MATERIAL SAFETY DATA SHEET  
Section 1: Chemical Product and Company Information  
Identity:  
Product ID:  
Black Toner for 5365  
480-0021  
MSDS No. CP- 332  
Issued: 05/22/2003  
Supersedes: 04/30/2001  
Synonyms  
& Common  
Names:  
Date: 05/22/03  
Black Toner for  
Lanier 5365, 5355, 5555, 5565, 5580,5480  
Prepared by: EH&S Department 770-496-9500  
Approved by: Larry Choskey, Manager, CEH&S  
European Contact: Walter Fricke, Manager, Safety & Environment,  
Lanier Worldwide, Inc.  
Uses:  
Lanier 5365, 5355, 5555, 5565, 5580, 5480  
Digital Copier  
Im Taubental D-41468 Neuss, Germany  
+49-2131-387-177  
Chemical  
Formula:  
Mixture  
Section 2: Composition / Information on Ingredients  
PERCENT  
CAS No.  
25036-16-2  
9010-79-1  
1333-86-4  
25869-00-5  
104815-18-1  
EXPOSURE LIMITS  
SOURCE  
Styrene acrylate copolymer  
> 90  
N/a  
N/a  
3
3
OSHA PEL ACGIH TWA  
N/a  
Carbon black  
Inorganic pigment  
Organic pigment  
5 - 7  
1 - 2  
1 – 2  
3.5mg/m 3.5mg/m  
N/a  
N/a  
N/a  
*PEL as the product: 15mg/m (total dust), 5mg/m3 (respirable dust)  
*TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)  
3
Section 3: Hazards Identification  
HMIS Rating:  
FLAMMABILITY = 1  
REACTIVITY = 0  
HEALTH = 0  
SPECIAL = none  
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-  
toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.  
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner  
revealed there were no lung changes at all in the lowest exposure level (1mg/m3), the most relevant level to potential human exposures. A very  
slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m3), while a slight degree of fibrosis was observed  
at the highest exposure level (16mg/m3) in all animals. These findings are attributed to “Lung Overloading”, a generic response to excessive  
amount of any dust retained in the lungs for a prolonged interval. The special test toner was ten times more respirable than commercially  
available toner to comply with EPA testing protocol and would not function properly in Xerographic equipment.  
Carbon Black is listed on the IARC Monograph and the Massachusetts Substance List. The IARC has evaluated the evidence for the  
carcinogenicity of Carbon Black as inadequate to determine a carcinogenic risk for humans.  
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200.  
Section 4: First Aid Measures  
Remove to fresh air if effects occur. Gargle with  
water. Get medical attention if needed.  
In case of contact, immediately flush eyes with  
water for 15 minutes. Get medical attention if  
needed.  
Dilute stomach contents with several glasses  
of water. Get medical attention if needed.  
Inhalation:  
Eye Contact:  
Ingestion:  
Skin Contact:  
Wash with soap and water.  
Section 5: Fire Fighting Measures  
Suitable extinguishing media: CO2, dry chemical, foam or water.  
Extinguishing media which may not be used for safety reasons: none  
Unusual Fire and Explosion Hazards: Toner material, like most  
organic material in powdered form, is capable of creating a  
dust explosion.  
Flammability: Product will burn in case of fire. The decomposition products are CO, CO2, and Nox. Avoid inhalation of smoke.  
Special protective equipment for fire fighters: none  
UEL: n/a  
LEL: n/a  
Section 6: Accidental Release Measures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MATERIAL SAFETY DATA SHEET  
Page 3  
of  
CP-332  
Judgment as to the suitability of information contained herein for user’s purposes is the responsibility of the purchaser. Therefore, although  
reasonable care has been taken in the preparation of this information, Lanier Worldwide, Inc. extends no warranties, makes no representations,  
and assumes no responsibility as to the accuracy or suitability of such information for application to user’s intended purposes or for  
consequences of its use. All materials may present unknown hazards and should be used with caution. Although certain hazards are  
described herein, we do not guarantee that these are the only hazards that exist.  
Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under normal conditions.  
On the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the usual precautionary measures  
for dealing with chemicals.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KTI Networks Switch 10BASE T 100BASE TX User Manual
LG Electronics Cell Phone 200C User Manual
Lightolier Indoor Furnishings VRA2G9LP317 User Manual
Lincoln Electric Welder eCell User Manual
Logitech Speaker System Z 5450 User Manual
Makita Power Screwdriver 6833 User Manual
Manitowoc Ice Ice Maker K00141 User Manual
M Audio Computer Monitor SESSION User Manual
Maytag Oven CWG3600AAB User Manual
McCulloch Trimmer 9238 989901 User Manual