La Crosse Technology Computer Monitor WS 7038U User Manual

WS-7038U  
Wireless 433 MHz  
Miniature Rain Monitor  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INVENTORY OF CONTENTS  
1) WS-7038U—Wireless Rain Monitor with table stand. (Figure 1).  
2) TX5U—Wireless Rainfall Transmitter: includes a base, rainfall collector,  
and two mounting screws. (Figure 2).  
3) Instruction manual and warranty card.  
Figure 1  
Figure 2  
Function  
Buttons  
ADDITIONAL EQUIPMENT (not included)  
1) Two fresh 1.5V AAA batteries.  
2) Two fresh 1.5V AA batteries.  
3) Flathead screwdriver.  
QUICK SET-UP GUIDE  
1) Insert two AA batteries into the Rainfall Transmitter.  
2) Insert two AAA batteries into the Rain Monitor.  
3) Program settings.  
4) Wait 15 minutes, or until the Rain Monitor has received signals from the  
Rainfall Transmitter.  
5) Mount the units, ensuring they are sending and receiving signals.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DETAILED SET-UP GUIDE  
I) BATTERY INSTALLATION  
Note: Batteries will fit tightly. To avoid start-up problems make sure that the  
batteries do not spring free.  
Battery compartment  
Battery cover  
A) RAINFALL TRANSMITTER  
1. Remove the flat-head screw and  
battery cover, located on the  
underside of the base.  
2. Observe the correct polarity,  
and install two AA batteries.  
3. Make sure the rubber weather  
seal is in place and replace  
the battery cover and screw.  
4. Separate the base by turning  
the rainfall collector in a  
counter-clockwise direction.  
Remove the tape from the  
teeter-totter. Replace the  
cover.  
Teeter-  
Totter  
B. RAIN MONITOR  
1. Remove the battery cover on the backside of the unit.  
2. Observe the correct polarity, and install 2 AAA batteries.  
3. Replace the battery cover.  
Note: After the batteries have  
been installed, the entire LCD  
(Liquid Crystal Display) will  
light up briefly, then the default  
settings will be initiated.  
Battery  
Compartment  
Battery Cover  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROGRAM MODE  
After the batteries have been installed the minute digits of the time display will flash,  
signaling that the program mode has been automatically entered. If no buttons are  
pressed, the digits will stop flashing after 50 seconds. To enter the programming mode  
(when not automatically entered) hold down the RAIN/SET button for 2 seconds—the  
minute digits will flash. The Program Mode is laid out in a manner that allows you to  
program each function separately, or you can follow the instructions entirely to program  
the Rain Monitor. Complete programming is usually done for the initial set-up, and will  
require you to skip step 1 of programming sections II through VI.  
I) FUNCTION BUTTONS  
There are 2 function buttons located on the front of the Rain Monitor, and under the  
LCD screen. The function buttons are labeled: RAIN/SET, and HISTORY/+. See  
Figure 1.  
II) TIME SETTING  
1) Hold down the RAIN/SET button for 2 seconds, or until the minute-digits  
flash.  
2) Press the HISTORY/+ button to adjust the minutes.  
3) Press the RAIN/SET button to confirm the minutes and to shift to set the  
hour.  
4) The hour-digits should now be flashing. Press the HISTORY/+ button to  
adjust the hour.  
Note: An “A” (a.m.) or a “P” (p.m.) will appear to the right of the time  
display, set the time accordingly.  
5) Press the RAIN/SET button to confirm the hour setting, and to advance to  
set the date.  
III) DATE SETTING  
1) Hold down the RAIN/SET button for 2 seconds, press the RAIN/SET button  
2 more times—until the first digit of the date (the month) flashes (default is  
“1.1”).  
2) Press the HISTORY/+ button to adjust the month.  
3) Press the RAIN/SET button to confirm the month, and to shift to set the date.  
4) Press the HISTORY/+ button to adjust the date.  
5) Press the RAIN/SET button to confirm the date, and to advance to set the  
weekday.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV) WEEKDAY SETTING  
Note: The weekday is not represented alphabetically, it is represented numerically,  
with “1” equal to Monday, and “2” equal to Tuesday, etc.  
1) Hold down the RAIN/SET button for 2 seconds, press the RAIN/SET button  
4 more times—until the weekday digit flashes (default is “1”).  
2) Press the HISTORY/+ button to adjust the weekday.  
3) Press the RAIN/SET button to confirm the weekday digit, and to advance to  
set the Rain Alarm.  
V) RAIN ALARM SETTING  
Note: When the Rain Alarm is activated, the alarm will sound when rain is detected.  
The alarm will sound for approximately 150 seconds before automatically turning  
off. The alarm can also be turned off manually by pressing any button. If there is a  
break of no rain between two rain periods, the break must exceed 80 minutes for the  
alarm to sound.  
1) Hold down the RAIN/SET button for 2-seconds, press the RAIN/SET button  
5 more times—until the default “ALOFF” flashes.  
2) Press the HISTORY/+ button to adjust the alarm setting—“ALOFF” or  
“AL ON”.  
3) Press the RAIN/SET button to confirm the alarm setting, and to advance to  
Resetting the Total Rain Amount.  
VI) RESETTING THE TOTAL RAIN AMOUNT  
1) Hold down the RAIN/SET button for 2-seconds, press the RAIN/SET button  
6 more times—until the numerical digits flash under the “TOTAL” heading.  
2) Press the HISTORY/+ button to reset the total rain amount.  
3) Press the RAIN/SET button to confirm, and to exit the program mode.  
Note: The total rain amount will constantly accumulate unless the Rain  
Monitor is reset, or the batteries are changed.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES & OPERATIONS  
I) BAR GRAPH  
The bar graph displays the rainfall history. As indicated by the appearance of the  
word “HISTORY” at the left-central area of the LCD screen.  
The horizontal axis measures the past time periods, with “0” representing the current  
day, week, or month and “6” representing the oldest information (6 days ago, 6  
weeks ago, or 6 months ago). The graph reads from right to left.  
The vertical axis measures the rainfall in inches. The normal (default) measurement  
scale is {0, 0.1, 0.2, 0.3, 0.4, 0.5, 1, 2, 3, 4, 5, 10 inches}. If, within any selected  
time period (1 day, 1 week, 1 month), rainfall exceeds 20 inches the measurement  
scale automatically changes to {0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 100 inches}.  
The bar graph will display the rainfall history either by day, week, or month. To  
select which to display:  
1. Press the HISTORY/+ button. The “DAILY” icon will shift and become the  
“WEEKLY” icon (appearing across the central position of the LCD).  
2. Press the HISTORY/+ button to toggle through the “WEEKLY,”  
“MONTHLY,” and “DAILY” icons.  
If “DAILY” is selected, the graph will display the rainfall history for the  
past 6 days. The information that is displayed in column “0” (the right  
column) is renewed daily at midnight, and the information contained in the  
columns is shifted to the left. If “WEEKLY” is selected, the graph will  
display the rainfall history for the past 6 weeks. The information that is  
displayed in column “0” is renewed every Monday at midnight, and the  
information contained in the columns is shifted to the left. If “MONTHLY”  
is selected, the graph will display the rainfall history for the past 6 months.  
The information displayed in column “0” is renewed on the first day of  
every month, at midnight. The information contained in the columns is  
shifted to the left.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
II) NUMERICAL REPRESENTATION OF THE BAR GRAPH  
The bar graph displays the columns sequentially from “0” to “6” until all columns  
are showing. Then they are hidden again, and the sequential display is repeated. It is  
possible to read each column one at a time, simultaneously displaying the numeric  
measurement for that column above the bar graph. For example, the weekly rainfall  
total from 3 weeks ago may be viewed. Also, the numeric data from each column  
will correspond to the preveouly selected history (“DAILY,” “WEEKLY,” or  
“MONTHLY”). To view individual totals from the last six periods:  
1. Hold down the HISTORY/+ button for 2 seconds. The numeric data from  
column “0” should appear at the top of the LCD screen, with the  
“RAINFALL” icon displayed above the data.  
2. Press the HISTORY/+ button again, column “1” will be highlighted, and the  
numeric data will be displayed above the bar graph.  
3. Continue to press the HISTORY/+ button until the data from each column (0  
through 6) has been displayed.  
4. Pressing the HISTORY/+ button once more, after viewing the data from  
column 6, will exit this mode—returning to normal operation.  
III) MANUAL RESET OF THE RAIN MULTIPLICATOR  
Note: The rain multiplicator is the amount of rain needed to tip the teeter-totter  
bucket (inside the rain gauge). The multiplicator is preset to a value of “105”  
(0.0105 inches per tip); this number produces the most accurate rainfall  
measurement. There is no need to manually set this number unless it has been  
changed.  
1. Remove the batteries and wait 30 seconds. This will reset the 1-hour  
rainfall total, but the bar graph and other totals will remain.  
2. Checking the polarity, install batteries.  
3. During the brief 2 seconds that the LCD screen lights up, hold down the  
HISTORY/+ button, until “105” appears in the LCD (the “5” will be  
flashing).  
4. If the multiplicator is not 105; use the HISTORY/+ button to to change the  
last digit to a 5. Press the RAIN/SET button to confirm and shift to the  
middle digit.  
5. Press the HISTORY/+ button to change the middle digit, and press the  
RAIN/SET button to confirm and shift to the first digit. Repeat process for  
the first digit.  
6. Press the RAIN/SET button to exit the Rain Multiplicator mode, and to enter  
the normal mode. Follow Program Mode for set-up proceedures.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV) COMPLETE RESETTING OF PRECIPITATION DATA  
Note: The rain data held by the bar chart and other rain totals (excluding the  
1-hour total) will be stored and displayed again, even after the batteries have been  
removed. Therefore it is necessary to apply the following instructions to reset the  
bar chart and other totals, if desired.  
1) Enter the Rain Multiplicator mode as instructed in steps 1 through 3 of the  
Manual Reset of the Rain Multiplicator section above.  
2) After setting the rain multiplicator, while the left digit is flashing, press the  
RAIN/SET button for 8 seconds. This will clear data, and reset it to 0.  
V) RECEPTION REQUIRMENTS  
The Rain Monitor receives data from the Rainfall Transmitter every 5 minutes, while  
the Rainfall Transmitter transmits data every 1 minute. Data is transmitted  
immediately after rain has been detected. If 3 transmission attempts are made and no  
data is received, “---” will be displayed in the LCD. If this is the case, reset the Rain  
Monitor.  
A) RESETTING  
1) Remove batteries from the Rain Monitor and Rain Gauge.  
2) Wait 30 seconds, or start-up and transmission problems may arise, then  
reinstall the batteries.  
3) Follow Programming instruction.  
The Rain Monitor cannot receive data in the Programming Mode, nor during the  
numeric display of the bar chart. Reception is also interupted when a button is  
pressed, and will continue when the button is released.  
The transmission range is approximately 80 feet (25m) in open space. The  
surrounding environment and interference levels influence this transmission range.  
VI) ICONS  
A) FLASHING RAIN CLOUD  
A flashing rain cloud appears in the upper right hand corner of the LCD screen,  
when the Rainfall Transmitter is accumulating rain and transmitting data.  
B) SATELLITE ICON  
The satellite icon appears above the right column of the bar graph, when the  
Rain Monitor is searching for a signal from the Rainfall Transmitter.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOUNTING  
Note: Before permanently mounting, ensure that the Rain Monitor is able to receive  
signals from the Rainfall Transmitter at their desired location. Obstacles such as walls,  
concrete, and large metal objects can reduce the range. Place units in their desired  
location, and wait approximately 15 minutes before permanently mounting to ensure that  
there is proper reception  
I) THE TX5U—RAINFALL TRANSMITTER  
The Rainfall Transmitter can be mounted in two ways:  
simply placing it in a desired location, or  
mounting it to a surface with the provided screws.  
Ensure that the Rainfall Transmitter is completely horizontal and stable.  
1) Rotate the rainfall collector  
separating it from the base.  
2) There are two cylindrical  
holes in the base to guide  
the mounting screws. Place  
the base over a desired  
mounting surface. With a  
pencil, mark the mounting  
surface through the  
cylindrical holes.  
3) Where marked, start the screws.  
4) Place the base over mounting surface. Install screws through the cylindrical  
holes and into the started holes on the mounting surface.  
5) Secure the screws, ensuring that no part of the base can lift off the mounting  
surface.  
6) Remove the manufacture tape from the teeter-totter on the base. If this is  
not done there will be no way to measure rainfall, and no measurement will  
display on the Weather Center.  
7) Place the rainfall collector onto the base. Place the 3 tabs (on the rainfall  
collector) into the tab slots (on the base) and turn counter-clockwise.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II) THE WIRELESS RAIN MONITOR  
The Rain Monitor can also be mounted in two ways:  
with the table stand or,  
on the wall with the use of a wall hanging screw (not included).  
A) USING THE TABLE-STAND  
1. The Rain Monitor comes with the table stand already mounted. If you  
wish to use the table-stand all that is required is to place the Rain  
Monitor in an appropriate location.  
B) WALL MOUNTING  
Figure 3  
1. Remove the table stand. To do this,  
pull down on the stand from the rear  
and rotate forward. (Figure 3).  
2. Fix a screw (not included) into the  
desired wall, leaving approximately  
3/16 of an inch (5mm) extended from  
the wall. (Figure 4).  
Figure 4  
3. Place the Rain Monitor onto the screw  
using the hanging hole on the  
backside. Gently pull the Rain  
Monitor down to lock the screw into  
place.  
MAINTENANCE & CARE  
Extreme temperatures, vibrations, and shock should be avoided to prevent damage to  
the units.  
Clean displays and units with a soft, damp cloth. Do not use solvents or scouring  
agents—they may mark and damage the displays and casings.  
Do not submerge in water.  
Immediately remove all low powered batteries to avoid leakage and damage.  
Replace with new batteries only, and of recommended size.  
Opening the casings invalidates the warranty. Do not try to repair the units. Contact  
La Crosse Technology for Repairs.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Problem:  
Solution:  
Problem:  
Solution:  
The LCD is faint.  
1) Replace batteries.  
“OFL” appears in LCD.  
1) Follow Reset directions. (Total rainfall accumulation has  
exceeded 999.99in.)  
Problem:  
Solution:  
“---” Appears in LCD (rain monitor has lost signal from gauge)  
1) Follow reset directions.  
2) Distance the Rain Monitor or Rainfall Transmitter at least 6 feet  
(2m) away from interfering sources on a 433 MHz signal  
(computers, TV sets, headphones, speakers, etc.).  
3) Move receiver away from metal window frames.  
4) Neighbors using 433 MHz devices can interfere also.  
Need to reset the bar graph (EEPROM Rain Monitor memory)  
1) Remove batteries, and follow instructions in section III, under  
Features & Operations.  
Problem:  
Solution:  
Problem:  
Solution:  
Rainfall amount is not correct.  
1) Manually change the rain multiplicator number to 105, following  
instructions in section II, under Features & Operations.  
Note: For any questions not answered, contact La Crosse Technology with the contact  
information found at the end of this instructional manual.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Recommended operating temperature:  
Rain Monitor:  
32°F to 122°F (0°C to 50°C)  
Rainfall Transmitter:  
Rainfall Totals:  
32°F to 122°F (0°C to 50°C)  
For the previous 6 days, 6 weeks, 6 months,  
plus current day, week, or month  
Data Check Intervals:  
Receiver checking interval:  
Every 5 minutes  
Rainfall Transmitter checking interval: Every minute if no rain, immediately when rain  
begins  
Transmission frequency:  
Maximum transmission range:  
433.92 MHz  
80 feet (25m)  
Power supplies (Alkaline battery recommended):  
Rain monitor:  
2 x AAA, IEC LR3, 1.5V batteries  
Rainfall Transmitter:  
Dimensions (L x W x H):  
Rain monitor (without stand):  
Rainfall Transmitter:  
2 x AA, IEC LR6, 1.5V batteries  
3.54 x 0.86 x 4.13in (90 x 22 x 105mm)  
5.19in diameter x 7.20in high  
(132mm diameter x 183mm high)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY INFORMATION  
La Crosse Technology provides a 1-year warranty on this weather station. Contact La  
Crosse Technology immediately upon discovery of any defects covered by this warranty.  
Before sending the Weather Station in for repairs, contact La Crosse Technology. The  
Weather Station will be repaired or replaced with the same or similar model.  
This warranty does not cover any defects resulting from improper use, unauthorized  
repairs, faulty batteries, or the Weather Stations inability to receive a signal due to any  
source of interference.  
LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL,  
CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED  
WITH THE OPERATION OR MALFUNCTION OF THIS WEATHER STATION.  
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR  
PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF  
CHILDRE’S REACH.  
This warranty gives you specific legal rights. You may also have other rights specific to  
your State. Some States do no allow the exclusion of consequential or incidental  
damages therefore the above exclusion of limitation may not apply to you.  
For warranty work, technical support, or information contact  
La Crosse Technology  
190 Main Street  
La Crescent, MN 55947  
Phone: 507.895.7095  
Fax: 507.895.8000  
e-mail:  
(warranty work)  
(information on other products)  
web:  
All rights reserved. This handbook must not be reproduced in any form, even in excerpts,  
or duplicated or processed using electronic, mechanical or chemical procedures without  
written permission of the publisher.  
This handbook may contain mistakes and printing errors. The information in this  
handbook is regularly checked and corrections made in the next issue. We accept no  
liability for technical mistakes or printing errors, or their consequences.  
All trademarks and patents are acknowledged.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lanier Copier 5685 User Manual
Lennox Hearth Indoor Fireplace Ravelle 42 User Manual
Linksys Network Router EA2700 User Manual
Lucent Technologies Network Card STGRCR LIM AP 48 User Manual
Mackie DJ Equipment VLZ3 4BUS User Manual
Makita Impact Driver 6901D User Manual
Marantz Stereo System PMD680 User Manual
Mark Of Fitness Computer Monitor MF 180 User Manual
Marshall electronic Flat Panel Television V R70P SD User Manual
MAXDATA Computer Accessories 501302SD8GCL10 User Manual