xPico Wi-Fi
Embedded Device Server
User Guide
Part Number 900-691-R
Revision D February 2014
Download from Www.Somanuals.com. All Manuals Search And Download.
xPico® Wi-Fi® Embedded Device Server User Guide
4
Download from Www.Somanuals.com. All Manuals Search And Download.
xPico® Wi-Fi® Embedded Device Server User Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
xPico® Wi-Fi® Embedded Device Server User Guide
6
Download from Www.Somanuals.com. All Manuals Search And Download.
xPico® Wi-Fi® Embedded Device Server User Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
xPico® Wi-Fi® Embedded Device Server User Guide
10
Download from Www.Somanuals.com. All Manuals Search And Download.
1: Using This Guide
Purpose and Audience
This guide provides the information needed to configure, use, and update the xPico® Wi-Fi®
embedded device server. It is intended for software developers and system integrators who are
embedding this product into their designs.
Summary of Chapters
The remaining chapters in this guide include:
Chapter
Description
Main features of the product and the protocols it supports.
Includes technical specifications.
Instructions for accessing Web Manager and using it to configure
settings for the device.
Instructions for configuring network settings.
Instructions for configuring various interface settings.
Instructions for configuring tunnel settings.
Information about the Configurable Pin Manager (CPM) and how
to set the configurable pins to work with a device.
Instructions for configuring HTTP settings.
Instructions to maintain the xPico Wi-Fi, view statistics, files, and
diagnose problems.
Provides additional information on security settings available.
Instructions for configuring monitor settings.
Instructions for branding the Web Manager user interface.
Instructions for obtaining the latest firmware and updating the
xPico Wi-Fi.
Information on configuring settings using XML or the command
line interface.
Instructions for viewing status information and configuring a unit
through HTTP request.
Instructions for contacting Lantronix Technical Support.
Lantronix compliance information.
Instructions for converting binary values to hexadecimals.
xPico® Wi-Fi® Embedded Device Server User Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
1: Using This Guide
Additional Documentation
Visit the Lantronix Web site at www.lantronix.com/support/documentation for the latest
documentation and the following additional documentation.
Document
Description
xPico Wi-Fi Embedded Device
Server Integration Guide
Information about the xPico Wi-Fi hardware, testing the device server
using the demonstration board, and integrating the unit into your
product.
xPico Wi-Fi Evaluation Kit
Embedded Device Server Quick
Start Guide
Instructions for getting the xPico Wi-Fi unit up and running.
xPico Wi-Fi Evaluation Kit
Embedded Device Server User
Guide
Information needed to use the xPico Wi-Fi embedded device serer on
the evaluation board.
xPico® Wi-Fi® Embedded Device Server User Guide
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2: Introduction
This chapter summarizes the basic information and features of the xPico Wi-Fi embedded device
server.
Key Features
Wireless LAN Interface:
-
-
-
-
-
-
-
-
IEEE 802.11 b/g and IEEE 802.11n (single stream)
WLAN interface (2.4 GHz only)
IEEE 802.11 d/h/i/j/k/w/r
IEEE 802.11i Support - WEP(Client only), WPA-Personal, WPA2-Personal
u.FL connector for external antenna
Soft Access Point with DHCP Server
Simultaneous SoftAP and Client
Roaming: continually tracks Wi-Fi signal strength within range, resulting in smooth and
automatic transition between access points without delay.
-
QuickConnect: Dynamic Profiles facilitate easy and rapid connections to access points
Host Interface:
-
Serial Interface
Two Serial CMOS Ports 1200 to 921.6 Kbps
Flow control: XON/XOFF, RTS/CTS (Line 1 only)
Lantronix tunneling application
Modem Emulation Mode
-
-
SPI Interface
Configurable slave/master SPI interface that can be clocked at 30MHz.
USB Interface 2.0 (device)
USB2.0 (12 Mbps) Full Speed Device port interfaces for connection to an upstream USB
device.
Support for USB CDC Serial profile (Future Release, contact Lantronix for more
information).
-
GPIO Interface
8 configurable general purpose Input/Output pins
Custom pin manager
Network Protocols: TCP/IP, UDP/IP, DHCP Server (software-enabled Access Point
interface), ARP, ICMP, DHCP Client (WLAN interface), Auto-IP, DNS, HTTP
Management and Control:
-
Web Server
xPico® Wi-Fi® Embedded Device Server User Guide
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2: Introduction
-
-
-
-
-
-
-
CLI (Serial Monitor Port)
XML Configuration Import and Export (XCR, XML Status Export [XSR])
WebAPI
Field upgradable firmware (OTA)
Power Management Framework
OEM Support Kit
Simple Customization and device configuration management
Security:
-
256-bit AES encryption
Architecture:
-
-
-
-
ARM Cortex-M3 class processor with on-chip Flash and SRAM
1 MB Flash and 128KB SRAM
SPI Flash 1 MB
Zero Host Load Driver
Physical Interface: 40-pin Board-to-Board SMT Connector
Certifications: FCC, IC, EU, Japan, UL, CE
Warranty: 5-Year Limited
Protocol Support
The xPico Wi-Fi embedded device server contains a full-featured IP stack. Supported protocols
include:
IEEE 802.11 b/g and IEEE 802.11n (single stream) WLAN interface (2.4 GHz only)
802.11i - WPA-Personal, WPA2-Personal
Soft-AP with DHCP Server
HTTP Server
TCP/IP, UDP/IP, DHCP Server (Software enabled Access Point interface), ARP, ICMP, DHCP
Client (WLAN interface), Auto-IP, DNS
Troubleshooting Capabilities
The xPico Wi-Fi device offers the abilty to view Trouble Log messages (see Line Settings on page
30).
xPico® Wi-Fi® Embedded Device Server User Guide
14
Download from Www.Somanuals.com. All Manuals Search And Download.
2: Introduction
Configuration Methods
After installation, the xPico Wi-Fi embedded device server requires configuration. For the unit to
operate correctly on a network, it must have a unique IP address on the network. These methods
may be used for logging into the xPico Wi-Fi and assigning IP addresses and other configurable
settings:
Web Manager: View and configure settings easily through a web browser using the Lantronix
XML: The xPico Wi-Fi supports XML import and XML export through a terminal emulator
Command Mode: Access the Command Mode (CLI) by connecting a PC or other host
Addresses and Port Numbers
Hardware Address
The hardware address is also referred to as the physical address or MAC address. Sample
hardware address:
00-80-A3-FF-FF-FF
00:80:A3:FF:FF:FF
IP Address
Every device connected to an IP network must have a unique IPv4 address. This address
references the specific unit.
Port Numbers
TCP Port 80: HTTP Server (Web Manager configuration)
TCP Port 10001: Tunnel (Line 1)
TCP Port 10002: Tunnel (Line 2)
Product Information Label
The product information label on the unit contains the following information about the specific unit:
Lantronix Datamatrix Code
Product Revision
Part Number
Serial Number Hardware Address (MAC Address)
Manufacturing Date Code
xPico® Wi-Fi® Embedded Device Server User Guide
15
Download from Www.Somanuals.com. All Manuals Search And Download.
3: Configuration Using Web Manager
This chapter describes how to configure the xPico Wi-Fi embedded device server using Web
Manager, the Lantronix browser-based configuration tool. The unit’s configuration is stored in
nonvolatile memory and is retained without power. All changes take effect immediately, unless
otherwise noted. It contains the following sections:
Accessing Web Manager
To access Web Manager, perform the following steps:
1. Open a standard web browser. Lantronix supports the latest version of Internet Explorer,
Mozilla Firefox, Safari or Chrome browsers.
2. Enter the IP address or hostname of the xPico Wi-Fi in the address bar. The IP address may
have been assigned manually or automatically by DHCP.
3. Enter your username and password.The factory-default username is “admin” and the
password is “PASSWORD” (all capitalized). The Status web page displays product
information, network settings, line settings, and tunneling settings.
xPico® Wi-Fi® Embedded Device Server User Guide
17
Download from Www.Somanuals.com. All Manuals Search And Download.
3: Configuration Using Web Manager
Status Page
The Status page is the first to appear after you log into Web Manager. The Status page also
appears when you click Status tab in Web Manager.
Figure 3-1 Status Page
xPico® Wi-Fi® Embedded Device Server User Guide
18
Download from Www.Somanuals.com. All Manuals Search And Download.
3: Configuration Using Web Manager
Web Manager Components
The layout of a typical Web Manager page is below.
Figure 3-2 Components of the Web Manager Page
Items to
Links to
configure
subpages
Header
Menu Bar
Footer
Information
and Help Area
Configuration and/or Status Area
Navigating Web Manager
The Web Manager provides an intuitive point-and-click interface. A menu bar on the left side of
each page provides links you can click to navigate between pages. Some pages are read-only,
while others let you change configuration settings.
Note: There may be times when you must reboot the xPico Wi-Fi for the new
configuration settings to take effect. The chapters that follow indicate when a change
requires a reboot. Anytime you reboot the unit, this operation will take some time to
complete. Please wait a minimum of 10-20 seconds after rebooting the unit before
attempting to make any subsequent connections.
xPico® Wi-Fi® Embedded Device Server User Guide
19
Download from Www.Somanuals.com. All Manuals Search And Download.
3: Configuration Using Web Manager
Table 3-3 Web Manager Pages
Web Manager Page Description
See
Page
Status
CPM
Shows product information, network, line status, and tunneling settings.
set the configurable pins and roles to work with a device.
Device
Diagnostics
File System
HTTP
Lets you perform various diagnostic procedures.
Shows file system statistics and lets you perform file system operations.
Shows HyperText Transfer Protocol (HTTP) status and lets you change the
current configuration and authentication settings.
Line
mode settings of a serial line.
Modem Emulation
Monitor
Lets you view and configure Modem Emulation.
Lets you query and capture information during serial port to serial device
connection.
Network
Shows status and lets you configure the network interface.
Quick Connect
Performance
SPI
Lets you change settings effecting performance.
Lets you configure SPI settings.
Tunnel
Lets you change the current configuration settings for an incoming tunnel
connection.
Users
Lets you configure Admin User password.
WLAN Profiles
Lets you view, edit, delete and create a WLAN profile on a device.
xPico® Wi-Fi® Embedded Device Server User Guide
20
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
The Network Settings show the status of the Software enabled Access Point (SoftAP) or WLAN
interface/link and let you configure the settings on the device. Interface settings are related to the
configuration of the IP and related protocols. Link settings are related to the physical link
connection, which carries the IP traffic.
The xPico Wi-Fi embedded device server contains two network interfaces. The Software enabled
Access Point interface is also called interface 1 or ap0, and the WLAN interface is called interface
2 or wlan0.
Note: All network settings require a reboot to take effect. Wait a minimum of 20 seconds
after rebooting the unit before attempting to make any subsequent connections.
Network 1 Interface (ap0) Configuration
Software enabled Access Point (ap0) interface.
Table 4-1 Network Interface Settings
Network (ap0) Interface Description
Settings
State
Click to enable or disable the SoftAP. If enabled, the DHCP server will assign IP
addresses to the SoftAP’s clients. A maximum of four clients can be connected
to the SoftAP interface if the STA interface is disabled. If the STA interface is
enabled a maximum of three clients may be connected.
Note: A DHCP lease lasts for a day. If the IP network is managed manually, a
static IP can be used outside the range of the DHCP address pool.
IP Address
Enter the static IP address to use for the interface. You may enter it in one of
the following ways:
Alone (i.e., 192.168.1.1)
In CIDR format (i.e., 192.168.1.1/24)
With an explicit mask (i.e., 192.168.1.1 255.255.255.0)
To Configure Network 1 Interface Settings
Using Web Manager
To modify Software enabled Access Point (ap0) settings, go to Network on the menu and
select ap0 -> Interface -> Configuration.
Using CLI
To enter the Interface command level: config -> Interface <instance>
Using XML
Include in your file: <configgroup name = "Interface" instance = "ap0">
xPico® Wi-Fi® Embedded Device Server User Guide
21
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
To View Network 1 Interface Status
Using Web Manager
In Network Interface Status, you can view both the current operational settings as well as the
settings that would take effect upon a device reboot.
To view current access point (ap0) settings, go to Network on the menu and select ap0 ->
Interface -> Status.
Using CLI
To enter the Interface command level: status -> Interface <instance>
Using XML
Look for the status header: <statusgroup name = "Interface" instance = "ap0">
Network 1 (ap0) Link Settings
Physical link parameters can be configured for an access point (ap0) Network Interface (see
Table 4-2 Network 1 (ap0) Link Settings
Network 1 (ap0) Link
Settings
Description
SSID
Specify the name of the wireless network (SSID) for the SoftAP.
Specify the channel for the SoftAP.
Channel
Suite
Specify the security suite to be used for the SoftAP.
None = no authentication or encryption method will be used.
WPA = WiFi Protected Access
WPA2 = Robust Secure Network.
Encryption
Passphrase
Select one or more encryption types, listed from strongest to least strong.
CCMP = Uses AES as basis and is the strongest encryption option.
TKIP = Uses WEP as the basis, but adds extra checks and variations for
added protection.
Select the passphrase which may consist of up to 63 characters.
Note: This configuration option becomes available only when suites WPA
or WPA2 are selected. Lantronix recommends using a passphrase of 20
characters or more for maximum security. Spaces and punctuation
characters are permitted. The passphrase input is not the same as ASCII
input (as used on some products.) ASCII is translated directly into
hexadecimal bytes according to the ASCII table, while a possibly larger
passphrase is hashed into a key and provides better security through a
larger range of key values.
xPico® Wi-Fi® Embedded Device Server User Guide
22
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
Network 1 (ap0) Link
Settings (continued)
Description
Mode
Select the desired mode for the link connection from the drop-down menu:
Always Up: when enabled, the SoftAP is always on.
Triggered: when enabled, the SoftAP operates in Triggered mode.
Triggered AP mode is a means to enable the xPico Wi-Fi SoftAP via a
hardware signal. This allows a user to have the SoftAP operating only
when an external signal/button is activated. This might be useful when
power consumption is a concern yet the SoftAP is needed. One
potential use is device provisioning. When triggered, the SoftAP will
remain active for the configured uptime waiting for a client to connect. If
no client connects before the uptime expires, the SoftAP goes back
down. If one or more clients connect, the SoftAP will remain active until
the last client disconnects, at which point it will go down. Refer to
Chapter 7: Configurable Pin Manager for details on how to set up the
xPico Wi-Fi unit for this feature
Uptime
Enter the length of uptime for the link connection.
To Configure Network 1 Link Settings
Using Web Manager
To modify network (ap0) Link information, click Network on the menu and select apo > Link >
Configuration.
Using CLI
To enter the Access Point command level: config -> Access Point
Using XML
Include in your file: <configgroup name = "Access Point" instance = "ap0">
To View Network 1 Link Status
Using Web Manager
In Network Link Status, you can view the current operational settings.
To view current network (ap0) settings, go to Network on the menu and select ap0 -> Link ->
Status.
Using CLI
To enter the Access Point command level: status -> Access Point
Using XML
Look for the status header: <statusgroup name = "Access Point" instance =
"ap0">
xPico® Wi-Fi® Embedded Device Server User Guide
23
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
Network 2 (wlan0) Interface Configuration
This page is used to configure the network 2 interface on the device. To see the effect of these
items after a reboot, view the Status page.
Table 4-3 Network Interface Settings
Network Interface
Settings
Description
State
Click to enable or disable the WLAN interface.
DHCP Client
Click to enable or disable the DHCP client. If enabled, any configured IP
address, network mask, gateway or hostname will be ignored. DHCP will auto-
discover and eclipse those configured items. When DHCP fails to discover an
IP address, a new address will automaticaly be generated using AutoIP. This
address will be within the 169.254.x.xspace. At boot up, after the physical
link is up, the xPico Wi-Fi will attempt to obtain IP settings from a DHCP server
and will periodically renew these settings with the server.
Note: Click renew on Interface Status page to force DHCP lease renewal.
IP Address
Enter the static IP address to use for the interface. You may enter it in one of
the following ways:
Alone (i.e., 192.168.1.1)
In CIDR format (i.e., 192.168.1.1/24)
With an explicit mask (i.e., 192.168.1.1 255.255.255.0)
Note: This setting will be used if Static IP is active (DHCP Client is Off).
Enter the IP address of the router for this network.
Default Gateway
Hostname
Note: This setting will be used if Static IP is active (DHCP Client is Off).
Enter the hostname for the interface. It must begin with a letter, continue with a
letter, number or hyphen, and must end with a letter or number. The device will
not register the hostname with a DNS server until the next reboot.
Primary DNS
Enter the IP address of the primary Domain Name Server.
Note: This setting will be used when Static IP is active.
Secondary DNS
Enter the IP address of the secondary Domain Name Server.
Note: This setting will be used when Static IP is active.
To Configure Network 2 Interface Settings
Using Web Manager
To modify network 2 WLAN interface information, click Network on the menu and select
wlan0 > Interface > Configuration.
Using CLI
To enter the Interface command level: config -> Interface <instance>
xPico® Wi-Fi® Embedded Device Server User Guide
24
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
Using XML
Include in your file: <configgroup name = "Interface" instance = "wlan0">
To View Network 2 Interface Status
Using Web Manager
In Network Interface Status, you can view both the current operational settings as well as the
settings that would take affect upon a device reboot.
To view current access piont (ap0) settings, go to Network on the menu and select wlan0 ->
Interface -> Status.
Using CLI
To enter the WLAN command level: status -> WLAN
Using XML
Look for the status header: <statusgroup name = "Interface" instance =
"wlan0">
Network 2 (wlan0) Link Status
This page shows status of a Link on the device.
To View Network 2 Link Status
Using Web Manager
To view network 2 link interface information, click Network on the menu and select wlan0 >
Link > Status.
Using CLI
To enter the WLAN command level: status -> WLAN
Using XML
Include in your file: <configgroup name = "Interface" instance = "wlan0">
WLAN Profiles
A WLAN profile defines all of the settings necessary to establish a wireless connection with an
access point (in infrastructure mode). A maximum of four profiles can exist on the xPico Wi-Fi
embedded device server at a time and only one profile may be active at any given time.
The xPico Wi-Fi device supports dynamic profiles. Dynamic Profiles are the ones created via
QuickConnect.
xPico® Wi-Fi® Embedded Device Server User Guide
25
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
WLAN Profile WEP Settings
WEP is a simple and efficient security mode encrypting the data via the RC4 algorithm. However,
WEP has become more vulnerable due to advances in hacking technology. State of the art
equipment can find WEP keys in five minutes. For stronger security, please use WPA, or better,
WPA2 with AES (CCMP). WEP is only supported on the STA interface.
WLAN Profile WPA and WPA2 Settings
WPA is a security standard specified by the WiFi Alliance and is a close derivative of an early draft
of the IEEE802.11i specification. WEP was becoming vulnerable when finalizing the IEEE802.11i
standard was still far away. WPA2 is WiFi’s subset of the broad IEEE802.11i standard to enforce
better interoperability. The xPico Wi-Fi embedded device server is compliant with both WPA2 and
IEEE802.11i.
To Configure WLAN Profiles
You can view, edit, create or delete a WLAN profile.
Using WebManager
Click WLAN Profiles on the menu.
Using CLI
To enter the WLAN Profile command level: config -> WLAN Profile <instance>
Using XML
Include in your file: <configgroup name = "WLAN Profile" instance = "name">
Table 4-4 Creating, Deleting or Enabling WLAN Profiles
WLAN Profile Basic Settings
Description
Create new profile
Type the name of the new profile to be created into the Create new
WLAN Profile field. Then, click the Submit button which appears to
create the profile. Once created, the profile name may be clicked so you
may edit profile settings.
Delete (checkbox)
Click the Delete checkbox beside the profile(s) to be deleted. Two
buttons will appear:
Click the Apply button to delete the profile for testing purposes. If the
device reboots, this change will not be applied.
Click the Submit button to permanently delete profile(s).
View or Edit
(link to specific profile)
Click on a specific WLAN Profile name to edit the WLAN profile basic
settings.
To Configure WLAN Profile Settings
Using Web Manager
To view or edit an existing WLAN profile, click WLAN Profiles on the menu and select an
xPico® Wi-Fi® Embedded Device Server User Guide
26
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
Using CLI
To enter the WLAN Profile command level: config -> WLAN Profile <instance>
Using XML
Include in your file: <configgroup name = "WLAN Profile" instance = "name">
Table 4-5 WLAN Profile Basic Settings
WLAN Profile Basic
Description
Settings
Network Name (SSID)
State
Specify the name of the wireless network (SSID.)
Select to enable or disable this profile.
Table 4-6 WLAN Profile Security Settings
WLAN Profile
Description
Security Settings
Suite
Specify the security suite to be used for this profile.
None = no authentication or encryption method will be used.
WEP = Wired Equivalent Privacy
WPA = WiFi Protected Access
WPA2 = Robust Secure Network.
Key Size
Select the appropriate key size in bits. Select 40 for WEP40 and WEP64; select
104 for WEP104 and WEP128.
Note: This option is available if WEP suite is selected above.
TX Key Index
Select one of four index listing keys for transmitting data. Reception is allowed
with all four keys.
Note: For operability with some products that generate four identical keys from a
passphrase, this index must be one. This option is available if WEP suite is
selected above.
Key 1-4
Enter one or more encryption keys in hexadecimal format. Enter 10 hexadecimal
digits (0-9, a-f) for WEP40 and 26 for WEP104. The configured keys are not
shown for security reasons.
Note: This option is available if WEP suite is selected above.
WPAx Key Type
WPAx Key
Select the format of the security key.
Note: This configuration option becomes available only when suites, WPA or
WPA2 are selected.
Enter the WPAx key.
Note: This configuration option becomes available only when suites, WPA or
WPA2 are selected and the Hex key type is selected.
xPico® Wi-Fi® Embedded Device Server User Guide
27
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
WLAN Profile
Description
Security Settings
WPAX Passphrase
Select the password consists of up to 63 characters.
Note: Lantronix recommends using a passphrase of 20 characters or more for
maximum security. Spaces and punctuation characters are permitted. The
passphrase input is not the same as ASCII input (as used on some products.)
ASCII is translated directly into hexadecimal bytes according to the ASCII table,
while a possibly larger passphrase is hashed into a key and provides better
security through a larger range of key values. This configuration option becomes
available only when suites, WEP, WPA or WPA2 are selected.
WPAx Encryption
Select one or more encryption types, listed from strongest to least strong. At least
one selection will have to match the Access Points intended to connect with.
CCMP = Uses AES as basis and is the strongest encryption option.
TKIP = Uses WEP as the basis, but adds extra checks and variations for added
protection.
Note: In case the encryption settings on the Access Point(s) can still be chosen,
the capabilities of the Access Point(s) and the other clients that need to use the
network need to be taken into account.This configuration option becomes
available only when suites WPA or WPA2 are selected.
Table 4-7 WLAN Profile Advanced Settings
WLAN Profile Advanced Settings Description
TX Power Maximum
Power Management
Specify the maximum transmission output power in dBm.
Select to Enable or Disable power management, which reduces the
overall power consumption of the xPico Wi-Fi unit, but can increase
latency.
Enabled = allows the xPico Wi-Fi to turn off the receiver when it is
idling.
Disabled = keeps the receiver on at all times.
Power Management Interval
Select number of beacons (100 msec interval) between 1 and 5. The
above-mentioned latency can be up to this number “X” 100 msec.
WLAN Quick Connect
WLAN QuickConnect allows users to view and add up to four WLAN profiles from a list of up to 20
wireless devices sorted by RSSI. Details of the selected network are pre-populated, so little or no
configuration is required by the user.
To Configure WLAN Quick Connect
Using Web Manager
To view or edit an existing WLAN Quick Connect settings, click QuickConnect on the menu.
Using CLI
Not applicable.
xPico® Wi-Fi® Embedded Device Server User Guide
28
Download from Www.Somanuals.com. All Manuals Search And Download.
4: Network Settings
Using XML
Not applicable.
Table 4-8 WLAN Quick Connect
WLAN Quick Connect
Settings
Description
Network Name (search field) Enter a network name and click Scan to search for a network.
Scan “<network SSID>”
Perform a scan for devices within range of the xPico Wi-Fi. Including the
optional network SSID limits the scan to devices configured with the
specified network SSID. Omitting the network SSID performs a scan for all
devices in range.
Network Name (link)
Lists the SSID of a network. Click a specific Network Name to display the
Quick Connect profile. If you provide the Password for a specific Quick
to four WLAN profiles may be added, and only one may be connected at
any given time.
BSSID
Lists the basic service set identifier. This is a unique 48-bits address that
identifies the access point that creates the wireless network.
CH
Provides the channel number of a network.
RSSI
Displays an instantaneous value indicating the signal strength of the
network. The best to worst signal strength is indicated by green, yellow and
red respectively.
Note: RSSI reported in scan results is a single sampling.
Security Suite
Lists the security suite of a network (e.g., WEP, WPA, WPA2).
xPico® Wi-Fi® Embedded Device Server User Guide
29
Download from Www.Somanuals.com. All Manuals Search And Download.
5: Interface Settings
Line Settings
The Line Settings allow configuration of the serial lines (ports). Some settings may be specific to
only certain lines. Such settings are noted below.
Note: The settings described below apply to both Line 1 and Line 2 unless otherwise
noted.
Table 5-1 Line Configuration Settings
Line Settings
Name
Description
Enter a name or short description for the line, if desired. By default, there is
no name specified. A name that contains white space must be quoted.
State
Select to Enable or Disable the operational state of the Line. The default is
an enabled state.
Protocol
Set the operational protocol for the Line. The default is Tunnel for Line 1 and
Command Line for Line 2. Choices are:
Command Line
Modem Emulation
Monitor
None
Trouble Log
Tunnel = Serial-Network tunneling protocol (Line 1 only)
Baud Rate
Set the Baud Rate (speed) of the Line. The default is 9600.
A custom speed or any set speed between 1200 and 921600 may be
selected: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400,
460800, 921600. If a custom speed is selected, indicate the bits per second in
the field which appears.
Parity
Set the Parity of the Line. The default is None.
Note: Serial lines do not support the following Data Bit/Parity combinations:
a) 7 Data Bits with No Parity and 1 Stop Bit.
b) 8 Data Bits with 2 Stop Bits.
Data Bits
Set the number of data bits for the Line. The default is 8.
Note: Serial lines do not support the following Data Bit/Parity combinations:
a) 7 Data Bits with No Parity and 1 Stop Bit.
b) 8 Data Bits with 2 Stop Bits.
Stop Bits
Set the number of stop bits for the Line. The default is 1.
Flow Control
Set the flow control for the Line. The default is None. Hardware flow control is
only supported on Line 1.
Xon Char
Specify the Xon Character which is used when Flow Control is set to
Software. Set the prefix in one of the three ways:
Prefix decimal with prefix hexadecimal and 0x
Prefix hexadecimal with 0x
Prefix as a single control character with <control>
xPico® Wi-Fi® Embedded Device Server User Guide
30
Download from Www.Somanuals.com. All Manuals Search And Download.
5: Interface Settings
Line Settings
Xoff Char
Description
Specify the Xoff Character which is used when Flow Control is set to
Software. Set the prefix in one of the three ways:
Prefix decimal with prefix hexadecimal and 0x
Prefix hexadecimal with 0x
Prefix as a single control character with <control>
Gap Timer
Threshold
Set the Gap Timer delay to Set the number of milliseconds to pass from the
last character received before the driver forwards the received serial bytes.
By default, the delay is four character periods at the current baud rate
(minimum 1 msec). Gap Timer range is 1 to 5000 milliseconds.
Set the number of threshold bytes which need to be received in order for the
driver to forward received characters. Default value is 56 bytes.
To Configure Line Settings
Note: The following section describes the steps to view and configure Line 1 settings;
these steps apply to other line instances of the device.
Using Web Manager
To configure a specific line, click Line in the menu and select Line 1 -> Configuration
Using CLI
To enter the Line command level: config -> Line <instance>
Using XML
Include in your file: <configgroup name = "Line" instance = "1">
To View Line Status
Using Web Manager
To view statistics for a specific line, click Line in the menu and select Line 1 -> Status.
Using CLI
To enter the Line command level: status -> Line <instance>
Using XML
Look for the status header: <statusgroup name = "Line" instance = "1">
xPico® Wi-Fi® Embedded Device Server User Guide
31
Download from Www.Somanuals.com. All Manuals Search And Download.
5: Interface Settings
Serial Perpheral Interface (SPI) Settings
SPI settings pertaining to the bus master device can be modified in the xPico Wi-Fi unit. SPI
settings, like line settings, allow for the selection of a protocol to be used with SPI. Changes take
effect immediately.
Table 5-2 SPI Configuration Settings
Line Settings
Name
Description
Enter a name or short description for the line, if desired. By default, there is
no name specified. This name is for display only.
State
Select to Enable or Disable the SPI.
Protocol
Select the operational protocol for connection to the SPI:
None: selects no application to connect to the SPI.
Monitor: selects Monitor application to connect to the SPI.
Target Speed
Set the target clock speed of the SPI in Hz (range is 234.375 KHz - 30 MHz).
The target speed may be lowered to the closest operating speed capability of
the device. If so, a warning will be noted. 0 or clearing the selection selects
the minimum speed.
Idle Clock Level
Clock Edge
Select the level of the clock or clock polarity (CPOL) when the clock is idle:
Low: the idle clock is at a low level. This is equivalent to CPOL=0.
High: the idle clock is at a high level. This is equivalent to CPOL=1.
Select the clock edge or clock phase (CPHA) for latching data:
First: each bit is latched on the first edge of the clock. This is equivalent to
CPHA=0.
Second: each bit is latched on the second edge of the clock. This is
equivalent to CPHA=1.
Bits Per Word
First Transfer
Select the number of bits per word to transfer. Choices in drop-down menu
are 8 or 16.
Select the first transfer bit of each word. Choicse in drop-down menu include:
Most Significant Bit
Least Signficant Bit
To Configure SPI Settings
Using Web Manager
To configure the SPI bus master device settings, click SPI in the menu and select
Configuration.
Using CLI
To enter the SPI command level: config -> SPI
Using XML
Include in your file: <statusgroup name = "SPI" instance = "1">
xPico® Wi-Fi® Embedded Device Server User Guide
32
Download from Www.Somanuals.com. All Manuals Search And Download.
5: Interface Settings
To View SPI Status
Using Web Manager
To view the current status and statistics for the SPI bus master device, click SPI in the menu
and select Status.
Using CLI
To enter the SPI command level: status -> SPI
Using XML
Include in your file: <statusgroup name = "SPI" instance = "1">
xPico® Wi-Fi® Embedded Device Server User Guide
33
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
The xPico Wi-Fi embedded device server has two lines available for tunneling.
Tunnel Settings
Tunneling allows serial devices to communicate over a network, without “being aware” of the
devices which establish the network connection between them. Tunneling parameters are
configured using the Tunnel menu and submenus. The Tunnel settings allow you to configure
how the Serial-Network tunneling operates.
Note: The following section describes the steps to view and configure Line 1 settings;
these steps apply to other line instances of the device.
Line Settings
These serial settings for the tunnel apply to the Serial Line interface. The Line Settings and
Protocol are displayed for informational purposes and must be configured from the Line settings.
Table 6-1 Tunnel Line Settings
Tunnel Serial
Settings
Description
Line Settings
Protocol
DTR
Line Settings to modify these settings.
Settings to modify these settings.
Select the DTR conditions in which Data Terminal Ready control signal on the
Serial Line is asserted.
Asserted while connected (Causes DTR to be asserted whenever either a
connect or an accept mode tunnel connection is active).
Continuously asserted
Unasserted
To View Tunnel Serial Settings
Using Web Manager
To view the Serial Settings for a specific tunnel, click Tunnel in the menu and select Tunnel 1
-> Line.
Using CLI
To enter the Tunnel command level: config -> Tunnel <instance>
Using XML
Include in your file: <configgroup name = "Tunnel Line" instance = "1">
xPico® Wi-Fi® Embedded Device Server User Guide
34
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Packing Mode
With Packing, data from the serial Line is not sent over the network immediately. Instead, data is
queued and sent in segments, when either the timeout or byte threshold is reached. Packing
applies to both Accept and Connect Modes.
Table 6-2 Tunnel Packing Mode Settings
Tunnel Packing Mode
Settings
Description
Mode
Configure the Tunnel Packing Mode. Choices are:
Disable = Data not packed.
Timeout = data sent after timeout occurs.
Send Character = data sent when the Send Character is read on the Serial
Line.
Timeout
Set the timeout value, in milliseconds, after the first character is received on
the serial line, before data is sent on the network. Valid range is 1 to 30000
milliseconds. Default is 1000.
Note: This configuration option becomes available when Timeout is the
selected Mode.
Threshold
Set the threshold (byte count). If the received serial data reaches this
threshold, then the data will be sent on the network. Valid range is 100 to
1450 bytes. Default is 512.
Note: This configuration option becomes available when Timeout is the
selected Mode.
Send Character
Enter Control Characters in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
If used, the Send Character is a single printable character or a control
character that, when read on the Serial Line, forces the queued data to be
sent on the network immediately.
Note: This configuration option becomes available when Send Character is
the selected Mode.
Trailing Character
Enter Control Characters in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal).
If used, the Trailing Character is a single printable character or a control
character that is injected into the outgoing data stream right after the Send
Character. Disable the Trailing Character by blanking the field (setting it to
<None>).
Note: This configuration option becomes available when Send Character is
the selected Mode.
xPico® Wi-Fi® Embedded Device Server User Guide
35
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
To Configure Tunnel Packing Mode Settings
Using Web Manager
To configure the Packing mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Packing.
Using CLI
To enter the Tunnel command level: config -> Tunnel <instance>
Using XML
Include in your file: <configgroup name = "Tunnel Packing" instance = "1">
Accept Mode
In Accept mode, the xPico Wi-Fi listens (waits) for incoming connections from the network. A
remote node on the network initiates the connection.
The configurable local port is the port the remote device connects to for this connection. There is
no remote port or address. The default local port is 10001.
Serial data can still be received while waiting for a network connection, keeping in mind serial data
buffer limitations.
Table 6-3 Tunnel Accept Mode Settings
Tunnel Accept Mode
Settings
Description
Mode
Set the method used to start a tunnel in Accept mode. Choices are:
Disable = do not accept an incoming connection.
Always = accept an incoming connection (default).
Any Character = start waiting for an incoming connection when any
character is read on the serial line.
Start Character = start waiting for an incoming connection when the
start character for the selected tunnel is read on the serial line.
Local Port
Set the port number for use as the network local port. The default local port
is 10001.
Protocol
Select the TCP type for use with Accept Mode.
Start Character
Enter the start character which will enable the tunnel to listen for a network
connection. The start character may be designated as a single printable
character or as a control character. Control characters may be input in any
of the following forms:
<control>J or 0xA (hexadecimal)or \10 (decimal)
Note: This configuration option becomes available when Start Character
is the selected Mode.
xPico® Wi-Fi® Embedded Device Server User Guide
36
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Tunnel Accept Mode
Settings (continued)
Description
Flush Start Character
Enable or disable the flush start character:
Enabled = prevents forwarding of a start character from the Line into
the network.
Disabled = the flush start character allows forwarding of a start
character from the line into the network.
Note: This configuration option becomes available when Start Character
is the selected Mode.
Flush Line
Block Line
Set whether the serial line data buffer is flushed upon a new network
connection. Choices are:
Enabled = serial data buffer is flushed on network connection
Disabled = serial data buffer is not flushed on network connection
(default)
Set whether Block Line is enabled for debugging purposes. Choices are:
Enabled = if Enabled, incoming characters from the serial line will not
be forwarded to the network. Instead, they will be buffered and will
eventually flow off the serial line if hardware or software flow control is
configured.
Disabled = this is the default setting; incoming characters from the
Serial Line are sent into the network. Any buffered characters are sent
first.
Block Network
Set whether Block Network is enabled for debugging purposes. Choices
are:
Enabled = if Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will
eventually flow off the network side.
Disabled = this is the default setting; incoming characters from the
network are sent on the Serial Line. Any buffered characters are sent
first.
Password
Enter a password. This password can be up to 31 characters in length and
must contain only alphanumeric characters and punctuation. When set,
clients must send the correct password string to the unit within 30 seconds
from opening network connection in order to enable data transmission.
The password sent to the unit must be terminated with one of the following:
0A (Line Feed)
00 (Null)
0D 0A (Carriage Return/Line Feed)
0D 00 (Carriage Return/Null)
If, Prompt for Password is set to Enabled and a password is provided,
the user will be prompted for the password upon connection.
To Configure Tunnel Accept Mode Settings
Using Web Manager
To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Accept.
Using CLI
To enter the Tunnel command level: config -> Tunnel <instance>
xPico® Wi-Fi® Embedded Device Server User Guide
37
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Using XML
Include in your file: <configgroup name = "Tunnel Accept" instance = "1">
Connect Mode
Specifies the conditions for connecting any Accept Mode connection that may be established
locally.
Table 6-4 Tunnel Connect Mode Settings
Tunnel Connect
Mode Settings
Description
Mode
Select the method to start the Connect Tunnel:
Disabled: never started.
Always: always started
Any Character: started when any character is detected on the Serial Line
Start Character: started when the Start Character is detected on the Serial Line.
Local Port
View and if desired, override the default Local Value values.
Local port default values: Tunnel 1 is 10001 and Tunnel 2 is 10002.
Blank the display field to restore to default random setting.
Host <Number>
(Edit button)
Lists exhisting hosts, if any for viewing and editing.
Click the Edit button beside a particular host to view the Address, Port and
Protocol fields for this host.
Make any changes, as desired in the Address, Port and Protocol fields and click
Submit to save.
Up to 2 hosts can be established. Additional hosts become available for editing/
submitting as a host is edited.
Connections
Select the type of connection.
Sequential: connections for tunneling will begin from host 1 and proceed in
sequence until a connection is accepted.
Simultaneous: all hosts accepting connetions will be connected.
Reconnect Time
Flush Line
Enter the reconnection time, which specifies how long the xPico Wi-Fi device server
will wait in seconds before trying to reconnect to the remote host after a failed
attempt or closed connetion. Blank the display field to restore the default.
Select to enable or disable the flush line at the time a connection is established with
the network.
Enabled: buffered characters from the serial line will be discarded when a
connection is established.
Disabled: any characters received on the serial line will be buffered and sent
after a connection is established.
Block Line
Select to enable or disable the block line, which is used for debugging purposes.
Enabled: incoming characters from the serial line will not be forwarded to the
network but will be buffered and will eventually flow off the serial line, if hardware
or software flow control is configured.
Disabled: incoming characters from the serial line are sent to the network. Any
buffered characters are sent first. This is the “normal” setting.
xPico® Wi-Fi® Embedded Device Server User Guide
38
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Tunnel Connect
Mode Settings
Description
Block Network
Select to enable or disable the block network, which is used for debugging
purposes.
Enabled: incoming characters from the network will not be forwarded to the
serial line but will be buffered and eventually flow off the network side.
Disabled: incoming characters from the network are sent on into the serial line.
Any buffered characters are sent first. This is the “normal” setting.
To Configure Tunnel Connect Mode Settings
Using Web Manager
To configure the Disconnect Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Connect.
Using CLI
To enter the Tunnel command level: config -> Tunnel <instance>
Using XML
Include in your file: <configgroup name = "Tunnel Connect" instance = "1">
Disconnect Mode
Specifies the optional conditions for disconnecting any Accept Mode connection that may be
established. If any of these conditions are selected but do not occur and the network disconnects
from the device, a Connect Mode connection will attempt to reconnect. However, if none of these
conditions are selected, a closure from the network is taken as a disconnect.
Table 6-5 Tunnel Disconnect Mode Settings
Tunnel Disconnect
Mode Settings
Description
Stop Character
Enter the Stop Character which when received on the Serial Line, disconnects the
tunnel. The Stop Character may be designated as a single printable character or
as a control character. Control characters may be input in any of the following
forms: <control>J or 0xA (hexadercimal) or \10 (decimal). Disable the Stop
Character by blanking the field to set it to <None>.
Modem Control
Timeout
Select to enable or disable the disconnect when modem control pin is not asserted
on the serial line.
Enter the number of milliseconds a tunnel may be idle before disconnection. The
value of zero disables the idle timeout.
Flush Line
Set whether to flush the Serial Line when the Tunnel is disconnected. Choices are:
Enabled
Disabled (default)
xPico® Wi-Fi® Embedded Device Server User Guide
39
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
To Configure Tunnel Disconnect Mode Settings
Using Web Manager
To configure the Disconnect Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Disconnect.
Using CLI
To enter the Tunnel command level: config -> Tunnel <instance>
Using XML
Include in your file: <configgroup name = "Tunnel Disconnect" instance = "1">
Statistics
Tunnel statistics contains data counters, error counters, connection time and connection
information. Statistics are available at each individual connection and aggregated across all
connections.
To View Tunnel Statistics
Using Web Manager
To view statistics for a specific tunnel, click Tunnel in the menu and select the Tunnel 1 ->
Status.
Using CLI
To enter the Tunnel command level: status -> Tunnel <instance>
Using XML
Look for the status header: <statusgroup name = "line" instance = "1">
Modem Emulation Settings
Note: The following section describes the steps to view and configure Modem Emulation
1 settings; these steps also apply to Modem Emulation 2 settings.
Table 6-6 Modem Emulation Settings
Modem Emulation
Settings
Description
Listen Port
Specify a listen port to accept connections.
Echo Pluses
Select to enable or disable echo pluses to be echoed back during “pause +++
pause” escape sequence on the serial line.
Echo Commands
Select to enable or disable echo commands. If enabled, characters read on the
serial line are echoed while the modem is in Modem Command Mode.
xPico® Wi-Fi® Embedded Device Server User Guide
40
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Modem Emulation
Settings
Description
Verbose Response
Select to enable or disable verbose response. If enabled, modem response codes
are sent out on the serial line.
Response Type
Select either Text or Numeric representation for the modem response codes sent
out on the serial line.
Error Unknown
Commands
Select to enable or disable error unknown commands. If enabled, ERROR is
returned to the serial line for unrecognized AT commands.
Incoming
Select Automatic, Manual or Disabled for the handling of incoming connections.
Connection
Connect String
Specify a customized string to be sent with the CONNECT modem response code
to the serial line, if any.
Display Remote IP
Select to enable or disable display remote IP. If enabled, the incoming ring sent on
the serial line is followed by the IP address of the caller.
Using Web Manager
To configure the modem emulation for a specific tunnel, click Modem Emulation in the menu
and select Modem Emulation 1 -> Configuration.
To view the modem emulation status for a specific tunnel, click Modem Emulation in the
menu and select Modem Emulation 1 -> Status.
Using the CLI
To enter the Modem Emulation command level: config -> Modem Emulation <1>
Using XML
Include in your file: <configgroup name=”Modem Emulation” instance=”1”>
Table 6-7 Modem Emulation Commands and Descriptions
Command
Description
AT?
Help. Displays this table.
ATA
Answer incoming call request (if ATS0=2 or greater).
Connects to the configured Connect Mode address and port.
<address>:<port> Connects to the specified address and port.
Enters the Command Line Interface (CLI); exit returns to AT commands.
Same as ATD.
ATD
ATD
ATD 0
ATDP
ATDT
ATEn
ATH
Same as ATD.
Switches echo in command mode (n=0: off, n=1: on).
Disconnects the network session.
ATI
Displays modem information.
ATO
Switches to data mode if connection still exists. Reverse of '+++'.
Quiet mode (n=0: enable results code, n=1: disable results code.)
Accept connection. (n=0: no, n=1: auto, n=2+: via ATA command).
ATQn
ATS0=n
xPico® Wi-Fi® Embedded Device Server User Guide
41
Download from Www.Somanuals.com. All Manuals Search And Download.
6: Tunnel Settings
Command
ATUn
ATVn
ATXn
ATZ
Description
Accept unknown commands. (n=0: off, n=1: on).
Verbose mode (n=0: numeric result codes, n=1: text result codes.)
Command does nothing and returns OK status.
Restore active settings from defaults.
Reset saved settings in NVR to factory defaults.
Display current and saved settings.
Save active settings to NVR.
AT&F
AT&V
AT&W
AT&Z
A/
Restore active settings from NVR.
Repeat last command.
+++
Switches to command mode if entered from serial port during connection.
xPico® Wi-Fi® Embedded Device Server User Guide
42
Download from Www.Somanuals.com. All Manuals Search And Download.
7: Configurable Pin Manager
The Configurable Pin Manager (CPM) is responsible for the assignment and control of the
configurable pins (CPs) available on the xPico Wi-Fi embedded device server. There are eight
configurable pins on the xPico Wi-Fi unit.
You must configure the CPs by making them part of a role. A CP role may consist of one or more
CPs. This increases flexibility when incorporating the xPico Wi-Fi device into another system.
Note: The blue text in the XML command strings of this chapter are to be replaced with
a user-specified name.
Configurable Pin Status
Each CP is associated with an external hardware pin. The Current Configuration table shows the
sample settings for each CP.
Table 7-1 Current Configurable Pins
CP
Ref
Usage
Input
Input
Input
Input
Input
Input
Input
Input
Assert
High
High
High
High
High
High
High
High
Mode
Value
Roles
Active in Role
<available>
<available>
<available>
<available>
<available>
<available>
<available>
<available>
CP1
CP2
CP3
CP4
CP5
CP6
CP7
CP8
Pin 35
Pin 26
Pin 28
Pin 30
Pin 32
Pin 34
Pin 27
Pin 3
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
Push-Pull
0
1
1
0
1
0
0
0
0
1
0
0
0
0
0
-0
Table 7-2 CP Status
CPM – CPs Status
Ref
Description
Indicates the pin number on the device which corresponds to this
configurable pin.
Usage
Indicates whether this pin is set as Input, Output or Reserved (for a
different use).
Assert
Mode
Indicates the polarity of the configurable pin as High or Low.
Indicates whether this pin is setup for push-pull or if it enables an
internal weak pullup.
Value
Roles
Indicates the logical value of the configurable pin.
Indicates the number of configurable pin roles which refer to this pin.
xPico® Wi-Fi® Embedded Device Server User Guide
43
Download from Www.Somanuals.com. All Manuals Search And Download.
7: Configurable Pin Manager
CPM – CPs Status (continued)
Active in Role
Description
Indicates the current active role that uses this pin. If there is currently
no role, <available> will display. Click a specific action as desired for
the configurable pin:
Usage Input
Usage Output
Usage Unused
Assert High
Assert Low
Mode Push-Pull
Mode Weak Pullup
Value 0
Value 1
Note: To modify a CP, all roles in which it is a member must be disabled.
Note: The changes to a CP configuration are not saved in FLASH. Instead, these CP
settings are used when the CP is added to a CP Role. When the CP Role is saved, its CP
settings are saved with it. Thus, a particular CP may be defined as "Input" in one role but
as "Output" in another. Only one role containing any particular CP may be enabled at
once.
Roles
The CP Role settings allow for the management of CP roles. Roles are configurable, may be
enabled or disabled and can be assigned or unassigned to a configurable pin. A role, based on its
state, can trigger outside events. Only an enabled role can be a trigger.
xPico Wi-Fi roles available for assignment to a configurable pin include the following:
Role AP Trigger
Role Line 1 DSR
Role Line 1 DTR
Role Line 2 DSR
Role Line 2 DTR
Role Line 2 Flow.CTS
Role Line 2 Flow.RTS
Role SPI.CS
Role SPI.INT
Role SPI.MISO
Role SPI.MOSI
Role SPI.SCK
xPico® Wi-Fi® Embedded Device Server User Guide
44
Download from Www.Somanuals.com. All Manuals Search And Download.
7: Configurable Pin Manager
Table 7-3 Role Configuration
Description
CPM – Role Current
Configuration
CP
View or modify the number of the configurable pin assigned to this role. Enter 0
or blank the field to revert to <No CP Selected>.
State
View or modify whether the role is enabled or disabled for use.
View or modify the polarity of the cp role as High or Low.
Shows the number of CPs assigned to the role.
Assert
Mode
To Configure CPM Settings
Using Web Manager
To view or configure a configurable pin, click CPM in the menu, select CPs then the Detail link
to the right of a specific CP to configure.
To configure a CPM role, click CPM in the menu, select Roles > Configuration and then the
Edit link to the right of a specific role to configure.
To view a CPM role status, click CPM in the menu, select Roles > Status and then the Detail
link to the right of a specific role to view details.
Using the CLI
To enter the CPM command level: config -> CPM
Using XML
Include in your file: <configgroup name=”cpm”>
Include in your file: <statusgroup name= “CPM Roles”>
Include in your file: <statusgroup name= “CPM CPs”>
xPico® Wi-Fi® Embedded Device Server User Guide
45
Download from Www.Somanuals.com. All Manuals Search And Download.
8: Services Settings
HTTP Settings
Hypertext Transfer Protocol (HTTP) is the transport protocol for communicating hypertext
documents on the Internet. HTTP defines how messages are formatted and transmitted. It also
defines the actions web servers and browsers should take in response to different commands.
HTTP Authentication enables the requirement of usernames and passwords for device access.
Table 8-1 HTTP Settings
HTTP Settings
State
Description
Select to enable or disable the HTTP server:
Enabled (default)
Disabled
Port
Enter the port for the HTTP server to use. The default (80) will be restored
when the field is cleared.
Inactivity Timeout
Enter the amount of time the HTTP server will hold power on after completing
a request. This setting only applies if HTTP Server is enabled in
Performance.
URI
Displays the root of the Uniform Resource Identifier (URI) to apply access
control settings.
Note: The URI must begin with ‘/’ to refer to the entire file system.
Auth Type
Users
Select the authentication type:
None: no authentication is necessary.
Basic: encodes passwords using Base64.
Displays the username allowed to access the configured URI.
To Configure HTTP Settings and Access Control
Using Web Manager
To configure HTTP settings, click HTTP in the menu and select Configuration.
Using CLI
To enter the HTTP Server command level: config -> HTTP Server
Using XML
Include in your file: <configgroup name = "HTTP Server">
Include in your file: <configgroup name = "HTTP Server Access Control"
instance=”1”>
xPico® Wi-Fi® Embedded Device Server User Guide
46
Download from Www.Somanuals.com. All Manuals Search And Download.
8: Services Settings
To View HTTP Status
Using Web Manager
To view HTTP status, click HTTP in the menu and select Status.
Using CLI
To enter the HTTP Server command level: status -> HTTP Server>
Using XML
Look for the status header: <statusgroup name = "HTTP Server">
xPico® Wi-Fi® Embedded Device Server User Guide
47
Download from Www.Somanuals.com. All Manuals Search And Download.
9: Maintenance and Diagnostics Settings
File System Settings
The xPico Wi-Fi embedded device server uses a flash file system to store files. The file system
can be formatted and compacted: formatting erases all files while preserving configuration, and
compacting reclaims dirty space while preserving all files.
The file system also provides statistics and the ability to create, delete, and manipulate files and
directories.
File System Statistics
Table 9-1 File System Statistics Settings
File System Commands
Compact
Description
Compact the File System to reclaim dirty flash storage while preserving any
existing files and directories.
Format
Format the File System to erase all existing files and directories, while
preserving configuration.
To View File System Statistics, Compact or Format the File System
Using Web Manager
To view file system statistiscs, compact or format the file system, click FIle System in the
menu.
Using CLI
To enter the File System command level: status -> File System
Using XML
Look for the status header: <statusgroup name = "File System”>
File Display
It is possible to view the list of existing files, and to view their contents.
To Display Files
Using Web Manager
To view existing files and file contents, click File System in the menu and select Browse.
Using the CLI
To enter the File System command level: enable -> file system
xPico® Wi-Fi® Embedded Device Server User Guide
48
Download from Www.Somanuals.com. All Manuals Search And Download.
9: Maintenance and Diagnostics Settings
Using XML
Not applicable.
File Manipulation
The xPico Wi-Fi embedded device server allows for files to be deleted, moved, renamed, and
uploaded via HTTP. Directories can be created, deleted, moved, and renamed.
To Transfer or Modify File System Files
Using Web Manager
To create a new file or directory, upload an existing file, copy or move a file, click File System
in the menu and select Browse.
Using the CLI
To enter the File System command level: enable -> file system
Using XML
Not applicable.
Device Settings
The xPico Wi-Fi Device settings allow for rebooting the device, restoring factory defaults, and
uploading new firmware.
Anytime you reboot the unit, this operation will take some time to complete. Please wait a
minimum of 10-20 seconds after rebooting the unit before attempting to make any subsequent
connections.
Device Management
Table 9-2 Device Management Settings
System Settings
Save
Description
Any cached configuration changes are committed, so they will apply after a
reboot. Without saving, cached configuration changes are lost after a reboot.
Reboots the device. When rebooted, your browser should be refreshed and
redirected to the main status page after 30 seconds.
Reboot (button)
Note: The redirect will not work as expected if the IP address of the devices
change after reboot. After setting the configuration back to factory defaults,
the device will automatically be rebooted. If Web Manager is access through
SoftAP, your connection to SoftAP may be dropped when device reboots.
Restores the device to the original factory settings. All configuration will be
lost. The xPico Wi-Fi automatically reboots upon setting back to the defaults.
Factory Defaults (button)
Device will reboot to the Over-The-Air (OTA) firmware upgrade application to
continue the operation.
Firmware Upload (button)
xPico® Wi-Fi® Embedded Device Server User Guide
49
Download from Www.Somanuals.com. All Manuals Search And Download.
9: Maintenance and Diagnostics Settings
To Save Configuration, Reboot, Restore Factory Defaults or Upload
Firmware
Using Web Manager
To access the area with options to reboot, restore to factory defaults, upload new firmware,
click Device in the menu.
Using CLI
To enter the Device command level: status -> Device
Using XML
Look for the status header: <statusgroup name = "Device”>
Admin User
Table 9-3 Admin User Settings
Description
System Settings
Password
Enter a new password. Users will need to log in again after changing the
password.
To Configure Admin User on the Device
Using Web Manager
To change the password setting, click Users in the menu.
Using CLI
To enter the Users command level: config -> Users
Using XML
Look for the status header: <configgroup name = "Users" instance=”admin”>
xPico® Wi-Fi® Embedded Device Server User Guide
50
Download from Www.Somanuals.com. All Manuals Search And Download.
9: Maintenance and Diagnostics Settings
Diagnostics Settings
The xPico Wi-Fi embedded device server has tools for diagnostics and statistics. Options allow for
the viewing of hardware, IP sockets, threads, and buffer pools.
To View Hardware Status
Using WebManager
To view hardware information, click Diagnostics in the menu and select Hardware.
Using CLI
To enter the Diagnostics command level: status -> Diagnostics
Using XML
Include in your file: <statusgroup name=”Diagnostic Hardware”>
To View IP Socket Status
Using WebManager
To view IP Sockets information, click Diagnostics in the menu and select IP Sockets.
Using CLI
To enter the IP Sockets command level: status -> Diagnostics -> IP Sockets
Using XML
Include in your file: <statusgroup name=”Diagnostics IP Sockets”>
To View Buffer Pool Status
Using WebManager
To view information for each Buffer Pool, click Diagnostics in the menu and select Buffer
Pools.
Using CLI
To enter the Buffer Pools command level: status -> Diagnostics -> Buffer Pools
Using XML
Include in your file: <statusgroup name=”Diagnostic Buffer Pools”
xPico® Wi-Fi® Embedded Device Server User Guide
51
Download from Www.Somanuals.com. All Manuals Search And Download.
10: Advanced Settings
XML Import and XML Export
The xPico Wi-Fi embedded device server allows for the configuration of devices by using XML
configuration records (XCRs). You can export an existing configuration for use on other xPico Wi-
Fi devices or import a saved configuration file. XML import and export are only available through
the CLI.
Note: The xPico Wi-Fi module itself only supports serial TTL signaling on both Lines. If
used with the evaluation board (see the xPico Embedded Device Server Evaluation Kit
User Guide), then Line 2 may be routed through a serial-to-USB converter via jumper
settings.
To ensure optimal performance when configuring and managing the device using XML, it is
required that serial port flow control is enabled. This maybe hardware or soft flow control.
Lantronix recommends the use of hardware flow control to ensure the best throughput.
To Import or Export XML Configuration
1. Connect the xPico Wi-Fi embedded device server to a PC using:
-
-
A null modem cable for line 1.
A USB cable for line 2. The USB driver will automatically install into your PC.
2. Configure command line on line and select hardware or software flow control.
Note: If you are using line 2, select software flow control as hardware flow control is
not supported.
3. Open a terminal emulator from the PC, e.g., Tera Term version 4.58.
4. Select the Com port or USB serial port and set the serial settings, on the terminal emulator, to
match the appropriate line on the device server.
5. When you see prompt ‘>’ on the terminal emulator, type 'h' to view the single character
commands available.
c>h
COMMAND LINE INTERFACE HELP
<tab>
<enter>
*<enter>
?
fill in possible command
run command as edited
show help on matching commands
list matching commands
<left arrow> move cursor left
<right arrow> move cursor right
<up arrow>
previous command
<down arrow> later command
<backspace>
<delete>
delete to left
delete to left
<Paste XML>
import configuration
<control>
<escape>
xPico® Wi-Fi® Embedded Device Server User Guide
52
Download from Www.Somanuals.com. All Manuals Search And Download.
10: Advanced Settings
--------------------------------- ----------------------------------
a move cursor to begin of line
d delete character under cursor f
e move cursor to end of line
k delete to end of line
l redraw line
b
move cursor backward word
move cursor forward word
previous command
later command
move cursor right
move cursor left
[A
[B
[C
[D
r redraw line
u delete to begin of line
w delete word to left
<escape> delete word to left
>
6. Enter XML commands and utilize either xcr dumpor secret xcr dumpto dump xml
configuration information.
7. Copy and paste the configuration text into notepad or some other basic text editor.
8. Remove all the spaces in the script within the text editor. This basic text is the exported XML
configuration and is now available for copy-paste into any xPico Wi-Fi embedded device server.
9. Make any additional changes to the configuration text to modify the XML configuration.
10. Copy and paste <CR> all of the text into the terminal emulator connected to the desired xPico
Wi-Fi embedded device server, to "import" the new configuration.
Note: Software flow control experiences overrun above 460800 baud.
Performance Settings
Change settings pertaining to performance including application, maximum time powered down,
wake-up pin power up, and time powered up.
Table 10-1 Performance Settings
Modem Emulation Settings
Application
Description
Select the performance application:
Tunnel Accept
Tunnel Connect
Command Line
HTTP Server
Any application selected for performance may hold the power on
longer or wake up sooner.
Maximum Time Powered Down
WKUP Pin Power Up
Indicates the maximum amount of time for the device to be
powered down. After this time, the device wakes up.
Enable or disable WKUP pin power up. The device wakes up on
the rising edge of WKUP, if enabled.
Time Powered Up
Indicates the amount of time for the device to be powered up. After
this time, the device powers down.
xPico® Wi-Fi® Embedded Device Server User Guide
53
Download from Www.Somanuals.com. All Manuals Search And Download.
10: Advanced Settings
To Configure Performance
Using Web Manager
To modify performance settings, click Performance in the menu.
Using CLI
To enter the Performance command level: config -> Performance
Using XML
Include in your file: <configgroup name = "Performance"
xPico® Wi-Fi® Embedded Device Server User Guide
54
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
The Monitor feature can be used to query and capture desired information during an xPico Wi-Fi
serial port to serial device connection.
Monitor Settings
Through the Monitor feature in Web Manager, you may configure the monitoring of a connected
serial device through a sequence of five pages via Explorer, or go to a specific Configuration page
to make specific changes. The device monitoring status can be viewed through the Status page.
Note: The easiest way to view monitor status or modify monitor settings is through Web
Manager, however you can also utilize the CLI and XML (see To Configure Monitor on
page 59).
Explorer
Configure the monitoring of a connected serial device through a sequence of pages via Explorer.
Table 11-1 Monitor Explorer Settings
Explorer Settings
Description
Next/Prev (buttons)
Click the Next and Prev button to move between the five pages below, through
which monitor settings are configured:
Step 1: Setup Initiation
Step 2: Setup Commands
Step 3: Define Filters
Step 4: Pick Data
Step 5: Confirm and submit changes
Initial Delay
Set the initial delay time in milliseconds before the monitor starts processing the
initialization message. This field appears in Step 1: Setup Initiation.
Message <Number>
Click the Edit link to edit a specific message; this is where a command is entered.
Four message fields will open to allow configuration of a specific command. When
you begin entering information in these fields, additional Message <Number>
options become available containing the four message fields which will also open
upon clicking Edit. Complete the Message <Number> fields:
Note: In subsequent
screens (Commands/
Control and Poll) in
Explorer or under
Command: enter the command in binary format (printable characters or binary
string)
Configuration,
End Character: indicate as a single printable character or as a control character.
Control characters may be input as <control>J, 0xA(hexadecimal) or \10
(decimal).
Length: set the length of the response. Maximum reponse length is 2048 bytes.
Timeout: set the timeout to receive response. Minimum timeout length is 100
milliseconds.
additional Message
<Number> fields will
become available to
further filter and
specify the information
you wish to monitor.
Click Submit after making changes to get real time response displayed if you are
utilizing Explorer.
xPico® Wi-Fi® Embedded Device Server User Guide
55
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Explorer Settings
Rule <Number>
Description
Click the Edit link to edit a specific rule in the Step 2: Setup Commands page.
Two rule configuration fields will open for this rule. When you begin entering
information in these fields, additional Rule <Number> options become available
containing the two rule configuration fields which will also open upon clicking Edit.
Complete the Rule <Number> fields:
Source: indicate the input of the filter. For example, if the source of this filter is
the second trunk of data created by filter 1, the source should be set to 1.2. A
Source of 0 indicates the raw response.
Mode: select filter mode (All, Delimiters or Binary)
Delimiter <Number> Binary String: Enter the filter breaks input up to 8 trunks
separated by binary string. Each trunk will not contain the delimiters. This field
appears when Delimiter Mode is selected.
Start index: set to indicate when delimiters filter start breaking input into trunks,
if the Delimiter Mode is selected.
Offset: set the size of the first trunik of data created by the binary filter, if
selected.
Length: set the size of the second trunk of data created by the binary filter, if
selected. The third trunk of data created by the binary filter will contain the rest of
the input.
Selector <Number>
Click the Edit link to edit a specific selector in Step 4: Pick Data page. Three
selector configuration fields will open for this selector. When you begin entering
information in these fields, additional Selector <Number> options become
available containing the three selector configuration fields which will also open upon
clicking Edit. Complete the Selector <Number> fields:
Name: define the data name as it will display.
Response: set the response instance source of data. Response instance
corresopnds to poll or control message instance.
Reference: select the output of the monitor filter. For instance, if data should
select the second trunk of data created by filter 1, the reference must be set to
1.2. A Reference of 0 indicaets the raw response.
Display
Select the desired live response to view at any time while using Explorer, of the
monitoring configuration being established. Filter rule options appear according to
your progress establishing commands and rules. Changes in what is displayed can
be useful during the configuration of monitor settings.
Responses 1-4
Filter Rules 1-4 or All Filters
Data (checkbox)
Check the Data checkbox to enable the Display feature anytime using the Explorer.
Uncheck checkbox to disable Display.
xPico® Wi-Fi® Embedded Device Server User Guide
56
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Configuration
Configure the monitoring of a connected serial device through specific configuration settings
pages : Initialization, Control, Poll , Filter, and Data. Access the configuration options displayed in
Setup Initiation if utilizing Explorer.
Table 11-2 Monitor Initialization Settings
Initialization
Settings
Description
Initial Delay
Set the initial delay time in milliseconds before the monitor starts processing the
initialization message. This field also appears in Step 1: Setup Initiation.
Message <Number> Click the Edit link to edit a specific message; this is where a command is entered.
Four message fields will open to allow configuration of a specific command. When
you begin entering information in these fields, additional Message <Number>
Note: In other pages
(Commands/Control
and Poll) in Explorer
or under
Configuration,
additional Message
<Number> fields will
become available to
options become available containing the four message fields which will also open
upon clicking Edit. Complete the Message <Number> fields:
Command: enter the command in binary format (printable characters or binary
string)
End Character: indicate as a single printable character or as a control character.
Control characters may be input as <control>J, 0xA(hexadecimal) or \10
(decimal).
Length: set the length of the response.
Timeout: set the timeout length. Minimum timeout length is 100 milliseconds.
further filter and
specify the information
Click Submit after making changes to get real time response displayed if you are
you wish to monitor.
utilizing Explorer.
configuration fields are the same ones in Step 2: Setup Commands if utilizing Explorer.
Table 11-3 Monitor Control Settings
Control Settings
Description
Message <Number>
Click the Edit link to edit a specific message; this is where a command is entered.
Four message fields will open to allow configuration of a specific command. When
you begin entering information in these fields, additional Message <Number>
options become available containing the four message fields which will also open
upon clicking Edit. Complete the Message <Number> fields:
Note: In other pages
(Commands/Control
and Poll) in Explorer
or under
Command: enter the command in binary format (printable characters or binary
string)
End Character: indicate as a single printable character or as a control character.
Control characters may be input as <control>J, 0xA (hexadecimal)
or \10 (decimal).
Configuration,
additional Message
<Number> fields will
become available to
further filter and
specify the information
you wish to monitor.
Length: set the length of the response.
Timeout: set the timeout length. Minimum timeout length is 100 milliseconds.
Click Submit after making changes to get real time response displayed if you are
utilizing Explorer.
xPico® Wi-Fi® Embedded Device Server User Guide
57
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
fields are the same ones in Step 3: Define Filters if utilizing Explorer.
Table 11-4 Monitor Poll Settings
Poll Settings
Description
Message <Number>
Click the Edit link to edit a specific message; this is where a command is entered.
Four message fields will open to allow configuration of a specific command. When
you begin entering information in these fields, additional Message <Number>
options become available containing the four message fields which will also open
upon clicking Edit. Complete the Message <Number> fields:
Note: In other pages
(Commands/Control
and Poll) in Explorer
or under
Command: enter the command in binary format (printable characters or binary
string)
End Character: indicate as a single printable character or as a control character.
Control characters may be input as <control>J, 0xA(hexadecimal) or \10
(decimal).
Configuration,
additional Message
<Number> fields will
become available to
further filter and
specify the information
you wish to monitor.
Length: set the length of the response.
Timeout: set the timeout length. Minimum timeout length is 100 milliseconds.
Click Submit after making changes to get real time response displayed if you are
utilizing Explorer.
Delay
Set the initial delay time in milliseconds before the monitor starts processing the
initialization message. This field appears in Step 1: Setup Initiation.
fields are the same ones in Step 3: Define Filters if utilizing Explorer.
Table 11-5 Monitor Filter Settings
Filter Settings
Description
Rule <Number>
Click the Edit link to edit a specific rule. Two rule configuration fields will open for
this rule. When you begin entering information in these fields, additional Rule
<Number> options become available containing the two rule configuration fields
which will also open upon clicking Edit. Complete the Rule <Number> fields:
Source: indicate the input of the filter. For example, if the source of this filter is
the second trunk of data created by filter 1, the source should be set to 1.2. A
Source of 0 indicates the raw response.
Mode: select filter mode (All, Delimiters or Binary)
Delimiter <Number> Binary String: Enter the filter breaks input up to 8 trunks
separated by binary string. Each trunk will not contain the delimiters. This field
appears when Delimiter Mode is selected.
Start index: set to indicate when delimiters filter start breaking input into trunks,
if the Delimiter Mode is selected.
Offset: set the size of the first trunik of data created by the binary filter, if
selected.
Length: set the size of the second trunk of data created by the binary filter, if
selected. The third trunk of data created by the binary filter will contain the rest of
the input.
xPico® Wi-Fi® Embedded Device Server User Guide
58
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
fields are the same ones in Step 4: Pick Data if utilizing Explorer.
Table 11-6 Monitor Data Settings
Data Settings
Description
Selector <Number>
Click the Edit link to edit a specific selector. Three selector configuration fields will
open for this selector. When you begin entering information in these fields,
additional Selector <Number> options become available containing the three
selector configuration fields which will also open upon clicking Edit. Complete the
Selector <Number> fields:
Name: define the data name as it will display.
Response: set the response instance source of data. Response instance
corresopnds to poll or control message instance.
Reference: select the output of the monitor filter. For instance, if data should
select the second trunk of data created by filter 1, the reference must be set to
1.2. A Reference of 0 indicaets the raw response.
To Configure Monitor
The easiest way to view monitor status or modify monitor settings is through Web Manager,
however you can also utilize the CLI and XML.
Using Web Manager
To view monitor status or modify monitor settings, go to Monitor on the menu.
Using CLI
To enter the Monitor command level: config -> Monitor
Using XML
Include in your file: <configgroup name = "Monitor" instance = “1”>
Include in your file: <configgroup name = "Monitor Initialization" instance =
“1”>
Include in your file: <configgroup name = "Monitor Control" instance = “1”>
Include in your file: <configgroup name = "Monitor Poll" instance = “1”>
Include in your file: <configgroup name = "Monitor Filter" instance = “1”>
Include in your file: <configgroup name = "Monitor Data" instance = “1”>
xPico® Wi-Fi® Embedded Device Server User Guide
59
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Example: Data Capture on a Serial Device
Connect the xPico Wi-Fi serial port to a serial device, then query and capture desired information
periodically, presenting this information on a Web page.
Sample Configuration
Connect to the Command Line Interface (CLI) on the EDS2100. The CLI has menu levels, so
we will send commands to exit through multiple levels, knowing that an exit at the top level will
just return us to the top level. Then we can enter the "enable" command level.
Use a null modem cable to connect xPico Wi-Fi unit Line 1 to a Lantronix EDS2100 Line 1.
Set both devices to 115200 bits per second, no parity, 8 data bits, 1 stop bit, hardware flow
control.
Set the first three message Commands to send "exit[0x0d]", the fourth "enable[0x0d]"
Initialization
Upon xPico Wi-Fi power-up, the state of the external serial device is not known. Monitor will send
one or more messages to bring the serial device into a known state.
STEP 1 - STRATEGY
Figure 11-7 Monitor Initialization
Explore your serial device and determine your
strategy for bringing it to the desired starting state.
STEP 2 - CONNECTION
Connect your serial device to your xPico Wi-Fi unit.
STEP 3 - LINE SETTINGS
Set serial line speed, flow control, and character
options on both devices so they are compatible. On
xPico Wi-Fi unit, select "Monitor" under Line Protocol.
STEP 4 - MONITOR INITIALIZATION
Use Monitor Explorer or directly configure settings in
Monitor Initializationthe example configuration is typed
into the Monitor Explorer web page.
Note: Non-printable characters are placed in the
Command within square brackets. The "Enter" key on
your PC is an ASCII Carriage Return, code 0x0d.
Note: After each message Command is sent, the Monitor may wait for a response. You
may set the Timeout for each message. If the Timeout is too short, your device may
become out of sync with Monitor. So make your timeout comfortably high, and then if
applicable define an End Character or Length so it will move on without waiting further.
xPico® Wi-Fi® Embedded Device Server User Guide
60
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Figure 11-8 Monitor Polling (1 of 2)
Polling
Periodically your xPico Wi-Fi will send commands to
query information from your serial device.
STEP 1 - STRATEGY
Explore your serial device and determine your
strategy for eliciting all of the desired data with the
fewest message Commands.
STEP 2 - SETUP
Use Monitor Explorer or directly configure settings in Monitor Poll Configuration. For each
message Command, determine an appropriate Timeout and possibly shorten it via a Length and/
or End Character.
STEP 3 - TEST
Testing is rapid and simplified using Monitor Explorer.
You can see the serial device response right in your
browser window.
Figure 11-9 Monitor Polling (2 of 2)
Sample Configuration
Use a single "show" command to elicit the
EDS2100 device status.
In Monitor Poll Configuration, set Message 1
Command to "show[0x0d]".
Testing with this, notice that the default Timeout of
100 milliseconds is too fast-we sometimes poll
before all the data comes out. So we set Timeout
to 200 milliseconds for stable operation.
Note: It is possible to poll with more than one message Command. They will be sent
sequentially, and you will define distinct filtering and data mining steps for each.
xPico® Wi-Fi® Embedded Device Server User Guide
61
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Figure 11-10 Monitor Filtering (1 of 2)
Filtering
The response to each poll will be sliced up according
to your filter rules. The objective is to simply slice
enough so you can subsequently point to the data
fields you want to mine.
Note the raw data in the grey box above; it reflects
what was received from the serial device. See
"Uptime" in the top right region-that's our target for the
example.
STEP 1 - STRATEGY
Carefully examine the form of the response you
received from a particular poll. Look for cues in the
response to locate your desired information. Consider
if the form of the response might have variations
depending on the serial device state.
STEP 2 - SETUP
Use Monitor Explorer or directly configure settings in Monitor Filter Configuration. Rules are
performed sequentially, but note that you can point each Rule to either the raw source (0) or a
result of a previous rule (R.f). Each rule (R) slices the raw input into multiple fields (f), so with a dot
between them (R.f) you are selecting a particular sliced result from a Rule.
STEP 3 - TEST
Testing is rapid and simplified using Monitor Explorer. You can see the response data sliced into
pieces right in your browser windows.
Sample Configuration
First slice the response into lines, point to the one
containing Uptime, then slice between the caption
and the time value.
Figure 11-11 Monitor Filtering (2 of 2)
Setup as follows:
-
We could see the Carriage Return / Line Feed
sequence in our raw source.
-
Rule 1 points to the raw source (Source 0),
Mode = Delimiters, Delimiter 1 Binary String =
"[0x0d 0x0a]".
-
-
We can see our Uptime is in the sixth field.
Rule 2 dices that field (Source 1.6) further, to
split the caption from the value.
-
-
We see that a colon (:) separates the caption
from the data, but the data also contains colons.
Rule 2 Mode - Delimiters, Delimiter 1 Binary String = " :" (that's a space followed by a
colon). We use the space so it will match the transition from caption to value, but not
match within the Uptime value itself.
Testing with this, confirm that the desired data is contained in a single field.
xPico® Wi-Fi® Embedded Device Server User Guide
62
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Note: Some devices might use a variable number of lines to display status depending
on the device state. If so, slicing first by lines will not consistently point to the desired data.
Instead, consider a different strategy:
Rule 1 can use Mode = Delimiters, but set the Delimiter 1 Binary String = caption.
Its field 2 contains all of the response following the caption.
Use Rule 2 or more to further slice 1.2 (Rule 1 field 2) in order to separate the value from
anything following the caption and from the rest of the response.
Data Mining
You have already sliced the raw data multiple ways
using the Filter Steps. Now you will select the data to
be mined.
Figure 11-12 Monitor Data Mining (1 of 2)
STEP 1 - STRATEGY
You can have multiple Poll messages, and different
Filter Steps will generally apply to each, but some
Filter Steps may be shared. Here is where you put it
all together. The neat thing is that all the slicing of the
raw data is virtual, so all of your Filter Rules overlay
raw data from each response, but you need only care
about some of them on a particular Poll message.
STEP 2 - SETUP
Use Monitor Explorer or directly configure settings in Monitor Data Configuration. Each Selector
picks out a distinct data item you wish to subsequently present. The Selector Name will be
presented as the caption for your data. Selector Response is a Message number; it selects the
response from that Message. Selector Reference is a Rule number, dot, and a field number; it
selects the desired data field.
Bottom line, you have placed a stake in the ground
naming a result, identifying which poll response it
comes from, and which field to pick up.
Figure 11-13 Monitor Data Mining (2 of 2)
STEP 3 - TEST
Testing is rapid and simplified using Monitor Explorer.
You can see the selected field contents right in your
browser window.
Sample Configuration
We'll name our result "Up time". It goes in Monitor
Data Configuration under "Name".
We only used one Poll message, so "Response"
is just "1".
Our desired data is from Rule 2, field 2. So
"Reference" is "2.2".
xPico® Wi-Fi® Embedded Device Server User Guide
63
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Presenting
STEP 1 - STRATEGY
Here you consider your options for sharing the data
you have mined. For human users, a Web page
presentation is simplest. For machine-to-machine
communication, XML might be best. Command Line
could be used for either.
Figure 11-14 Monitor Presenting
STEP 2 - SETUP
Automatically your data is available under status on
the Web Manager, XML, and CLI.
Advanced Web customization can be done with HTML and JavaScript files dropped into the xPico
Wi-Fi unit.
STEP 3 - TEST
With the Web Manager, view all of your data under Monitor Status.
In the Command Line Interface (CLI), first type "status" to enter the status menu level, then type
"monitor" for the Monitor menu level. From there, type "show" for the data.
In the XML status dump, find statusgroup name = "Monitor", then statusitem name = "data"
instance = "<the name you gave your data>", and value contains the data received.
Sample Configuration
We visit our device Web Manager, select the "Monitor" tab at the left of the display, the select
"Status" at the top of the display. Our "Up time" and the present value appear there.
Figure 11-15 Monitor CLI Command Level
Visiting the Command Line Interface, we type "status", then "monitor", then "show". We see
"Up time" presented there.
xPico® Wi-Fi® Embedded Device Server User Guide
64
Download from Www.Somanuals.com. All Manuals Search And Download.
11: Monitor
Figure 11-16 Monitor XML Commands
For XML we start at the root Command Line Interface, type "xml", then "xsr dump monitor".
We see a statusitem name = "data", instance = "Up time", with value containing the present
data.
DATA CAPTURE ON SPI
Connect xPico Wi-Fi SPI port to peripheral device, query and capture desired information
periodically, present on Web page.
xPico® Wi-Fi® Embedded Device Server User Guide
65
Download from Www.Somanuals.com. All Manuals Search And Download.
12: Branding the xPico Wi-Fi Unit
This chapter describes how to brand the Web Manager user interface of your xPico Wi-Fi
embedded device server.
Web Manager Customization
Changing the Presentation
You can customize the Web Manager's appearance by modifying index.htmland style.css.
The style (fonts, colors, and spacing) of the Web Manager is controlled with style.cssand the
text and graphics are controlled with index.html.
The Web Manager files are hidden and are incorporated directly into the firmware image but may
be overridden by placing the appropriate file in the appropriate directory within the xPico Wi-Fi file
system.
Web Manager files can be overridden with the following procedure:
1. Either create a file from scratch, or edit a copy of the existing Lantronix file. To edit a copy of
the original file, do the following:
a. Obtain the file by entering the following path in a browser:
http://<hostname>/lantronix/resource/main/web_manager/web/<filename>
b. Then save the file (in the case of index.html, you may need to set the browser to view the
page source).
c. Modify the file as required.
2. Create a path in the file system (the entire path can be created in a single step via either the
Web Manager or CLI). The path is the same as that for the hidden files, except for the top-level
/lantronix directory:
/resource/main/web_manager/web/
3. Upload your file into the directory in step 2.
4. Restart the browser to view the changes.
To go back to the default files in the firmware image, simply delete the overriding files in the file
system (the directories can be left intact if so desired).
Path Format
As mentioned above, the root directory for hidden files built into the firmware is /lantronix. When
overriding these hidden files by placing your own copies in the file system, the path is identical but
for the /lantronixtop directory. For example, the built-in hidden file /lantronix/
resource/main/web_manager/web/index.htmlis overridden by the real file system file
/resource/main/web_manager/web/index.html.
If you need to refer to an overridden file within your own web files, the path follows the same
format, except the /lantronixtop directory of the hidden file path is replaced by /.overlay.
So, to refer to style.css from within index.html, the path in index.html is /.overlay/resource/
main/web_manager/web/index.html. This format allows the system to look first for an
overriding copy of the file before using the built-in copy.
xPico® Wi-Fi® Embedded Device Server User Guide
66
Download from Www.Somanuals.com. All Manuals Search And Download.
12: Branding the xPico Wi-Fi Unit
Note: This path schema is subject to change in the future.
Other Overridable Files
In addition to index.html, and style.css, a few other presentation-related files can be overridden.
The complete list is as follows:
/resource/main/web_manager/web/index.html - Main file controlling text and graphics
/resource/main/web_manager/web/style.css - Style sheet
/resource/main/web_manager/web/img/bg.gif - Main background
/resource/main/web_manager/web/img/company_logo.gif - Company logo in header container
/resource/main/web_manager/web/img/favicon.ico - Shortcut icon
/resource/main/web_manager/web/img/header_bg.gif - Head container background
xPico® Wi-Fi® Embedded Device Server User Guide
67
Download from Www.Somanuals.com. All Manuals Search And Download.
13: Updating Firmware
Obtaining Firmware
Obtain the most up-to-date firmware and release notes for the unit from the Lantronix Web site
(www.lantronix.com/support/downloads/) or by using anonymous FTP (ftp://ftp.lantronix.com/).
Loading New Firmware through Web Manager
Upload the firmware using the device Web Manager Device page.
To upload new firmware:
1. Select Device in the menu bar. The Device Status page appears.
debice.
Figure 13-1 Uploading New Firmware
2. Click Firmware Upload.
3. Click Okay to confirm uploading a new firmware image. You will be redirected to the Firmware
Upgrade page.
4. Click Browse... to browse to the firmware file.
xPico® Wi-Fi® Embedded Device Server User Guide
68
Download from Www.Somanuals.com. All Manuals Search And Download.
13: Updating Firmware
5. Select the file and click Open.
6. Click Upgrade to install the firmware on the xPico Wi-Fi embedded device server.
7. Click OK in the confirmation pop-up which appears. The firmware will be installed and the
device will automatically reboot afterwards.
8. Close and reopen the Web Manager internet browser to view the device’s updated web pages.
xPico® Wi-Fi® Embedded Device Server User Guide
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
The xPico Wi-Fi embedded device server supports three convenient configuration methods: Web
Manager, Command Line Interface (CLI) and Extensible Markup Language (XML). This appendix
describes how to configure the xPico Wi-Fi embedded device server using the Command Line
Interface (CLI) and/or Extensible Markup Language (XML). CLI provides an interactive mode for
accessing the device configuration and management interface. It is most suited for system and
network administrators comfortable with using similar interfaces on Enterprise IT and Networking
products. It is also helpful as a quick tool for access via the product's serial ports or console/
management ports. XML provides an extensible mode for software developers.
For more information about the Web Manager, see the Chapter 3: Configuration Using Web
Conventions
The table below lists and describes the conventions used in this book.
Convention
Description
Bold text
Italic text
Brackets [ ]
Default parameters.
Required values for parameters
Optional parameters.
Angle Brackets < >
Pipe |
Possible values for parameters.
Choice of parameters.
Warning
Warning:
Means that you are in a situation that could cause
equipment damage or bodily injury. Before you work on any
equipment, you must be aware of the hazards involved with electrical
circuitry and familiar with standard practices for preventing accidents.
Note
Note: Means take notice. Notes contain helpful suggestions, information,
or references to material not covered in the publication.
Caution
Caution: Means you might do something that could result in faulty
equipment operation, or loss of data.
Screen Font
(Courier New)
CLI terminal sessions and examples of CLI input.
XML Architecture and Device Control
XML is a fundamental building block for the future growth of Machine-to-Machine (M2M) networks.
The xPico Wi-Fi embedded device server supports XML configuration records that make
configuring the device server easy for users and administrators. XML configuration records are
easy to edit with a standard text editor or an XML editor.
a guide to the specific XML tags used, and a guide to using XML configuration records.
xPico® Wi-Fi® Embedded Device Server User Guide
70
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
Configuration Using Serial Port
Serial Command Mode
The serial port can be configured to operate in command mode permanently or to be triggered
under specified conditions. See the line <line> Levelcommand description for more
information.
Boot to CLI
Regardless of the configured settings, the CLI can be accessed via Line 1 using fixed settings and
the "back door" procedure. The original configured line settings will be restored once the user exits
the "back door" CLI, unless any Line 1 settings are changed within the "back door" CLI.
To configure the Lantronix xPico Wi-Fi embedded device server locally using a serial port:
Note: The xPico Wi-Fi embedded device server requires that flow control be used on the
serial port to ensure the best performance when importing XML.
1. Connect a terminal or a PC running a terminal emulation program to one of the xPico Wi-Fi
embedded device server's serial ports.
2. Configure the terminal to the following settings:
9600 baud
8-bit
No parity
1 stop bit
Flow control enabled
Note: Lantronix recommends using hardware flow control.
3. Power off the device.
4. Get into the serial backdoor as follows:
a. While asserting the defaults signal,
b. Reset the device while sending X, Y, or Z characters.
c. When the incoming characters are recognized, a prompt in the following form will be seen:
xPicoWifi <MAC ADDRESS>
Note: It is important to release the defaults signal as soon as possible after the
prompt is seen; continuing to hold it down may result in a reset to factory defaults.
OR
a. While asserting the defaults signal,
b. Reset the device while sending ! character until it is echoed back.
c. Then release the defaults line, and enter xyz.
xPico® Wi-Fi® Embedded Device Server User Guide
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
Navigating the CLI Hierarchy
The CLI is organized into a hierarchy of levels. Each level has a group of commands for a specific
purpose. For example, to view diagnostic or device status, one would navigate to the statuslevel
where they could then navigate to diagnosticsor device.
To move to a different level—Enter the name of the level from within its parent level. For
example, to enter the file system level, type file systemat the enable prompt.
To exit and return to one level higher—Type exitand press the Enter key.
To view the current configuration, enter the config level by typing config.
To view the list of commands available at the current level—Type the question mark ?. Items
within < > (e.g. <string>) are required parameters.
To view the available commands and explanations—Type the asterisk (*).
To view the list of commands available for a partial command—Type the partial command
followed by the question mark "?". For example: config>?displays a list of all config
commands at the config level.
To view available commands and their explanations for a partial command—Type an asterisk
(*). For example: config Access Point>* displays a list of all accesss point commands
and descriptions at the config > access point level.
To view SPI configurations, enter the config level by typing configat the root level, and then
the SPI level by typing SPI.
To view the tlog, type tlog or t at the root level.
Using Keyboard Shortcuts and CLI
One useful shortcut built into xPico Wi-Fi embedded device server is that the complete text of a
command does not have to be entered to issue a command. Typing just enough characters to
uniquely identify a command, then hitting enter, can be used as a short cut for a command. For
example, at the enable level, "sh" can be used for the "show" command.
Tab Completion is also available using the Tab and Enter keys on the keyboard. Typing the first
few characters of a command, then hitting the Tab key displays the first command that begins with
those characters. Hitting the Tab key again displays the next command that begins with the
original characters typed. You can press Enter to execute the command or you can backspace to
edit any parameters.
The following key combinations are allowed when configuring the Pico Wi-Fi embedded device
server using the CLI:
Table A-1 Keyboard Shortcuts
Key Combination
Ctrl + a
Description
Places cursor at the beginning of a line
Backspaces one character
Deletes one character
Ctrl + b
Ctrl + d
Ctrl + e
Places cursor at the end of the line
Moves cursor forward one character
Ctrl + f
xPico® Wi-Fi® Embedded Device Server User Guide
72
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
Key Combination (continued) Description
Ctrl + k
Ctrl + l
Ctrl + n
Ctrl + p
Ctrl + u
Ctrl + w
Ctrl + z
Deletes from the current position to the end of the line
Redraws the command line
Displays the next line in the history
Displays the previous line in the history
Deletes entire line and places cursor at start of prompt
Deletes one word back
Exits the current CLI level
Understanding the CLI Level Hierarchy
The CLI hierarchy is a series of levels. Arranging commands in a hierarchy of levels provides a
way to organize and group similar commands, provide different levels of security, and reduce the
complexity and number commands and options presented to a user at one time.
When you start a command line session, you begin at the root level. This level can be password
protected and provides access to high level status, a few diagnostic commands, and the file
system level. Further device information and configuration are accessed via the enable level.
The enable level can also be password protected and is the gateway to full configuration and
management of the xPico Wi-Fi embedded device server. There are commands for gathering and
effecting all elements of device status and configuration, as well as commands that take you to
additional levels. For instance, tunnel specific status and configuration is found under the "tunnel"
level, and network specific status and configuration commands are found under the "configuration"
level.
configuration settings and are not displayed initially. If you type ?, you will see the login sub-
commands. These commands provide diagnostic and status information only.
Figure A-2 Root Level Commands
>?
config
help
tlog
xml
file system
status
wlan scan [network-name]
exit
Configuration Using XML
The xPico Wi-Fi embedded device server provides an Extensible Markup Language (XML)
interface that you can use to configure xPico Wi-Fi embedded device servers. Every configuration
setting, excluding XML import and export, that can be issued from the xPico Wi-Fi Web Manager
and CLI can be specified using XML.
The XPico Wi-Fi embedded device server can import and export configuration settings as an XML
document known as an XML Configuration Record (XCR). An XCR can be imported or exported
via the CLI or the xPico Wi-Fi embedded device server filesystem. An XCR can contain many
configuration settings or just a few. For example, it might change all of the configurable
xPico® Wi-Fi® Embedded Device Server User Guide
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
parameters for a xPico Wi-Fi embedded device server, or it may only change the baud rate for a
single serial line. Using XCRs is a straightforward and flexible way to manage the configuration of
multiple XPico Wi-Fi embedded device servers.
XML Configuration Record Document Type Definition
An XML document type definition (DTD) is a description of the structure and content of an XML
document. It verifies that a document is valid. XCRs are exported using the DTD as shown in
Figure A-3 DTD for XCRs
<!DOCTYPE configrecord [
<!ELEMENT configrecord (configgroup+)>
<!ELEMENT configgroup (configitem+,configgroup*)>
<!ELEMENT configitem (value+)>
<!ELEMENT value (#PCDATA)>
<!ATTLIST configrecord version CDATA #IMPLIED>
<!ATTLIST configgroup name CDATA #IMPLIED>
<!ATTLIST configgroup instance CDATA #IMPLIED>
<!ATTLIST configitem name CDATA #IMPLIED>
<!ATTLIST value name CDATA #IMPLIED>
]>
The xPico Wi-Fi DTD rules state the following:
The XML document element is a <configrecord>element. This is the root element.
A <configrecord>must have one or more <configgroup>elements and can have a
version attribute.
A <configgroup>must have one or more <configitem>elements and can have name
and instance attributes.
A <configitem>element must have one or more <value> elements and can have a name
attribute.
A <value>element can have only data and can have a name attribute.
The name attribute identifies a group, item, or value. It is always a quoted string.
The instance attribute identifies the specific option, like the serial port number. The "instance"
attribute is always a quoted string.
Note:
The name for each <configgroup> (specified with the name attribute) is the group
name listed in the Web Manager XCR groups or with the "xcr list" CLI command. See
the xPico Wi-Fi Embedded Device Server User Guide for more information about the
XCR groups.
xPico® Wi-Fi® Embedded Device Server User Guide
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
An empty or missing <value> element in each present <configgroup> clears the
setting to its default.
Quick Tour of XML Syntax
Declaration
The first line, <?xml version="1.0" standalone="yes"?>, is called the XML declaration.
It is required and indicates the XML version in use (normally version 1.0). The remainder of the file
consists of nested XML elements, some of which have attributes and content.
Element Start and End Tags
An element typically consists of two tags: start tag and an end tag that surrounds text and other
elements (element content). The start tag consists of a name surrounded by angle brackets, for
example <configrecord>. The end tag consists of the same name surrounded by angle
brackets, but with a forward slash preceding the name, for example </configrecord>. The
element content can also contain other "child" elements.
Element Attributes
The XML element attributes that are name-value pairs included in the start tag after the element
name. The values must always be quoted, using single or double quotes. Each attribute name
should appear only once in an element.
Figure A-4 shows an XML example which consists of a declaration (first line), nested elements
with attributes and content.
Figure A-4 XML Example
<configgroup name = "HTTP Server">
<configitem name = "State">
<value>Enabled</value>
</configitem>
<configitem name = "Port">
<value>80</value>
</configitem>
<configitem name = "Inactivity Timeout">
<value>5 minutes</value>
</configitem>
<configitem name = "Access Control" instance = "1">
<value name = "URI">/</value>
<value name = "AuthType">Basic</value>
<value name = "Users">admin</value>
</configitem>
</configgroup>
The xPico Wi-Fi embedded device server uses the attributes in the following subsections to label
the group configuration settings.
xPico® Wi-Fi® Embedded Device Server User Guide
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
Record, Group, Item, and Value Tags
A <configgroup> is a logical grouping of configuration parameters and must contain one or
more <configitem> elements. It must have a name attribute and may have an instance
attribute.
A <configitem>is a specific grouping of configuration parameters relevant to its parent group.
An item takes the name attribute and must contain one or more value elements. For example, the
line group might have parameters such as baud rate, data bits, and parity.
A value may specify the value of a configuration parameter. It may contain the name attribute. In
this example, a value of 9600 might be specified for baud rate; 7 may be specified for data bits,
and even may be specified for parity
A name attribute identifies the group, item, or value. It is always quoted (as are all XML attributes).
For example,a group that contains serial port parameters has the name "line"
An instance attribute identifies which of several instances is being addressed. It is always quoted.
For example,the serial port name (in the line configgroup) has the instance "1" to indicate serial
port 1 or "2" to specify serial port 2
The following figures show examples of XML configuration records and the use of the
<configrecord>, <configgroup>, <configitem>, and <value>XML elements.
Figure A-5 XML Example
<configrecord version = "0.1.0.1">
<configgroup name = "Access Point" instance = "ap0">
<configitem name = "SSID">
<value>XpicoWiFi_98010B</value>
</configitem>
<configitem name = "Channel">
<value>1</value>
</configitem>
<configitem name = "Suite">
<value>WPA2</value>
</configitem>
<configitem name = "Encryption">
<value>CCMP</value>
</configitem>
<configitem name = "Passphrase">
<value><Configured></value>
</configitem>
<configitem name = "Mode">
<value>Always Up</value>
</configitem>
</configgroup>
xPico® Wi-Fi® Embedded Device Server User Guide
76
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
XML for xPicoWi-Fi Embedded Device Server
configgroup Access Point
These settings pertain to the Access Point in the device. Changes will take effect after reboot.
configitem SSID
value
The default value of SSID is XpicoWiFi_hhhhhh, where hhhhhh are the last 6 hex digits from the BSSID.
Blank the value to restore the default.
SSID may contain up to 32 characters.
configitem Channel
value
No help available.
value
Suite may be "None", "WPA" or "WPA2".
configitem Encryption
value
Encryption may contain any combination of "CCMP" or "TKIP".
configitem Passphrase
value
Passphrase may contain up to 63 characters.
The value is HIDDEN.
configitem Mode
value
Mode may be "Always Up" or "Triggered".
configitem Uptime
value
Uptime has units of seconds.
configgroup CPM
These settings pertain to the Configurable Pin Manager (CPM). Changes take effect immediately.
configitem Role
value Instance
Instance may contain up to 32 characters.
xPico® Wi-Fi® Embedded Device Server User Guide
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
value CP
This is the number of the Configurable Pin (CP) assigned to the role.
Enter blank or 0 to revert to <No CP Selected>.
Blank the value for "<No CP Selected>".
value State
The Enabled State allows the application to use the designated Configurable Pin.
Note that some Roles (those containing a ".") are bundled into a group. Enabling / Disabling any one of
them also Enables / Disables the rest of the Roles in the same Group.
State may be "Enabled" or "Disabled".
value Assert
Assert reflects the logical polarity of this Configurable Pin.
High means that a logical "1" corresponds to a voltage high condition on the pin.
Low means that a logical "1" corresponds to a voltage low condition on the pin.
Assert may be "High" or "Low".
value Mode
Mode indicates if this Configurable Pin is set up for push-pull or if it enables an internal weak pullup.
5-Volt tolerance: In order to sustain a voltage higher than VDD+0.3, the Mode must be set to Push-Pull.
Mode may be "Push-Pull" or "Weak Pullup".
configgroup HTTP Server
These settings pertain to the HTTP Server. Changes will take effect after reboot.
configitem State
value
Enable the State to allow the HTTP Server to operate.
Disable the State to prevent HTTP from operating on any port.
State may be "Enabled" or "Disabled".
configitem Port
value
The Port can be overridden. Blank the display to restore the default.
Zero the value for "<None>".
configitem Inactivity Timeout
value
The Inactivity Timeout applies only if the Application "HTTP Server" is enabled in Performance.
The HTTP Server will hold power on this long after it completes a request.
Inactivity Timeout has units of seconds.
xPico® Wi-Fi® Embedded Device Server User Guide
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Access Control
value URI
The URI must begin with /to refer to the file system.
URI may contain up to 255 characters.
value AuthType
The different AuthType values offer various levels of security. From the least to most secure:
None
no authentication necessary
Basic
encodes passwords using Base64
There is no real reason to create an authentication directive using None unless you want to override a
parent directive that uses some other AuthType.
AuthType may be "None" or "Basic".
value Users
Users may contain up to 54 characters.
configgroup Interface
These settings pertain to the Network Interface on the device. To see the effect of these selections after a
reboot, view the corresponding Status. Changes will take effect after reboot.
When an Access Point is enabled, DHCP Server will assign IP addresses to the access point's clients.
DHCP Server manages up to 4 client IP addresses (only 3 if wlan0 is enabled). The first IP Address will be
the Access Point's IP Address plus one. For example, if the Access Point's IP Address is 192.168.0.1, the
client addresses will range from 192.168.0.2 to 192.168.0.5.
configitem State
value
Enable the State to allow the Interface to operate.
State may be "Enabled" or "Disabled".
configitem DHCP Client
value
If DHCP Client is enabled, any configured IP Address, or Default Gateway will be ignored. DHCP Client
will auto-discover and eclipse those configuration items. Hostname is sent to the remote DHCP Server and
may figure into the address assignment.
When DHCP Client fails to discover an IP Address, a new address will automatically be generated using
AutoIP. This address will be within the 169.254.x.x space.
This setting is not applicable to the Access Point.
DHCP Client may be "Enabled" or "Disabled".
xPico® Wi-Fi® Embedded Device Server User Guide
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem IP Address
value
IP Address may be entered alone, in CIDR form, or with an explicit mask:
192.168.1.1 (default mask)
192.168.1.1/24 (CIDR)
192.168.1.1 255.255.255.0 (explicit mask)
The IP Address will be displayed always in CIDR, the canonical form.
IP Address may contain up to 31 characters.
configitem Default Gateway
value
The Default Gateway is used only if DHCP Client is disabled, and provides the IP Address of the router.
This setting is not applicable to the Access Point.
Default Gateway may contain up to 15 characters.
configitem Hostname
value
Hostname must begin with a letter or number, continue with letter, number, or hyphen, and must end with
a letter or number.
If DHCP Client is enabled, the Hostname is sent to the remote DHCP Server and may figure into the
address assignment.
This setting is not applicable to the Access Point.
Hostname may contain up to 63 characters.
configitem Primary DNS
value
The Primary DNS is the first choice when performing a Domain Name lookup.
This setting is not applicable to the Access Point.
Primary DNS may contain up to 15 characters.
configitem Secondary DNS
value
The Secondary DNS is the second choice when performing a Domain Name lookup.
This setting is not applicable to the Access Point.
Secondary DNS may contain up to 15 characters.
configgroup Line
These settings pertain to the Serial Line. Changes take effect immediately.
xPico® Wi-Fi® Embedded Device Server User Guide
80
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Name
value
The Name is for display purposes only.
Name may contain up to 25 characters.
configitem State
value
Enable the State to allow the Serial Line to operate.
State may be "Enabled" or "Disabled".
configitem Protocol
value
Protocol selects the application to connect to the Line:
None selects no application to connect to the Line.
Tunnel sets up the Line to work with the Tunnel application. See the Tunnel configuration options for
details.
Trouble Log sets up an output-only message log on the device. Severity codes in the log are:
P Emergency
A Alert
C Critical
E Error
W Warning
N Notice
I Informational
D Debug
Command Line sets up a user interface containing commands to show device status and to change
configuration. Simply paste in XML configuration to apply its settings to the device.
Protocol may be "Command Line", "Modem Emulation", "Monitor", "None", "Trouble Log" or "Tunnel".
configitem Baud Rate
value
When specifying a Custom baud rate in the Web Manager, select 'Custom' from the drop down list and
then enter the desired rate in the text box.
Baud Rate has units of bits per second.
configitem Parity
value
Parity may be "None", "Even" or "Odd".
configitem Data Bits
value
Data Bits may be "7" or "8".
xPico® Wi-Fi® Embedded Device Server User Guide
81
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Stop Bits
value
Stop Bits may be "1" or "2".
configitem Flow Control
value
Flow Control may be "None", "Hardware" or "Software".
configitem Xon Char
value
When specifying Xon Char, prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control
character with <control>. These are used when Flow Control is set to Software.
Xon Char may contain one character, where <control>J, for example, counts as one.
configitem Xoff Char
value
When specifying Xoff Char, prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control
character with <control>. These are used when Flow Control is set to Software.
Xoff Char may contain one character, where <control>J, for example, counts as one.
configitem Gap Timer
value
The driver forwards received serial bytes after the Gap Timer delay from the last character received. By
default, the delay is four character periods at the current baud rate (minimum 1 ms).
Gap Timer has units of milliseconds.
Blank the value for "<Four Character Periods>".
configitem Threshold
value
The driver will forward received characters after Threshold bytes have been received.
Threshold has units of bytes.
configgroup Performance
These settings pertain to Performance. Changes take effect immediately.
The device wakes up either on the rising edge of WKUP, if enabled, or after being down Maximum Time
Powered Down.
The device powers down after Time Powered Up.
However, if any Application is selected, the application may hold power on longer or wake up sooner.
configitem Application
value Instance
Instance matches the name of a registered application.
xPico® Wi-Fi® Embedded Device Server User Guide
82
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
Instance may contain up to 32 characters.
value State
Enable the State to allow the named Application to hold power on.
State may be "Enabled" or "Disabled".
configitem Maximum Time Powered Down
value
Maximum Time Powered Down has units of seconds.
Blank the value for "<Infinite>".
configitem WKUP Pin Power Up
value
WKUP Pin Power Up may be "Enabled" or "Disabled".
configitem Time Powered Up
value
Time Powered Up has units of seconds.
Blank the value for "<Infinite>".
configgroup SPI
These settings pertain to the Serial Peripheral Interface (SPI) Bus Master device. Changes take effect
immediately.
configitem Name
value
The Name is for display purposes only.
Name may contain up to 25 characters.
configitem State
value
State selects the operating state of the SPI:
Enabled enables the SPI.
Disabled disables the SPI.
State may be "Enabled" or "Disabled".
configitem Protocol
value
Protocol selects the application to connect to the SPI:
None selects no application to connect to the SPI.
Monitor selects the Monitor application to connect to the SPI.
Protocol may be "None" or "Monitor".
xPico® Wi-Fi® Embedded Device Server User Guide
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Target Speed
value
Target Speed selects the target clock speed of the SPI.
The Target Speed may be lowered to the closest Operating Speed capability of the device. If so, a
warning will be noted.
0 or clearing the selection selects the minimum speed.
Target Speed has units of Hz.
Blank the value for "<Minimum>".
configitem Idle Clock Level
value
Idle Clock Level, also known as Clock Polarity or CPOL, selects the level of the clock when idle:
Low means the idle clock is at a low level. This is equivalent to CPOL=0.
High means the idle clock is at a high level. This is equivalent to CPOL=1.
Idle Clock Level may be "Low" or "High".
configitem Clock Edge
value
Clock Edge, also known as Clock Phase or CPHA, selects the clock edge for latching data:
First means each bit is latched on the first edge of the clock. This is equivalent to CPHA=0. When Idle
Clock Level is Low, data is latched on the rising edge. When Idle Clock Level is High, data is latched on
the falling edge.
Second means each bit is latched on the second edge of the clock. This is equivalent to CPHA=1. When
Idle Clock Level is Low, data is latched on the falling edge. When Idle Clock Level is High, data is
latched on the rising edge.
Clock Edge may be "First" or "Second".
configitem Bits Per Word
value
Bits Per Word selects the number of bits per word of transfer.
Bits Per Word may be "8" or "16".
configitem First Transfer
value
First Transfer selects the first transfer bit of each word.
First Transfer may be "Most Significant Bit" or "Least Significant Bit".
configgroup Users
These settings pertain to Users on the device.
xPico® Wi-Fi® Embedded Device Server User Guide
84
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Instance
value
Instance may contain up to 16 characters.
configitem Password
value
Password may contain up to 32 characters.
The value is HIDDEN.
configgroup WLAN Profile
These settings pertain to a WLAN Profile on the device.
In the Security section, choice of Suite, Key Type and Authentication affect the makeup of other
configurables in that section.
In the Advanced section, if Power Management is enabled, specify the Power Management Interval.
Use the Apply button to try out settings on the WLAN without saving them to Flash. If the settings do not
work, when you reboot the device, it will still have the original settings.
Use the Submit button to both update the WLAN settings and save them to Flash.
If the device is connecting to an acess point on a different wireless channel, current connection to the soft
AP interface of the device may be dropped due to the switch of channel. Reconnect to the soft AP interface
in order to continue access to the device.
configitem Instance
value
Instance may contain up to 35 characters.
configitem Basic
value Network Name
Network Name may contain up to 32 characters.
value State
State may be "Enabled" or "Disabled".
configitem Security
value Suite
Suite may be "None", "WEP", "WPA" or "WPA2".
value WEP Key Size
Key Size may be "40" or "104".
value WEP TX Key Index
TX Key Index may be "1", "2", "3" or "4".
value WEP Key Key
Key may contain up to 13 bytes.
xPico® Wi-Fi® Embedded Device Server User Guide
85
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
The value is HIDDEN.
value WPAx Key Type
Key Type may be "Passphrase" or "Hex".
value WPAx Passphrase
Passphrase may contain up to 63 characters.
The value is HIDDEN.
value WPAx Key
Key may contain up to 32 bytes.
The value is HIDDEN.
value WPAx Encryption
Encryption may contain any combination of "CCMP" or "TKIP".
configitem Advanced
value TX Power Maximum
TX Power Maximum has units of dBm.
value Power Management
Power Management may be "Enabled" or "Disabled".
value Power Management Interval
Power Management Interval has units of beacons (100 ms each).
configgroup XML Import Control
No help available.
configitem Restore Factory Configuration
value
Restore Factory Configuration may be "Enabled" or "Disabled".
configitem Reboot
value
Reboot may be "Enabled" or "Disabled".
configitem Missing Values
value
Missing Values may be "Unchanged" or "Set to Default".
configitem Delete WLAN Profiles
value
Delete WLAN Profiles may be "Enabled" or "Disabled".
xPico® Wi-Fi® Embedded Device Server User Guide
86
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem WLAN Profile delete
value name
name may contain up to 35 characters.
configgroup Modem Emulation
Connections can be initiated and accepted using Modem "AT" commands incoming from the Serial Line.
configitem Listen Port
value
Specify a Listen Port to accept connections on.
Blank the value for "<None>".
configitem Echo Pluses
value
With Echo Pluses enabled, pluses will be echoed back during a "pause +++ pause" escape sequence on the
Serial Line.
Echo Pluses may be "Enabled" or "Disabled".
configitem Echo Commands
value
With Echo Commands enabled (ATE1), characters read on the Serial Line will be echoed while the Line
is in Modem Command Mode.
Echo Commands may be "Enabled" or "Disabled".
configitem Verbose Response
value
With Verbose Reponse enabled (ATQ0), Modem Response Codes are sent out on the Serial Line.
Verbose Response may be "Enabled" or "Disabled".
configitem Response Type
value
Response Type selects either Text (ATV1) or Numeric (ATV0) representation for the Modem Response
Codes sent out on the Serial Line.
Response Type may be "Text" or "Numeric".
configitem Error Unknown Commands
value
With Error Unknown Commands enabled (ATU0), ERROR is returned on the Serial Line for
unrecognized AT commands. Otherwise (ATU1) OK is returned for unrecognized AT commands.
Error Unknown Commands may be "Enabled" or "Disabled".
xPico® Wi-Fi® Embedded Device Server User Guide
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Incoming Connection
value
Incoming Connection requests may be disabled (ATS0=0), answered automatically (ATS0=1), or
answered manually via the ATA command after an incoming RING (ATS0=2 or higher).
Incoming Connection may be "Disabled", "Automatic" or "Manual".
configitem Connect String
value
The Connect String is a customized string that is sent to the Serial Line with the CONNECT Modem
Response Code.
Connect String may contain up to 30 characters.
configitem Display Remote IP
value
With Display Remote IP enabled, the incoming RING sent on the Serial Line is followed by the IP
address of the caller.
Display Remote IP may be "Enabled" or "Disabled".
configgroup Monitor Initialization
These settings pertain to Monitor Initialization in the device.
Monitor will process any initialization message before it starts polling or process any control message.
Response captured during initialization will be overwritten by any poll or control response.
configitem Initial Delay
value
Sets Initial Delay waited before monitor start processing any initialization message.
Initial Delay has units of milliseconds.
configitem Message
value Command
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Command may contain up to 16 bytes.
value End Character
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
The End Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
xPico® Wi-Fi® Embedded Device Server User Guide
88
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
\10 (decimal)
End Character may contain one character, where <control>J, for example, counts as one.
value Length
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
Length has units of bytes.
value Timeout
Sets the Timeout to receive response. Minimum timeout is 100 milliseconds.
Response is ended by any configured End Character, Length OR Timeout.
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
configgroup Monitor Control
These settings pertain to Monitor Control in the device.
Control Message will be processed after receiving status action Send. Response will overwrite any
response captured during initialization or poll. Response must be read before sending another status action
Send or buffer will be reset.
configitem Message
value Command
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Command may contain up to 16 bytes.
value End Character
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
The End Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
End Character may contain one character, where <control>J, for example, counts as one.
value Length
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
Length has units of bytes.
xPico® Wi-Fi® Embedded Device Server User Guide
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
value Timeout
Sets the Timeout to receive response. Minimum timeout is 100 milliseconds.
Response is ended by any configured End Character, Length OR Timeout.
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
configgroup Monitor Poll
These settings pertain to Monitor Poll in the device.
Poll Message will be processed periodically. Response will overwrite any response captured during
initialization or poll.
configitem Message
value Command
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Command may contain up to 16 bytes.
value End Character
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
The End Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
End Character may contain one character, where <control>J, for example, counts as one.
value Length
Sets the Length of response.
Response is ended by any configured End Character, Length OR Timeout.
Length has units of bytes.
value Timeout
Sets the Timeout to receive response. Minimum timeout is 100 milliseconds.
Response is ended by any configured End Character, Length OR Timeout.
Timeout has units of milliseconds.
Blank the value for "<Minimum>".
configitem Delay
value
Sets Delay waited before monitor starts processing all poll messages again. 0 means poll messages are sent
xPico® Wi-Fi® Embedded Device Server User Guide
90
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
only once.
Delay has units of seconds.
configgroup Monitor Filter
These settings pertain to Monitor Filter in the device.
Filter settings will be applied to all received response. Filter results can be used to feed another filter or use
as Data Reference.
configitem Rule
value Source
Sets the Source in dot number format.
Source defines the input of a filter. E.g. If the source of this Filter is the second trunk of data created by
filter 1, Source must be set to "1.2". A Source of "0" indicates the raw response.
Dot number format could be "0" or two numbers separated by a dot (e.g. "1.2").
Source may contain up to 6 characters.
value Mode
Sets filter Mode.
All makes filter ouput to be a duplicate of input.
Delimiters filter breaks input up to 8 trunks separated by Binary String. Each trunk will not contain the
delimiters.
Binary filter breaks input into 3 trunks according to Offset and Length.
Mode may be "All", "Delimiters" or "Binary".
value Delimiter Binary String
Sets Binary String delimiter in binary format.
Delimiters break input up to 8 trunks separated by (but not containing) delimiters. A delimiter is
recognized if any of the Binary String is completely matched.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Binary String may contain up to 6 bytes.
value Start Index
Sets Start Index to indicate when Delimiters filter starts breaking input into trunks.
value Offset
Sets Offset for the size of the first trunk of data created by Binary Filter.
Offset has units of bytes.
value Length
Sets Length for the size of the second trunk of data created by Binary Filter. The third trunk of data
created by Binary Filter will contain the rest of input.
Length has units of bytes.
xPico® Wi-Fi® Embedded Device Server User Guide
91
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configgroup Monitor Data
These settings pertain to Monitor Data in the device.
Data configured here will be accessible through the status of Monitor.
configitem Selector
value Name
Sets Name to enable the data selector.
Name may contain up to 16 characters.
value Response
Sets Response instance to select the source of data. Response instance corresponds to Poll or Control
Message instance.
Blank the value for "<None>".
value Reference
Sets the Reference in dot number format.
Reference selects the output of Monitor Filter. E.g. If data should select the second trunk of data created
by filter 1, Reference must be set to "1.2". A Reference of "0" indicates the raw response.
Dot number format could be "0" or two numbers separated by a dot (e.g. "1.2").
Reference may contain up to 6 characters.
configgroup Tunnel Accept
Tunnel Accept Mode controls how a tunnel behaves when a connection attempt originates from the
network.
configitem Mode
value
An Accept Tunnel can be started in a number of ways, according to its Mode:
Disabled: never started.
Always: always started.
Any Character: started when any character is read on the Serial Line.
Start Character: started when the Start Character is read on the Serial Line.
Modem Control Asserted: started when the Modem Control pin is asserted on the Serial Line.
Mode may be "Disable", "Always", "Any Character", "Start Character" or "Modem Control Asserted".
configitem Local Port
value
The Local Port value can be overridden. By default, it is 10001 for Tunnel 1, 10002 for Tunnel 2, and so
on.
Blank the display field to restore the default.
xPico® Wi-Fi® Embedded Device Server User Guide
92
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Protocol
value
The Protocol used on the connection can be TCP.
Protocol may be "TCP".
configitem Start Character
value
When the Start Character is received on the Serial Line, it enables the tunnel to listen for a network
connection.
The Start Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
Start Character may contain one character, where <control>J, for example, counts as one.
configitem Flush Start Character
value
Enabling Flush Start Character prevents forwarding of a start character from the Line into the network.
Disabling Flush Start Character allows forwarding of a start character from the Line into the network.
Flush Start Character may be "Enabled" or "Disabled".
configitem Flush Line
value
Flush Line applies at the time when a connection is accepted from the network.
If Enabled, any buffered characters from the Serial Line will be discarded when a connection is accepted.
If Disabled, any characters received on the Serial Line will be buffered and sent after a connection is
accepted.
Flush Line may be "Enabled" or "Disabled".
configitem Block Line
value
Block Line may be enabled for debugging purposes.
If Enabled, incoming characters from the Serial Line will NOT be forwarded to the network. Instead, they
will be buffered and will eventually flow off the Serial Line if hardware or software flow control is
configured.
If Disabled (the normal setting), incoming characters from the Serial Line are sent on into the network.
Any buffered characters are sent first.
Block Line may be "Enabled" or "Disabled".
xPico® Wi-Fi® Embedded Device Server User Guide
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Block Network
value
Block Network may be enabled for debugging purposes.
If Enabled, incoming characters from the network will NOT be forwarded to the Serial Line. Instead, they
will be buffered and will eventually flow off the network side.
If Disabled (the normal setting), incoming characters from the network are sent on into the Serial Line.
Any buffered characters are sent first.
Block Network may be "Enabled" or "Disabled".
configitem Password
value
The Password can be up to 31 characters in length and must contain only alphanumeric characters and
punctuation. When set, clients must send the correct password string to the unit within 30 seconds from
opening network connection in order to enable data transmission. The password sent to the unit must be
terminated with one of the following:
0A (Line Feed)
00 (Null)
0D 0A (Carriage Return / Line Feed)
0D 00 (Carriage Return / Null)
If Prompt for Password is set to Enabled, the user will be prompted for the password upon connection.
Password may contain up to 31 characters.
The value is HIDDEN.
configitem Prompt for Password
value
Prompt for Password may be "Enabled" or "Disabled".
configgroup Tunnel Line
The Line Configuration applies to the Serial Line interface.
See also the Line configuration.
configitem DTR
value
The DTR options select the conditions in which the Data Terminal Ready control signal on the Serial
Line is asserted.
The DTR option Asserted while connected causes DTR to be asserted whenever either a connect or an
accept mode tunnel connection is active.
DTR may be "Asserted while connected", "Continuously asserted" or "Unasserted".
xPico® Wi-Fi® Embedded Device Server User Guide
94
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configgroup Tunnel Connect
Tunnel Connect controls how a tunnel behaves when a connection attempt originates locally.
configitem Mode
value
A Connect Tunnel can be started in a number of ways, according to its Mode:
Disabled: never started.
Always: always started.
Any Character: started when any character is read on the Serial Line.
Start Character: started when the Start Character is read on the Serial Line.
Modem Control Asserted: started when the Modem Control pin is asserted on the Serial Line.
Mode may be "Disable", "Always", "Any Character", "Start Character" or "Modem Control Asserted".
configitem Start Character
value
When the Start Character is received on the Serial Line, it connects the tunnel.
The Start Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
Start Character may contain one character, where <control>J, for example, counts as one.
configitem Flush Start Character
value
Enabling Flush Start Character prevents forwarding of a start character from the Line into the network.
Disabling Flush Start Character allows forwarding of a start character from the Line into the network.
Flush Start Character may be "Enabled" or "Disabled".
configitem Local Port
value
The Local Port is by default random but can be overridden.
Blank the field to restore the random default.
Blank the value for "<Random>".
configitem Host
value Address
The Host Address is required to enable a Connect Tunnel.
It designates the address of the remote host to connect to.
Either a DNS address or an IP address may be provided.
Address may contain up to 50 characters.
xPico® Wi-Fi® Embedded Device Server User Guide
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
value Port
The Host Port is required to enable a Connect Tunnel.
It designates the TCP port on the remote host to connect to.
Blank the value for "<None>".
value Protocol
The Protocol used on the connection can be TCP.
Protocol may be "TCP".
configitem Connections
value
Connections controls how multiple hosts shall be used with a Connect Tunnel.
With Sequential selected, when it is time for the tunnel to connect, it will start with host 1 and attempt
each host in sequence until a connection is accepted.
With Simultaneous selected, when it is time for the tunnel to connect, it will connect to all of the hosts that
accept a connection.
Connections may be "Sequential" or "Simultaneous".
configitem Reconnect Time
value
The Reconnect Time specifies how long to wait in seconds before trying to reconnect to the remote host
after a previous attempt failed or the connection was closed.
Blank the display field to restore the default.
Reconnect Time has units of seconds.
configitem Flush Line
value
Flush Line applies at the time when a connection is established to the network.
If Enabled, any buffered characters from the Serial Line will be discarded when a connection is
established.
If Disabled, any characters received on the Serial Line will be buffered and sent after a connection is
established.
Flush Line may be "Enabled" or "Disabled".
configitem Block Line
value
Block Line may be enabled for debugging purposes.
If Enabled, incoming characters from the Serial Line will NOT be forwarded to the network. Instead, they
will be buffered and will eventually flow off the Serial Line if hardware or software flow control is
configured.
If Disabled (the normal setting), incoming characters from the Serial Line are sent on into the network.
Any buffered characters are sent first.
Block Line may be "Enabled" or "Disabled".
xPico® Wi-Fi® Embedded Device Server User Guide
96
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Block Network
value
Block Network may be enabled for debugging purposes.
If Enabled, incoming characters from the network will NOT be forwarded to the Serial Line. Instead, they
will be buffered and will eventually flow off the network side.
If Disabled (the normal setting), incoming characters from the network are sent on into the Serial Line.
Any buffered characters are sent first.
Block Network may be "Enabled" or "Disabled".
configgroup Tunnel Disconnect
These settings relate to Disconnecting a Tunnel.
configitem Stop Character
value
When the Stop Character is received on the Serial Line, it disconnects the tunnel.
The Stop Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
Disable the Stop Character by blanking the field to set it to <None>.
Stop Character may contain one character, where <control>J, for example, counts as one.
configitem Flush Stop Character
value
Enabling Flush Stop Character prevents forwarding of a stop character from the Line into the network.
Disabling Flush Stop Character allows forwarding of a stop character from the Line into the network.
Flush Stop Character may be "Enabled" or "Disabled".
configitem Modem Control
value
Modem Control enables disconnect when the Modem Control pin is not asserted on the Serial Line.
Modem Control may be "Enabled" or "Disabled".
configitem Timeout
value
Timeout enables disconnect after the tunnel is idle for a specified number of milliseconds. The value of
zero disables the idle timeout.
Timeout has units of milliseconds.
Blank the value for "<Disabled>".
xPico® Wi-Fi® Embedded Device Server User Guide
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Flush Line
value
Flush Line enabled will flush the Serial Line when the Tunnel is disconnected.
Flush Line may be "Enabled" or "Disabled".
configgroup Tunnel Packing
When Tunneling, instead of sending data on the network immediately after being read on the Serial Line,
the data can be Packed (queued) and sent in larger chunks.
configitem Mode
value
A Tunnel can be configured to use Packing Mode in the following ways:
Disable: data not packed.
Timeout: data sent after timeout occurs.
Send Character: data sent when the Send Character is read on the Serial Line.
Mode may be "Disable", "Timeout" or "Send Character".
configitem Timeout
value
If the oldest byte of queued data has been waiting for Timeout milliseconds, the queued data will be sent
on the network immediately.
Timeout has units of milliseconds.
configitem Threshold
value
If the number of bytes of queued data reaches the Threshold, the queued data will be sent on the network
immediately.
Threshold has units of bytes.
configitem Send Character
value
If used, the Send Character is a single printable character or a control character that, when read on the
Serial Line, forces the queued data to be sent on the network immediately.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
Send Character may contain one character, where <control>J, for example, counts as one.
xPico® Wi-Fi® Embedded Device Server User Guide
98
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Command Reference
configitem Trailing Character
value
The Trailing Character is an optional single printable character or control character that is injected into
the outgoing data stream right after the Send Character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)
\10 (decimal)
Disable the Trailing Character by blanking the field to set it to <None>.
Trailing Character may contain one character, where <control>J, for example, counts as
one.
xPico® Wi-Fi® Embedded Device Server User Guide
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: WebAPI
WebAPI is a cloud function API allowing access to configuration and status information of xPico
Wi-Fi embedded device server through standard HTTP request.
Export Status Group
An HTTP POST request can be sent to the device to retrieve status information.
Protocol: HTTP
Method: Post
URL: http://<hostname>/export/status
Parameters:
optionalLine: Optional line index for line oriented XML groups
optionalGroupList: Optional list of XML groups separated by semicolon. If omitted, all status
groups will be returned.
CURL example:
curl -u admin:PASSWORD http://172.19.100.125/export/status -X POST
curl -u admin:PASSWORD http://172.19.100.125/export/status -X POST -d
"optionalGroupList=Device"
Javascript example:
myXmlhttprequest.open(
"POST",
"/export/status",
true
);
request.send(
"optionalGroupList=Device"
);
Export Configuration Group
An HTTP POST request can be sent to the device to retrieve configuration information.
Protocol: HTTP
Method: Post
URL: http://<hostname>/export/config
Parameters:
optionalLine: Optional line index for line oriented XML groups
optionalGroupList: Optional list of XML groups separated by semicolon. If omitted, all
configuration groups will be returned.
xPico® Wi-Fi® Embedded Device Server User Guide
100
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: WebAPI
optionalBoolNeedSecret: To retrieve the original value for hidden configuration, set this to "true".
CURL example:
curl -u admin:PASSWORD http://172.19.100.125/export/config -X POST
curl -u admin:PASSWORD http://172.19.100.125/export/config -X POST -d
"optionalGroupList=Interface:wlan0"
Javascript example:
myXmlhttprequest.open(
"POST",
"/export/config",
true
);
request.send(
"optionalGroupList= Interface:wlan0"
);
Take Status Action
An HTTP POST request can be sent to the device to take a status action.
Protocol: HTTP
Method: Post
URL: http://<hostname>/action/status
Parameters:
group: Required. The status group where action is defined.
optionalGroupInstance: Optional instance of status group.
optionalItem: Optional item of status group where action is defined.
optionalItemInstance: Optional instance of status item.
action: Required. The action to be taken.
CURL example:
curl -u admin:PASSWORD http://172.19.100.125/action/status -X POST -d
"group=Interface&optionalGroupInstance=wlan0&action=Renew"
Javascript example:
myXmlhttprequest.open(
"POST",
"/action/status",
true
);
request.send(
" group=Interface&optionalGroupInstance=wlan0&action=Renew "
);
xPico® Wi-Fi® Embedded Device Server User Guide
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: WebAPI
Import Configuration Group
An HTTP POST request can be sent to the device to set configuration.
Protocol: HTTP
Method: Post
Content-Type: multipart/form-data
URL: http://<hostname>/import/config
Parameters:
configrecord: Content of configuration group in XML format.
CURL example (configuration is saved in a local file config.xml):
curl -u admin:PASSWORD http://172.19.100.125/import/config -X POST --
form [email protected]
CURL example (configuration as part of command):
curl -u admin:PASSWORD http://172.19.100.125/import/config -X POST --
form-string 'configrecord=<?xml version="1.0" standalone="yes"?>
<!-- Automatically generated XML -->
<!DOCTYPE configrecord [
<!ELEMENT configrecord (configgroup+)>
<!ELEMENT configgroup (configitem+)>
<!ELEMENT configitem (value+)>
<!ELEMENT value (#PCDATA)>
<!ATTLIST configrecord version CDATA #IMPLIED>
<!ATTLIST configgroup name CDATA #IMPLIED>
<!ATTLIST configgroup instance CDATA #IMPLIED>
<!ATTLIST configitem name CDATA #IMPLIED>
<!ATTLIST configitem instance CDATA #IMPLIED>
<!ATTLIST value name CDATA #IMPLIED>
]>
<configrecord version = "0.1.0.1">
<configgroup name = "Access Point" instance = "ap0">
<configitem name = "SSID">
<value>MY DEVICE</value>
</configitem>
</configgroup>
</configrecord>'
HTTP example:
<form method="post" enctype="multipart/form-data" action="/import/
config" target="_blank">
<input name="configrecord" type="file" size="32">
<input name="submit" type="submit" value="Import Configuration">
</form>
xPico® Wi-Fi® Embedded Device Server User Guide
102
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Technical Support
If you are unable to resolve an issue using the information in this documentation, please contact
Technical Support.
North America
Hours: 6:00am - 5:00pm Pacific Time
www.lantronix.com/support/
Tel: (800) 422-7044 (US Only)
Tel: (949) 453-7198
Fax: (949) 450-7226
www.lantronix.com/support/
Tel: +31 (0)76 52 36 740
Japan
Tel: +81-3-6277-8802
Asia / Pacific (APAC)
Tel: + 852 3428-2338
China
Tel: + 86-21-6237-8868
Tel: 400-820-0502
xPico® Wi-Fi® Embedded Device Server User Guide
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: Technical Support
Tel: +1 949 453 3990
Online
Support options listed below are available 24 hours a day, 7 days a week at the Lantronix support
page at http://www.lantronix.com/support
Download firmware
Search and review Frequently asked Questions (FAQs)
Send a question to technical support
When you report a problem, please provide the following information:
Your name, and your company name, address, and phone number
Lantronix model number
Lantronix serial number/MAC address
Firmware version (on the Web Manager Status page or via CLI at the Status->Device level)
Description of the problem
Status of the unit when the problem occurred (please try to include information on user and
network activity at the time of the problem)
Additionally, it may be useful to export and submit the exported XML Configuration file.
xPico® Wi-Fi® Embedded Device Server User Guide
104
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
(According to ISO/IEC Guide and EN 45014)
Manufacturer's Name & Address:
Lantronix, Inc.
167 Technology Drive, Irvine, CA 92618 USA
Declares that the following product:
Product Name Model: xPico® Wi-Fi® Embedded Device Server
Conforms to the following standards or other normative documents:
Table D-1 Country Certifications
Country
Specification
FCC Part 15, Subpart B, Class B
ICES-003:2012 Issue 5, Class B
ANSI C63.4-2009
USA
USA
FCC Part 15, Subpart C (Section 15.247)
ANSI C63.10-2009
FCC Part 2 (Section 2.1091)
FCC OET Bulletin 65, Supplement C (01-01)
IEEE C95.1
Canada
EU
Canada RSS-210 Issue 8 (2010-12)
Canada RSS-Gen Issue 3 (2010-12)
ANSI C63.10-2009
RSS-102 Issue 4 (2010-12)
EN 300 328 V1.8.1 (2012-06)
EN 301 489-1 V1.9.2 (2011-09)
EN 301 489-17 V2.2.1 (2012-09)
EN 55022:2010+AC:2011, Class B
EN62311:2008
AS/NZS 4268: 2012
Australia, New Zealand
Japan
N11206
ARIB STD-T66, MIC notice 88 Appendix 43
RCR STD-33, MIC notice 88 Appendix 44
Table D-2 Country Transmitter IDs
Country
Specification
R68XPICOW
3867A-XPICOW
201-135275
USA FCC ID
Canada IC ID
Japan ID
xPico® Wi-Fi® Embedded Device Server User Guide
105
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
Table D-3 Safety
Country
Specification
CB
World Wide
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
In accordance with the council directive 2006/95/EC
US, Canada
UL 60950-1 (2nd Edition)
Hereby, Lantronix, declares that this xPico Wi-Fi is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.
Table D-4 Europe – EU Declaration of Conformity
Lantronix, Inc. tímto prohlašuje, že tento xPico Wi-Fi je ve shodě se základními
požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
cs
da
de
Česky [Czech]
Undertegnede Lantronix, Inc. erklærer herved, at følgende udstyr xPico Wi-Fi
overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Dansk [Danish]
Hiermit erklärt Lantronix, Inc., dass sich das Gerät xPico Wi-Fi in Übereinstimmung mit
den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der
Richtlinie 1999/5/EG befindet.
Deutsch [German]
Käesolevaga Lantronix, Inc. seadme xPico Wi-Fi vastavust direktiivi 1999/5/EÜ
põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
et
en
es
Eesti [Estonian]
English
Hereby, Lantronix, Inc., declares that this xPico Wi-Fi is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Por medio de la presente Lantronix, Inc. declara que el xPico Wi-Fi cumple con los
requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la
Directiva 1999/5/CE.
Español [Spanish]
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Lantronix, Inc. ΔΗΛΩΝΕΙ ΟΤΙ xPico Wi-Fi ΣΥΜΜΟΡΦΩΝΕΤΑΙ
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ
ΟΔΗΓΙΑΣ 1999/5/ΕΚ.
el
Ελληνική [Greek]
Par la présente Lantronix, Inc. déclare que l'appareil xPico Wi-Fi est conforme aux
exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
fr
it
Français [French]
Con la presente Lantronix, Inc. dichiara che questo xPico Wi-Fi è conforme ai requisiti
essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Italiano [Italian]
Latviski [Latvian]
Ar šo Lantronix, Inc. deklarē, ka xPico Wi-Fi atbilst Direktīvas 1999/5/EK būtiskajām
prasībām un citiem ar to saistītajiem noteikumiem.
Lietuvių [Lithuanian]
Šiuo Lantronix, Inc. deklaruoja, kad šis xPico Wi-Fi atitinka esminius reikalavimus ir
kitas 1999/5/EB Direktyvos nuostatas.
Hierbij verklaart Lantronix, Inc. dat het toestel xPico Wi-Fi in overeenstemming is met de
essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
nl
Nederlands [Dutch]
Malti [Maltese]
Magyar [Hungarian]
Polski [Polish]
Hawnhekk, Lantronix, Inc.], jiddikjara li dan xPico Wi-Fi jikkonforma mal-ħtiġijiet
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
mt
hu
pl
Alulírott, Lantronix, Inc. nyilatkozom, hogy a xPico Wi-Fi megfelel a vonatkozó alapvetõ
követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Niniejszym Lantronix, Inc. oświadcza, że xPico Wi-Fi jest zgodny z zasadniczymi
wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Lantronix, Inc. declara que este xPico Wi-Fi está conforme com os requisitos essenciais
e outras disposições da Directiva 1999/5/CE.
pt
Português
[Portuguese]
xPico® Wi-Fi® Embedded Device Server User Guide
106
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
Table D-4 Europe – EU Declaration of Conformity (continued)
Lantronix, Inc. izjavlja, da je ta xPico Wi-Fi v skladu z bistvenimi zahtevami in ostalimi
relevantnimi določili direktive 1999/5/ES.
sl
Slovensko [Slovenian]
Slovensky [Slovak]
Lantronix, Inc. týmto vyhlasuje, že xPico Wi-Fi spĺňa základné požiadavky a všetky
príslušné ustanovenia Smernice 1999/5/ES.
Lantronix, Inc. vakuuttaa täten että xPico Wi-Fi tyyppinen laite on direktiivin 1999/5/EY
oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
fi
Suomi [Finnish]
Härmed intygar Lantronix, Inc. att denna xPico Wi-Fi står I överensstämmelse med de
väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv
1999/5/EG.
sv
Svenska [Swedish]
Federal Communication Commission Interference Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This device is intended only for OEM integrators under the following conditions:
1. The antenna must be installed such that 20 cm is maintained between the antenna and users,
and
2. The transmitter module may not be co-located with any other transmitter or antenna.
As long as 2 conditions above are met, further transmitter test will not be required. However, the
OEM integrator is still responsible for testing their end-product for any additional compliance
requirements required with this module installed
xPico® Wi-Fi® Embedded Device Server User Guide
107
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
IMPORTANT NOTE: In the event that these conditions can not be met (for example
certain laptop configurations or co-location with another transmitter), then the FCC
authorization is no longer considered valid and the FCC ID can not be used on the final
product. In these circumstances, the OEM integrator will be responsible for re-evaluating
the end product (including the transmitter) and obtaining a separate FCC authorization.
End Product Labeling
This transmitter module is authorized only for use in device where the antenna may be installed
such that 20 cm may be maintained between the antenna and users. The final end product must
be labeled in a visible area with the following: “Contains FCC ID: R68XPICOW”. The grantee's
FCC ID can be used only when all FCC compliance requirements are met.
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to
install or remove this RF module in the user’s manual of the end product which integrates this
module.
The end user manual shall include all required regulatory information/warning as show in this
manual.
Industry Canada Statement
This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio
exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif
ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage
reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.
Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Déclaration d'exposition aux radiations
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20
cm de distance entre la source de rayonnement et votre corps.
This device is intended only for OEM integrators under the following conditions: (For
module device use)
1. The antenna must be installed such that 20 cm is maintained between the antenna and users,
and
2. The transmitter module may not be co-located with any other transmitter or antenna.
xPico® Wi-Fi® Embedded Device Server User Guide
108
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
As long as 2 conditions above are met, further transmitter test will not be required. However, the
OEM integrator is still responsible for testing their end-product for any additional compliance
requirements required with this module installed.
Cet appareil est conçu uniquement pour les intégrateurs OEM dans les conditions
suivantes: (Pour utilisation de dispositif module)
L'antenne doit être installée de telle sorte qu'une distance de 20 cm est respectée entre l'antenne
et les utilisateurs, et
Le module émetteur peut ne pas être coïmplanté avec un autre émetteur ou antenne.
Tant que les 2 conditions ci-dessus sont remplies, des essais supplémentaires sur l'émetteur ne
seront pas nécessaires. Toutefois, l'intégrateur OEM est toujours responsable des essais sur son
produit final pour toutes exigences de conformité supplémentaires requis pour ce module installé.
IMPORTANT NOTE: In the event that these conditions can not be met (for example
certain laptop configurations or co-location with another transmitter), then the Canada
authorization is no longer considered valid and the IC ID can not be used on the final
product. In these circumstances, the OEM integrator will be responsible for re-evaluating
the end product (including the transmitter) and obtaining a separate Canada authorization.
NOTE IMPORTANTE: Dans le cas où ces conditions ne peuvent être satisfaites (par
exemple pour certaines configurations d'ordinateur portable ou de certaines co-
localisation avec un autre émetteur), l'autorisation du Canada n'est plus considéré comme
valide et l'ID IC ne peut pas être utilisé sur le produit final. Dans ces circonstances,
l'intégrateur OEM sera chargé de réévaluer le produit final (y compris l'émetteur) et
l'obtention d'une autorisation distincte au Canada.
End Product Labeling
This transmitter module is authorized only for use in device where the antenna may be installed
such that 20 cm may be maintained between the antenna and users. The final end product must
be labeled in a visible area with the following:
“Contains IC: 3867A-XPICOW".
Plaque signalétique du produit final
Ce module émetteur est autorisé uniquement pour une utilisation dans un dispositif où l'antenne
peut être installée de telle sorte qu'une distance de 20cm peut être maintenue entre l'antenne et
les utilisateurs. Le produit final doit être étiqueté dans un endroit visible avec l'inscription suivante:
"Contient des IC: 3867A-XPICOW".
Manual Information To the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to
install or remove this RF module in the user’s manual of the end product which integrates this
module.
The end user manual shall include all required regulatory information/warning as show in this
manual.
xPico® Wi-Fi® Embedded Device Server User Guide
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
Manuel d'information à l'utilisateur final
L'intégrateur OEM doit être conscient de ne pas fournir des informations à l'utilisateur final quant à
la façon d'installer ou de supprimer ce module RF dans le manuel de l'utilisateur du produit final
qui intègre ce module.
Le manuel de l'utilisateur final doit inclure toutes les informations réglementaires requises et
avertissements comme indiqué dans ce manuel.
Antenna Requirement
This device has been designed to operate with a PIFA antenna have a maximum gain of 2.5dBi.
Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The
required antenna impedance is 50 ohms.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
This radio transmitter xPico Wi-Fi has been approved by Industry Canada to operate with the
antenna type, maximum permissible gain and required antenna impedance for each antenna type
indicated. Antenna types not included in this user's manual, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use with this device.
Ce dispositif a été conçu pour fonctionner avec une antenne ayant un gain maximal de PIFA
antenne avec dBi 2.5. Une antenne à gain plus élevé est strictement interdite par les règlements
d'Industrie Canada. L'impédance d'antenne requise est de 50 ohms.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peutfonctionner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pourl'émetteur par
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectriqueà l'intention des
autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que lapuissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire àl'établissement d'une
communication satisfaisante.
Le présent émetteur radio xPico Wi-Fi a été approuvé par Industrie Canada pour fonctionner avec
les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance
requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le
gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur.
Table D-5 Approved Antenna(s) List
Type
PIFA
Gain
2.5dBi
2.38
Brand
ethertronics
Wanshih
Dipole
xPico® Wi-Fi® Embedded Device Server User Guide
110
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D: Compliance
Manufacturer's Contact:
Lantronix, Inc.
167 Technology Drive, Irvine, CA 92618 USA
Tel: 949-453-3990
Fax: 949-453-3995
RoHS Notice
All Lantronix products in the following families are China RoHS-compliant and free of the following hazardous
substances and elements:
Lead (Pb)
Mercury (Hg)
Polybrominated biphenyls (PBB)
Cadmium (Cd)
Hexavalent Chromium (Cr (VI))
Polybrominated diphenyl ethers (PBDE)
Product Family Name
Toxic or hazardous Substances and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium (Cr
Polybrominate
d biphenyls
Polybrominated
diphenyl ethers (PBDE)
(VI))
0
(PBB)
0
DSC
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
EDS
0
0
IntelliBox
MatchPort
Micro
0
0
0
0
0
0
MSS100
PremierWave
SCS
0
0
0
0
0
0
SecureBox
SLB
0
0
0
0
SLC
0
0
SLP
0
0
Spider and Spider Duo
UBox
0
0
0
0
UDS1100 and 2100
WiBox
0
0
0
0
WiPort
0
0
xDirect
0
0
xPico
0
0
xPico Wi-Fi
XPort
0
0
0
0
XPort Pro
XPress DR & XPress-DR+
xPrintServer
xSenso
0
0
0
0
0
0
0
0
O: toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement in SJ/T11363-2006.
X: toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the
limit requirement in SJ/T11363-2006.
xPico® Wi-Fi® Embedded Device Server User Guide
111
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix E: Binary to Hexadecimal Conversions
Many unit configuration procedures require you to assemble a series of options (represented as
bits) into a complete command (represented as a byte).
The resulting binary value must be converted to a hexadecimal representation.
Use this chapter to learn to convert binary values to hexadecimals or to look up hexadecimal
values in the tables of configuration options. The tables include:
Command Mode (serial string sign-on message)
AES Keys
Converting Binary to Hexadecimal
Table E-1 Binary to Hexadecimal
Conversion
Following are two simple ways to convert binary
numbers to hexadecimal notation.
Decimal
Binary
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Hex
0
Conversion Table
0
Hexadecimal digits have values ranging from 0 to F,
which are represented as 0-9, A (for 10), B (for 11),
etc. To convert a binary value (for example, 0100
1100) to a hexadecimal representation, treat the
upper and lower four bits separately to produce a two-
digit hexadecimal number (in this case, 4C). Use the
following table to convert values from binary to
hexadecimal.
1
1
2
2
3
3
4
4
5
5
Scientific Calculator
6
6
Another simple way to convert binary to hexadecimal
is to use a scientific calculator, such as the one
available on the Windows operating systems. For
example:
7
7
8
8
9
9
1. On the Windows Start menu, click All Programs -
> Accessories -> Calculator.
10
11
12
13
14
15
A
B
C
D
E
F
2. On the View menu, select Scientific. The
scientific calculator appears.
3. Click Bin (Binary), and type the number you want
to convert.
xPico® Wi-Fi® Embedded Device Server User Guide
112
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix E: Binary to Hexadecimal Conversions
Figure E-2 Windows Scientific Calculator
4. Click Hex. The hexadecimal value appears.
Figure E-3 Hexadecimal Values in the Scientific Calculator
xPico® Wi-Fi® Embedded Device Server User Guide
113
Download from Www.Somanuals.com. All Manuals Search And Download.
|