Lanier Printer Accessories 117 0154 User Manual

Lanier Worldwide, Inc.  
2300 Parklake Drive, NE  
Atlanta, GA USA 30345-2979  
MATERIAL SAFETY DATA SHEET  
Emergency Telephone: 800-551-3087  
Section 1: Chemical Product and Company Information  
Identity:  
Product ID:  
MSDS No.  
Issued: 02/08/2005  
Toner for 6517/6717/6616/6720  
CP- 261  
117-0154  
Supersedes:  
06/10/1998  
02/08/2005  
EH&S Department 770-496-9500  
Synonyms  
& Common  
Names:  
Date:  
Prepared by:  
Black Toner for 6517, 6717, 6616,  
6720  
Approved by: Larry Choskey, Manager, CEH&S  
Uses:  
Lanier 6517, 6717, 6616, 6720  
Mixture  
Walter Fricke, Manager, Safety &  
Environment,  
European  
Contact:  
Chemical  
Formula:  
Lanier Worldwide, Inc.  
Im Taubental D-41468 Neuss,  
Germany +49-2131-387-177  
Section 2: Composition / Information on Ingredients  
Component  
Percent  
CAS No.  
Exposure Limits  
Source  
Styrene-acrylic resin  
Carbon black  
85 – 90  
5 – 10  
25153-46-2  
1333-86-4  
Not listed  
3.5 mg/m3  
3.5 mg/m3  
Not listed  
10 mg/m3  
10 mg/m3  
6 mg/m3  
N/a  
OSHA PEL  
ACGIH TWA  
N/a  
Wax  
Organic pigment  
1 – 6  
1 – 6  
9003-07-0  
116810-46-9  
OSHA PEL  
ACGIH TWA  
OSHA PEL  
ACGIH TWA  
Silica  
< 1  
7631-86-9  
10 mg/m3  
*PEL as the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust)  
*TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)  
Section 3: Hazards Identification  
HMIS Rating:  
FLAMMABILITY = 1  
REACTIVITY = 0  
HEALTH = 1  
SPECIAL = none  
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure  
to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.  
Health Hazards of Long Term exposure (Chronic): Prolonged inhalation of excessive dust may cause lung damage. It is  
attributed to “lung overloading”, a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval.  
Use of this product, as intended, does not result in inhalation of excessive dust.  
Carcinogenicity: Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation  
study in rats. However, there was not observed the incidence of tumors on the test results on dermal or oral studies. Also, 2-years  
inhalation study using a typical toner containing carbon black showed no association between toner exposure and animal tumors.  
Section 4: First Aid Measures  
Gargle with water. Remove to fresh air if effects  
In case of contact, immediately flush eyes  
with water for 15 minutes. Get medical  
attention if needed.  
Dilute stomach contents with several  
glasses of water. Get medical attention.  
occur. Get medical attention if needed.  
Inhalation:  
Eye Contact:  
Ingestion:  
Wash with soap and water.  
Skin Contact:  
Section 5: Fire Fighting Measures  
Suitable extinguishing media: CO2, dry chemical, foam or water.  
Extinguishing media which may not be used for safety  
reasons: none  
Special protective equipment for fire fighters: none  
UEL: n/a  
LEL: n/a  
your document management partner  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MATERIAL SAFETY DATA SHEET  
Page 3 of 3  
CP-261  
Section 15: Regulatory Information  
Section 16: Miscellaneous Information  
Regulation:  
not available  
Judgment as to the suitability of information contained herein for user’s purposes is the responsibility of the purchaser.  
Therefore, although reasonable care has been taken in the preparation of this information, Lanier Worldwide, Inc. extends no  
warranties, makes no representations, and assumes no responsibility as to the accuracy or suitability of such information for  
application to user’s intended purposes or for consequences of its use. All materials may present unknown hazards and  
should be used with caution. Although certain hazards are described herein, we do not guarantee that these are the only  
hazards that exist.  
Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under  
normal conditions. On the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the  
usual precautionary measures for dealing with chemicals.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Speaker WS 2814U IT User Manual
LG Electronics Washer Accessories 3828ER3020V User Manual
Life Fitness Home Gym SOWT User Manual
Maxim TV Converter Box MAX12557 User Manual
Maytag Range W10269526A User Manual
Maytag Washer W10560157C User Manual
McIntosh Stereo System M85 User Manual
Meade Binoculars DB1 User Manual
Melissa Toaster 743 196 User Manual
MicroNet Technology Switch SP616DB User Manual