Lytecaster Recessed Downlighting 1104F13ES
®
Page 1 of 1 6 3/4" Aperture 0 1 Lt 13W Quad/Triple Tube Compact Fluorescent IC Frame-In Kit
6
5
7
3
7 5/16"
OVERALL
WIDTH
7 1/2"
OVERALL
HEIGHT
1
13" MIN.
24" MAX.
10 3/4"
OVERALL
LENGTH
4
7"
APERATURE
2
Ceiling Opening 7" diameter
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Voltage
120V
Lamp
Enclosed
Wall
Cross
Blade
Diffusers
Washer
AnodizedReflector AnodizedCone
Satin Cone
Baffles
Basic White
13W
1143
1112
1108
1105
1171
1121
1185
1132**
1104F13ES
1104F13ESN
Quad or 1144
1112NM
1113
1108NM
1110
1110NM
1105BNM 1170M1
1105NM
1105WH
1176
1176WH
1124
1126
1128**
1134
1177SH
1177LX**
1178SH
1178LX**
1190
1186
1186WH
1135
Triple
Tube
1144CD
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH
1135WH
1179M1
1179WH
Features
Electrical (cont.)
Max THD %: 10
Min Start Temp: 0˚F/ -18˚C
1. Housing: .032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal® housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Mounting Frame: .048” (#18 ga.) galvanized steel. Locks into position along
length of mounting bars with locking spring and bendable slot. (3) slots 90°
apart simplify alignment.
Options & Accessories
AirSeal® Kit: LAS56 (Optional)
Note: Use only if factory installed tape or knockouts are removed from vertical
adjustment slots in housing wall.
Labels
UL (Type IC Suitable for Damp Locations)
3. Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for branch circuit wiring supplying connected luminaires. Integral
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex®
cable without tools or additional connectors.
4. Mounting Bars:. .059" (#16 ga.) galvanized steel. Bars pivot for easy
attachment and wire-in below ceiling line. Bars extend to accommodate
16" to 24" O.C. joist spacing. Bars can accommodate 9" O.C. joist spacing
after a slight field modification (see Instruction Sheet). Features integral
self-tapping phillips screws or nails for secure attachment to wood or metal
construction. Attaches to T-bar ceilings without the need of accessories.
5. Socket Housing: Trim retaining spring secures trim to any height on
housing wall.
Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code.
Romex® is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
6. Socket: (4 Pin, GX24q-1) base, molded thermo-plastic. Pre-wired with #18
AWG leads to junction box.
7. Ballast: Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star® qualified.
Electrical
Input Watts: 16
Amps: .13
**Use Triple Tube Lamp Only.
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • C0906
Ballast Factor: 1.0
Power Factor: .96
Download from Www.Somanuals.com. All Manuals Search And Download.
|