		 Acenti™ Wallplate Kit   
					INSTALLATION INSTRUCTIONS   
					If Alignment Plate Was Not Pre-Installed:   
					CAUTION: DO NOT over-tighten device mounting screws.   
					Over-tightening will cause improper mounting and alignment.   
					Using a high-torque power screwdriver is not recommended.   
					Alignment Plate must sit completely flush on wall surface.   
					WARNING: To be installed and/or used in accordance with   
					Step 3   
					appropriate electrical codes and regulations.   
					• 
					In order to relieve stress on device when mounting,   
					dress wall box wires with a bend (refer to Figure).   
					WARNING: If you are unsure about any part of these   
					instructions, consult a qualified electrician.   
					• 
					Carefully pass the wired Acenti device through the   
					Alignment Plate ensuring the tab is towards the   
					bottom.   
					For Multi-Gang Installations   
					NOTE: Refer to the individual Acenti™ device's instruction   
					sheet for complete wiring details.   
					For multi-gang installations, the alignment of the devices   
					installed is important. If necessary, adjust the space between   
					the paddles/faces to maintain a consistent gap of approximately   
					1/64" (0.4 mm). This can be done by gently tapping the strap of   
					the devices in the direction needed with a small screwdriver as   
					NOTE: For the purposes of illustration, this instruction sheet   
					will show the mounting of the Acenti Wallplate System using   
					the Acenti Switch. The mounting of the Acenti Wallplate System   
					will be the same for all Acenti devices.   
					• 
					Go to Step 4.   
					shown.   
					1/64" (0.4 mm)   
					NOTE: For wallplate installation only, go To Step 5.   
					INSTALLING ACENTI™ WALLPLATE KIT   
					Mounting Screw   
					Cut-Out (2 places)   
					WARNING: TO AVOID FIRE, SHOCK, OR DEATH;TURN   
					OFF POWER at circuit breaker or fuse and test that power is off!   
					Check Device And Alignment Plate:   
					Step 1   
					Alignment Plate   
					• 
					• 
					• 
					The installation of your Acenti device should now be   
					at the point where all your electrical connections are   
					complete and secure.   
					If the Alignment Plate was temporarily positioned   
					during the installation of Acenti device, go to   
					Step 2.   
					Tab   
					If the Alignment Plate was not used during the   
					installation of Acenti device, go to Step 3.   
					Device Mounting And Alignment:   
					Step 4   
					Wallplate Mounting:   
					Step 5   
					• 
					Ensure that cut-outs in alignment plate are   
					positioned such that the device mounting holes in   
					the wall box are accessible and tab is on bottom.   
					If Alignment Plate Was Pre-Installed:   
					Step 2   
					Wall Surface   
					• 
					In order to relieve stress on device when mounting,   
					dress wall box wires with a bend (refer to   
					Figure).   
					• 
					• 
					Begin to partially screw in device mounting screws   
					into wall box mounting holes.   
					Align the three tabs in the multi-function clips with   
					the alignment pins on the Alignment Plate and press   
					into place.   
					Continue mounting of device and Alignment Plate   
					by tightening the mounting screws until the strap sits   
					flush and just snug on Alignment Plate.   
					Reposition Alignment Plate for leveling if necessary.   
					Complete installation by lightly tightening mounting   
					screws until Alignment Plate sits flat on wall surface.   
					Mounting: With   
					"LEVITON" facing up   
					and notch facing down,   
					press Acenti™ wallplate   
					onto device until it   
					clicks flush to wall   
					surface.   
					Pin and alignment hole   
					engaged (2 Places)   
					TOP   
					TOP   
					• 
					• 
					Remove mounting screw or electrical tape that is   
					temporarily holding the Alignment Plate.   
					• 
					• 
					Go to Step 4.   
					Removal (if necessary):   
					Wallplate   
					Place a small   
					screwdriver in notch on   
					bottom of wallplate and   
					gently lift up to remove.   
					Notch   
					on   
					bottom   
					TOP   
					TOP   
					RESTORING POWER:   
					TOP   
					TOP   
					Restore power at circuit breaker or fuse. Installation is   
					complete.   
					P 
					P 
					TO   
					P 
					TO   
					P 
					TO   
					TO   
					For additional information, contact the   
					Acenti™ Information Hotline at 1-888-4-ACENTI   
					or visit Leviton's website at www.leviton.com/acenti   
					U.S. & Foreign Patents Pending   
					Copyright© 2004 Leviton Manufacturing Co., Inc.   
					All Rights Including Trade Dress Rights Reserved   
					Alignment pin into   
					alignment hole   
					with 3 tabs.   
					Strap must sit flat on   
					alignment plate.   
					PK-93603-10-03-0B   