TABLE OF CONTENTS
Topic
Inventory of Contents/Additional Equipment
About WWVB
WS-9153U-IT
Wireless 915 MHz
Radio-controlled Weather Station
Page
3
3
4
Quick Set-Up Guide
Detailed Set-Up Guide
Battery installation
Program Mode
Instruction Manual
5
Program Sequence and Default Settings
Function Keys
6
6
Setting the LCD Contrast
Setting the Time Zone
Daylight Saving Time Setting
Radio-controlled Time Setting
12/24-hour Time Setting
Setting the Time
Setting the Year, Day and Month
Setting the Snooze
Setting the Temperature Format
Setting the Forecast Sensitivity
Features
7
7-8
8
9
9
10-11
11
12
12
13
Weather Forecast Icons and Tendency Arrows
Indoor Temperature, Humidity, & Comfort
Level Indicator
14-15
15-16
Outdoor Temperatures
Minimum & Maximum Records (Indoor,
Outdoor, & Resetting)
16
16-17
Additional Remote Control Sending Units (Set-Up, Viewing,
& Operation)
18-19
Mounting
Troubleshooting
Maintenance & Care
19-21
22-23
23
Specifications
24
Warranty Information
25-26
2
signal continuously throughout the United States at 60 kHz. The signal can be received up to
2,000 miles away through the internal antenna in the Weather Station. However, due to the
nature of the Earth’s Ionosphere, reception is very limited during daylight hours. The Weather
Station will search for a signal every night when reception is best. The WWVB radio station
derives its signal from the NIST Atomic clock in Boulder, Colorado. A team of atomic physicists
is continually measuring every second, of every day, to an accuracy of ten billionths of a second
per day. These physicists have created an international standard, measuring a second as
9,192,631,770 vibrations of a Cesium-133 atom in a vacuum. For more information on the
atomic clock and WWVB please see the NIST website at
This product offers:
INSTANT TRANSMISSION is the state-
of-the-art new wireless transmission
technology, exclusively designed and
developed
by
LA
CROSSE
TECHNOLOGY.
INSTANT
TRANSMISSION
offers
you
an
immediate update (every 4 seconds!) of
all your outdoor data measured from
the sensors: follow your climatic
variations in real-time!
QUICK SET-UP GUIDE
Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries.
1. Have the Wireless Weather Station and remote temperature sensor 3 to 5 feet apart.
2. Batteries should be out of both units for 10 minutes.
3. Place the batteries into the remote temperature sensor first then into the indoor
weather station.
(All remote temperature sensors must be started before the Wireless Weather Station)
4. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES.
INVENTORY OF CONTENTS
1. The Wireless Weather Station/ (Figure 1).
2. One remote temperature sensor with mounting bracket (Figure 2).
3. Three each, ½” Philips screws.
4. One strip double-sided adhesive tape.
In this time the Wireless Weather Station and remote temperature sensor will start to talk to each
other and the display will show both the indoor temperature and humidity, and an outdoor
temperature. If the Wireless Weather Station does not display both temperatures after the 15
minutes please retry the set up as stated above. After both indoor and outdoor temperatures are
displayed for 15 minutes you can place your remote temperature sensor outdoor and set your
time.
5. Instruction manual and warranty card.
Figure 1
Time LCD
The remote temperature sensor should be placed in a dry, shaded area. The temperature
sensor has a range of 330 feet. Keep in mind that the 330 feet is in open air with no
obstructions and that radio waves DO NOT curve around objects. Actual transmission range will
vary depending on what is in the path of the signal. Each obstruction (roof, walls, floors,
ceilings, thick trees, etc.) will effectively cut signal range in half.
Date LCD
Forecast LCD
Example: A Wireless Weather Station with a 330 feet range is mounted on an interior wall, so
that the signal has to pass through one interior wall, one exterior wall, and across the 10 feet
width of the room between the 2 walls. The first wall will reduce the range to 165 feet, and the
second wall will reduce the range to 87 feet. Factoring in the 10 foot room, this leaves a
maximum of 77 feet of remaining signal range.
Indoor LCD
Mounting
Bracket
TX29U-IT remote
temperature sensor
Outdoor LCD
Figure 2
This allowance is typically enough for a frame wall with non-metallic siding; however certain
materials can reduce range even further. Metal siding, stucco, and some types of glass can
reduce signal range by as much as ¾ or more, compared to the ½ reduction typical of most
obstructions. It is possible to receive a signal through these materials, however maximum range
will be much less due to their tendency to absorb or reflect a much larger portion of the sensor’s
signal.
ADDITIONAL EQUIPMENT (not included)
1. Two fresh AA 1.5V Alkaline batteries for the Wireless Weather Station.
2. Two fresh AA 1.5V Alkaline batteries for the remote temperature sensor.
3. One, Philips screwdriver for mounting.
To complete the set up of your Wireless Weather Station after the 15 minutes have passed
please follow the steps that follow in the Detailed Set-Up Guide.
ABOUT WWVB (Radio Controlled Time)
The NIST (National Institute of Standards and Technology—Time and Frequency Division)
WWVB radio station is located in Ft. Collins, Colorado, and transmits the exact time and date
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
VIII.
TIME SETTING
There are two methods by which the time and date can be set:
A) Automatically via WWVB reception, or
B) Manually.
8. Press and release the IN button to advance the day.
9. Press and release the OUT button to advance the month.
10. Press and release the SET button to confirm and advance to the snooze
setting.
A. WWVB (Remote Control Time)
This method requires you to do nothing, except wait for the signal to be received, and to select a
time zone. Reception usually takes approximately 10 minutes during optimal conditions. The
best condition for reception is at night, between midnight and 6:00 am—when there is less
atmospheric interference. To keep your time as accurate as possible, Wireless Weather Station
conducts a WWVB search every night between these hours, and overrides any manually set
time. The WWVB tower icon (appearing in the TIME LCD) will flash when a signal-search is in
progress and a signal is being received, and will remain steady when the signal has been
received. If the WWVB time has not been received after 10 minutes of battery installation, you
may manually set the time or leave the time function alone (reception will occur regardless).
After a successful reception, no more reception attempt would be made until the following day.
X.
SETTING THE SNOOZE
Note: This is an unused function of the Wireless Weather Station and should be
disregarded. The setting has no bearing on the operation. Please press and release
the SET button to advance to select the temperature format.
XI.
SELECTING °F OR °C
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button nine times.
4. Either ”°F” or “°C” will flash in the time LCD.
B. MANUAL TIME SETTING
Note: When in the 12-hour format “P.M.” will appear to the left of the hour in the
time LCD between the hours of noon and midnight.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button five times.
4. The time will flash in the time LCD.
5. Press and release the IN button to select the temperature format.
6. Press and release the SET button to confirm and advance to the forecast
sensitivity setting.
XII. SETTING THE FORECAST SENSITIVITY
Note: The forecast sensitivity can be adjusted to allow for areas that have a
higher or lower sensitivity to changing air pressure (for example coastal
areas have more pressure change than areas such as southern Arizona).
5. Press and release the IN button to advance the hours.
6. Press and release the OUT button to advance the minutes.
7. Press and release the SET button to confirm and advance to the year
setting.
The numbers correspond to the amount of air pressure change necessary to
trigger a change in the forecast icon. Areas that tend to have more air
pressure change would set the sensitivity to 3, while areas that experience
lower than normal air pressure change would set the sensitivity to 1.
IX.
SETTING THE YEAR, DAY AND MONTH
Note: Reception of the WWVB signal will also set the date and day. The
reception of the signal will override any programmed date and day.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button ten times.
1. Press and hold the SET button for 5 seconds.
2. “LCD” will show in the time LCD and the number setting will flash.
3. Press and release the SET button six times.
4. The year will flash in the date LCD.
4. Either “1”, “2” or “3” will flash in the time LCD.
5. Press and release the IN button to advance the year.
6. Press and release the SET button to confirm and advance to the day/month
setting.
7. The day and month will flash in the date LCD.
9
10
Sunny—indicates that the weather is expected to improve (not that the
weather will be sunny).
Sun with Clouds—indicates that the weather is expected to be fair (not that
the weather will be sunny with clouds).
Clouds with Rain—indicates that the weather is expected to get worse (not
that the weather will be rainy).
These icons indicate the expected weather change in the next 12 to 24
hours. The icon does not give an exact prediction of the weather, however it
should be viewed as a generalization of the expected weather change (for
example a “sunny” icon indicates the weather is expected to improve).
5. Press and release the IN button to select the forecast sensitivity
6. Press and release the SET button to confirm the forecast sensitivity and
complete the programming.
The weather icons change when the unit detects a change in air pressure.
The icons change in order, from “sunny” to “partly sunny” to “cloudy” or the
reverse. It will not change from “sunny” directly to “rainy”, although it is
possible for the change to occur quickly. If the symbols do not change then
the weather has not changed, or the change has been slow and gradual.
FEATURES OF THE WS-9153U-IT
WWVB Tower Icon
(indicates time
reception)
B. WEATHER TENDENCY ARROWS
Other possible displays in the FORECAST LCD are 2 weather tendency
arrows, one that points up (on the left side of the LCD) and one that points
down (on the right side of the LCD). These arrows reflect current changes
in the air pressure. An arrow pointing up indicates that the air pressure is
increasing and the weather is expected to improve or remain good, an arrow
pointing down indicates that the air pressure is decreasing and the weather
is expected to become worse or remain poor.
Weather Tendency Arrow
Forecast icon
Comfort Level Indicator
II. INDOOR TEMPERATURE, HUMIDITY, AND COMFORT LEVEL INDICATOR
The current indoor temperature (viewed on the left) and relative humidity (viewed on
the right) are displayed in the INDOOR LCD. The comfort level indicator is located at
the center of the INDOOR LCD. The indicator will display a happy face icon when the
temperature is between 68°F and 79°F (20°C and 25.9°C), and the humidity is
between 45% and 65%. A sad face icon will be displayed when the temperature and
humidity are outside the mentioned ranges.
Remote Sensor Number
(Up to 3 Total)
Satellite icon
(indicates outdoor
I. WEATHER FORECAST
The weather forecasting feature is estimated to be 75% accurate and is for the next 12
to 24 hours. The weather forecast is based solely upon the change of air pressure
over time. The WS-9153U-IT averages past air-pressure readings to provide an
accurate forecast—creating a necessity to disregard all weather forecasting for 12-24
hours after the unit has been set-up, reset, or moved from one altitude to another (i.e.
from one floor of a building to another floor). In areas where the weather is not largely
affected by the change of air pressure, the sensitivity setting should be set to 1.
A. WEATHER ICONS
III. OUTDOOR TEMPERATURE
The temperature received from the remote temperature sensor is viewed in the
OUTDOOR LCD. When there is more than one remote temperature sensor unit in
operation, a “boxed” number will appear to the right of the temperature. This indicates
which remote temperature sensor unit (1, 2, or 3) is currently displaying its data in the
OUTDOOR LCD. (This feature is explained in further detail in section V—Adding
Remote Temperature Sensors).
There are 3 possible weather icons that will be displayed in the FORECAST
LCD:
IV. MINIMUM AND MAXIMUM TEMPERATURE RECORDS
The WS-9153U-IT keeps a record of the MINIMUM and MAXIMUM temperature, and
the time and date of their occurrence—for both the indoor and outdoor modes.
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
The WS-9153U-IT is able to receive signals from 2 additional temperature sensors.
The following are instructions for the set-up of temperature sensor units with the WS-
9153U-IT. These extra sensors can be purchased through the same dealer as this
unit.
1. Remove all the batteries from the receiver and sensor(s) and wait 60 seconds.
During these 60 seconds, press any button 20 times to discharge any excess
power.
A. VIEWING THE INDOOR TEMPERATURE RECORDS
1. Press the IN button once. “MIN” appears above the indoor
temperature and the LCD will flash, indicating that the minimum
temperature and humidity, and the time and date of occurrence of the
temperature are displayed. The minimum records will display for 30
seconds before returning to the normal display mode.
2. Insert the batteries to the first temperature sensor.
3. Within 30 seconds of powering up the first sensor, insert the batteries to the
Weather Station. Once the batteries are in place, all segments of the LCD will
light up briefly. Following the indoor temperature and humidity, time as 12:00,
and calendar will be displayed. If they are not shown in LCD after 60 seconds,
remove the batteries and wait for at least 60 seconds before reinserting them.
4. The outdoor temperature from the first sensor (channel 1) should then be
displayed on the Weather Station. If this does not happen and the signal
reception icon is not shown, after 2 minutes, the batteries will need to be
removed from both units and reset from step 1.
5. Insert the batteries to the second sensor as soon as the outdoor temperature
readings from the first sensor are displayed on the Weather station.
NOTE: You must insert the batteries into the second sensor within 10
seconds of reception of the first sensor.
2. Press the IN button again (once while “MIN” is still displayed, twice
otherwise). “MAX” appears above the indoor temperature and the LCD
will flash, indicating that the maximum temperature and humidity, and
the time and date of occurrence of the temperature are displayed.
3. While “MAX” is still displayed press the IN button again to return to the
current data display. Or you can wait 30 seconds, during either the
minimum or the maximum readings, and the unit will automatically
return to current data readings.
B. VIEWING THE OUTDOOR TEMPERATURE RECORDS
1. Press the OUT button once. “MIN” appears above the outdoor
temperature and the LCD will flash, indicating that the minimum
temperature, and the time and date of occurrence are displayed. The
minimum records will display for 30 seconds before returning to the
normal display mode.
2. Press the OUT button again (once while “MIN” is still displayed, twice
otherwise). “MAX” appears above the outdoor temperature and the
LCD will flash, indicating that the maximum temperature and the time
and date of occurrence are displayed.
6. The outdoor temperature from the second sensor and the "channel 2" icon
should then be displayed on the Weather Station. If this does not happen after 2
minute, the batteries will need to be removed from all the units and reset from
step 1.
7. Insert the batteries to the third sensor as soon as the "channel 2" icon and
outdoor data are displayed on the Weather Station. Then within 2 minutes, the
channel 3 outdoor data from the third sensor will be displayed and the channel
icon will shift back to "1" once the third sensor is successfully received. If this is
not happen, user shall restart the setting up from step 1.
NOTE: You must insert the batteries into the third sensor within 10
seconds of reception of the second sensor.
IMPORTANT: Transmission problems will arise if the setting for multiple
sensors is not followed as described above. Should transmission problems
occur, it is necessary to remove the batteries from all units and start again
the set-up from step 1.
3. While “MAX” is still displayed press the OUT button again to return to
the current data display. Or you can wait 30 seconds, during either the
minimum or the maximum readings, and the unit will automatically
return to current data readings.
VI. VIEWING AND OPERATING WITH MULTIPLE REMOTE TEMPERATURE
SENSOR UNITS
C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS
1. All the Indoor records (minimum and maximum) will be reset after the
IN button is pressed and held for 5 seconds.
2. All the Outdoor records (minimum and maximum) will be reset after the
OUT button is pressed and held for 5 seconds.
1. To view the temperature of a different remote temperature sensor unit,
press and release the CH button. A shift from one “boxed” number to the
next should be observed in the OUTDOOR LCD.
2. To view the Minimum/Maximum temperature: first select which remote
temperature sensor to read data from (indicated by the “boxed” number),
then press the OUT button. Pressing this button once will display the
minimum temperature, and the date and time the data was recorded.
V. ADDING REMOTE TEMPERATURE SENSORS (OPTIONAL)
13
14
Pressing this button a second time (while “MIN” is still displayed, otherwise
press the button twice) will display the same data for the maximum
recordings.
5) Position the remote temperature sensor in the desired
location, ensuring that the Wireless Weather Station can
receive the signal.
6. To reset the Minimum/Maximum readings, it is necessary to select which
remote temperature sensor you wish to reset. Press and hold the OUT
button for 5 seconds, the records for the selected remote temperature
sensor unit will be reset.
Note: The adhesive tape is not intended to be used as a permanent mounting
solution. Only use the adhesive tape while you are positioning the Weather Station
and thermo-hygro sensor.
MOUNTING
Note: Before permanently mounting ensure that the Wireless Weather Station is able
to receive WWVB signals from the desired location. Also, extreme and sudden
changes in temperature will decrease the accuracy of the Wireless Weather Station,
and changes in elevation will result with inaccurate weather forecasting for the next 12
to 24 hours. These changes will require a 12 to 24 hour wait before obtaining reliable
data. To achieve a true temperature reading, avoid mounting where direct sunlight can
reach the remote temperature sensor or Wireless Weather Station. While the remote
temperature sensor is weather proof, avoid submersion in water or snow. We
recommend that you mount the remote temperature sensor on an outside North-facing
wall. The sending range is 330ft—obstacles such as walls, concrete, and large metal
objects can reduce the range. Place both units in their desired location, and wait
approximately 15 minutes before permanently mounting to ensure that there is proper
reception. The Wireless Weather Station should display a temperature in the
OUTDOOR LCD within 4 minutes of setting up.
Note: Mounting with adhesive tape is not recommended as a permanent mounting solution.
Only use the adhesive tape during set-up process.
II. THE WIRELESS WEATHER STATION
The Wireless Weather Station can be mounted in two ways:
with the table stand or,
on the wall with the use of a wall hanging screw (not included).
A. USING THE TABLE STAND
The Wireless Weather Station comes with the table stand
already mounted. If you wish to use the table-stand all that is
required is to place the Wireless Weather Station in an
appropriate location.
I. THE REMOTE TEMPERATURE SENSOR
The remote temperature sensor can be mounted in two ways:
•
•
with the use of screws, or
using the adhesive tape.
B. WALL MOUNTING
1) Remove the table-stand. To do this, pull down on the stand
from the rear and rotate forward.
A. MOUNTING WITH SCREWS
1) Remove the mounting bracket from the remote temperature
sensor.
2) Place the mounting bracket over the desired location.
3) Through the three screw holes of the bracket, mark the
mounting surface with a pencil.
4) Screw mounting bracket onto the mounting surface. Ensure
that the screws are flush with the bracket.
2) Fix
a
screw (not included) into the desired wall, leaving
approximately 3/16 of an inch (5mm) extended from the wall.
3) Place the Wireless Weather Station onto the screw using the
hanging hole on the backside.
4) Gently pull the Wireless Weather Station down to lock the
screw into place.
5) Insert the remote temperature sensor into the bracket.
TROUBLESHOOTING
NOTE: For problems not solved, please contact La Crosse Technology.
B. MOUNTING WITH ADHESIVE TAPE
1) With a nonabrasive solution, clean and dry the back of the
mounting bracket and the mounting surface to ensure a
secure hold. The mounting surface should be smooth and
flat.
2) Remove the protective strip from one side of the tape.
3) Adhere the tape to the designated area on the back of the
mounting bracket.
Problem: No reception of WWVB time signal.
Solution: 1) Wait overnight for signal.
2) Be sure Weather Station is at least 6 feet from any electrical devices, such as
televisions, computers, or other radio-controlled clocks.
3) Remove batteries for five minutes, reinsert and leave the unit alone overnight
without pressing buttons.
4) If there are still problems, contact La Crosse Technology
4) Remove the protective strip from the other side of the tape.
15
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Problem: Hour is incorrect (minute and date are correct)
Indoor Humidity checking interval:
Every 15 seconds.
Solution: Be sure correct time zone and daylight saving time settings are selected.
Outdoor Temperature checking interval Every 4 seconds
(Remote Temperature Sensor):
Problem: The LCD is faint
Solution: 1) Set the LCD contrast to a higher number
2) Replace batteries
Outdoor Temperature reception
(Weather Station):
Transmission Range:
Every 4 seconds.
330 feet (in open space).
Power Supply:
Weather Station:
Problem: No outdoor temperature is displayed.
Solution: 1) Remove all batteries, reinsert into sender first, then display.
2) Place remote sender closer to display.
2 x AA, IEC LR6, 1.5V.
2 x AA, IEC LR6, 1.5V.
Approximately 24 months.
Alkaline.
Remote Temperature Sensor:
Battery life cycle:
Recommended battery type:
Dimensions (L x W x H)
Weather Station (without stand):
3) Be sure all batteries are fresh.
4) Place Remote Control Sender and Weather Station in position so the straight-line
signal is not passing through more than two or three walls.
6.29“ x 3.62“ x 1.19“ (160 x 92 x 30.7 mm)
5.05” x 1.50” x 0.83” (128.3 x 38.2 x 21.2 mm)
Remote Temperature Sensor:
Problem: Temperatures do not match if units are placed next to each other.
Solution: Each temperature sensor is manufactured to be accurate to within 2ºF plus or minus
and under normal conditions, so two sensors could be as much as 4ºF different.
However, the difference can be exaggerated further because the sensors are
designed for different working environments. The indoor sensor is less responsive to
ambient air currents because of the shielding effect of the display's case. In addition,
the case can act as a heat sink to absorb and store heat from external sources (i.e.
handling of the case or radiant heat). Also, the much greater range of the outdoor
temperature sensor requires a different calibration curve than the indoor range. Error
is usually greater at the extreme ends of a range, making it harder to compare
different ranges with different curves. Under non-laboratory conditions, it is difficult to
compensate for the above factors and obtain an accurate comparison.
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against
manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on products
purchased and used in North America and only to the original purchaser of this product. To
receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem
determination and service procedures. Warranty service can only be performed by a La Crosse
Technology, Ltd authorized service center. The original dated bill of sale must be presented
upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s
authorized service center.
MAINTENANCE AND CARE INSTRUCTIONS
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as
stipulated herein, with new or reconditioned parts or products if found to be defective during the
limited warranty period specified above. All replaced parts and products become the property of
La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement
parts and products assume the remaining original warranty, or ninety (90) days, whichever is
longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs
covered by this warranty. If necessary repairs are not covered by this warranty, or if a product is
examined which is not in need or repair, you will be charged for the repairs or examination. The
owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service center. La Crosse Technology, Ltd
will pay ground return shipping charges to the owner of the product to a USA address only.
•
Extreme temperatures, vibration, and shock should be avoided to prevent
damage to the units.
•
Clean displays and units with a soft, damp cloth. Do not use solvents or scouring
agents; they may mark the displays and casings.
•
•
•
Do not submerge in water.
Immediately remove all low powered batteries to avoid leakage and damage.
Opening the casings invalidates the warranty. Do not try to repair the unit.
Contact La Crosse Technology for repairs.
SPECIFICATIONS
Temperature measuring range:
Indoor:
14.1°F to 139.8°F with 0.2°F resolution.
(-9.9°C to 59.8°C with 0.1°C resolution) “OFL”
displayed if outside this range.
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with
the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect
(including the lack of reasonable and necessary maintenance); (2) damage occurring during
shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any
accessory or decorative surface; (4) damage resulting from failure to follow instructions
contained in your owner’s manual; (5) damage resulting from the performance of repairs or
alterations by someone other than an authorized La Crosse Technology, Ltd authorized service
center; (6) units used for other than home use (7) applications and uses that this product was not
intended or (8) the products inability to receive a signal due to any source of interference.. This
warranty covers only actual defects within the product itself, and does not cover the cost of
Outdoor:
-39.8 °F to 139.8°F with 0.2°F resolution.
(-39.8°C to 59.8°C with 0.1°C resolution). “OFL”
displayed if outside this range.
Indoor relative humidity measuring
range:
1% to 99% with 1% resolution. (Display “- -“ if
temperature is OL.F; display “- -“ if < 1% and “99%”
if > 99%)
Indoor Temperature checking interval:
Every 10 seconds.
17
18
installation or removal from a fixed installation, normal set-up or adjustments, claims based on
misrepresentation by the seller or performance variations resulting from installation-related
circumstances.
Statement according to FCC part 15.21:
Modifications not expressly approved by this company could void the user's authority to operate
the equipment.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL,
CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE
OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE
USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS
NOT A TOY. KEEP OUT OF CHILDREN’S REACH.
Statement according to FCC part 15.105:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
This warranty gives you specific legal rights. You may also have other rights specific to your
State. Some States do no allow the exclusion of consequential or incidental damages therefore
the above exclusion of limitation may not apply to you.
For warranty work, technical support, or information contact:
•
•
•
Reorient or relocate the receiving antenna.
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help
e-mail:
(warranty work)
(information on other products)
web:
Questions? Instructions? Please visit:
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or
processed using electronic, mechanical or chemical procedures without written permission of the publisher.
This handbook may contain mistakes and printing errors. The information in this handbook is regularly
checked and corrections made in the next issue. We accept no liability for technical mistakes or printing
errors, or their consequences.
All trademarks and patents are acknowledged.
FCC ID: OMOTX29U (sensor)
RF Exposure mobile:
The internal / external antennas used for this mobile sensor must provide a separation distance
of at least 20 cm (8 inches) from all persons and must not be co-located or operating in
conjunction with any other antenna or sensor."
Statement according to FCC part 15.19:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
19
20
Download from Www.Somanuals.com. All Manuals Search And Download.
|