Table of Contents
Topic
PROFESSIONAL WEATHER CENTER
WS-1613-IT
PROFESSIONAL WEATHER CENTER
Instruction Manual
Page
3
Features
Operation Manual
Setting up
6
Congratulations on purchasing this state-of-the-art Professional Weather Center as an
example of excellent design and innovative technology. Featuring time, date,
calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature
and outdoor humidity, air pressure and various alarm settings for different weather
conditions, this Weather Center will provide you with extensive weather information
and forecast.
Function keys
12
14
16
24
25
31
32
36
37
37
39
46
48
49
53
54
56
LCD Screen
Manual Setting
Time alarm setting
Weather alarm operations
Hysteresis
INSTANT TRANSMISSION is the
state-of-the-art new wireless
This product offers:
Weather forecast and weather tendency
Wind direction and wind speed measurement
Rainfall measurement
Viewing history data
Viewing the min/ max weather data
Switch On/ Off buzzer
Outdoor transmission 915 MHz reception
Positioning
transmission technology, exclusively
designed and developed by LA
CROSSE TECHNOLOGY. INSTANT
TRANSMISSION offers you an
immediate update (every 4 seconds!)
of all your outdoor data measured
from the transmitters: follow your
climatic variations in real-time!
Care and Maintenance
Specification
IMPORTANT:
When a battery change is required on any of the units of this set, ALL units
have to be reset and user must go through initial set-up steps again.
Warranty Info
1
2
•
•
•
•
•
•
•
Low/High outdoor temperature and humidity alarm
Relative air pressure displayed in inHg or hPa
Air pressure tendency indicator for the past 12 hours (bargraph format)
LCD contrast selectable
Low battery indicator
Wind direction displayed in 16 steps
Wind Sensor
FEATURES:
•
•
Connected to the thermo-hygro sensor by cable
Can be installed onto a mast or a horizontal panel
Weather Center
Foldout stand
Hanging hole
Wind speed displayed in mph, km/h, or m/s, and Beaufort scale
LCD
Battery compartment
cover
•
Wind chill displayed in °F of °C
•
•
•
•
•
•
•
•
•
Max wind speed displayed with time & date of recording
High alarm function for wind speed
Manual reset of outdoor temperature/ humidity, pressure and wind chill data
Total rainfall displayed in mm or inch
Storm warning alarm
Buzzer on/off selectable
Storage of 200 sets of history weather data recorded in 3-hour intervals
Wireless transmission at 915 MHz
Transmission range up to 330 feet (100 meters)
Rain Sensor
•
•
Connected to the thermo-hygro sensor by cable
To be mounted onto a horizontal panel
Function keys
•
•
•
•
•
Time display (manual setting)
12/24 hour time display
Thermo-hygro Sensor
Calendar display (weekday, date, month, year)
•
Remote transmission of the outdoor temperature and humidity
to the Weather Center at 915 MHz
Time alarm function
Weather forecasting function with 3 weather icons and weather tendency
•
•
Weather-resistant casing
Wall mounting case (to be mounted in a sheltered place. Avoid
direct rain and sunshine)
indicator
•
•
•
Outdoor temperature display in ºF/°C
Outdoor Humidity display as RH%
MIN/MAX value of outdoor temperature and humidity display with time & date of
recording
3
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
The Bonus Receiver use 2 x AA, IEC LR6, 1.5V
batteries. When the batteries need to be replaced, the
low battery symbol will appear on the LCD.
To install and replace the batteries, please follow the
steps below:
•
•
•
Press to adjust (increase) the level of different settings
Stop the alarm during the time alarm or weather alarm ringing
Press to confirm to reset the max/min record
FUNCTION KEYS:
Weather Center:
The Weather Center has 5 easy-to-use function keys.
HISTORY key
•
•
•
Press to display the weather data history records
Stop the alarm during the time alarm or weather alarm ringing
Press to exit manual setting mode and alarm setting mode
1.
2.
Remove the battery compartment cover.
Insert the batteries observing the correct polarity
(see the marking in the battery compartment).
Replace the battery cover.
MIN/MAX key
Set key
3.
ALARM key
•
•
•
•
•
Press to enter the time alarm and weather alarm setting mode
Confirm particular alarm setting
Press to exit the manual setting mode
Stop the alarm during the time alarm or weather alarm ringing
Press to exit max/ min record display mode
BATTERY CHANGE:
It is recommended to replace the batteries in all units every 24 months to ensure
optimum accuracy of these units.
ALARM key
HISTORY key
+ key
SET key
•
Press to enter manual setting modes: LCD contrast, Manual time setting, 12/24
hour time display, Calendar setting, ºF/ºC temperature unit, Wind speed unit,
Rainfall unit, Pressure unit, Relative pressure reference setting, Weather
Tendency Sensitivity Value setting, Storm warning sensitivity setting and Storm
Alarm On/Off setting
In normal display mode, press and hold to switch on/off the Buzzer
In the weather alarm setting mode, press and hold to adjust different alarm
value and switch the alarm On/Off
Please participate in the preservation of the environment. Return
used batteries to an authorized depot.
MIN/MAX key
•
•
•
Press to display minimum and maximum records of various weather data
Press to adjust (decrease) the level of different settings
Stop the alarm during the time alarm or weather alarm ringing
Note:
The stored History record will not be kept after the battery change is done on the
Weather Center.
•
•
LCD SCREEN
IMPORTANT:
The LCD screen is split into 5 sections displaying the following information:
•
•
Press to activate the reset mode when max or min record is shown
Stop the alarm during the time alarm or weather alarm ringing
When a battery change is required on any of the units of this set, ALL units
have to be reset and user must go through initial set-up steps again. See
“Setting up” above.
1.
2.
3.
4.
5.
Time and date
Wind data
Outdoor temperature and humidity,
Air pressure and Rainfall data
Air pressure history and Weather forecast.
+ key
•
Press to change the calendar display to the preset alarm time, date, weekday +
date or seconds in the time display
12
13
14
MANUAL TIME SETTING:
You then may manually set the time of the clock by following the steps below:
MANUAL SETTING:
Low battery indicator
Time alarm icon
The following manual settings can be changed once the SET key is pressed:
Minutes flashing
•
•
•
•
•
•
•
•
•
•
•
•
LCD contrast setting
Manual time setting
12/24 hour time display
Calendar setting
°F/ °C temperature unit setting
Wind speed unit
Calendar display
Time display
Buzzer off indicator
Hour
flashing
Wind direction display
and wind speed in
Beaufort scale
1.
2.
3.
4.
5.
The hour digit will start flashing.
Use the + or MIN/MAX key to set the hour.
Press the SET key to switch to the minutes. The minute digit will start flashing.
Use the + or MIN/MAX key to set the minute.
Confirm the time with the SET key and enter the 12/24 HOUR TIME DISPLAY
SETTING.
Rainfall unit setting
Air pressure unit setting
Relative pressure reference value setting
Weather Tendency Sensitivity value
Storm warning threshold value
Alarm On/ Off setting
Wind speed Hi/ Lo
alarm icon
Wind speed in mph,
km/h or m/s
Wind Chill in °F or °
12/24 HOUR TIME DISPLAY SETTING:
LCD CONTRAST SETTING
Outdoor temperature
in °F or ºC
Outdoor relative
humidity in %
Outdoor temp.
alarm icon
Outdoor Humidity
alarm icon
Digit flashing
Digit flashing
Relative air pressure
display in inHg or hPa
Total rainfall in
inch or mm
The time can be set to view as 12-hour or 24-hour format. The default time display
mode is 12-h. To set to 24-h time display:
Weather tendency
indicator
The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD8" (default setting is
LCD 5):
1.
2.
Use the + or MIN/MAX key to toggle the value.
Confirm with the SET key and enter the CALENDAR SETTING.
Air pressure
histogram
Weather forecast icon
1.
2.
3.
Press the SET key, the contrast level digit will start flashing.
Use the + or MIN/MAX key to adjust the level of contrast.
Confirm with the SET key and enter the MANUAL TIME SETTING.
Transmitter signal
reception icon
TX
Transmitter low battery indicator
15
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
CALENDAR SETTING:
"Date. Month." (for 24h time display)
"Month. Date." (for 12h time display)
The temperature display can be selected to show temperature data in °F or °C.
(default °F)
RELATIVE AIR PRESSURE UNIT SETTING
1.
2.
3.
The temperature unit is flashing
Use the + or MIN/MAX key to toggle between “°F” or “°C”.
Confirm with the SET key and enter the WIND SPEED UNIT SETTING
Flashing
The relative air pressure can be set as inHg or hPa. The default unit is inHg.
1. Use the + or MIN/MAX key to toggle between the unit “inHg" or “hPa”
Year
WIND SPEED UNIT SETTING
2.Confirm the unit with the SET key and enter the RELATIVE PRESSURE
REFERENCE VALUE SETTING.
The date default of the Weather Center is 1. 1. of year 2005. The date can be set
manually by proceeding as follows.
Flashing
RELATIVE PRESSURE REFERENCE VALUE SETTING
1.
2.
The year digit starts flashing.
Use the + or MIN/MAX key to set the year. The range runs from "00" (2000) to
"99" (2099).
The wind speed unit can be set as mph (mile per hour), km/h (kilometer per hour), or
m/s (meter per second). The default unit is mph.
Note:
The default reference pressure value of the barometer is 29.91inHg when batteries
are first inserted. For an exact measurement, it is necessary to first adjust the
barometer to your local relative air pressure (related to elevation above sea
level). Ask for the current atmospheric pressure of your home area (Local weather
service, www, optician, calibrated instruments in public buildings, airport).
1.
2.
Use the + or MIN/MAX key to toggle between the unit “mph”, “km/h” or “m/s”
Confirm with the SET key and enter the RAINFALL UNIT SETTING.
3.
Press the SET key to confirm the year and enter the month setting. The month
digit will start flashing.
4.
5.
Use the + or MIN/MAX key to set the month.
Press the SET key to confirm the month and enter the date setting mode. The
date digit will start flashing.
RAINFALL UNIT SETTING
The relative air pressure can be manually set to another value within the range of
27.17 to 31.90 inHg (919 to 1080 hPa) for a better reference.
Flashing
The total rainfall unit can be set as inch or mm. The default unit is inch.
6.
7.
Use the + or MIN/MAX key to set the date.
Confirm all calendar settings with the SET key and enter the °F/°C
TEMPERATURE UNIT SETTING.
1.
2.
Use the + or MIN/MAX key to toggle between the unit “inch” or “mm”
Confirm the unit with the SET key and enter the RELATIVE AIR PRESSURE
UNIT SETTING
°C/ °F TEMPERATURE UNIT SETTING
Flashing
Flashing
18
19
20
1.
2.
The current relative pressure value will start flashing
1.
2.
3.
The sensitivity value will start flashing
Use the + or MIN/MAX key to increase or decrease the value. Continually
holding the key will allow the value to increase faster.
Confirm with the SET key and enter the WEATHER TENDENCY SENSITIVITY
VALUE SETTING.
Use the + or MIN/MAX key to select the value.
Confirm with the SET key and enter the STORM WARNING SENSITIVITY
SETTING.
Flashing
3.
STORM WARNING THRESHOLD VALUE SETTING
You may also define a switching sensitivity value for the Storm warning display at a
decrease of air pressure from .09 inHg to .27 inHg over 6 hours (Default 0.15 inHg).
Note:
Note:
This feature is useful for those who live at elevations above sea level, but want their
air pressure display to be based on sea level elevation.
In case a storm warning alarm is activated, the downward weather tendency arrow will
be flashing. (Also see WEATHER TENDENCY INDICATOR below)
WEATHER TENDENCY SENSITIVITY LEVEL SETTING
TO EXIT THE MANUAL SETTING MODE
To exit the manual setting anytime during the manual setting modes, press the
ALARM key (or HISTORY key) or wait for the automatic timeout. The mode will return
to the normal time display.
Flashing
Flashing
TIME ALARM SETTING
The alarm time can be set by the use of the ALARM and SET key.
1.
Press the ALARM key once. The “ALARM” icon and time digits are shown at the
top right of the LCD.
1.
2.
3.
The sensitivity value will start flashing.
Use the + or MIN/MAX key to select the value.
Confirm with the SET key and enter the STORM ALARM ON/OFF SETTING.
STORM ALARM ON/ OFF SETTING
You may also choose to switch On or Off the acoustic Storm warning alarm (Default
OFF).
Alarm time
digit
You may select a definite switching sensitivity value, .06, .09, or .12 inHg for the
change in the display of weather icons. This represents the "sensitivity" of the weather
forecast (the smaller the value selected, the more sensitive the weather forecast).
The default value is 0.09 inHg.
1.
2.
3.
The digit "AOF" will start flashing.
Use the + key to switch On or Off the alarm. ("AOF" = OFF; "AON" = On)
Confirm with the SET key and the normal display mode will be shown.
Alarm-On icon
21
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
Press and hold the SET key for about 2 seconds. The hour digit of the alarm
time will start flashing. Press the + or MIN/MAX key to set the hour of the alarm
time.
Press the SET key to confirm and advance to the minute setting. The minute
digit will be flashing.
Press the + or MIN/MAX key to set the minute of the alarm time. Press the
ALARM key to confirm. Wait for about 30 seconds and the display will return to
normal display mode automatically.
In the normal display mode, press the ALARM once key to go to the time alarm
setting mode again. Then press shortly the SET key to switch on or off the time
alarm. (The showing of the icon (((y))) means that the time alarm is switched on.)
Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
Default alarm values:
Low
32°F (0°C)
104°F (40°C)
45%
Temperature
High
Low
High
High
3.
4.
Relative
Humidity
Wind speed
70%
62.0mph (100km/h)
High wind
speed Alarm-
On icon
HIGH AND LOW OUTDOOR TEMPERATURE ALARM SETTING
5.
Note:
Outdoor temp
Alarm-On icon
Outdoor humidity
Alarm-On icon
The High and Low outdoor temperature alarm can be set On/Off independently,
according to your needs.
6.
Set the Outdoor temperature alarm value (High or Low alarm value) :
Note:
1.
In the normal display mode, press the ALARM key twice. The High Outdoor
The alarm ringing duration is 2 minutes. To stop the alarm, press any key during the
alarm ringing.
Temperature alarm display will be shown.
WEATHER ALARM OPERATIONS
The Weather Center can be set to alert when a specific weather condition is reached.
High alarm icon
The Weather alarms can be set when certain weather conditions are met according to
your requirements. For example, you can set the thresholds for the outdoor
temperature to +104°F (+40°C) (high) and 14°F (-10°C) (low), while only enabling the
high alarm and disabling the low alarm (i.e. temperatures <14°F (-10°C) won’t trigger
alarm, but temperatures >+104°F (+40°C) will).
The following Weather Alarm settings can be adjusted in the ALARM setting
mode.
•
•
•
•
•
High outdoor temperature alarm
Low outdoor temperature alarm
High outdoor humidity alarm
Low outdoor humidity alarm
High wind speed alarm
Alarm-On icon
2.
Press and hold the SET key for about 2 seconds. The temperature digit will start
flashing. Press the + or MIN/MAX key to set the high outdoor temp alarm value.
(Keep holding the key will allow the value to increase faster.)
24
25
26
3.
Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
Set the Outdoor temperature alarm value (High or Low alarm value):
WIND SPEED ALARM SETTING
The High wind speed alarm can be set by following the steps below.
1.
In the normal display mode, press the ALARM key 4 times. The High Outdoor
Humidity alarm display will be shown.
1.
In the normal display mode, press the ALARM key six times. The High wind
4.
5.
Press the ALARM key once. The Low Outdoor Temperature alarm display will
be shown.
speed alarm display will be shown.
Press and hold the SET key for about 2 seconds. The temperature digit will start
flashing. Press the + or MIN/MAX key to set the low outdoor temp alarm value.
(Keep holding the key will allow the value to increase faster.)
Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
6.
7.
2.
3.
Press and hold the SET key for about 2 seconds. The humidity digit will start
flashing. Press the + or MIN/MAX key to set the high outdoor humidity alarm
value.
Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
Press the ALARM key once. The Low Outdoor humidity alarm display will be
shown.
Press and hold the SET key for about 2 seconds. The humidity digit will start
flashing. Press the + or MIN/MAX key to set the low outdoor humidity alarm
value.
Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
2.
3.
Press and hold the SET key for about 2 seconds. The wind speed digit will start
flashing. Press the + or MIN/MAX key to set the high wind speed alarm value.
Press the ALARM key to confirm the setting. The digit will stop flashing. Press
the SET key to switch on or off the alarm. (The showing of the icon (((y))) means
that the alarm is switched on.)
Press the HISTORY key or wait for about 30 seconds and the display will return
to normal display mode automatically.
In case the temperature value meets the condition for high alarm or low alarm, the
value will be blinking, along with the corresponding icon ("HI AL"/ "LO AL").
And the buzzer will ring for 2 minutes. User then may press any key to stop the ring.
User may quit the alarm setting and return to the normal display mode by pressing the
HISTORY key.
4.
5.
4.
Press the ALARM key once to return to the normal display mode.
In case the wind speed exceeds the condition for high wind speed alarm, the value
will be flashing, along with the corresponding high alarm icon ("HI AL"). And the
buzzer will ring for 2 minutes. User may press any key to stop the sound.
6.
7.
HIGH AND LOW OUTDOOR HUMIDITY ALARM SETTING
Note:
HYSTERESIS
The High and Low outdoor humidity alarm can be set On/Off independently according
to your needs.
To compensate for fluctuation of the measured data, which may cause the weather
alarm to sound constantly if the measured reading is close to your set level, a
hysteresis function has been implemented for each weather alarm. For example, if the
high temperature alarm is set to +77°F (25°C) and the current value moves to +77°F
(25°C), the alarm will be activated (if it has been enabled). Now when the temperature
In case the humidity value meets the condition for high alarm or low alarm, the value
will be blinking, along with the corresponding icon ("HI AL"/ "LO AL"). And the buzzer
will ring for 2 minutes. User may press any key to stop the sound.
27
28
29
Download from Www.Somanuals.com. All Manuals Search And Download.
For every sudden or significant change in the air pressure, the weather icons will
update accordingly to represent the change in weather.
Common to weather forecasting, absolute accuracy cannot be guaranteed. The
weather forecasting feature is estimated to have an accuracy level of about 75% due
to the varying areas the Weather Center has been designed for use. In areas that
experience sudden changes in weather (for example from sunny to rain), the Weather
Center will be more accurate compared to use in areas where the weather is stagnant
most of the time (for example mostly sunny).
If the Weather Center is moved to another location significantly higher or lower than
its initial standing point (for example from the ground floor to the upper floors of a
house), discard the weather forecast for the next 48-60 hours, as the Weather Center
may mistake the new location as being a possible change in air-pressure when really
it is due to the slight change of altitude.
drops to +76.8°F (24.9°C) or below and thereafter again increases to beyond +77°F
(25°C), the data will be blinking, but no alarm will be activated. It has to drop to below
+75.2°F (24°C) (with a pre-set hysteresis of 1.8°F (1°C)) so that the alarm can be
produced again. Hysteresis values for the various weather data types are given in the
following table:
(Every time a new average pressure value has been obtained (once per minute), this
value is compared with an internal reference value. If the difference between these
values is bigger than the selected weather tendency sensitivity, the weather-icon
changes, either for worse or for better. In this case, the current pressure value
becomes the new weather tendency reference.)
Weather data
Temperature
Humidity
Hysteresis
1.8°F (1°C)
3% RH
If the icons do not change, either the air pressure has not changed or the change has
been too small for the Weather Center to register. So you may adjust the "sensitivity"
of the pressure change checking in the setting mode –see WEATHER TENDENCY
SENSITIVITY VALUE SETTING above.
Wind speed
3.1 mph
Note:
The temperature or humidity data will keep on flashing even after a key has been
pressed to stop the alarm or buzzer has been switched off, to indicate that the current
weather condition is out of the pre-set limit(s)
WEATHER TENDENCY INDICATOR
However, if the icon displayed is a sun or raining cloud, there will be no change of
icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since
the icons are already at their extremes.
The icons displayed forecasts the weather in terms of getting better or worse and not
necessarily sunny or rainy as each icon indicates. For example, if the current weather
is cloudy and the rainy icon is displayed, it does not mean that the product is faulty
because it is not raining. It simply means that the air pressure has dropped and the
weather is expected to get worse but not necessarily rainy.
Working together with the weather icons is the weather tendency indicators (arrow
located on the left and right sides of the weather icons). When the indicator points
upwards, it means that the air-pressure is increasing and the weather is expected to
improve, but when indicator points downwards, the air-pressure is dropping and the
weather is expected to become worse.
WEATHER FORECAST AND WEATHER TENDENCY
WEATHER FORECASTING ICONS:
Weather forecasting icons is displayed in any of the following combinations at the
right bottom part of LCD:
Taking this into account, one can see how the weather has changed and is expected
to change. For example, if the indicator is pointing downwards together with cloud and
sun icons, then the last noticeable change in the weather was when it was sunny (the
sun icon only). Therefore, the next change in the weather will be cloud with rain icons
since the indicator is pointing downwards.
TENDENCY
TENDENCY
TENDENCY
Note:
After setting up, readings for weather forecasts should be disregarded for the next 12-
24 hours. This will allow sufficient time for the Weather station to collect air pressure
data at a constant altitude and therefore result in a more accurate forecast.
Note:
Cloudy with sunny
intervals
Sunny
Rainy
Once the weather tendency indicator has registered a change in air pressure, it will
remain permanently visualized on the LCD.
30
31
32
AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC
PRESSURE TREND)
The bottom section of the LCD also shows the relative air pressure value and the air
pressure history.
drop of the air pressure and the weather is expected to get worse from the present
time "0".
At every full hour the current air pressure is used as a basis for the display of a new
graph bar. The existing graph is then moved one column to the left.
RAINFALL MEASUREMENT
The total rainfall measurement is displayed in the fourth section of the LCD, in the unit
of mm or inch. (see VIEWING THE MIN/MAX WEATHER DATA below)
Depending on programming conditions, display of the history of air pressure in form of
a graph consisting of vertical bars.
The bar graph of the electronic barometer shows the air pressure history of the past
12 hours in five 3-hour steps.
Note:
For accurate barometric pressure trend, the Weather Center should operate at the
same altitude. For example, it should not be moved. Should the unit be moved, for
instance from the ground to the second floor of the house, the readings for the next
12-24 hours shall be discarded.
VIEWING THE HISTORY DATA
The Weather Center can store up to 200 sets of weather data which are recorded
automatically at 3-hour intervals after the weather station is powered up, at the
nearest time of 0:00, 03:00, 06:00, 09:00, 12:00, 15:00, 18:00 and 21:00. For
instance, if user has manually set the time as 14:52 after installing batteries, the first
history record will be made at the coming 15:00 automatically. Then the second
record will be on 18:00 and so on.
Each weather record includes the Wind direction, Wind speed in Beaufort scale, Wind
chill temperature, wind speed, Outdoor temperature and humidity, relative pressure
and total rainfall, pressure history and weather tendency. Also, the time and date of
recording will be displayed.
WIND DIRECTION AND WIND SPEED MEASUREMENT
In normal display mode, the second section of the LCD shows the following wind data.
•
Wind direction (shown on the a compass scale of 16 divisions) and wind speed
Air pressure
changes in inHg
Air pressure
changes in hPa
in Beaufort scale
•
•
Wind chill in °F or °C
Wind Speed in mph, km/h or m/s
The horizontal axis represents the last 12 hours air pressure recording (-12, -9, -6, -3
and 0 hour). The bars are plotted at each of the 5 steps and give the trend over the
recorded period. The scale on the right compares the result. The "0" in the middle of
this scale determines the current air pressure.
Text showing wind speed
in Beaufort scale
Pointer indicates the
currently detected wind
direction
Note:
The vertical axis represents the air pressure changes in inHg (+0.12, +0.06, 0, -0.06, -
0.12. The “0” represents the current air pressure). The newly measured pressure was
compared to the previously recorded pressure reading. The pressure change
is expressed by the difference between the current ("0h") and the past readings in
division of ±2 hPa or ±0.06 inHg. If the bars are rising it indicates that the weather is
getting better due to an increase in air pressure. If the bars go down it indicates a
In order to acquire the correct time of recording of the history records, you shall
manually set the current time as soon as installing batteries to the Weather Center.
Afterwards, you should avoid changing the pre-set time as it will also alter the
recorded "time of recording" of each history record, which may lead to confusion.
This alarm symbol
indicates that the alarm
is set On
Wind speed
Wind chill
33
34
35
Download from Www.Somanuals.com. All Manuals Search And Download.
To view the weather history:
•
The total rainfall value will be exhibited in whole number (no decimal place) in
the history record.
2.
3.
4.
Max outdoor temperature with the date and time of recording
Min outdoor humidity with the date and time of recording
Max outdoor humidity with the date and time of recording
1.
Press the HISTORY key. The latest weather record will be shown with the date
and time of recording. The "HISTORY" icon will be displayed at the bottom of
the LCD.
VIEWING THE MIN/MAX WEATHER DATA
The Weather Center will record the maximum and minimum value of the various
weather data with time and date of recording automatically. The following stored
MIN/MAX weather data can be viewed by pressing the MIN/MAX key in normal
display mode.
Time and date
or recording
1.
Min outdoor temperature with the date and time of recording
Time and date
or recording
MAX outdoor
humidity value
MIN outdoor
temperature
value
HISTORY icon
2.
Press MIN/ MAX to view older records.
(Press MIN/MAX and + key to view "Previous" and "Next" record respectively.
The records are made at 3-hour intervals)
MAX icon
Note:
•
The stored history records will not be retained after battery change or whenever
battery is removed.
MIN icon
36
37
38
5.
Min Wind chill temperature with the date and time of recording
7.
8.
Min Relative pressure with the date and time of recording
Max Relative pressure with the date and time of recording
9.
Maximum wind speed
Time and date
or recording
Time and date
or recording
Time and date
or recording
MAX wind
speed value
MIN wind chill
value
MAX relative
pressure value
MAX icon
MIN icon
RESET THE MIN/MAX WEATHER DATA
To reset the aforementioned MIN/MAX weather data 1. to 9., you shall need to reset
each of the data independently.
MAX icon
6.
Max Wind chill temperature with the date and time of recording
1.
Press MIN/MAX key to show the desired weather data. For instance, if you want
to reset the minimum humidity, in the normal display you shall press the
MIN/MAX key 3 times to show the min humidity value.
39
40
41
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
3.
Press and hold the SET key for about 2 seconds, then the "RESET" icon will
appear at the bottom part of the LCD.
Press the + key once, then the stored value will be reset to the current value
and current time.
To reset the rainfall reading, press the + key once when the Rainfall value and
"Reset" icon is shown. Then the total rainfall amount will be reset to 0, and the time
updated to current time.
To re-enable the buzzer:
1.
When the BUZZER OFF icon is shown on LCD, press the SET key shortly and
the BUZZER OFF icon will disappear.
2.
Press ALARM key once to return to the normal display mode. The "BUZZER
OFF" icon will no longer be shown. Then the alarm will sound normally.
Note:
4.
Press the ALARM key to return to normal display mode.
After power up, the time and date and total rainfall is displayed as "- - -". After time is
adjusted manually, the set time will be shown.
10.
Total rainfall amount
LOW BATTERY INDICATOR
The total rainfall measurement is displayed in the fourth section of the LCD, in the unit
of mm or inch. It shows the total rainfall accumulated since last reset of the Weather
Center.
In normal display mode, press the MIN/MAX key 10 times to show the total rainfall
value. The "RESET" icon will also be shown at the same time.
The low battery indicator of the Weather Center and the Thermo-hygro sensor will be
displayed at the top and bottom portion of the LCD respectively when the battery
power is low. It is recommended to replace the batteries in all units on an annual
basis to ensure optimum accuracy of the system.
SWITCHING ON/OFF THE BUZZER
User may choose to turn off the buzzer so that when the time alarm is switched on
and activated, the buzzer will not sound but we can still see the alarm icon (((y)))
flashing on the LCD for time alarm.
Note:
On the other hand, when the buzzer is turned off and any weather alarm is activated,
the particular weather digits will flash to show user that the weather condition is being
out of the preset threshold value, yet the buzzer will not sound.
•
After battery change, both the Weather Center and the Thermo-hygro sensor
need to be reset (see note ”Setting up”)
The total rainfall value is counted
from this time and date
•
The History data record will be clear after the battery change.
To switch off the buzzer:
1.
In normal display mode, press and hold the SET key until the icon "BUZZER
OFF" is shown at the right side above the Wind direction scale. The LCD will
change to setting mode.
Press ALARM key once to return to the normal display mode. The "BUZZER
OFF" icon will still be shown.
OUTDOOR TRANSMITTER 915 MHz RECEPTION
The outdoor temperature, humidity, wind data and rainfall are transmitted from the
Thermo-hygro sensor every 4.5 seconds. The Weather Center will then be
synchronized to the Thermo-hygro sensor to receiver outdoor data. The transmission
range (up to 330 feet) of the Outdoor Thermo-hygro sensor may be affected by the
ambient temperature. At cold temperatures the transmitting distance may be
decreased. Please keep this in mind when placing the transmitter.
If the outdoor data are not being received within 30 seconds after setting up (or the
outdoor display shows “- - -“ in the outdoor section of the Weather Center after
consecutive failed attempts during normal operation). Please check the following
points:
2.
Total rainfall
value
BUZZER OFF icon
42
43
44
1.
2.
3.
The distance of the Weather Center or transmitter should be at least 5 to 6.5
feet away from any interfering sources such as computer monitors or TV sets.
Avoid positioning the Weather Center onto or in the immediate proximity of
metal doors or window frames.
Using other electrical products such as headphones, speakers, or cordless
phones operating on the same signal frequency (915 MHz) may prevent correct
signal transmission and reception.
Neighbors using electrical devices operating on the 915 MHz signal frequency
can also cause interference.
“Visibility” of Weather Center and Thermo-hygro sensor (e.g. through a window)
increases the range.
•
•
Cable lengths of the units meet with your distance requirements at the point of
fixing
Signals from the sensors can be received by the base station at points of
mounting
An ideal mounting place for the Thermo-hygro sensor would be the outer wall beneath
the extension of a roof, as this will protect the sensor from direct sunlight and other
extreme weather conditions.
To wall mount, use the 2 screws to affix the wall bracket to the desired wall, plug in
the Thermo-hygro sensor to the bracket and secure both parts by the use of the
supplied screw and ensure that the cables from the wind and rain sensors are
correctly plugged in otherwise data transmission errors could occur.
Weather Center
The Weather Center has been designed to be hung onto wall or free standing with the
foldout stand.
4.
5.
To wall mount
Choose a sheltered place, such as under the eve of a roof.
Avoid direct rain and sunshine.
Wind Sensor
Wind vane
Before wall mounting, please check that the outdoor
temperature and humidity values can be received from the
desired locations. To wall mount:
Note:
Vertical
mast
When the 915 MHz signal is received, do not re-open the battery compartment cover
of either the transmitter or Weather Center, as the batteries may spring free from the
contacts and force a false reset. Should this happen accidentally then reset all units
(see Setting up above) otherwise transmission problems may occur.
1.
Fix a screw (not supplied) into the desired wall, leaving
the head extended out the by about 5mm.
2.
Hang the Center onto the screw. Remember to ensure
that it locks into place before releasing.
During normal operation, after the outdoor display shows "- - -", the weather station
will change to receive the outdoor data every 15 minutes, until the data is read. Then
the reception period will return to 4.5 seconds.
Wind fan
Thermo-hygro Sensor
If no reception is possible despite the observation of these factors, all system units
have to be reset (see Setting up).
Rain Cover
Main Unit
Horizontal panel
POSITIONING
Firstly, check that the wind-fan and the wind-vane can rotate freely before fixing the
unit. For correct and accurate readings it is important to mount the sensor so that the
front (marked E) is pointing in East-West direction. The wind sensor should now be
Prior to permanently affixing any of the units, please ensure the following points are
considered:
Wall Bracket
46
45
47
Download from Www.Somanuals.com. All Manuals Search And Download.
mounted using the screw or cable tie provided onto a solid wall/ panel mast or mast to
allow the wind to travel around the sensor unhindered from all directions (ideal mast
size should be from diameter about 5/8” (16 mm) to 11/4” (33 mm)).
Once the wind sensor is fixed onto the mast, connect the cable to the corresponding
thermo-hygro sensor socket so that operating power supply can be received and data
can be transmitted to the base station.
The rain sensor is now operable. For testing purposes, very slowly pour a small
amount of clean water into the rain sensor funnel. The water will act as rainfall and will
be received and displayed at the base station after about 2 minutes delay i.e. when
the reading interval is reached.
•
•
Low battery indicator
Table standing or wall mountable (foldout table stand)
FUNCTION KEYS:
Bonus Receiver:
The Bonus Receiver features only two easy-to-use function keys.
BONUS RECEIVER FUNCTIONS AND SETTINGS
FEATURES:
Rain Sensor
Hanging
Hole
min/ max/ + key
Set/ ch key
LCD
Display
Battery
compartment
cover
Set/ch key (Setting/Channel)
•
Press and hold for about 3 seconds to enter the Manual Setting mode.
Horizontal panel
Function
Keys
Foldout stand
Min/max/+ key (Min/ Max temperature)
For best results, the rain sensor should be securely mounted onto a horizontal surface
about 2-3ft (60-90cm) above the ground and in an open area away from trees or other
coverings where rainfall may be reduced causing inaccurate readings.
•
Used to toggle between the minimum and maximum recorded readings of
indoor & outdoor temperature and outdoor humidity.
•
•
Quartz clock in 12 or 24-hour time display
Indoor and outdoor temperature reading in degrees Celsius (°C) or Fahrenheit
(°F)
Outdoor humidity reading in %RH
Minimum and Maximum records of indoor temperature, outdoor temperature
and outdoor humidity
When securing into place, check that rain excess will not collect and store at the base
of the unit but can flow out between the base and the mounting surface (test by
pouring clean water).
•
•
After mounting the rain sensor, connect the cable to the thermo-hygro sensor at the
corresponding socket so power supply can be received and data be transmitted to the
base station
•
•
Wireless transmission at 915 MHz
Outdoor data checking interval at every 4.5 seconds
48
49
50
Note:
LCD SCREEN AND SETTINGS:
When the time display is set as 12-hour mode, the temperature unit will be fixed
to °F; when the time mode is 24-hour, the temperature unit will be fixed to °C.
Time
1.
In normal display mode, press and hold the set/ch key for about 3 seconds. The
"12h" or "24h" digit will be flashing.
2.
3.
Press the min/max/+ key to set the desired time display mode.
Press shortly the set/ch key to enter the MANUAL TIME SETTING.
Indoor
Temperature in °C/°F
Outdoor
Temperature in
MANUAL TIME SETTING
The time can be manually set. Please follow the steps below:
Minimum icon
°C/ °F
Outdoor humidity
1.
2.
The hour digit of the time display will be flashing.
Press the min/max/+ key to set the hour. Press the set/ch key to confirm and
Outdoor Reception
%RH
2.
Press the min/max/+ key once more to view the maximum indoor temperature,
Signal icon*
maximum outdoor temperature and maximum outdoor humidity.
proceed to the minute setting.
3.
The minute digit will be flashing. Press the min/max/+ key to adjust the minute.
Press the set/ch key once more to return to normal display.
Transmitter Low battery indicator
Receiver Low battery indicator
RESETTING THE MINIMUM AND MAXIMUM READINGS:
To reset the minimum and maximum temperature and humidity data to the current
value, follow the step below:
* When the signal is successfully received by the Bonus Receiver, the outdoor
reception icon will be switched on. (If not successful, the icon will not be shown on the
LCD) So the user can easily see whether the last reception was successful (icon on)
or not (icon off). On the other hand, the short blinking of the icon shows that a
reception - is being done currently.
VIEWING THE MINIMUM AND MAXIMUM READINGS:
The minimum and maximum temperature and humidity data records of the indoor or
outdoor channels can be view by following the steps below:
1.
2.
Press the min/max/+ key to display the minimum values.
Press and hold the min/max/+ key for about 3 seconds to reset all the
minimum/ maximum indoor and outdoor data to the current values in a single
action.
1.
Press the min/max/+ key once to view the minimum indoor temperature,
minimum outdoor temperature and minimum outdoor humidity.
MANUAL SETTINGS:
POSITIONING THE BONUS RECIVER:
The Bonus Receiver comes with a foldout table stand, which provides the option of
table standing or wall mounting the unit. Before wall mounting, please check that the
outdoor temperature and humidity values can be received from the desired locations.
12 / 24- HOUR TIME DISPLAY SETTING AND TEMPERATURE UNIT (°C/°F)
SETTING
The Bonus Receiver can be set to display time in 12-hour or 24-hour mode. Default
setting 12h display mode and temperature display in degree Fahrenheit:
51
52
53
Download from Www.Somanuals.com. All Manuals Search And Download.
To wall mount:
Wind sensor
Rain sensor
:
:
9.84" x 6.45" x 7.58" (250 x 164 x 192.7 mm)
5.67" x 2.15" x 3.46" (144 x 54.6 x 88 mm)
SPECIFICATIONS:
1.
Fix a screw (not supplied) into the desired wall, leaving
WEATHER CENTER:
Temperature measuring range:
the head extended out the by about 5mm.
BONUS RECEIVER:
Temperature measuring range
2.
Hang the Bonus Receiver onto the screw. Remember to
ensure that it locks into place before releasing.
Outdoor
:
-40°F to +139.8°F with 0.2°F resolution
-40ºC to +59.9ºC with 0.1ºC resolution
(“OF.L” displayed if outside this range)
Indoor
:
14.1°F to +139.8°F with 0.2°F resolution
-9.9ºC to +59.9ºC with 0.1ºC resolution
(“OFL” displayed if outside this range)
-39.8°F to +139.8°F with 0.2°F resolution
-39.9ºC to +59.9ºC with 0.1ºC resolution
(“OFL” displayed if outside this range)
Relative humidity measuring range:
Outdoor
:
1% to 99% with 1% resolution
Outdoor
:
(“- -” displayed if < 1%, "99" displayed if ≥ 99%)
Wind speed
Wind chill
:
0 to 111.8 mph (0 to 50 m/s)
(displayed "OF.L" when > 50m/s)
-40°F to +139.8°F (-40ºC to +59.9ºC)
(displayed "OF.L" if outside this)
27.17 to 31.90 inHg (919 to 1080 hPa)
0" to 393.6" (0 to 9999 mm) (displayed
"OF.L" when > 9999mm)
every 4.5 seconds
every 15 seconds
up to 330 feet (100meters) in open space
Outdoor Humidity measurement :
1 to 99% (Displays "1%" when ≤1%; displays
"99%" when ≥ 99%)
CARE AND MAINTENANCE:
:
•
Extreme temperatures, vibration and shock should be avoided as these may
cause damage to the units and give inaccurate forecasts and readings.
When cleaning the display and casings, use a soft damp cloth only. Do not use
solvents or scouring agents as they may mark the LCD and casings.
Do not submerge the units in water.
Indoor temperature checking interval
Outdoor data checking interval
Power consumption
Bonus Receiver
Battery life cycle
:
:
every 15-seconds
every 4.5-seconds
Relative pressure pre-set range
Rainfall
:
:
•
:
2 x AA, IEC LR6, 1.5V
approximately 24 months (Alkaline batteries recommended)
•
•
Outdoor data reception
Air pressure checking interval
Transmission range
Power consumption:
Weather Center
:
:
:
:
Immediately remove all low powered batteries to avoid leakage and damage.
Replace only with new batteries of the recommended type.
Do make any repair attempts to the units. Return it to their original point of
purchase for repair by a qualified engineer. Opening and tampering with the
units may invalidate their guarantee.
Do not expose the units to extreme and sudden temperature changes, this may
lead to rapid changes in forecasts and readings and thereby reduce their
accuracy.
Dimensions (L x W x H)
Bonus Receiver
:
2.76” x 1.14” x 4.54” (70 x 29 x 115.2mm)
•
•
:
:
3 x AA, IEC LR6, 1.5V
2 x AA, IEC LR6, 1.5V
LIABILITY DISCLAIMER
Thermo-hygro sensor
•
•
The electrical and electronic wastes contain hazardous substances. Disposal of
electronic waste in wild country and/or in unauthorized grounds strongly
damages the environment.
Please contact your local or/and regional authorities to retrieve the addresses of
legal dumping grounds with selective collection.
Battery life
:
approximately 24 months (Alkaline batteries recommended)
Dimensions (L x W x H)
Weather Station
Thermo-hygro transmitter
:
:
6.51" x 1.21" x 5.58" (165.4 x 30.8 x 141.9 mm)
2.25" x 2.44" x 6.18" (57.3 x 62 x 157 mm)
54
55
56
e-mail:
•
All electronic instruments must from now on be recycled. User shall take an
active part in the reuse, recycling and recovery of the electrical and electronic
waste.
(warranty work)
•
•
The unrestricted disposal of electronic waste may do harm on public health and
the quality of environment.
As stated on the gift box and labeled on the product, reading the “User manual”
is highly recommended for the benefit of the user. This product must however
not be thrown in general rubbish collection points.
The manufacturer and supplier cannot accept any responsibility for any incorrect
readings and any consequences that occur should an inaccurate reading take
place.
This product is designed for use in the home only as indication of the
temperature.
(information on other products)
web:
For more information, please visit:
•
•
•
•
•
•
This product is not to be used for medical purposes or for public information.
The specifications of this product may change without prior notice.
This product is not a toy. Keep out of the reach of children.
No part of this manual may be reproduced without written authorization of the
manufacturer.
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or
duplicated or processed using electronic, mechanical or chemical procedures without written
permission of the publisher.
WARRANTY
For warranty work, technical support, or information contact:
This handbook may contain mistakes and printing errors. The information in this handbook
is regularly checked and corrections made in the next issue. We accept no liability for
technical mistakes or printing errors, or their consequences.
La Crosse Technology, Ltd
2809 Losey Blvd. South
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
Springfield / Lacrosse Canada.
1-800-661-6721
5151 Thimens Rd.
Montreal, Quebec
H4R 2C8
All trademarks and patents are acknowledged.
57
58
Download from Www.Somanuals.com. All Manuals Search And Download.
|