Leviton Plumbing Product RZI6 1L User Manual

Single Pole (One location) or 3-Way (Multi-location)  
TMenabled products!  
Scene Capable Incandescent Dimmer  
Compatible with  
Cat. No. RZIØ6-1L, 600W (Lighted)  
120VAC, 60Hz  
DI-000-RZI06-00C  
INSTALLATION INSTRUCTIONS  
WARNINGS AND CAUTIONS:  
WARNINGS AND CAUTIONS:  
To be installed and/or used in accordance with appropriate electrical codes and regulations.  
If you are unsure about any part of these instructions, consult a qualified electrician.  
To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.  
Use with incandescent or 120V halogen fixtures only.  
Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ or Vizia™ RF remotes for multi-location dimming.  
Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 Vizia™ coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn the light on at the  
brightness level selected at the dimmer.  
Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).  
Total minimum load must exceed 40W.  
Dimmer may feel warm to the touch during normal operation.  
Recommended minimum wall box depth is 2-1/2”.  
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.  
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.  
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.  
Identifying your wiring application  
(most common):  
NOTE: If the wiring in the wall box does not resemble  
any of these configurations, consult a qualified  
electrician.  
Single-Pole Wiring Application:  
Changing the color of your Dimmer:  
Your Dimmer may include three color options. The Dimmer ships  
with the White frame attached. To change color of frame, proceed  
as follows:  
Step 2  
Step 4a  
Step 4b cont’d  
INTRODUCTION  
Coordinating Remote (no LEDS)  
Dimmer  
Leviton’s ViziaTM RF components are designed to communicate  
with each other via Radio Frequency (RF) to provide remote  
control of your lighting. Using RF technology allows Leviton  
to provide the greatest signal integrity possible. Each module  
in Leviton’s ViziaTM RF component line is a Z-WaveTM enabled  
device. In a Z-WaveTM network, each device is designed to act  
as a router. These routers will re-transmit the RF signal from  
one device to another until the intended device is reached. This  
ensures that the signal is received by its intended device by  
routing the signal around obstacles and radio dead spots. The  
Scene Capable Plug-in Lamp Dimming Module is compatible with  
any Z-Wave™ enabled network, regardless of the manufacturer  
and can also be used with other devices displaying the Z-Wave™  
logo.  
Do not use for  
incandescent  
Terminal  
Screw marked  
Black (Bk)  
hot (Black)  
Bk  
Bk  
1
3
Bk  
applications.  
2
Wh  
Black  
Single-Pole  
3-Way  
Green  
Ground  
Green  
Ground  
Terminal  
Screw marked  
Yellow/Red  
(YL/RD)  
RD  
D
/R  
L
Y
1. Line (Hot)  
2. Neutral  
3. Ground  
4. Load  
1. Line or Load  
(See important  
instruction  
below)  
4
YL/RD  
YL/RD  
Load  
Line  
120VAC, 60hz  
RD  
RD  
Terminal  
2
1
Screw marked  
Red (RD)  
2
1
White  
Terminal Label:  
Use terminal for 3-way or more applications only.  
2. Neutral  
3
4
5
Line up tabs  
and press in  
side to attach  
Push in  
side at tab  
to release  
For single pole applications do not remove this label.  
3
4
Neutral (White)  
3. Ground  
Dimmer  
4. First Traveler  
WIRING DIMMER:  
Connect wires per WIRING DIAGRAM as follows:  
NOTE: When using the coordinating remote without LEDs, the  
dimmer can be installed on either the Line or Load side of the  
3-way circuit.  
hot (Black)  
Bk  
– note color  
Installing Dimmer by itself or with other devices:  
5. Second Traveler  
Green  
Ground  
CAUTION:  
– note color  
If installing Dimmer in a single device application, proceed with the  
INSTALLING YOUR DIMMER section. If installing Dimmer in a  
multi-device application, proceed as follows:  
RD  
YL/RD  
Remember to exercise good common sense when using the  
Timer features of your remote, especially when scheduling  
unattended devices. There can be some unexpected  
IMPORTANT: For 3-Way applications, note that one of the screw  
terminals from the old switch being removed will usually be a  
different color (Black) or labeled Common. Tag that wire with  
electrical tape and identify as the common (Line or Load) in both the  
dimmer wall box and remote wall box.  
Black  
Load  
White  
Line  
120VAC, 60hz  
NOTE: Maximum wire length from dimmer to all installed remotes  
cannot exceed 300 ft.  
Use terminal for 3-way or  
more applications only.  
For single pole applications,  
do not remove this label.  
MULTI-DEVICE APPLICATION:  
In multi-dimmer installations, the reduction of the dimmer’s capacity  
is required. Refer to the chart for maximum load per dimmer.  
consequences if not used with care. For example, an empty  
coffee pot can be remotely turned on. If that should happen, your  
coffee pot could be damaged from overheating. If an electric  
heater is turned on by remote control while clothing is draped  
over it, a fire could result. DO NOT USE the remote for the control  
of high power heating appliances such as portable heaters. This  
device will not control lighting that is used with electronic low-  
voltage and high frequency power supply transformers, nor high  
pressure discharge lamps (HID lighting). This includes mercury-  
vapor, sodium vapor and metal halide lamps.  
Green or bare copper wire in wall box to Green terminal screw.  
Line Hot (common) wall box wire identified (tagged) when  
removing old switch to terminal screw marked “BK”.  
Neutral (White)  
Preparing and connecting wires:  
Step 3  
First Traveler wall box wire to terminal screw marked “RD”  
(note wire color). This traveler from the dimmer must go to  
the terminal screw on the remote marked “RD”.  
This dimmer can be wired using side wire terminal  
screws or through backwire openings. Choose  
appropriate wire stripping specifications accordingly.  
WIRING DIMMER:  
Connect wires per WIRING DIAGRAM as follows:  
Green or bare copper wire in wall box to Green terminal screw.  
Line Hot wall box wire to terminal screw marked “BK”.  
Load wall box wire to terminal screw marked “RD”.  
Dimmer terminal screw marked “YL/RD” should have Red  
insulation label affixed.  
NOTE: If insulating label is not affixed to terminal screw marked  
“YL/RD”, use electrical tape to cover.  
Proceed to Step 5.  
Remove Red insulating label from terminal screw marked  
“YL/RD”.  
Second Traveler wall box wire to terminal screw marked  
“YL/RD” (note wire color). This traveler from the dimmer must  
go to the terminal screw on the remote marked “YL/RD”.  
5/8”  
(1.6 cm)  
Strip Gage  
(measure bare wire  
here or use gage on  
back of the dimmer)  
FEATURES  
WIRING COORDINATING REMOTE:  
Connect wires per WIRING DIAGRAM as follows:  
NOTE: Maximum wire length from dimmer to last remote is 300ft.  
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE  
More than  
cut  
Soft fade ON/OFF  
Scene capable  
ON/OFF LED and Brightness level LED  
Two way communication  
RF reliability  
Ease of installation – No new wiring  
Compatible with other Z-Wave™ enabled devices  
No Neutral wire required  
(if necessary)  
Cat. No.  
Single  
Two Devices 2 Devices  
3-Way Wiring with Coordinating  
Dimming or Switching Remote (no LEDs)  
Application:  
Step 4b  
Green or bare copper wire in wall box to Green terminal screw.  
Load wall box wire identified (tagged) when removing old  
switch to terminal screw marked “BK”.  
RZIØ  
6
600W  
500W 400W  
INSTALLING YOUR DIMMER  
NOTE: Use check boxes when Steps are completed.  
(Coordinating Dimming Remote Depicted)  
First Traveler wall box wire (note color as above) to terminal  
screw marked “RD”. This traveler from the remote must go to  
the terminal screw on the dimmer marked “RD”.  
Second Traveler wall box wire (note color as above) to  
terminal screw marked “YL/RD”. This traveler from the remote  
must go to the terminal screw on the dimmer marked “YL/RD”.  
Cordinating Remote  
Dimmer  
Side Wire Connection  
Side wire terminals accept  
#14 AWG solid copper wire only.  
Back Wire (either hole may  
be used)  
Back wire openings use #14-12  
AWG solid copper wire only.  
WARNING: TO AVOID FIRE, ShOCk, OR DEATh;  
Step 1  
TURN OFF POWER at circuit breaker or fuse and test  
Bk  
that power is off before wiring!  
Bk  
Tools needed to install your Dimmer:  
1
1
Terminal  
Screw marked  
Black (Bk)  
2
2
Remote terminal screw marked “WH” should have White  
insulation label affixed.  
3
4
3
Slotted/Phillips Screwdriver  
Electrical Tape  
Pencil  
Make sure that the ends of the wires from the wall box are  
straight (cut if necessary).  
Remove insulation from each wire in the wall box as shown.  
/&&  
/&&  
/&&  
/&&  
/&&  
/&&  
/. /&&  
/. /&&  
/. /&&  
. /&&  
/&&  
/
/.  
/.  
/.  
/.  
/.  
/.  
RD  
D
/R  
L
Y
RD  
D
4
5
/R  
L
Y
Terminal  
Screw marked  
Yellow/Red  
(YL/RD)  
NOTE: If insulating label is not affixed to terminal screw  
marked “WH”, use electrical tape to cover.  
Pliers  
5
Cutters  
Ruler  
Terminal  
Screw marked  
Red (RD)  
Proceed to Step 5.  
For Single-Pole Application, go to Step 4a.  
For 3-Way Coordinating Remote (no LEDs) Application, go  
to Step 4b.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Leica Camera Lens 11081 User Manual
Lenovo Server RS210 User Manual
Little Wonder Lawn Mower LB601 00 01 User Manual
Magnat Audio Pager M3 LCD M4 LCD User Manual
Magnavox Flat Panel Television 42MF531D 37B User Manual
Makita Drill BDF460 User Manual
McIntosh Car Amplifier MCC302 User Manual
Memorex Telephone MPH692 User Manual
Micon Security Camera IP 220E User Manual
MicroBoards Technology CD Player CWR 424 52 User Manual