and Use  
Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LINDY CPU Switch Smart  
Installation and Use  
Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
LINDY Electronics Ltd warrants that this product shall be free from defects in  
workmanship and materials for a period of one year from the date of original  
purchase. If the product should fail to operate correctly in normal use during the  
warranty period, LINDY will replace or repair it free of charge. No liability can be  
accepted for damage due to misuse or circumstances outside LINDYs control. Also  
LINDY will not be responsible for any loss, damage or injury arising directly or  
indirectly from the use of this product. LINDYs total liability under the terms of this  
warranty shall in all circumstances be limited to the replacement value of this  
product.  
If any difficulty is experienced in the installation or use of this product that you are  
unable to resolve, please contact your supplier.  
Trademarks  
All trademarks mentioned in this manual are acknowledged to be the property of the  
respective trademark owners.  
LINDY is a registered trademark of LINDY Electronics Limited.  
Compaq is a registered trademark of Compaq Computer Corporation.  
Hewlett-Packard is a registered trademark of Hewlett-Packard.  
IBM, PC/AT, PS/2, RS/6000 and ThinkPad are registered trademarks of  
International Business Machines Corporation.  
Logitech, MouseMan+ and Pilot Mouse+ are trademarks of Logitech Inc.  
Microsoft and Windows are registered trademarks, and IntelliMouse is a trademark  
of Microsoft Corporation.  
Velcro is a trademark of Velcro USA Inc.  
LINDY CPU Switch Smart  
Installation and Use  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Radio Frequency Energy  
Shielded cables must be used with this equipment to maintain compliance with radio  
frequency energy emission regulations and ensure a suitably high level of immunity  
to electromagnetic disturbances.  
European EMC directive 89/336/EEC  
FCC Compliance Statement (United States)  
This equipment generates, uses and can radiate  
radio frequency energy and if not installed and  
used properly, that is, in strict accordance with  
the manufacturers instructions, may cause  
interference to radio communication. It has been  
tested and found to comply with the limits for a  
class A computing device in accordance with  
the specifications in Subpart J of part 15 of FCC  
rules, which are designed to provide reasonable  
protection against such interference when the  
equipment is operated in a commercial  
environment. Operation of this equipment in a  
residential area may cause interference, in  
which case the user at his own expense will be  
required to take whatever measures may be  
necessary to correct the interference. Changes  
or modifications not expressly approved by the  
manufacturer could void the users authority to  
operate the equipment.  
This equipment has been tested and found to  
comply with the limits for a class B computing  
device in accordance with the specifications in  
the European standard EN55022. These limits  
are designed to provide reasonable protection  
against harmful interference. This equipment  
generates, uses and can radiate radio frequency  
energy and if not installed and used in  
accordance with the instructions may cause  
harmful interference to radio or television  
reception. However, there is no guarantee that  
harmful interference will not occur in a particular  
installation. If this equipment does cause  
interference to radio or television reception,  
which can be determined by turning the  
equipment on and off, the user is encouraged to  
correct the interference with one or more of the  
following measures: (a) Reorient or relocate the  
receiving antenna. (b) Increase the separation  
between the equipment and the receiver. (c)  
Connect the equipment to an outlet on a circuit  
different from that to which the receiver is  
connected. (d) Consult the supplier or an  
experienced radio / TV technician for help.  
Canadian Department of Communications  
RFI statement  
This equipment does not exceed the class A  
limits for radio noise emissions from digital  
apparatus set out in the radio interference  
regulations of the Canadian Department of  
Communications.  
Le présent appareil numérique n’émet pas de  
bruits radioélectriques dépassant les limites  
applicables aux appareils numériques de la  
classe A prescrites dans le règlement sur le  
brouillage radioélectriques publié par le  
ministère des Communications du Canada.  
LINDY CPU Switch Smart  
Installation and Use  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
1. Introduction .................................................................................... 6  
1.1 Key features........................................................................................... 6  
1.2 Package contents .................................................................................. 7  
1.3 Remote controller contents.................................................................... 7  
1.4 Product information ............................................................................... 8  
2. Installation ...................................................................................... 9  
2.1 What you will need ............................................................................... 9  
2.2 Mounting the LINDY CPU Switch Smart ............................................... 10  
2.3 Connecting your devices ...................................................................... 10  
2.4 Interface powered' operation without the optional power adapter ........ 11  
2.5 Configuring your PCs ............................................................................ 11  
2.6 Configuring the LINDY CPU Switch Smart ........................................... 11  
2.7 Summary of LINDY CPU Switch Smart configuration options ............... 12  
2.8 Resetting the LINDY CPU Switch Smart without disconnecting  
your devices .......................................................................................... 14  
2.9 Other useful installation information ..................................................... 14  
2.10 Re-enabling a disconnected PS/2 mouse ........................................... 15  
2.11 Hot plugging the LINDY CPU Switch Smart into running systems and  
re-enabling disconnected PS/2 CPU mouse connections .................. 15  
2.12 Upgrading the LINDY flash memory ................................................... 17  
3. Using the LINDY CPU Switch Smart ............................................ 20  
3.1 Power on status ..................................................................................... 20  
3.2 Front panel keys and remote controller ................................................. 20  
3.3 Status display ........................................................................................ 21  
3.4 Keyboard hotkey control........................................................................ 22  
3.5 Mouse control ........................................................................................ 23  
3.6 RS232 control........................................................................................ 24  
3.7 Cascading LINDY CPU Switch Smarts ................................................. 24  
3.8 Synchronising LINDY CPU Switch Smarts for multiple video head  
LINDY CPU Switch Smart  
Installation and Use  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
applications .......................................................................................... 25  
4. LINDY CPU Switch Smart configuration options........................ 27  
4.1 Screen saver time delay ....................................................................... 27  
4.2 Autoscan lock on mode and delay time ................................................ 27  
4.3 Mouse mode and mouse switching of channels .................................... 28  
4.4 Keyboard hotkey combination ............................................................... 29  
4.5 Cycling between all channels or just the active channels ..................... 30  
4.6 Firmware functions (version query, mouse restore and reset) .............. 30  
4.7 Setting a security password .................................................................. 31  
4.8 Cascade query code ............................................................................. 32  
4.9 Resolving slow mouse problems .......................................................... 32  
4.10 Exit configure mode ............................................................................ 33  
Appendices  
A - Cable and connector specifications................................................................ 34  
B - Problem solving.............................................................................................. 38  
LINDY CPU Switch Smart  
Installation and Use  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Introduction  
Thank you for purchasing the LINDY CPU Switch Smart. Your LINDY CPU Switch  
Smart is a high performance keyboard, monitor and mouse sharing device which  
supports a wide range of PC hardware and software platforms.  
1.1 Key features  
Control multiple PCs from a single keyboard, monitor and mouse.  
Continuous keyboard and mouse emulation on all ports ensures problem free  
computer bootup.  
Interface powered operation LINDY CPU Switch Smart draws its power from the  
connected computers for maximum convenience.  
Intelligent switching feature enables users to switch between all ports or just the  
active ports.  
Supports high bandwidth monitors at resolutions up to 1900 x 1440 with an  
excellent video transfer characteristic - high bandwidth and low distortion.  
Mixed AT/PS2 keyboards and PS2/RS232 mice supported as standard.  
Flash upgradeable - LINDY CPU Switch Smart's firmware may be upgraded by  
connecting a computer's serial port and running a download program.  
Can be cascaded to provide a video switching network.  
Video channels support Display Data Channel (DDC/DDC1/DDC2) signalling.  
Password security prevents unauthorised use.  
User options stored in EEPROM memory.  
Remote control module for convenient operation.  
Channel switching by front panel key, keyboard hotkey, or 3 button mouse.  
Automatically restores keyboard and mouse states when channel changed.  
Supports keyboard modes 1,2 and 3 and mouse prompt and stream modes for  
maximum compatibility.  
Can be controlled remotely via an RS232 serial port.  
LINDY CPU Switch Smart  
Installation and Use  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Includes screen saver, auto-scan and variable hotkey options.  
Supports Microsoft IntelliMouse, IntelliMouse Explorer and other common wheel  
mice.  
Mouse restoration functions to enable hot pluggingof certain systems.  
Keyboard, mouse and LINDY CPU Switch Smart resets may be performed without  
disconnecting devices.  
Supports IBM ThinkPad Ycables.  
Power and activity indication confirm correct operation.  
Standard cable connections make installation easy and inexpensive.  
All ports are active simultaneously all PCs may all be booted at the same time.  
Robust metal case ensures good shielding and video quality.  
Supports desktop and laptop PCs, RS6000s, DEC Alphas, and Silicon Graphics  
computers .  
Supports very wide range of software including Windows 3.X, WFWG, 95, 98,  
2000, ME, XP, NT, DOS, Unix, Linux, NetWare, OS/2, BSD etc.  
Optional power adapter can be used for video onlyor cascade applications.  
1.2 Package contents  
LINDY CPU Switch Smart.  
This installation guide.  
(Please note that a power adapter is NOT required for most applications and so is  
not included. This may be purchased separately if required - part code  
AVGPSU).  
1.3 Remote controller contents (part code: RC1)  
Remote control module.  
Velcro strip for mounting remote controller.  
LINDY CPU Switch Smart  
Installation and Use  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 Product information  
Figure 1 - LINDY CPU Switch Smart front view  
Figure 2 - LINDY CPU Switch Smart rear view (4 port model)  
Figure 3 - Remote control pad / display (optional accessory - part 32255)  
LINDY CPU Switch Smart  
Installation and Use  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Installation  
2.1 What you will need  
Cables to connect the LINDY CPU Switch Smart to each of your PC keyboard,  
video and mouse ports. Cable specifications are given in appendix A. (You do not  
need to connect a mouse cable if you are not using the mouse).  
A monitor with a standard VGA/SVGA (15 pin) connector that will work when  
connected directly to each of your PCs. LINDY CPU Switch Smart supports low and  
high resolution monitors.  
A standard AT or PS/2 style keyboard. If you are using an AT keyboard with a 5  
pin connector you may connect this to the LINDY CPU Switch Smart using a  
standard AT to PS/2 keyboard adapter.  
A PS/2 style two or three button Microsoft or Logitech compatible mouse or a  
Microsoft IntelliMouse / IntelliMouse Explorer compatible mouse. If you wish to use  
the mouse to switch the LINDY CPU Switch Smarts channel then you will need a  
three button mouse or an IntelliMouse.  
(The LINDY CPU Switch Smart supports Internet Micethat are compatible with the  
Microsoft IntelliMouse. These are fitted with a wheel or other scroll control and  
sometimes have additional buttons. Examples are: Microsoft IntelliMouse, Logitech  
Pilot Mouse+, Logitech MouseMan+, Genius NetMouse and Genius NetMouse Pro.)  
A suitable mouse driver for your PCs. Supported types are:  
- PS/2 or RS232 two button mouse driver (any manufacturer).  
- Microsoft mouse driver (including IntelliMouse).  
- Logitech mouse driver (including two button, three button and wheel mouse)  
Use of PS/2 and RS232 style mice with the LINDY CPU Switch Smart - All of the  
mouse connections from LINDY CPU Switch Smart to PCs support either a PS/2 or  
an RS232 mouse. LINDY CPU Switch Smart automatically converts from the PS/2  
mouse commands to RS232 serial mouse commands. Serial mice types are  
selected by using an adapter as described in Appendix A. The LINDY CPU Switch  
Smart will operate without a mouse connected if you do not wish to use one.  
LINDY CPU Switch Smart  
Installation and Use  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Mounting the LINDY CPU Switch Smart  
The LINDY CPU Switch Smart has been designed for use on a desktop or shelf in  
close proximity to the users monitor and peripherals. The optional remote controller  
may be used if you wish to locate the LINDY CPU Switch Smart on a desk or shelf  
that is some distance from the monitor and peripherals.  
2.3 Connecting your devices  
Ensure that the optional power adapter is disconnected from the LINDY CPU Switch  
Smart and that all the devices which are to be attached are switched off. Connect  
the shared keyboard, PS/2 mouse and monitor to the connectors at the rear of the  
LINDY CPU Switch Smart (see figs 1, 2 and 3). Next, connect each computer  
system unit in turn with the keyboard cable, mouse cable and video cable. LINDY 3-  
in-1 keyboard/video/mouse cables are recommended for maximum convenience.  
Any unused computer connections can be left unconnected. To connect computers  
with serial mouse connections and AT style keyboard connections use the adapters  
specified in appendix A. If you have an existing 6-pin mini-DIN to 9-pin serial  
adapter that came with a mouse it may not be suitable for use with the LINDY as  
there are several different standard wiring configurations for these adapters.  
The LINDY CPU Switch Smart is now ready for use and will start to operate as soon  
as one of the attached PCs is powered on. If you are connecting to PCs using  
cables that are longer than 5 metres or are cascading the LINDY CPU Switch Smart  
to another LINDY CPU Switch Smart you will need to use the optional power  
adapter. When using the optional power adapter, ensure that it is connected to the  
mains and powering the LINDY CPU Switch Smart before you switch on the  
LINDY CPU Switch Smart  
Installation and Use  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
connected computers. Failure to switch the LINDY CPU Switch Smart and  
computers on in the correct order can lead to the mouse and/or keyboard not being  
recognised by the computers when they are switched on.  
2.4 Interface poweredoperation without the optional power  
adapter  
The LINDY CPU Switch Smart draws its power from the connected computers via  
the keyboard cables. A single keyboard connection is normally sufficient to power  
the LINDY CPU Switch Smart provided that the cable is no longer than 5 metres. If  
more than one computer is connected then the power will be intelligently drawn from  
all computers. Cables longer than 5 metres may be used provided that the LINDY  
CPU Switch Smart is already powered by another connected computer or the  
optional power adapter. If you are cascading the LINDY CPU Switch Smart to  
another LINDY CPU Switch Smart then a power adapter must be connected to all  
LINDY CPU Switch Smarts.  
2.5 Configuring your PCs  
Configure your PC in the same way that you would if your keyboard, mouse and  
monitor were all connected directly to your PC. LINDY CPU Switch Smart emulates  
Microsoft compatible serial, IntelliMouse, IntelliMouse Explorer and PS/2 mice, so  
ensure that your PC software is configured for a Microsoft mouse of the correct type.  
Refer to the list of supported drivers in section 2.1.  
2.6 Configuring the LINDY CPU Switch Smart  
The LINDY CPU Switch Smart is supplied pre-configured with factory defaults which  
are suitable for most applications. There are a number of more advanced options  
which can be set by the user. These are stored in the LINDY CPU Switch Smarts  
EEPROM memory and are retained when the power is disconnected.  
The options may be changed whilst the LINDY CPU Switch Smart is in configure  
mode. You may enter configure mode at initial power on or whilst the LINDY CPU  
Switch Smart is running:  
To enter configure mode at power on:  
Switch off all the attached PCs and the LINDY CPU Switch Smart. Hold down the  
front panel key whilst powering on the LINDY CPU Switch Smart. Remember that  
the LINDY CPU Switch Smart draws its power from any attached PC via the  
LINDY CPU Switch Smart  
Installation and Use  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
keyboard cable and so will power itself on when the attached PC is switched on or  
when the optional power adapter is connected. Do not release the key until the  
LINDY CPU Switch Smart displays Cto show that it has entered configure mode.  
To enter configure mode whilst the LINDY CPU Switch Smart is running:  
Hold down the front panel key for 5 seconds until the front panel display shows C.  
In configure mode, options are entered by typing a letter followed by a number  
followed by (return). Use ESC to abort the entry of an option. The LINDY CPU  
Switch Smart will remain in configure mode until you type 'E' (return).  
For example: to set hotkey option 2 type the following at the 'C' prompt  
(at LINDY CPU Switch Smart 'C' prompt)  
+ꢁꢀ  
I
To exit configure mode type:  
(ꢀ  
I
2.7 Summary of LINDY CPU Switch Smart configuration options  
Full details of each of the configuration options and their uses are given in section 4.  
B1 - screen saver disabled (default)  
B2 - Blank screen after 1 minute of inactivity  
B3 - Blank screen after 2 minutes of inactivity  
B4 - Blank screen after 4 minutes of inactivity  
B5 - Blank screen after 8 minutes of inactivity  
B6 - Blank screen after 12 minutes of inactivity  
B7 - Blank screen after 16 minutes of inactivity  
B8 - Blank screen after 20 minutes of inactivity  
L1 - CPU Switch Smart locks on to active ports only during autoscanning (default)  
L2 - CPU Switch Smart locks on to every port during autoscanning  
L3 - CPU Switch powers on in autoscan mode and locks on to active ports only  
L4 - CPU Switch Smart powers on in autoscan mode and locks on to all ports  
L5 Allow the mouse to run at any speed (default)  
L6 Don't allow the mouse to run at very slow speeds  
LINDY CPU Switch Smart  
Installation and Use  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LINDY CPU Switch Smart  
Installation and Use  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
L7 - Cascade query code = AD (default)  
L8 - Cascade query code = EF  
T1 - 2 seconds autoscan delay time before switching to next port (default)  
T2 - 5 seconds autoscan delay time before switching to next port  
T3 - 7 seconds autoscan delay time before switching to next port  
T4 - 10 seconds autoscan delay time before switching to next port  
T5 - 15 seconds autoscan delay time before switching to next port  
T6 - 20 seconds autoscan delay time before switching to next port  
T7 - 30 seconds autoscan delay time before switching to next port  
T8 - 60 seconds autoscan delay time before switching to next port  
U1 - LINDY CPU Switch Smart channels are switchable using a 3 button mouse  
or IntelliMouse (default)  
(LINDY CPU Switch Smart reports 2 button mouse mode to PCs)  
U2 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports 2 button mouse mode to PCs)  
U3 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports 3 button mouse mode to PCs)  
U4 - LINDY CPU Switch Smart channels are switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports IntelliMouse mode to PCs)  
U5 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports IntelliMouse mode to PCs)  
U7 Cycle between all ports when switching with Hotkeys + Tabor three button  
mouse (default)  
U8 Cycle between active ports only when switching with Hotkeys + Tabor three  
button mouse  
H1 - Hotkey combination is CTRL + ALT + command key (default)  
H2 - Hotkey combination is CTRL + SHIFT + command key  
H3 - Hotkey combination is ALT + SHIFT + command key  
H4 - Hotkey combination is RIGHT ALT + command key  
H5 - Hotkey combination is LEFT ALT + RIGHT ALT + command key  
H6 - Hotkey combination is LEFT CTRL + LEFT ALT + command key  
H7 - Hotkey combination is RIGHT CTRL + RIGHT ALT + command key  
H8 - No hotkey combination enabled  
LINDY CPU Switch Smart  
Installation and Use  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F1 - Display firmware first digit (Note: F1 is ) followed by NOT O)  
F2 - Display firmware second digit  
F3 - Display firmware third digit  
F5 - Restore PS/2 mouse function  
F6 - Restore IntelliMouse function  
F8 - RESET all configurations to default settings. (Display confirms with r).  
P - Sets password - see section 4.6 for instructions.  
E - Exits configure mode and returns the LINDY CPU Switch Smart to normal  
operation mode.  
2.8 Resetting the LINDY CPU Switch Smart without disconnecting  
your devices  
The LINDY CPU Switch Smart draws its power from the connected computers and  
therefore may only be fully powered down when all the connected computers have  
been switched off or disconnected. However, the LINDY CPU Switch Smart may be  
reset without disconnecting or powering down your computers by using the reset  
switch on the underside of the unit. Performing a reset using this switch performs a  
complete hardware reset on the LINDY CPU Switch Smart and is equivalent to  
switching off the power. To perform a hardware reset, move option switch 8 to the  
ON position (halt and reset) and then back to the OFF position (normal operation).  
2.9 Other useful installation information  
PC boot up sequence - When your PCs are powered on they communicate with  
any attached keyboards and mice and setup parameters required by the particular  
operating system. It is necessary for the LINDY CPU Switch Smart to be attached  
and powered on during this sequence so that it can give the required responses and  
keep track of all the modes and settings requested by each of the connected PCs.  
Mouse characteristics - do not unplug a PS/2 mouse connection from a PC whilst  
the PC is on. Due to the design of PS/2 mice communications the mouse function on  
the PC will be lost and you will have to re-boot the PC to regain normal operation.  
Unplugging the mouse from the LINDY CPU Switch Smart will also cause it to stop  
operating when it is plugged back in. RS232 mice can usually be unplugged and  
plugged back in provided that a mouse was connected when the operating system  
initially booted. The LINDY CPU Switch Smart is fitted with a PS/2 mouse recovery  
LINDY CPU Switch Smart  
Installation and Use  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
system which allows you to disconnect and re-connect the shared mouse without  
powering down the system (although this is generally not advisable) - see section  
2.10 for details.  
Keyboard and mouse mode switching - The LINDY CPU Switch Smart keeps a  
log of the keyboard and mouse mode and resolution settings requested by each of  
the connected PCs. These settings are automatically restored to the shared  
keyboard and mouse when the LINDY CPU Switch Smart channel is switched thus  
ensuring maximum software compatibility. The keyboard num, caps and scroll lock  
states are an obvious example of this process.  
2.10 Re-enabling a disconnected PS/2 mouse  
If you disconnect the shared PS/2 mouse from the LINDY CPU Switch Smart by  
accident during operation then the mouse operation will be lost when the mouse is  
plugged back in. To avoid having to reboot the entire system in this situation the  
LINDY CPU Switch Smart is fitted with an automatic mouse recovery system.  
With the PS/2 mouse disconnected, change the channel using the keypad or  
keyboard hotkeys. The LINDY CPU Switch Smart detects that the mouse has been  
disconnected and triggers the automatic recovery system. Plug in the PS/2 mouse  
and the LINDY CPU Switch Smart will re-initialise it.  
Alternatively you can reset the keyboards and mice by holding down the front panel  
key for 5 seconds. When the character Cis displayed on the front of the LINDY  
CPU Switch Smart, press the front panel key again. A complete power off reset of  
the connected keyboards and mice will then be performed. This function only resets  
the shared keyboard and mice that are plugged into the control port. It does not  
affect the status of any of the other ports on the switch or the CPU connections.  
2.11 Hot plugging the LINDY CPU Switch Smart into running  
systems and re-enabling disconnected CPU PS/2 mouse  
connections  
It is advisable to switch off the systems that are going to be connected to the LINDY  
CPU Switch Smart before installation. However, if this is not possible then most  
systems can be hot plugged by using the LINDY CPU Switch Smarts mouse  
restoration functions. The keyboard connection will normally restore itself  
automatically.  
LINDY CPU Switch Smart  
Installation and Use  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
On many PCs, mouse movement will be lost if the PS/2 mouse is unplugged and  
plugged back in whilst the PC is running. Mouse movement can then only be  
restored by rebooting the PC. This is because the mouse drivers only setup and  
enable the mouse when the PC is initially booted.  
If you have switched off your LINDY CPU Switch Smart or you are attempting to hot  
plugit into a system that is already running, you may be able to restore lost mouse  
movement using the LINDY CPU Switch Smart's mouse restoration functions.  
Mouse restoration functions should be used with care as unpredictable results  
may occur if the wrong mouse type is selected. If in doubt restore the mouse  
by powering down the PC normally.  
Standard PS/2 mouse data uses a different data format to IntelliMouse data and so  
two reset functions are provided on the LINDY CPU Switch Smart. The type of data  
format expected by the PC depends upon the driver and the type of mouse that was  
connected when the driver was booted. The following table may be used as a guide.  
Note that the mouse reset functions predict the likely mouse resolution settings but  
may not restore the speed or sensitivity of the mouse exactly as they were when the  
PC originally booted.  
Type of mouse / system Driver type  
Connected at bootup  
Likely expected  
data format  
Suggested  
restoration  
PS/2  
PS/2 only  
PS/2  
F5  
F5  
F5  
F6  
PS/2  
IntelliMouse  
PS/2 only  
PS/2  
IntelliMouse/CPU Switch  
IntelliMouse/CPU Switch  
PS/2  
IntelliMouse  
IntelliMouse  
To restore lost mouse movement on a CPU connected to the LINDY CPU Switch  
Smart:  
1) Select the CPU that has lost its mouse movement  
2) Press the select key on the front of the LINDY CPU Switch Smart for 5 seconds  
until Cis displayed. You are now in configure mode.  
3) To restore a PS/2 mouse connection press  
)ꢀꢃꢀ  
I
Or, to restore an IntelliMouse connection press  
LINDY CPU Switch Smart  
Installation and Use  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
)ꢀꢄꢀ  
Iꢀ  
4) Exit from configure mode by typing  
(ꢀ  
I
5) Test the mouse movement by moving the mouse a short distance.  
F5 - Restore PS/2 mouse function  
F6 - Restore IntelliMouse function  
2.12 Upgrading the LINDY flash memory  
The LINDY CPU Switch Smart uses flash memory technology which enables the  
firmware code to be upgraded by the user. Upgrades are performed by connecting a  
PCs serial port to the LINDYs options port and running an upgrade program on the  
PC. This upgrade program downloads the new firmware to the LINDY CPU Switch  
Smart and checks that the data has been programmed correctly.  
To perform a firmware upgrade on your LINDY CPU Switch Smart you will need a  
suitable serial upgrade cable and an IBM PC compatible computer with an RS232  
serial port and an operating system that supports DOS. Upgrade cables may be  
purchased for LINDY Technology or may be made using the wiring specification  
given in Appendix A4. You will also need to download the latest version of the  
LINDY CPU Switch Smart firmware which is available free of charge at  
To perform a flash upgrade on the LINDY CPU Switch Smart:  
Step 1 - Connect your computer to the LINDY CPU Switch Smart  
Connect your computers serial port to the LINDY CPU Switch Smarts options port  
(labelled OPTIONS/FLASH).  
Step 2 - Select flash upgrade mode using option switch 7  
Move option switch 7 on the underside of the LINDY CPU Switch Smart to the ON  
position.  
Step 3 - Reset the LINDY CPU Switch Smart  
Reset the LINDY CPU Switch Smart by moving option switch 8 to the ON position  
(halt and reset) and then back to the OFF position (normal operation). Alternatively  
LINDY CPU Switch Smart  
Installation and Use  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
you may reset the LINDY CPU Switch Smart by powering off all the attached  
computers and removing the optional power adapter.  
Step 4 - Ensure that the LINDY CPU Switch Smart is powered on  
Ensure that the LINDY CPU Switch Smart is powered on. It is normally possible to  
upgrade the LINDY CPU Switch Smart when it is powered from a single computer,  
however it is good practice to ensure that there is the maximum possible power  
availability during flash upgrades and so if possible ensure that all the computers  
are powered on. The upgrade program monitors the LINDY CPU Switch Smarts  
voltage and will not allow an upgrade to be performed if the voltage is insufficient.  
The display should now show:  
Step 5 - Run the upgrade program  
The latest version of the LINDY CPU Switch Smart firmware is available from the  
LINDY Technology website at www.lindy.com. The program and data files are  
supplied as a pair e.g.  
CPUSS129.EXE  
CPUSS129.HEX  
and should be downloaded to the same directory on your PC. Run the file  
CPUSSxxx.EXE (e.g. CPUSS129.EXE) and follow the on-screen instructions. During  
the upgrade the display will show an upper case U and the dot will flash to show that  
the upgrade is in progress.  
The display will again show a lower case U when the download is complete. Move  
option switch 7 to the OFF position to exit upgrade mode and start normal operation.  
LINDY CPU Switch Smart  
Installation and Use  
Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
You may check the new firmware version by entering configure mode and using the  
firmware version query function.  
LINDY CPU Switch Smart  
Installation and Use  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Some useful issues to bear in mind when performing flash upgrades  
The upgrade program rewrites the LINDY CPU Switch Smarts firmware code. If the  
upgrade process is interrupted then the LINDY CPU Switch Smart will have invalid  
code and will not be able to operate. It is therefore good practice to ensure that the  
upgrade process is always fully completed. A partial or failed upgrade may be  
rectified by performing another upgrade. If the upgrade process is interrupted  
accidentally then you should immediately repeat the upgrade process without  
moving switch 7 from the flash upgrade (ON) position. Switch 7 forces the LINDY  
CPU Switch Smart into flash upgrade mode and prevents the upgraded code from  
being run. Running faulty or partially upgraded code may have unpredictable results  
and may damage your LINDY CPU Switch Smart or computing equipment. For  
obvious reasons, the code that the LINDY CPU Switch Smart uses to perform  
upgrades is not itself upgradeable - a common problem on some flash upgradeable  
products that could effectively be destroyed by a partial upgrade!  
WARNING - Running faulty or partially upgraded code may have unpredictable  
results and may damage your LINDY CPU Switch Smart or computing  
equipment.  
LINDY CPU Switch Smart  
Installation and Use  
Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Using the LINDY CPU Switch Smart  
This section explains the general operation of the LINDY CPU Switch Smart. We  
recommend that you read this section before starting to use the product.  
3.1 Power on status  
At power on the LINDY CPU Switch Smart selects computer 1 and displays 1. If a  
password has been set then Pwill be displayed and the LINDY CPU Switch Smart  
will remain locked until a valid password is entered.  
3.2 Front panel key and remote controller  
The front panel key is used to select which channel is currently controlled by the  
shared keyboard, mouse and monitor ports. Pressing the key during normal  
operation will cause the next channel to be selected.  
The key can also be used to access the LINDY CPU Switch Smarts configuration  
mode (see section 2.6). To do this press the key and hold it down for 5 seconds until  
Cappears on the LINDY CPU Switch Smarts front panel display.  
An optional remote controller is also available which replicates the front panel key  
and display, but can be located remotely from the LINDY CPU Switch Smart. This is  
particularly useful in applications where the LINDY CPU Switch Smart is located  
away from the desktop. The remote controller can be conveniently attached to your  
keyboard with a couple of Velcro strips to give instant channel information and key  
control.  
LINDY CPU Switch Smart  
Installation and Use  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3 Status display  
The status display usually shows the currently selected port. If autoscan mode is  
selected, the segments will illuminate in sequence in a clockwise direction  
interspersed with a display of the currently selected channel. If LINDY CPU Switch  
Smart has been locked, Pwill be displayed until a valid password has been typed  
to unlock the unit. Data flow from the mouse or keyboard causes the dot to flash.  
LINDY CPU Switch Smart  
Installation and Use  
Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 Keyboard hotkey control  
LINDY CPU Switch Smart can be conveniently controlled by selecting channel,  
autoscan mode or security locking from the keyboard. All of the hotkey control  
commands are invoked by holding down the two hotkeys and then pressing a  
command key. By default, the two hotkeys are CTRLand ALT, although other  
combinations can be selected by reconfiguring the hotkeys (see section 4.4). Once  
the hotkey command has been activated you will need to release the hotkeys and  
the command key before a new hotkey command is accepted by the LINDY CPU  
Switch Smart. HOTKEYs + TAB is an exception and this allows you to 'tab through'  
the ports by holding down the hotkeys and repeatedly pressing TAB.  
The hotkey command are summarised below (note that the numbers on the numeric  
keypad do not form part of a valid hotkey) :  
HOTKEYsand 1- selects channel 1  
HOTKEYsand 2- selects channel 2  
HOTKEYsand 3- selects channel 3  
HOTKEYsand 4- selects channel 4  
HOTKEYsand TAB- selects the next channel  
HOTKEYsand A- selects autoscan mode where each channel is displayed for  
the selected time (see section 4.2). To cancel autoscan mode simply select any  
fixed channel either by hotkey or using the LINDY CPU Switch Smart button.  
HOTKEYsand 0switches off the video signal and displays 0. This will cause  
some monitors to go into standby mode or switch off. The video signal can be re-  
enabled by selecting a channel.  
HOTKEYsand L- disables the LINDY CPU Switch Smarts keyboard and mouse  
and displays 0. The video signal is switched off. If a password has not been set then  
the LINDY CPU Switch Smart can be re-enabled by selecting a channel. If a  
password has been set then the LINDY CPU Switch Smart displays Pto indicate  
that a valid password must be entered to unlock the switch. Simply type the same  
key combination as was set during configuration (see section 4.7) followed by the  
(return) key. Note - if anyone has typed at the keyboard whilst in secure mode, it will  
be necessary to type (return) first to clear the invalid password, then type the valid  
password followed by (return) again.  
LINDY CPU Switch Smart  
Installation and Use  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Examples of common hotkey sequences (assuming CTRL + ALT hotkey option):  
To select channel 2:  
press EDꢁ ꢁED  
release  
To ’tab through’ channels:  
press ED Yrelease YpressY  
release Ypress Y release YED  
3.5 Mouse control  
Computers may conveniently be selected using a three button mouse. In order to  
switch to the next computer simply hold down the central mouse button (the wheel  
mouse button on an IntelliMouse) and click on the left hand mouse button to select  
the next computer or the right hand mouse button to select the previous computer. If  
the LINDY CPU Switch Smart has been set to scan active ports then the next or  
previous active channel will be selected. If it has been set to scan all ports then the  
next or previous numerical channel in sequence will be selected (see section 4.5 for  
more details). Mouse switching may be enabled or disabled by setting options  
during configuration (see section 4.3). When mouse switching is disabled the third  
button or wheel button state is passed throughthe LINDY CPU Switch Smart and  
seen by the application software.  
Hold down centre button (  
Press and release left hand button  
) to select next computer  
)
Hold down centre button (  
Press and release right hand button  
( ) to select previous computer  
)
(
LINDY CPU Switch Smart  
Installation and Use Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6 RS232 control  
LINDY CPU Switch Smart can be controlled by a remote RS232 device. To select a  
channel the data rate of the sending device must be set to 1200 baud, 8 bits, no  
parity and 1 stop bit. No handshaking is used by the LINDY CPU Switch Smart.  
Simply send the character for the channel which needs to be selected, for example  
ASCII 1(hex code 31) will select channel 1, ASCII 2(hex code 32) will select  
channel 2 and so on. The LINDY CPU Switch Smart will echo the ASCII character  
back to the sending device when the channel has been changed. The serial  
interface pins are found on the options connector on the rear of the LINDY CPU  
Switch Smart. Pin assignments for this connector are given in appendix A  
3.7 Cascading LINDY CPU Switch Smarts  
LINDY CPU Switch Smart switches can be connected together to expand the  
number of connected computers. When cascading LINDY CPU Switch Smarts a  
power adapter must be connected to each LINDY CPU Switch Smart. LINDY CPU  
Switch Smarts can be connected in a cascaded tree structure. This can be  
particularly useful where clusters of computers are located some distance from each  
other because each unit acts as data booster and can each be up to 30 metres  
away from the next LINDY CPU Switch Smart. The channel can be selected on  
remote LINDY CPU Switch Smart units using an extension of the HOTKEY control .  
For example, consider a situation where two LINDY CPU Switch Smart units are  
connected together as shown below. To connect to the computer attached to port 3  
on LINDY CPU Switch Smart B the user would hold down the hotkey keys then  
press 2followed by 3, whilst keeping the hotkey keys pressed. This will have the  
effect of connecting to port 3of the LINDY CPU Switch Smart which is connected  
into port 2of the first LINDY CPU Switch Smart unit A.  
For example to connect to port 3 on the LINDY CPU Switch Smart cascaded off port  
2 of your first LINDY CPU Switch Smart use:  
press ED  
release  
ED  
press release  
LINDY CPU Switch Smart  
Installation and Use  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A typical cascade of two LINDY CPU Switch Smarts  
3.8 Synchronising LINDY CPU Switch Smarts for multiple video  
head applications  
Multiple LINDY CPU Switch Smarts may be connected together so that they operate  
in a synchronised manner. Synchronised operation is useful for applications that  
require multiple video signals to be switched together. This type of operation is  
usually required where each computer is fitted with multiple video cards or video  
cards with multiple video heads. Such configurations are typically required in  
banking and engineering applications where greater video real estateis required.  
Whenever the LINDY CPU Switch Smarts channel is switched it sends an RS232  
command out on its serial interface. The LINDY CPU Switch Smart switches its  
LINDY CPU Switch Smart  
Installation and Use  
Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
channel if it receives the same command on its serial interface. Consequently, by  
linking the serial interfaces a master unit may be made to automatically switch a  
daisy chain of slaved units as shown in the diagram below. The slave units will  
require the optional power adapters because they cannot draw their power from the  
video link alone.  
Synchronised LINDY CPU Switch Smarts used for a dual head video switching  
application  
LINDY CPU Switch Smart  
Installation and Use  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. LINDY CPU Switch Smart configuration  
options  
All the options described in this section are entered in LINDY CPU Switch Smart  
configure mode - see section 2.6 for instructions on entering configure mode.  
4.1 Screen saver time delay  
LINDY CPU Switch Smart contains a programmable screen saver which will blank  
the display after the set time delay with no keyboard or mouse activity. Simply typing  
at the keyboard or moving the mouse will re-enable the display. The display will  
flash whilst the LINDY CPU Switch Smart is in screen save mode.  
B1 - screen saver disabled (default)  
B2 - Blank screen after 1 minute of inactivity  
B3 - Blank screen after 2 minutes of inactivity  
B4 - Blank screen after 4 minutes of inactivity  
B5 - Blank screen after 8 minutes of inactivity  
B6 - Blank screen after 12 minutes of inactivity  
B7 - Blank screen after 16 minutes of inactivity  
B8 - Blank screen after 20 minutes of inactivity  
4.2 Autoscan lock onmode and delay time  
LINDY CPU Switch Smart can be set to select each channel in turn for a period of  
time set by the autoscan delay time. Autoscan mode is entered by typing the hotkey  
keys together with A. By default, only those channels which have a powered up  
computer connected to them will be scanned. Sometimes it may be desirable to  
scan all channels, even if the attached computer is switched off (this will simply  
show a blank screen when it is selected). All the LINDY CPU Switch Smarts ports  
will be scanned if option L2 is selected. Some applications may also require the  
LINDY CPU Switch Smart to power on in autoscan mode. This feature can be  
selected using the L3 or L4 options.  
LINDY CPU Switch Smart  
Installation and Use  
Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
L1 - CPU Switch Smart only locks on to active ports during autoscanning (default)  
L2 - CPU Switch Smart locks on to every port in turn during autoscanning  
L3 - CPU Switch powers on in autoscan mode and locks on to active ports only  
L4 - CPU Switch Smart powers on in autoscan mode and locks on to all ports  
T1 - 2 seconds autoscan delay time before switching to next port (default)  
T2 - 5 seconds autoscan delay time before switching to next port  
T3 - 7 seconds autoscan delay time before switching to next port  
T4 - 10 seconds autoscan delay time before switching to next port  
T5 - 15 seconds autoscan delay time before switching to next port  
T6 - 20 seconds autoscan delay time before switching to next port  
T7 - 30 seconds autoscan delay time before switching to next port  
T8 - 60 seconds autoscan delay time before switching to next port  
Note: Autoscan mode is ended simply by selecting a fixed channel using the  
keypad, the keyboard hotkeys or the mouse.  
WARNING - Many modern monitors are fitted with automatic power save relays  
and will switch off after a few seconds if connected to an inactive PC. If you  
are using such a monitor you must not use the L2 feature. Constant switching  
on and off of your monitors relay will eventually damage your monitor.  
4.3 Mouse mode and mouse switching of channels  
A three button PS/2 mouse or an IntelliMouse can be used to switch channels on the  
LINDY CPU Switch Smart. To switch to the next channel, the user simply holds  
down the central button or wheel button and presses the left or right hand button to  
change the channel (see section 3.5). If the user does not wish to take advantage of  
this feature, it can be disabled by selecting U2, U3 or U5. If the third button is being  
used to switch the LINDY CPU Switch Smart then it is not available for use with PC  
software although the function of an IntelliMouse wheel is not affected.  
Consequently in modes U1, U2 and U4 the LINDY CPU Switch Smart reports to the  
PCs that a 2 button mouse is connected. If you wish to use the full function of a 3  
button mouse or IntelliMouse for your PC software then you should select options  
U3 or U5.  
LINDY CPU Switch Smart  
Installation and Use  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The LINDY CPU Switch Smart supports Internet Micethat are compatible with the  
Microsoft IntelliMouse. These are fitted with a wheel or other scroll control and  
sometimes have additional buttons.  
Examples are:  
Microsoft IntelliMouse  
Logitech Pilot Mouse +  
Logitech MouseMan+  
Genius NetMouse  
Genius NetMouse Pro  
Standard PS/2 and IntelliMouse compatible mice can be connected to the control  
port. You may configure your CPUs using Microsoft PS/2 or IntelliMouse drivers in  
any combination as required. The IntelliMouse features are supported on both PS/2  
and RS232 CPU connections. When using PS/2 CPU connections, the LINDY CPU  
Switch Smart will automatically configure itself to the type of mouse requested by  
the driver. If you are using RS232 CPU connections then you will need to select  
mouse options U4 or U5 to enable the IntelliMouse features.  
U1 - LINDY CPU Switch Smart channels are switchable using a 3 button mouse  
or IntelliMouse (default)  
(LINDY CPU Switch Smart reports 2 button mouse mode to PCs)  
U2 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports 2 button mouse mode to PCs)  
U3 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports 3 button mouse mode to PCs)  
U4 - LINDY CPU Switch Smart channels are switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports IntelliMouse mode to PCs)  
U5 - LINDY CPU Switch Smart channels are not switchable using 3 button mouse  
or IntelliMouse  
(LINDY CPU Switch Smart reports IntelliMouse mode to PCs)  
4.4 Keyboard hotkey combination  
The keyboard hotkey combination is used to change a channel, set autoscan mode  
or secure the product (so that the password needs to be typed before it can be used  
LINDY CPU Switch Smart  
Installation and Use  
Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
again). The following keyboard hotkey combinations can be selected. These hotkey  
combinations are used together with the command keys to trigger the required CPU  
Switch function. The left and right shift key combination is particularly suitable for  
extended keyboards where additional keys can be programmed to act as a  
combination of other keys. Such keyboards are supplied with many Gateway 2000  
computers. Programming spare keys to trigger the hotkey combination allows  
channels to be selected via a single key stroke.  
H1 - CTRLand ALTkeys together (left or right hand keys operate) (default)  
H2 - CTRLand SHIFTkeys together (left or right hand keys operate)  
H3 - ALTand SHIFTkeys together (left and right hand keys operate)  
H4 - RIGHT ALTkey  
H5 - LEFT ALTand RIGHT ALTkeys together  
H6 - LEFT CTRLand LEFT ALTkeys together  
H7 - RIGHT CTRLand RIGHT ALTkeys together  
H8 - No hotkey enabled  
4.5 Cycling between all channels or just the active channels  
The LINDY CPU Switch Smart can be set to cycle between all channels or just the  
active channels when using Hotkeys + Tabor a three button mouse to switch the  
channel. This avoids wasting time viewing channels that are not active. Option are:  
U7 Cycle between all ports when switching with Hotkeys + Tabor three button  
mouse (default)  
U8 Cycle between active ports only when switching with Hokeys + Tabor three  
button mouse  
4.6 Firmware functions (version query, mouse restore and reset)  
For technical support purposes, it may be necessary to find the firmware release  
version for the control software in your LINDY CPU Switch Smart. For example, if  
the release version is v1.29 the response shown to )ꢂI will be a brief display  
of the digit 1, then )ꢁI will be a brief display of the digit 2, then )ꢅI  
will be a brief display of the digit 9. You can reset all of the configured options back  
to the factory default states by typing )ꢆI. Use options )ꢃI and  
)ꢄI to restore mouse function on disconnected PS/2 CPU mouse  
LINDY CPU Switch Smart  
Installation and Use  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
connections.  
LINDY CPU Switch Smart  
Installation and Use  
Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F1 - Display firmware first digit (Note: F1 is ) followed by NOT O)  
F2 - Display firmware second digit  
F3 - Display firmware third digit  
F5 - Restore PS/2 mouse function to the currently selected CPUs mouse port  
F6 - Restore IntelliMouse function to the currently selected CPUs mouse port  
F8 - Reset all configurations to factory default settings. An rwill show briefly on the  
display to confirm that the reset has been completed.  
4.7 Setting a security password  
There are many situations where unrestricted access to corporate file servers or  
sensitive information needs to be controlled. In such circumstances, the LINDY CPU  
Switch Smart can be locked away in a room or secure cabinet and controlled  
remotely. In this mode typing the keyboard hotkeys together with 'L' will blank the  
screen, disconnect the keyboard and mouse from all of the computers and display  
Pon the LINDY CPU Switch Smart display. Control can only be regained by typing  
the correct password on the keyboard.  
To set the password in configure mode, first type Pthen (return). The display on  
LINDY CPU Switch Smart will change to show =' and you can then type your  
password. The password is not case sensitive and can be any combination of key  
strokes, including the function keys, but excluding the (ctrl), (alt), (shift) and (return)  
keys. When you have typed in your password type (return) to register it in the stored  
memory. Do not worry if you type the password incorrectly, you can always re-enter  
configure mode and set the password again. If you have lost the password and the  
LINDY CPU Switch Smart is locked, the unit may be unlocked by powering down the  
LINDY CPU Switch Smart, entering configure mode at power on (see section 2.6),  
and performing a complete reset using the F8 function.  
NOTE - The password consists of a combination of key strokes rather like the code  
to a safe. The key strokes are not case sensitive and can include all the keys on the  
keyboard (except ctrl, alt, shift and enter). Consequently the following 'password'  
would be valid:  
J
R)5('  
LINDY CPU Switch Smart  
Installation and Use  
Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.8 Cascade query code  
The LINDY CPU Switch Smarts use a special query codeto detect whether or not  
they are connected to another LINDY CPU Switch Smart. By default your LINDY  
CPU Switch Smart uses query code AD. LINDY CPU Switch Junior OSD (another  
range of keyboard / mouse / video switches from LINDY Technology) units with  
firmware versions less than 1.09 used query code EF. This was found to conflict  
with a small number of other (rare) devices that used the same query code so an  
alternative query code was provided to ensure compatibility. Either query code may  
be used but you should make sure that all cascaded LINDY CPU Switch Smart and  
LINDY CPU Switch Junior OSD units are set to use the same query code. If any of  
the cascaded LINDY CPU Switch Junior OSDs have firmware versions less than  
1.09 then the cascade query code for all the LINDY CPU Switch Smarts and LINDY  
CPU Switch Junior OSDs should be set to EF.  
L7 Cascade query code = AD (default)  
L8 Cascade query code = EF  
4.9 Resolving slow mouse problems  
Due to certain technical reasons some systems running particular combinations of  
operating system and mouse drivers are sensitive to small timing changes relating  
to mouse communications. The introduction of a switch like the LINDY CPU Switch  
Smart inevitably causes some timing changes and in rare cases interactions have  
been observed that causes the mouse to run very slowly. Certain HP Vectra  
computers running later versions of Windows NT with Logitech mouse drivers and  
Logitech mice have been observed to exhibit such interactions with older switches.  
One solution to this problem is to change the mouse driver.  
The LINDY CPU Switch Smart is a high performance device that is carefully  
engineered to minimise such interactions and should not exhibit this characteristic.  
Nevertheless such interactions are unpredictable and so the LINDY CPU Switch  
Smart is fitted with a feature that ensures that the mouse can never operate at a  
very slow rate regardless of such interactions. This feature is activated using the  
following options:  
L5 Allow the mouse to run at any speed (default)  
L6 Don't allow the mouse to run at very slow speeds  
LINDY CPU Switch Smart  
Installation and Use  
Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LINDY CPU Switch Smart  
Installation and Use  
Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.10 Exit configure mode  
When you have finished configuring any special options, simply type Efollowed by  
(return) to exit configure mode and return to normal operation mode. The attached  
computers can now be switched on.  
LINDY CPU Switch Smart  
Installation and Use  
Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A. Cable and connector  
specifications  
IMPORTANT NOTE  
The maximum cable lengths supported vary widely between devices and  
cables. It may be possible to use cables that are longer than those specified  
below with certain PCs and peripherals but this cannot be guaranteed. If you  
experience problems try using shorter cables.  
A1. Keyboard, monitor and mouse to LINDY CPU Switch Smart  
All of the shared devices plug directly into the relevant ports at the rear of the LINDY  
CPU Switch Smart. If you use an AT style keyboard you will need an AT (5 pin DIN  
female) to PS/2 (6 pin mini-DIN male) converter.  
Cable specification (self-powered operation):  
Keyboard, monitor and mouse cables should be no longer than 2 metres.  
Cable specification (with optional power adapter):  
Keyboard, monitor and mouse extension cables can be used to increase the  
distance from LINDY CPU Switch Smart up to 10m. Most keyboards and mice will  
also operate at distances of 20 metres.  
A2. LINDY CPU Switch Smart to PCs 1 to 4  
Cable specifications:  
Video - 15 pin high density male D connector to 15 pin high density male D  
connector wired as a standard VGA PC to monitor cable. There are two types  
commonly available. The best type cables which will give excellent quality are  
constructed with coaxial cable cores. Cheaper datacables are often used, but can  
degrade video quality if used over longer distances. Avoid using 'data' cables longer  
than 2 metres unless the video quality is not important. Good quality coaxial video  
cables may be run at distances up to 30 metres with little loss of video quality. If you  
wish to make use of the DDC (Display Data Channel) capabilities of the LINDY CPU  
Switch Smart then you will need to use cables that have the DDC signalling lines  
connected (pins 12 and 15 on the 15-way video connector). Not all video cables  
LINDY CPU Switch Smart  
Installation and Use  
Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
have these DDC lines connected.  
Keyboard and PS/2 mice - 6 pin mini-DIN male connector to 6 pin mini-DIN male  
connector with all lines connected straight through (1-1,2-2 etc.). If the PC has a 5-  
pin DIN AT style keyboard connector you will need a PS/2 to AT keyboard adapter  
6-pin mini-DIN female to 5-pin DIN male (readily available). For interface powered’  
operation without the optional power adapter the cables should be no longer than 5  
metres (see section 2.4 for more details). For operation with the power adapter,  
cables should be no longer than 30 metres.  
RS232 serial mice - these require a special converter to connect the RS232 lines  
present on the LINDY CPU Switch Smart mouse ports to the RS232 port on a PC.  
Cables should be no longer than 30 metres.  
NOTE - There are several common wiring specifications for 6-pin mini-DIN to  
9-pin serial adapters. If you have an adapter that has been supplied with a  
mouse it may have a completely different internal wiring to that shown above  
and may not be compatible with the LINDY CPU Switch Smart  
LINDY CPU Switch Smart  
Installation and Use  
Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recommended cables:  
3-in-1 keyboard, video and mouse combination cable - For convenience,  
neatness and high video quality we recommend the LINDY brand 3-in-1 combination  
cables. These cables are constructed with tri-coax video links to ensure that high  
video quality is maintained. They also support DDC signalling and are colour coded  
in PC99 specification colours for your convenience. These match the colours used  
on the back of your LINDY CPU Switch Smart and most modern PCs. These cables  
are available in various different lengths to suit your requirements. They may be  
purchased with or without the adapters for AT keyboards and RS232 serial mice.  
Please quote the following part codes when ordering from your supplier.  
Part Code  
33701  
Description  
3-in-1 LINDY cable, 1 metres long  
3-in-1 LINDY cable, 2 metres long  
3-in-1 LINDY cable, 3 metres long  
3-in-1 LINDY cable, 5 metres long  
3-in-1 LINDY cable, 10 metres long *  
33702  
33703  
33704  
33706  
* The optional power adapter may be required (see section 2.4).  
A3. Options port pin assignments  
The 15 way D connector located on the back of the LINDY CPU Switch Smart  
(labelled OPTIONS / FLASH) provides connections for the remote control module  
and allows an external RS232 device to control the LINDY CPU Switch Smart. See  
section 3.6 for more details.  
Pin 9 = GND  
Pin 10 = TXD  
Pin 11 = RXD  
Other pins to be left unconnected  
LINDY CPU Switch Smart  
Installation and Use  
Page 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A.4 Flash upgrade cable connection  
The cable connections shown below are to connect either COM1 or COM2 of a PC  
to the LINDY CPU Switch Smart to allow flash upgrades.  
A.5 RS232 synchronisation cable pin assignments  
The cable connections shown below are to connect two LINDY CPU Switch Smarts  
together for synchronised operation (see section 3.8)  
LINDY CPU Switch Smart  
Installation and Use  
Page 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B. Problem Solving  
Problem: Poor video quality with smearing fuzziness or ripple.  
Action: Use screened coaxial video cables to connect your devices.  
Problem: Mouse does not move cursor on screen.  
Action: Ensure that the mouse and computer are both connected to LINDY CPU Switch  
Smart before power is connected and ensure that the LINDY CPU Switch Smart is powered  
on before the attached computer. Ensure that your software is configured to accept a  
Microsoft compatible mouse of the type that you have connected (PS/2 or RS232). If you  
move the mouse and the activity indicator (dot on 7 segment display) does not flash then  
the LINDY CPU Switch Smart is not receiving data from the mouse. Check the mouse  
connection to the LINDY CPU Switch Smart, try resetting the mouse using the reset  
function (section 2.10) or re-powering the CPU Switch Smart. If you are attempting to  
connect the CPU Switch Smart to a CPU with a PS/2 mouse connection that has not been  
powered down then you will need to use the mouse restoration functions F5 or F6 (see  
section 2.11).  
Problem: Keyboard does not function or functions intermittently. Num lock light does not  
always come on when the num lock key is pressed.  
Action: Some older keyboards were designed for use with specific computers and are not  
truly AT or PS/2 compatible. These are not common but if you experience problems try  
another keyboard.  
Problem: Mouse causes channel to change.  
Action: Some cheaper mice are not fully compatible with the LINDY CPU Switch Smart and  
can lose data causing the channel to be changed (if mouse switching of channels is  
enabled). If you experience this problem then change the mouse and use a Microsoft,  
Logitech, IBM, Compaq or Hewlett-Packard type. Ensure that you are using a Microsoft  
compatible mouse driver on your PC. Some other manufacturersdrivers may switch the  
mouse to use a proprietary mouse data format not supported by the LINDY CPU Switch  
Smart. If you have unplugged and re-connected a mouse to the LINDY CPU Switch Smart  
then ensure that you reset it using the mouse reset function (see section 2.10).  
Problem: Mouse jumps around the screen after disconnecting the mouse cable or  
powering down the LINDY CPU Switch Smart.  
Action: If you have disconnected and re-connected a CPU mouse cable or you have  
powered down the LINDY CPU Switch Smart then the mouse data format may be out of  
synchronisation with that required by the PC (PS/2 or Intellimouse). Try the restore  
Intellimousefunction (F6) to resolve the problem or re-power the CPU.  
Problem: Mouse moves very slowly but otherwise functions correctly.  
LINDY CPU Switch Smart  
Installation and Use  
Page 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Action: Change the mouse driver to a Microsoft mouse driver or take the action  
recommended in section 4.9 of this manual.  
LINDY CPU Switch Smart  
Installation and Use  
Page 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Snow Blower RBT3584 User Manual
Lexmark All in One Printer 28S1855 User Manual
Lincoln Electric Welding System K1308 11 User Manual
Lindy Switch 42904 User Manual
LOREX Technology Switch BNC RCA User Manual
Majestic Appliances Electric Heater 3095 User Manual
Marantz Stereo Amplifier 646 032 User Manual
Maytag Clothes Dryer W10267633A User Manual
Melissa Fryer 643 069 User Manual
Meyer Sound Speaker System 500A Series User Manual