ProSpec® Track Lighting System 26890
Page 1 of 1
ProSpec® Recessed Flangeless Monopoint
6
A
A
5
10 1/4
[259.7]
3 3/8
[85.7]
4 1/4
3 7/16
[108.2]
[86.6]
SECTION A-A
9 9/16
[242.9]
2
7 1/16
[179.4]
5 9/16
[141.6]
3 13/16
[97.3]
1.33
1
Ordering Information
Catalog No.
26890WH
26890BK
Finish
Matte White
Matte Black
Mounting
Intended for recessing into drywall type ceilings with
plaster skim coat. Accommodates ceiling thicknesses
of 1/2" to 3/4".
Compatibility
ProSpec track luminaires, 500W Max. NOT
FOR USE with ProSpec PAR56 or PAR64 track
mounted units.
Features
Labels
1. ProSpec Track Strip: Structural aluminum extrusion; average wall
thickness 0.08".
cULus
2. Mounting Frame: .012" thick galvanized corner bead. Allows for finished
plaster edge.
3. Insulated Liner: 0.040 wall high temperature extruded thermoplastic.
4. Conductors: “U” shaped copper conductor; increases contact surface and
minimizes contact resistance; provides reliable positive connection.
5. Mounting Brackets: 18 ga. galvanized steel. Adjustable to accommodate
1/2" to 3/4" ceiling thicknesses.
Job Information
Type:
6. Knockouts: Allows power feed from above using 3/8" or 1/2" (trade size)
connector (by others).
Job Name:
Cat. No.:
Finish
All painted finishes are baked enamel.
Electrical
Lamp(s):
Notes:
(2) circuits. Each circuit is 120V, 60 Hz. Each circuit has dedicated neutral for
maximum control flexibility. Track is continuously grounded throughout. Electrical
conductors are concealed in an insulated liner in the track. Intended for wiring
to branch circuit building wire with ground, in accordance with national and
local codes.
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0505