Lennox Hearth Blower CI1500 User Manual

INSTALLATION  
INSTRUCTIONS  
BK-CI BLOWER KIT (CAT. NO. H0767)  
FOR MODELS – CI1500 AND CI2500 SERIES  
KIT CONTENTS:  
6. Locate the long black wire from the  
1 ea. Blower Assembly  
1 ea. Rheostat Assembly  
1 ea. Fan Disc with 1 ea. White Wire  
5 ea. Screws, #8 x ½”  
1 ea. Instruction Sheet  
blower assembly and pass the wire  
through the hole in the rear shroud. Stow  
the wires into the existing wire holders  
on the inside of the rear shroud (see  
Figure 6a & 6b).  
Remove 2  
bolts on  
each side of  
rear shroud.  
Shroud  
TOOLS REQUIRED:  
1/4” & 7/16” Nut Drivers or Sockets  
INSTALLATION INSTRUCTIONS:  
Pass wire  
1. The following instructions, 1 through 11  
are for units WITHOUT an Optional Full  
Function Flame Modulating Remote  
Control System, H0301 or H0302. If either  
of these kits have been purchased, follow  
instructions on Page 2 instead – See  
INSTALLATION INSTRUCTIONS for units  
WITH a Full Function Flame Modulating  
Remote Control.  
through  
hole  
Stow wires  
into holders  
Figure 3  
Long black  
wire from  
blower  
4. Using a ¼” nut driver install the fan disc  
with white wire onto the stove back  
(install with 2 existing screws as shown  
in Figure 4).  
Figure 6a  
Figure 6b  
7. Connect the remaining black wire from the  
blower to the bottom terminal on disc as  
shown in Figure 7.  
Using a 1/4” nut driver or socket, install  
the Blower Assembly, using the 3 screws  
provided, to the bottom of the rear  
shroud as shown in Figure 1.  
Install disc  
with wire  
Install blower using 3  
screws provided  
Connect the  
remaining wire  
from the blower  
to the fan disc  
Figure 4  
5. Pass the white wire from the fan disc  
through the hole in the rear shroud and  
connect it to the white rheostat wire (as  
shown in Figure 5).  
Figure 1  
2. Disconnect the 2 black wires from the on/off  
switch at the valve (from terminals TP/TH  
and TH). See Figures 2 & 10.  
.
White wire from disc  
Connect white wires  
Figure 7  
8. Slide the sleeves on the wires to cover the  
connectors on the fan disc as shown in  
Figure 8.  
Hole  
Disconnect 2  
black wires  
Shroud  
Figure 5  
Slide the sleeves  
on wires to cover  
connectors  
Important Note: Ensure that the wires and  
connectors are completely through the hole  
and contained in the rheostat housing.  
Figure 2  
3. Using a 7/16” nut driver or socket, remove  
the 4 bolts on the rear shroud as shown in  
Figure 3. Carefully lift off the shroud and  
turn it to the side (see Figure 4).  
Figure 8  
Lennox Hearth Products; 1110 West Taft Avenue; Orange, CA 92865  
Part #775146M Rev. A, 12/03, Page 1 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lenovo Laptop 27763CU User Manual
Lenoxx Electronics Cassette Player 9190M User Manual
Lifebreath Ventilation Hood 94 EXCHANGER User Manual
Lightolier Work Light C6E17OVW User Manual
LST Home Security System 246100 User Manual
Mackie Universal Remote DX RVC User Manual
Manitowoc Ice Ice Maker K00197 User Manual
Maximatic Food Saver EFD 1010 User Manual
Maytag Ventilation Hood ERV 150 User Manual
Melissa Iron 741 043 User Manual