Lightolier Work Light IS_26556MCY User Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE  
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  
To assure full compliance with local codes and regulations, check with your local electrical inspector before  
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.  
Retain these instructions for maintenance reference.  
INSTRUCTION SHEET NO.  
IS:26556MCY  
0798  
Page 1 of 2  
CAUTION:  
• Turn off power at fuse box before installing fixture.  
• Fixture temperature is extremely high during operation. Use heat  
resident gloves or other heat resistant materials to protect hands  
when adjusting or handling the fixture during operation.  
J-BOX  
• Do not install fixture near combustible materials.  
• Fixture is not for residential use.  
WHITE WIRES  
(Neutral)  
8-32 STUD  
• Electrical supply to fixture must be 120 volts. Electrical supply  
can be AC or DC.  
BLACK WIRES (Hot)  
CANOPY  
• Do not mount fixture on a wall.  
GROUND WIRES  
INSTRUCTIONS FOR ATTACHING FIXTURE TO J-BOX (Fig. 1)  
CAP SCREW  
CANOPY is designed for a 4” octagon OUTLET BOX. FIXTURE can  
mount to different OUTLET BOXES as long as box mounting holes  
are on 3.5” centers and FIXTURE CANOPY covers box completely.  
Box mounting holes should be tapped with 8-32 thread.  
Fig. 1  
1. Thread 8-32 STUDS into J-BOX. STUDS should extend from  
J-BOX at least one inch.  
2. WHILE SUPPORTING FIXTURE, MAKE CONNECTIONS: BLACK  
FIXTURE LEAD to HOT (BLACK) SUPPLY LEAD; WHITE FIXTURE  
LEAD to NEUTRAL (WHITE) SUPPLY LEAD. UNINSULATED  
FIXTURE WIRE is a ground and must be connected to GROUND  
TERMINAL or GROUND LEAD inside OUTLET BOX. Use WIRE  
NUTS (local hardware item). Push connections back into  
OUTLET BOX.  
J-BOX  
3. Push CANOPY against ceiling passing STUDS through holes  
in CANOPY. Make sure wires are not pinched.  
SWITCH  
4. Thread 2 CAP SCREWS onto STUDS. Drive CAP SCREWS  
until CANOPY is tight against the ceiling.  
LAMP TERMINAL  
SPADE TERMINAL  
CAUTION: CAP SCREWS must be completely threaded onto  
the STUDS.  
NOTE: The proper LAMP should be installed into the FIXTURE  
prior to energizing. See instructions below.  
ACCESS KNOB  
RING NOTCH  
LAMPING & USING ACCESSORIES (Fig. 2)  
The following lamps may be used in the FIXTURE:  
LAMP ALIGNMENT  
BRACKET  
Fixture Cat. No. 26556M, WHCY, BKCY  
Lamp  
12 Volt PAR 56 Screw Terminal  
120 to 240 Watt  
LAMP SPRING  
1. Holding SNOOT loosen ACCESS KNOB a few turns until  
SNOOT opens.  
2. Screw SPADE TERMINALS into LAMP TERMINALS.  
3. Align 3 LAMP BOSSES with 3 RING NOTCHES. Align LAMP  
SCREW TERMINALS with LAMP ALIGNMENT BRACKET.  
Push LAMP into FIXTURE until LAMP SPRINGS hold LAMP.  
NOTE: The 3 LAMP BOSSES must sit in the 3 RING NOTCHES  
after the LAMP is installed.  
LAMP BOSS  
SNOOT  
Fig. 2  
4. Removing LAMP: Snap LAMP out of LAMPSPRINGS. Unscrew  
LAMP TERMINALS.  
LIGHTOLIER a GENLYTE company.  
631 Airport Road, Fall River, MA 02720  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KTM Motorcycle 3CF6001G6EN User Manual
Lenovo Computer Hardware X301 User Manual
Lenoxx Electronics Telephone PH 301 User Manual
Liebert Power Supply GXT User Manual
Lincoln Electric Welder SVM148 B User Manual
LOREX Technology Security Camera CVC6997 User Manual
Makita Drill HP1500 User Manual
Marantz DVD Player DV8300 User Manual
Matrox Electronic Systems Computer Hardware 4SIGHT M User Manual
McCulloch Brush Cutter 115154526 User Manual