LifeSource Thermometer DT 605 User Manual

SPECIAL PRO DUCT FEATURES  
O RAL USE  
HO W TO TAKE TEMPERATURE  
Reads temperature in Fahrenheit or Celsius.  
Beeps when peak temperature is reached.  
Nite Glow” feature for easy nighttime reading.  
Thermometer is water resistant, but not 100% water proof. Do not  
submerge unit in any liquid.  
Convenient memory feature: automatic recall of last temperature reading.  
Easy-to-read Jumbo display.  
Long-life, replaceable battery (approximately 1,500 temperatures).  
Low Battery Indicator .  
Auto-Off in approximately 10 minutes.  
Oral, rectal or underarm use.  
Includes 5 free probe covers.  
Do not drink hot or cold fluids, exercise, smoke or  
perform other activities that raise or lower temperature.  
The mouth should remain closed up to 5 minutes  
before attempting a reading.  
Place the probe tip well under the tongue in locations  
as indicated by the ” (see figure on right). Instruct  
children not to bite down on the thermometer.  
1. Place a probe cover carefully over the tip  
(see figure on right). Select oral, underarm  
or rectal as your measurement site (see  
following instructions).  
Ju m b o N ig h t Glo w Dig ita l Th e rm o m e te r  
2. Firmly push the START button. The thermometer will beep and the  
display will read: “188.8°FM”. This is a function check indicating the  
unit is working properly. If a previous reading is stored in memory,  
the thermometer will display the last temperature for three seconds.  
The night-glow feature automatically lights up when the thermometer  
is turned on.  
3. The °F or °C symbol will flash when the unit is ready to measure  
temperature. “ ” indicates a low battery. Replace battery (see  
“Changing the Battery” section) for accurate measurement. An “ERR”  
message in the window indicates your unit is not functioning proper-  
ly. Ensure that the batteries are installed correctly and review instruc-  
tions for proper operation.  
4. When peak temperature is reached, the °F or °C symbol will stop  
flashing, and the thermometer will beep repeatedly. It is not necessary  
to hear the beep to ensure the peak temperature has been reached.  
When the °F or °C symbol stops flashing and the display reads a  
consistent temperature, the peak temperature has been reached.  
5. Read and record the temperature and time for reference. The reading  
will automatically be stored in the memory until another reading is  
taken or the batteries are removed from the thermometer.  
6. Push the START button to turn the unit off. If you do not turn the  
unit off, it will shut off automatically in approximately 10 minutes.  
Jumbo back-lit display for easy nighttime reading  
BATTERY COVER  
DISPLAY WINDOW  
MEASURING SENSOR  
Approximate measuring time is 30 seconds. Opening of mouth or  
improper placement of the probe tip can result in longer read time.  
UN DERARM (AXILLARY) USE  
From a medical point of view, this method will  
always give an inaccurate reading and should not be  
used if a precise measurement is required.  
Wipe underarm with a dry towel.  
Place probe tip in armpit and bring arm down against  
the body. The probe should be pointing upward parallel to the arm.  
Approximate measuring time is 30 seconds or longer depending on  
placement of the probe and closure of the arm against the body.  
START BUTTON  
(DT-605)  
HO W TO CARE FO R THIS PRO DUCT  
Congratulations on your purchase of the LifeSource Jumbo Night Glow  
Digital Thermometer. Please read the instructions carefully to ensure  
accurate temperatures and safe operation. When used properly, this high  
quality product will give you years of accurate, dependable service.  
Use of probe covers is recommended to help avoid spreading germs, and  
to keep the thermometer clean. The thermometer should be cleaned  
after every use even when probe covers are used.  
Clean the thermometer using isopropyl alcohol or soap and water. Do  
not submerge unit in water. Do not boil the thermometer.  
SAFETY IN FO RMATIO N  
Store the unit in the protective case while not in use.  
High, prolonged fever requires medical attention especially for young children. In  
case of high readings, please contact your physician.  
Do not allow children to take their temperature unattended.  
Read the enclosed instructions carefully to ensure accurate temperature readings.  
Do not allow children to walk or run while taking temperature.  
The probe could present a hazard.  
Never boil the thermometer.  
Do not open the thermometer except to replace the battery.  
Keep battery away from children.  
Do not store or keep in direct sunlight or in high temperatures.  
Do not drop the thermometer, as this may damage the unit.  
Do not attempt to disassemble the unit except to replace the battery.  
RECTAL USE  
Commonly used for babies, young children or when it is difficult to  
take an oral or underarm temperature.  
After placing the probe cover on the thermometer, lubricate with a  
W HAT IS A “ N O RMAL TEMPERATURE?  
water-soluble lubricant.  
Gently insert the probe tip no more than  
Temperature readings vary among individuals. A normal temperature refers  
to each individuals average temperature while they are well. Normal aver-  
age temperatures range from 97°F/36.1°C to 100°F/37.7°C when taken  
orally. Oral, underarm, and rectal temperatures vary by approximately 1°F  
(0.5°C). A rectal temperature is considered your real or “core” body tem-  
perature. A rectal temperature is 1°F/0.5°C higher than an oral reading and  
an underarm temperature is 1°F/0.5°C lower than an oral reading.  
1
/
inch or 1.3cm into the  
2
rectum. Do not force the tip into the rectum if resistance is encountered.  
Dispose of the used probe cover and wash the thermometer as recom-  
mended.  
Approximate measuring time is 30 seconds.  
SPECIFICATIO N S  
RANGE:  
TO RECALL THE LAST TEMPERATURE  
PRECAUTIO N S  
Do not drop unit or subject to shock.  
Do not soak the thermometer in water.  
Do not boil the probe. Clean the probe with isopropyl alcohol.  
Do not use solvents or thinners on the unit.  
Do not store the unit in direct sunlight or at high temperature.  
Do not attempt to disassemble the unit except to replace the battery.  
CHAN GIN G THE BATTERY  
1.Press the START button while turning on the unit. The last measured  
temperature will be shown in the display with the letter M” shown  
under the degree sign for approximately 3 seconds.  
2.The thermometer will be in ready-to-measure” mode and the recalled  
temperature will be erased. Note: If the device is switched off before  
completion of temperature, the thermometer automatically goes to  
ready-to-measure” mode.  
When the “ ” appears in the lower right of the  
display, the battery is exhausted and needs replacing.  
Make sure you use the same type of battery and  
proceed as follows: Remove battery cover. Use a small  
screwdriver or a straight pin to remove  
battery. Insert new equivalent battery type (1.55V,  
SR41). Ensure battery is correctly positioned with the  
“+” facing up. Carefully replace the battery  
cover. Properly dispose of the battery, keeping it from  
small children and heat.  
32.0°C - 43.9°C  
89.6°F - 109.9° F  
ACCURACY:  
± 0.1°C between 35.0° and 40.0°C, ± 0.2°C under 35.0° or over 40°C  
± 0.2°F between 96.0° and 104.2°F, ± 0.4°F under 96.0° or over 104.2°F  
At standard room temperature between 18.0-28.0° C (64.4-82.4° F)  
WARRAN TY  
DISPLAY:  
Liquid Crystal display 3.5 digits  
CLEAN IN G AN D DISIN FECTIN G  
A&D Medical warrants to the first retail purchaser that this digital ther-  
mometer is free from defects in material and workmanship for the lifetime  
of the original owner. This warranty does not cover batteries or damage  
resulting from improper handling or use. To obtain replacement product,  
please return the product, freight and insurance pre-paid, together with  
proof of purchase and applicable shipping costs to A&D Medical at the  
address below. Canadian residents can return the product to Auto Control  
Medical. Call us toll-free at 1-888-726-9966 for shipping costs and further  
information (in Canada, call 1-800-463-5414). At A&D Medicals option,  
the product will be replaced with a new or refurbished product of equal  
value. THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLU-  
SIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. Some  
states may have laws which amend this warranty.  
After each use, clean the thermometer using isopropyl alcohol (70%) or  
soap and water. The thermometer is water resistant, but not 100% water-  
proof. Do not submerse the thermometer in any liquid.  
BATTERY:  
One 1.55V button size battery (SR41)  
SW ITCHIN G BETW EEN FAHREN HEIT & CELSIUS*  
1. Press and release the START button.  
2. Wait for display to read --- °C / --- °F (approx. 5 seconds) .  
3. Before °C/°F begins flashing, press the START button for three seconds.  
4. Unit will switch from °C and °F.  
5. When °C/°F symbol begins to flash, the thermometer is ready to take  
your temperature.  
POWER CONSUMPTION:  
Measurement mode: 0.1 mA  
Off: .001 mA  
Beeper: 0.15 mA  
Backlight: 5 mA  
BATTERY LIFE:  
Approximately 600 measurements  
DIMENSIONS:  
5.7” x 0.8” x 0.4” (14.5 cm x 2 cm x 1 cm)  
NOTE: The last reading is erased from memory when measurement  
mode is switched.  
In United States:  
A&D Medical  
In Canada:  
Auto Control Medical, Inc.  
6695 Millcreek Drive, Unit 5  
Mississauga, Ontario  
L5N 5R8  
WEIGHT:  
A division of A&D Engineering  
1555 McCandless Drive  
Milpitas, CA 95035  
Toll-free LifeSource Health Line 1-888-726-9966 1-800-463-5414  
www.LifeSourceOnline.com www.autocontrol.com  
Approximately 10 grams including battery  
FAST READ:  
Provides readings in approximately 30 seconds  
BEEPER:  
LifeSource is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved.  
Specifications subject to change without notice. Made in China  
U.S. Patent #6,419,388  
Beeps approximately 10 seconds after peak temperature is reached.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

LaCie Computer Drive Hard Disk Quadra User Manual
Leica Camcorder TPS1200 User Manual
Leica Laser Level 776748 User Manual
LG Electronics Microwave Oven LMVM2085SB User Manual
Mackie Portable Speaker SA1232 User Manual
Makita Air Compressor MAC8000 User Manual
Makita Power Screwdriver 6823 User Manual
Makita Trimmer UH5530 User Manual
Melissa Hot Beverage Maker 245064 User Manual
Memorex Portable CD Player MP3225 User Manual