INVENTORY OF CONTENTS
1. Wireless Weather Station
2. Thermo/hygro transmitter (TX29UD-TH-IT)
3. Instruction manual
Weather Station
Model WS-9057U
FEATURES:
The Weather Station
Instruction Manual
This product offers:
INSTANT TRANSMISSION is the state-of-
the-art new wireless transmission
technology, exclusively designed and
developed by LA CROSSE
Wall Mount
TECHNOLOGY. INSTANT
TRANSMISSION offers you an
LCD
Display
Battery
Compartment
immediate update (every 4 seconds!) of
all your outdoor data measured from the
transmitters: follow your climatic
variations in real-time!
Function Keys
Foldable
Stands
1
2
WWVB Radio controlled time with manual setting option
Time reception ON/OFF (user selectable)
12/24 hour time display
Time zone option ±12 hours
Daylight saving time (DST On/Off)
Weekday and day calendar display (year and month only in setting
mode)
Alarm setting with snooze function
Display 12 Moon phases throughout the year
Weather forecasting with weather tendency indicator
Indoor comfort indicator
LCD contrast selectable
Can receive up to 3 outdoor transmitters
Wireless transmission at 915 MHz
Signal reception intervals at 4 seconds
Low battery indicator
Table standing or wall mounting
Thermo-Hygro Transmitter
Remote transmission of outdoor
temperature and humidity to weather station
by 915 MHz signals
Temperature display in °F/°C
Indoor and outdoor temperature display with MIN/MAX records and
time of reception
Alternate display of temperature and
humidity display
Water-resistant casing
Wall mounting case. (Mount in a sheltered
place. Avoid direct rain and sunshine
Humidity data display as RH%
Indoor and outdoor humidity display with MIN/MAX records
Relative air pressure hPa/ inHg with adjustable reference value
Weather icon sensitivity setting
Relative air pressure history for the past 24 hours (electronic
barometer with barometric pressure trend)
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
When the weather station is receiving the WWVB time signal, the
outdoor transmitter data signal will temporarily not be received by
the weather station. During this short period of time, the outdoor
readings shown on the weather station will not be renewed until the
WWVB time signal is successfully received.
received and stored by the Weather Station in the first 3 minutes of power
being supplied to the transmitter.
TO INSTALL AND REPLACE BATTERIES IN THE WEATHER
STATION
The Weather Station uses 2 x C, IEC LR14, 1.5V batteries. To install and
replace the batteries, please follow the steps below:
TO INSTALL AND REPLACE BATTERIES IN THE THERMO-
HYGRO TRANSMITTER
The Thermo-Hygro Transmitter uses 2 x AA, IEC, LR6,
1.5V batteries. To install and replace the batteries,
please follow the steps below:
1.
2.
Remove the cover.
Insert the batteries, observing the correct polarity
(see marking).
3.
Replace the battery cover.
Note:
In the event of changing batteries in any of the units, all units need to be
reset by following the setting up procedures. This is due to a random
security code assigned by the transmitter at start-up. This code must be
1.
Insert finger or other solid object in the space at the bottom center
of the battery compartment and lift up to remove the cover.
9
10
2.
3.
Insert batteries observing the correct polarity (see marking).
Replace compartment cover.
ABOUT WWVB RADIO CONTROLLED TIME
The NIST (National Institute of Standards and Technology—Time and
Frequency Division) WWVB radio station is located in Ft. Collins,
Colorado, and transmits the exact time signal continuously throughout the
United States at 60 kHz. The signal can be received up to 2,000 miles
away through the internal antenna in the weather projection station.
However, due to the nature of the Earth’s Ionosphere, reception is very
limited during daylight hours. The wireless weather station will search for
a signal every night when reception is best.
BATTERY CHANGE:
It is recommended to replace the batteries in all units on an annual basis
to ensure optimum accuracy of these units.
Please participate in the preservation of the
environment. Return used batteries to an authorized
depot.
The WWVB radio station receives the time data from the NIST Atomic
clock in Boulder, Colorado. A team of atomic physicists is continually
measuring every second, of every day, to an accuracy of ten billionths of
a second per day. These physicists have created an international
standard, measuring a second as 9,192,631,770 vibrations of a Cesium-
133 atom in a vacuum. For more detail, visit
(303)499-7111. This number will connect you to an automated time,
announced at the top of the minute in “Coordinated Universal Time”,
which is also known as Greenwich Mean Time (GMT). This time does not
follow Daylight Saving Time changes. After the top of the minute, a tone
DEVICE RESET
The Weather Station and the Thermo-hygro transmitter need to be reset
when one of the following conditions occur:
Unsuccessful 915 MHz signal reception.
Malfunction on the units.
Batteries replacement.
For resetting, remove all batteries from the units. Wait at least for 1
minute before powering up the Weather station again. Proceed from step
1 in “Setting Up”.
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
will sound for every second. It is possible that your wireless weather
station may not be exactly on the second due to the variance in the
quartz. However, the clock will adjust the quartz timing over the course of
several days to be very accurate; under 0.10 seconds per day.
hour display, manual time setting, calendar, temperature °F/°C,
pressure hPa/inHg, relative pressure value, and weather icon
sensitivity setting
Reset all MIN/MAX records
Stop the alarm during alarm ringing
Stop snooze mode
FUNCTION KEYS:
The Weather Station has 5 easy to use function keys:
ALM/DATE key
ALM/DATE key
Press and hold key for 3 seconds to enter the alarm setting mode
SET key IN key
SNOOZE/CH key
OUT/+ key
Active/de-active the alarm time
Stop the alarm during alarm ringing
Stop snooze mode
Display date
IN key
Press to toggle between MAX/MIN and current indoor
temperature/humidity data
Press to set the alarm hour (inside alarm setting mode)
Decrease relative pressure value (within manual set mode)
Stop the alarm during alarm ringing
SET key
Press and hold the key to enter manual setting modes: LCD
contrast, time zone, DST ON/OFF, time reception ON/OFF, 12/24
Stop snooze mode
13
14
Alarm icon
Time reception icon
(for WWVB time)
Moon phase
icon
OUT/+ key
Calendar
or alarm
time
Press shortly to toggle between MAX/MIN and current outdoor
temperature/humidity data
Time
Increase, change, toggle all values in manual set mode
Press to set the alarm minute (inside alarm setting mode)
Stop the alarm during alarm ringing
Stop snooze mode
Low battery
indicator
Indoor
Indoor relative
humidity in
RH%
temperature
in °F/°C
Comfort
SNOOZE/CH key
indicator icon
Weather
tendency
indicator
Active snooze function during alarm ringing
Relative air
pressure history
Exit the manual set mode and alarm setting mode
Switch among display of channels (if more than 1 transmitter is
used)
Relative air
pressure in
hPa / inHg
Weather
forecast
icon
LCD SCREEN
Outdoor
relative
humidity in
RH%
The LCD screen is split into 4 sections displaying the information for
time/calendar/alarm/moon phase, indoor data, weather forecast and
outdoor data.
Outdoor
temperature in
°F/°C
Remote transmitter
number (if more than 1
transmitter is used)
Outdoor data
signal reception
indicator*
15
16
Download from Www.Somanuals.com. All Manuals Search And Download.
* When the signal is successfully received by the Weather Station, the
outdoor transmission icon will be switched on. If not successful, the
icon will not be shown on LCD. The user can then easily see whether the
last reception was successful (icon on) or not (icon off). A short blinking of
the icon indicates that signal reception is currently taking place.
Note: SET mode is entered by pressing and holding the SET key for 3
seconds. If you do not press any keys for 15 seconds while in SET
mode, the Weather Station switches out of SET mode.
LCD CONTRAST SETTING:
MANUAL SETTINGS:
The following manual settings can be changed when pressing the SET
key:
Last digit flashing
LCD contrast setting
Time zone setting
DST ON/OFF setting
Time reception ON/OFF setting
12/24-hour format setting
Manual time setting
The LCD contrast can be set within 8 levels, from LCD 0 to LCD7 (Default
setting is LCD 4):
1.
2.
3.
Press and hold the SET key until the digit starts flashing.
Use the OUT/+ key to view all levels of contrast.
Select the desired LCD contrast. Confirm with the SET key and
enter in the Time Zone setting.
Calendar setting
TIME ZONE SETTING:
°F/°C temperature setting
Air pressure setting (hPa / inHg)
Relative air pressure setting
Weather forecasting icon sensitivity setting
Flashing
17
18
TIME RECEPTION ON/OFF SETTING:
The time zone default of the Weather Station is “-5h”. U.S. time zones are
negative numbers: –5h(EST), -6h(CST), -7h(MST) and –8h(PST).To set
a different time zone:
Flashing
1.
2.
The current time zone value starts flashing.
Use the OUT/+ key to set the time zone. The range runs from 0 to -
12 and then runs from +12 back to 0 in consecutive 1-hour
intervals.
Confirm with the SET key and enter the Daylight saving time
ON/OFF.
In areas where reception of the WWVB time is not possible, the WWVB
time reception function can be turn OFF. The clock will then work as a
normal Quartz clock. (Default setting is ON).
3.
4.
5.
6.
“ON” will start flashing on the LCD and "RCC" will display.
Use the OUT/+ key to turn OFF the time reception function.
Confirm with the SET key and enter the 12/24-hour format
setting.
DAYLIGHT SAVING TIME ON/OFF SETTING (DST ON/OFF)
Note: If the Time Reception function is turned OFF, the clock will not
attempt reception of the WWVB time. The time reception icon and
the “WWVB” icon will not be displayed on the LCD. Time Reception
must be set to "ON" for the WVVB atomic time to function.
Flashing
1.
2.
“ON” will flash on the LCD and "DSt" will display.
Use the OUT/+ key to turn the daylight saving time function ON or
OFF.
3.
Confirm with the SET key and enter the Time reception ON/OFF
setting.
19
20
Download from Www.Somanuals.com. All Manuals Search And Download.
12/24-HOUR FORMAT SETTING:
1.
2.
3.
The hour digit will start flashing.
Use the OUT/+ key to set the hour.
Press again the SET key to set the minutes. The minute digits start
flashing.
Flashing
4.
5.
Use the OUT/+ key to set the minutes.
Confirm with the SET key and enter the Calendar setting.
The hour display can be selected to show hours in 12-hour or 24-hour
settings. (Default 12-Hour)
Note: If the WWVB reception function is set to "ON", the unit will still try to
receive the WWVB time signal between midnight and 6:00 am every day,
even if the time was set manually. When it does receive the signal, it will
change the manually set time into the received time. During reception
attempts, the WWVB tower icon will flash. If reception has been
unsuccessful, then the WWVB tower icon will not appear but reception
will still be attempted the following hour.
1.
2.
Use the OUT/+ key to toggle between “12H” or “24H”.
Confirm with the SET key and enter the Manual time setting.
MANUAL TIME SETTING:
If Weather Station cannot detect the WWVB-signal due to disturbances,
transmission distance, etc., the time can be set manually. The clock will
then work as a normal Quartz clock.
CALENDAR SETTING:
Hour flashing
Year
Minutes flashing
21
22
Note: The Day of the Week will set automatically when the year, month
and date are set.
°C/°F TEMPERATURE SETTING:
Month and date
(12hr time format)
Date and month
(24hr time format)
Flashing
Note: When set to 24-hour time, the calendar setting mode will display
the date to the left of the month.
The date default of the Weather station is 1. 1. 2006. Once the radio-
controlled time signals are received, the date is automatically updated. If
the signals are not received, the date can also be set manually.
The temperature display can be selected to show temperature data in °C
or °F (Default °F).
1.
2.
Use the OUT/+ key to toggle between “°C” or “°F”.
Confirm with the SET key and enter the Air pressure unit setting.
1.
2.
3.
The year starts flashing.
Use the OUT/+ key to set the year (between year 2003-2029).
Press the SET key again to confirm and to enter the month setting.
The month starts flashing.
AIR PRESSURE UNIT SETTING (hPa / inHg):
The pressure display can be selected to show relative air pressure in hPa
or inHg (default is “inHg”).
4.
5.
Use the OUT/+ key to set the month.
Press the SET key again to confirm and to enter the date setting
mode. The date starts flashing.
Flashing
6.
7.
Use the OUT/+ key to set the date.
Confirm all calendar settings with the SET key and enter the
Temperature unit setting.
1.
Use the OUT/+ key to toggle between “hPa” or “inHg” unit
24
23
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
Confirm with the SET key and enter the Relative air pressure
value setting.
WEATHER FORECASTING ICON SENSITIVITY SETTING:
For locations with rapid changes of weather conditions, the weather icons
sensitivity can be set to a different level for faster display of weather
conditions.
Note:
Units of weather icon sensitivity and air pressure history are not affected.
They are always expressed in hPa.
RELATIVE AIR PRESSURE VALUE SETTING
The default relative pressure value is 29.92 inHg (1013 hPa). This can be
manually set to another value within the range of 28.35 – 30.72 inHg (960
– 1040 hPa) for a better reference.
Flashing
1.
2.
The current sensitivity value will start flashing.
Use the OUT/+ key to set the weather sensitivity level. There are 3
levels of setting: 2, 3 and 4. The value corresponds to the change
of air pressure in hPa before the weather icon will switch to another
state. Level 2 is the most sensitive setting (coastline); level 4 is the
slowest (desert) recording setting (default setting is "3").
Confirm with the SET key and exit the Manual settings.
Flashing
1.
2.
The current relative pressure value will start flashing
Use the OUT/+ key to increment and IN key to decrement the
value. Holding the key allows the value to advance faster.
Confirm with the SET key and enter the Weather forecast icon
sensitivity setting.
3.
3.
25
26
To view and activate the alarm, press the ALM/DATE key. The
alarm icon (()) and the alarm time will be displayed, indicating that
the alarm setting is activated.
TO EXIT THE MANUAL SETTING MODE
To exit the manual setting mode anytime during the manual setting, press
the SNOOZE/CH key or wait for automatic timeout. The mode will return
to normal time display.
The maximum alarm ring duration is 2 minutes.
ALARM SETTING:
SNOOZE SETTING AND STOPPING THE ALARM:
The 10 minute snooze function can be set when the alarm is ringing by
pressing the SNOOZE/CH key.
Alarm icon
Alarm time
When the alarm is snoozing, the alarm icon (()) will remain flashing
indicating that the alarm is active but is in Snooze mode. To stop the
snooze function when it is in snooze period, press any key except the
SNOOZE/CH key.
The alarm time can be set when pressing the ALM/DATE key.
1.
Press and hold the ALM/DATE key to enter the alarm set mode.
The alarm digits flash.
To stop the alarm, press any key (except for SNOOZE/CH) while the
alarm is ringing.
2.
3.
4.
Use the IN key to set the alarm hour.
Use the OUT/+ key to set the alarm minute.
Confirm with SNOOZE/CH key and exit the Alarm setting. The
icon ((●)) will be displayed along with the set alarm time.
MOON PHASES SYMBOL
The Moon icon of the Weather station will also display all 12 Moon
phases throughout the year according to the set calendar.
Note: If the calendar is displayed in the Weather station, the alarm is
NOT active.
27
28
Download from Www.Somanuals.com. All Manuals Search And Download.
THE COMFORT LEVEL INDICATOR:
Comfortable
:
A happy face icon “” indicating a temperature
level between 68*F and 78.6 *F (20°C and 25.9°C)
and relative humidity reading between 45% and
65%.
Large
Waxing
Crescent
Small
Waxing
Gibbous
Small
Waxing
Crescent
Large
Waxing
Gibbous
First
Quarter
New Moon
Uncomfortable
:
A sad face icon “” indicating any value outside the
comfortable range.
TOGGLING AND RESETTING THE INDOOR READINGS:
Last
Quarter
Small
Waning
Gibbous
Large
Waning
Gibbous
Large
Waning
Crescent
Small
Waning
Crescent
Full Moon
1.
To toggle between the current indoor and the MAX/MIN indoor
temperature and humidity data and the times (for temperature data
only) they were recorded press the IN key:.
-
Once to show the MAX indoor temperature and humidity
data with the recorded time and date.
INDOOR RELATIVE HUMIDITY AND INDOOR TEMPERATURE:
The indoor temperature and humidity data and the indoor comfort
indicator are automatically updated and displayed on the second section
-
Twice to show the MIN indoor temperature and humidity data
with the recorded time and date.
of the LCD.
MAX icon
-
2.
Three times to return to the current displayed values
Once the MIN or MAX data is displayed, press and hold the SET
key for 3 seconds to reset the respective MIN or MAX record to
current temperature and humidity data, and current time, date
display.
Indoor
Indoor
temperature
in °C or ºF
relative
humidity
in RH%
29
30
Note: The MIN or MAX data needs to be reset individually.
The icons displayed forecast the weather in terms of getting better or
worse and not necessarily sunny or rainy as each icon indicates. For
example, if the current weather is cloudy and the rainy icon is displayed, it
does not mean that the product is faulty because it is not raining. It simply
means that the air pressure has dropped and the weather is expected to
get worse but not necessarily rainy.
WEATHER FORECAST AND WEATHER TENDENCY:
WEATHER FORECASTING ICONS:
Weather icons in the third section of LCD can be displayed in any of the
following combinations:
Note:
FORECAST
FORECAST
FORECAST
After setting up, readings for weather forecasts should be disregarded for
the next 48-60 hours. This will allow sufficient time for the Weather station
to collect air pressure data at a constant altitude and therefore result in a
more accurate forecast.
Sunny
Cloudy with sunny intervals
Rainy
Common to weather forecasting, absolute accuracy cannot be
guaranteed. The weather forecasting feature is estimated to have an
accuracy level of about 75% due to the varying areas the Weather station
has been designed for use in. In areas that experience sudden changes
in weather (for example from sunny to rain), the Weather station will be
more accurate compared to use in areas where the weather is constant
most of the time (for example mostly sunny).
For every sudden or significant change in the air pressure, the weather
icons will update accordingly to represent the change in weather. If the
icons do not change, then it means either the air pressure has not
changed or the change has been too slow for the Weather station to
register. If the icon displayed is a sun or raining cloud, there will be no
change of icon if the weather gets any better (with sunny icon) or worse
(with rainy icon), since the icons are already at their extremes.
31
32
Download from Www.Somanuals.com. All Manuals Search And Download.
If the Weather station is moved to another location significantly higher or
lower than its initial standing point (for example from the ground floor to
the upper floors of a house), discard the weather forecast for the next 48-
60 hours. By doing this, the Weather Station will not mistake the new
location as being a possible change in air-pressure when really it is due
to the slight change of altitude.
Note: Once the weather tendency indicator has registered a change in air
pressure, it will remain permanently displayed on the LCD.
AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH
BAROMETRIC PRESSURE TREND)
The third section of the LCD also shows the relative air pressure value
and the air pressure history.
WEATHER TENDENCY INDICATOR
Working together with the weather icons are the weather tendency
indicators (located on the left and right sides of the weather icons). When
the indicator points upwards, it means that the air-pressure is increasing
and the weather is expected to improve. When the indicator points
downwards, the air-pressure is dropping and the weather is expected to
become worse.
Air pressure over the last 24 hours
The bar chart indicates the air pressure history trend over the last 24
hours in 7 steps, 0h, -3h, -6h, -9h, -12h, -18h, and -24h. The “0h”
represents the current full hour air pressure recording. The columns
represent the “hPa” (0, ±2, ±4, ±6) at specific time. The “0” in the middle
of this scale is equal to the current pressure and each change (±2, ±4, ±6)
represents how high or low in “hPa“ the past pressure was compared to
the current pressure.
Taking this into account, one can see how the weather has changed and
is expected to change. For example, if the indicator is pointing
downwards together with cloud and sun icons, then the last noticeable
change in the weather was when it was sunny (the sun icon only).
Therefore, the next change in the weather will be cloud with rain icons
since the indicator is pointing downwards.
33
34
If the bars are rising it means that the weather is getting better due to the
increase of air pressure. If the bars go down, it means the air pressure
has dropped and the weather is expected to get worse from the present
time “0h“.
1.
2.
To toggle between the current outdoor and the MAX/MIN outdoor
temperature and humidity data and the times (for temperature data
only) they were recorded press the OUT/+ key:
- Once to show the MAX outdoor temperature and humidity data
with the recorded time and date.
Note:
- Twice to show the MIN outdoor temperature and humidity data
with the recorded time and date.
For accurate barometric pressure trends, the Weather Station should
operate at the same altitude. For example, it should not be moved from
the ground to the second floor of the house. Should the unit be moved to
a new location, discard readings for the next 48-60 hours.
- Three times to return to the current displayed values.
Once the MIN or MAX data is displayed, press and hold the SET
key for 3 seconds to reset the respective MIN or MAX record to
current temperature and humidity data, and current time, date
display.
OUTDOOR TEMPERATURE AND HUMIDITY DATA
The fourth LCD section shows the outdoor temperature and humidity, the
reception indicator, the transmitter identification number and the
Note: The MIN or MAX data needs to be reset individually.
MIN/MAX outdoor data.
Outdoor transmitter
identification number
TO VIEW THE MIN/MAX DATA FROM DIFFERENT
TRANSMITTERS
When more than 1 transmitter used:
MIN icon
Outdoor
relative
humidity
in RH%
Outdoor
temperature
in °C/ °F
1.
To toggle between transmitters, press the SNOOZE/CH key:
Once to show transmitter 2
TOGGLING AND RESETTING THE OUTDOOR DATA
Twice to show transmitter 3
Three times to return to transmitter 1
35
36
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
3.
Use OUT/+ key to view the MIN/MAX temperature and humidity
data for the selected transmitter.
CHECKING FOR 915MHz RECEPTION
If the outdoor temperature and humidity data are not being received
within three minutes after setting up (or outdoor display always show “-
-. -” in the outdoor section of the Weather station during normal
operation), please check the following points:
To reset the minimum and maximum temperature and humidity
data, and the times at which they were recorded, press the SET
key continuously for about 3 seconds. This will reset the MIN/MAX
data recorded to the current time, date, temperature and humidity.
The current time taken is the normal displayed time and does not
regard the time zone set for the unit.
1.
The distance of the Weather station or transmitters should be at
least 5 to 6.5 feet (1.5 to 2 meters) away from any interfering
sources such as computer monitors or TV sets.
Note: The MIN/MAX data for each transmitter needs to be reset
2.
3.
Avoid placing the transmitters onto or in the immediate proximity of
metal window frames.
separately.
LOW BATTERY INDICATOR
Low battery indicator is displayed on the LCD when the batteries in the
weather station require changing.
Using other electrical products such as headphones or speakers
operating on the 915MHz-signal frequency may prevent correct
signal transmission or reception. Neighbors using electrical devices
operating on the 915MHz-signal frequency can also cause
interference.
ABOUT THE OUTDOOR TRANSMITTER
The range of the Thermo-hygro transmitter may be affected by the
temperature. At cold temperatures, the transmitting distance may be
decreased. Please keep this in mind when positioning the transmitters.
Battery power may be reduced for the Thermo-hygro transmitter at cold
temperatures.
Note: When the 915MHz signal is received correctly, do not re-open the
battery cover of either the transmitter or Weather station, as the batteries
may spring free from the contacts and force a false reset. Should this
37
38
happen accidentally, reset all units (see “Setting up” above), or
FOLDOUT TABLE STANDS:
transmission problems may occur.
The foldout table stands legs are located on the
backside. Simply unfold the stands on the back. Once
the foldout table stands are extended, place the weather
station in an appropriate location.
The transmission range is around 300 feet from the Thermo-hygro
transmitter to the Weather station (in open space). However, this
depends on the surrounding environment and interference levels. If no
reception is possible despite the observation of these factors, all system
units have to be reset (see “Setting up” above).
POSITIONING THE WEATHER STATION
The Weather station provides the option of table standing or
wall mounting the unit. Before wall mounting, please check
that the outdoor data can be received from the desired
locations.
POSITIONING THE THERMO/HYGRO TRANSMITTER:
The remote thermo/hygro transmitter can be placed onto
any flat surface or wall mounted using the bracket which
doubles as a stand or wall mount base.
TO WALL MOUNT:
1. Fix a screw (not supplied) into the desired wall, leaving
the head extended out by about 0.2” (5mm).
2. Place the weather station onto the screw, using the
hanging hole on the backside. Gently pull the weather
station down to lock the screw into place.
TO WALL MOUNT:
1. Secure the bracket onto a desired
wall using the screws and plastic anchors.
39
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Do not submerge the units in water. Furthermore, fix all parts in
place where the units are adequately protected against moisture
and rain.
Immediately remove all low powered batteries to avoid leakage and
damage. Replace only with new batteries of the recommended
type.
Do not make any repair attempts to the unit. Return them to their
original point of purchase for repair by a qualified engineer.
Opening and tampering with the unit may invalidate their
guarantee.
Do not expose the units to extreme and sudden temperature
changes, this may lead to rapid changes in forecasts and readings
and thereby reduce their accuracy.
2. Clip the remote temperature transmitter onto the
bracket.
Note:
The mounting surface can affect the transmission range. If, for instance,
the unit is attached to a piece of metal, it may then either reduce or
increase the transmitting range. For this reason, we recommend not to
place the unit on any metal surfaces or in any position where a large
metal or highly polished surface is in the immediate vicinity (garage
doors, double glazing, etc.). Before securing in place, please ensure that
the Temperature Station can receive the 915MHz signal from the
temperature transmitter at the positions that you wish to place them.
CARE AND MAINTENANCE:
SPECIFICATIONS:
Extreme temperatures, vibrations and shocks should be avoided as
these may cause damage to the unit and give inaccurate forecasts
and readings.
Temperature measuring range:
When cleaning the display and casings, use a soft damp cloth only.
Do not use solvents or scouring agents as they may mark the LCD
and casings.
Indoor
:
14.2ºF to 139.8ºF with 0.2ºF resolution
-9.9ºC to +59.9ºC with 0.1°C resolution
(“OF.L” displayed if outside this range)
41
42
Outdoor
:
-39.8ºF to +139.8ºF with 0.2ºF resolution
-39.9ºC to +59.9ºC with 0.1°C resolution
(“OF.L” displayed if outside this range)
Battery life
:
up to 24 months
Dimensions (L x W x H):
Weather station
Indoor humidity range
:
1% to 99% with 1% resolution
:
7.49“ x 1.33“ x 7.65“ / 190.4 x 37 x 190.4 mm
(Display “- -“ if temperature is OL.F; display “- -“ if < 1% and “99%” if >
99%)
Thermo-hygro transmitter
:
1.50” x 0.83” x 5.05” /
38.2mm x 21.2mm x 128.3mm
Outdoor humidity range
(Display “- -“ if outside temperature is OF.L; display 1% if < 1% and 99%
:
1% to 99% with 1% resolution
WARRANTY
La Crosse Technology, Ltd provides a 1-year limited warranty on this
product against manufacturing defects in materials and workmanship.
if > 99%)
Interior data checking intervals
Indoor Temperature
Humidity
Air pressure checking interval
:
:
:
Every 15 seconds
Every 20 seconds
Every 15 seconds
This limited warranty begins on the original date of purchase, is valid only
on products purchased and used in North America and only to the original
purchaser of this product. To receive warranty service, the purchaser
must contact La Crosse Technology, Ltd for problem determination and
service procedures. Warranty service can only be performed by a La
Crosse Technology, Ltd authorized service center. The original dated bill
of sale must be presented upon request as proof of purchase to La
Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized
service center.
Outdoor temperature and humidity data checking interval:
Every 4 seconds
Transmission range
-
:
up to 330 feet (open space)
Power consumption: (alkaline batteries recommended)
Weather station
Thermo-hygro transmitter
:
:
2 x C, IEC LR14, 1.5V
2 x AA, IEC LR6, 1.5V
La Crosse Technology, Ltd will repair or replace this product, at our
option and at no charge as stipulated herein, with new or reconditioned
43
44
Download from Www.Somanuals.com. All Manuals Search And Download.
parts or products if found to be defective during the limited warranty
period specified above. All replaced parts and products become the
property of La Crosse Technology, Ltd and must be returned to La
Crosse Technology, Ltd. Replacement parts and products assume the
remaining original warranty, or ninety (90) days, whichever is longer. La
Crosse Technology, Ltd will pay all expenses for labor and materials for
all repairs covered by this warranty. If necessary repairs are not covered
by this warranty, or if a product is examined which is not in need or repair,
you will be charged for the repairs or examination. The owner must pay
any shipping charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service center. La
Crosse Technology, Ltd will pay ground return shipping charges to the
owner of the product to a USA address only.
alterations by someone other than an authorized La Crosse Technology,
Ltd authorized service center; (6) units used for other than home use (7)
applications and uses that this product was not intended or (8) the
products inability to receive a signal due to any source of interference.
This warranty covers only actual defects within the product itself, and
does not cover the cost of installation or removal from a fixed installation,
normal set-up or adjustments, claims based on misrepresentation by the
seller or performance variations resulting from installation-related
circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR
DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION
OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR
MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS
PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH.
Your La Crosse Technology, Ltd warranty covers all defects in material
and workmanship with the following specified exceptions: (1) damage
caused by accident, unreasonable use or neglect (including the lack of
reasonable and necessary maintenance); (2) damage occurring during
shipment (claims must be presented to the carrier); (3) damage to, or
deterioration of, any accessory or decorative surface; (4) damage
resulting from failure to follow instructions contained in your owner’s
manual; (5) damage resulting from the performance of repairs or
This warranty gives you specific legal rights. You may also have other
rights specific to your State. Some States do no allow the exclusion of
consequential or incidental damages therefore the above exclusion of
limitation may not apply to you.
For warranty work, technical support, or information contact:
46
45
La Crosse Technology, Ltd
2809 Losey Blvd S
La Crosse, WI 54601
All rights reserved. This handbook must not be reproduced in any form, even in
excerpts, or duplicated or processed using electronic, mechanical or chemical
procedures without written permission of the publisher.
This handbook may contain mistakes and printing errors. The information in this
handbook is regularly checked and corrections made in the next issue. We accept no
liability for technical mistakes or printing errors, or their consequences.
All trademarks and patents are acknowledged.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
|