Lenox Air Conditioner wb2 17 User Manual

HUMIDIFIER  
© 2003 Lennox Industries, Inc.  
Dallas, Texas USA  
504,882M  
12/2003  
®
HEALTHY CLIMATE HUMIDIFIERS  
INSTALLATION INSTRUCTIONS FOR LENNOX MODEL WB2-17 & WB2-17A  
Specifications  
ATTENTION INSTALLER:  
This product must be installed by a qualified heating and air conditioning contractor.  
This product must be installed in compliance with all local, state and federal codes.  
BYPASS HUMIDIFIER  
Model WB2-17 & WB2-17A  
!
WARNING  
Electrical Shock Hazard.  
• Unit dimensions  
Can cause injury or death.  
1
1
1
8
2
8
13 / "W x 15 / "H x 9 / "D,  
6" dia. round opening  
Disconnect all electrical power supplies before  
servicing.  
• Plenum Opening  
!
WARNING  
3
1
4
2
9 / "W x 12 / "H  
Risk of Property Damage, Injury or Death.  
Installation, adjustments, alterations, service and maintenance must be  
performed by your Lennox dealer.  
• Water Feed Rate  
6 gph  
!
WARNING  
• Electrical Data  
24V-60Hz, 0.5 AMP  
Risk of Scalding.  
Water temperature over 125ºF can cause severe burns and scalding instantly.  
Shut off the hot water supply before disconnecting or tapping into any hot  
water supply line.  
!
CAUTION  
Risk Of Sharp Edges Hazard.  
WB2-17A  
Equipment sharp edges can cause injuries.  
Avoid grasping equipment edges without protective gloves.  
For detailed humidifier control  
installation and wiring instructions  
see form Publication No. 504,879M  
included with humidifier.  
!
CAUTION  
Risk of Property and Equipment Damage.  
Water heating system can be damaged if water supply remains off.  
After humidifier installation is completed, turn hot water supply back on.  
Water heating system must be de-energized if the main water supply remains  
shut off.  
Do not set humidity level above recommended or to recommended level if  
condensation exists on inside windows of any unheated space, as condensation  
damage may result. Excess humidity can cause moisture accumulation which  
can allow the possibility for mold growth in your home.  
Do not install unit in location where freezing temperatures may occur. The water  
line could freeze and crack causing water damage to the home.  
Do not install humidifier or bypass connection on furnace jacket.  
Do not install humidifier or bypass connection on blanked off end of cooling coil  
where airflow will be restricted.  
Do not connect the transformer to multi-speed furnace blower motors or blower  
motors other than 120 VAC.  
Do not install humidifier where water pressures exceed 125 psi, since humidifier  
damage may result. Follow codes in effect concerning pressure reduction.  
Do not install power humidifier on supply plenum where static pressure exceeds  
0.3” w.c.  
TEMPLATE MUST BE LEVEL  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Leica Laser Level 6007282 User Manual
Lenovo Computer Hardware 41N3005 User Manual
Lenovo Computer Monitor L193 User Manual
Logitech Video Game Controller 940 000117 User Manual
Magnavox DVD Player DP170MGXF User Manual
Manitowoc Ice Ice Maker RF User Manual
Martin Audio Portable Speaker HTKW1 User Manual
Melissa Styling Iron 235 003 User Manual
Mellerware Carpet Cleaner 23810 User Manual
Memorex TV Converter Box MVCB1000 User Manual