3. Do not press any buttons for at least ten minutes. If a button is pressed before the
indoor weather station has received information from the TX4U sensor, no data
will be received from that sensor until reset.
III. Explanation of LCD Information
A. The below picture highlights the LCD features.
4. Replace the battery cover.
Radio-controlled
II. Start Up Sequence
A. Initial Start
WWVB Reception
Indicator
1. Immediately after the batteries have been installed, the indoor weather station
will sound a “beep”, and the LCD will completely light up for a brief moment.
2. All information will then appear in normal mode, with “12:00” as the default time
and “TH.1” as the default date (2004 as the year).
3. The indoor temperature and humidity, and barometric air pressure (as 29.91 inHg
relative RH) will also be displayed.
Date Display
Comfort Icon
Moon Phase Display
4. There is a “satellite” icon that appears in the bottom portion of the LCD, between
the outdoor temperature and humidity - this icon informs the user that the indoor
weather station is looking for signals from the remote thermo/hygro sensor. Within
five minutes the remote temperature and humidity should be displayed-if not,
remove batteries from all units and repeat battery installation, the remote tem-
perature sensor first, then the indoor weather station.
Indoor Temperature
Humidity Display
Forcast Icon
Air Pressure
Trend Indicator
B. WWVB Reception
1. Once the batteries are installed in the Weather Center, it will automatically search
for the WWVB signal. If it receives a good signal (which is unlikely during daylight
hours in most locations), the WWVB reception indicator (looks like a tower icon)
will flash. The indoor weather station requires five full minutes of good reception
to successfully capture the signal and set to the correct hour, minute, second,
month, day and year. If the signal reception is not successful within ten minutes,
the signal search will be cancelled and will automatically resume every two hours
until the signal is successfully captured.
Barometric Air
Pressure
24-hour Air
Pressure History
2. The signal is sent from Ft. Collins, Colorado only and is similar to an AM radio
signal. Atmospheric interferences such as storms, sunspots, and even sunlight
will cause the signal to not travel as far.
3. To maximize reception, place the indoor weather station in a window facing
Colorado, at least six feet from any electrical source (computers, televisions,
refrigerators, etc.). Do not move the indoor weather station while it is searching
for the signal.
Outdoor Temperature
Humidity Display
4. The time and date can be manually set. Once the signal is captured, it will over-
ride any time and date set to the time zone selected.
5. Once the time and date are set, the indoor weather station will conduct a search
every night at midnight and correct to the accurate time and date (Daylight Sav-
ing Time is automatic). If the signal has been received in the past 24 hours, the
reception indicator will be displayed.
Remote Sensor Number
(Up to 3 Total)
B. There are many different modes the indoor weather station can be set to. The
LCD shown is the normal operating mode, and your actual data shown will be
different based on your local settings and conditions.
GB P.6
P.7 GB
IV. Function Key Layout
D. DST ON/OFF Setting
A. The below picture shows the five function keys used in programming and opera-
tion of your indoor weather station
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button twice more to advance to the DST ON/OFF
setting.
4. “DST” will appear to the right of the Moon Phase display and “ON” or “OFF” will
flash above that.
5. Press and release the “OUT/+” button to select DST ON/OFF.
Note: Some locations (Arizona and parts of Indiana) do not follow Daylight Saving
Time.
V. Program Mode
6. Press and release the “SET” button to confirm the DST ON/OFF setting and
continue to the Radio-controlled Time ON/OFF setting.
The program mode is laid out in a manner that allows you to program each function
separately, or you can follow the instructions entirely to program the indoor weather
center. Complete programming is usually done for the initial set-up, and will require
you to skip step 1,2 and 3 of each programming section. The programming mode
can be exited at any time by either pressing the “Snooze/CH” button, or waiting for
the 15-second time-out to take effect.
E. Radio-controlled Time ON/OFF Setting
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button three more times to advance to the Radio-
controlled time ON/OFF setting.
A. Overview of programming mode sequence
4. “RCC” will appear to the right of the Moon Phase display and “ON” or “OFF” will
flash above that.
1. LCD Contrast
2. Time Zone
3. DST ON/OFF
5. Press and release the “+” button to select Radio-controlled time ON/OFF setting.
6. Press and release the “SET” button to confirm the Radio-controlled time ON/OFF
setting and continue to the 12/24-hour Time Mode setting.
4. Radio-controlled Time ON/OFF 5. 12/24-hour time mode 6. Hour
7. Minute
8. Year
9. Month
10.Date
11.˚F/˚C
12.inHg/hPa
13.Relative pressure setting
14.Forecast sensitivity
F. 12/24-hour Time Mode
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button four more times to advance to the 12/24-hour
time mode setting.
4. “12h” or “24h” will flash to the right of the Moon Phase display.
5. Press and release the “OUT/+” button to select 12 or 24-hour time mode.
B. LCD Contrast Setting
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “OUT/+” button to select the desired LCD contrast setting.
4. Press and release the “SET” button to confirm the LCD contrast setting and con-
tinue to the Time Zone setting
Note: In 12h mode “PM” will appear to the left of the time during PM hours. If the
time is not within the PM hours nothing will be displayed. Be sure to set the time to
the correct AM/PM time to ensure automatic reception.
C. Time Zone Setting
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button once more to advance to the Time Zone
setting.
6. Press and release the “SET” button to confirm the 12/24-hour time mode setting
and continue to the Hour setting
4. A number will flash to the left of the letter “h” at the top of the display just below
the time display.
G. Setting The Hour Manually
5. Press and release the “+” button to select the desired time zone.
6. Press and release the “SET” button to confirm the Time Zone setting and con-
tinue to the DST ON/OFF setting.
The WWVB signal will override any manual set time and date information. The time
will be based on the time zone selected.
Download from Www.Somanuals.com. All Manuals Search And Download.
GB P.8
P.9 GB
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button five more times to advance to the Manual
Hour setting.
5. Press and release the “OUT/+” button to select the desired date.
6. Press and release the “SET” button to confirm the date and continue to the Tem-
perature Measuring Units setting.
4. The hour will begin to flash at the top of the display.
5. Press and release the “OUT/+” button to select the desired hour.
6. Press and release the “SET” button to confirm the hour setting and continue to
the Minute setting.
L. Temperature Measuring Units Selection (˚F or ˚C)
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button ten more times to advance to the Tempera-
ture Measuring Units setting.
H. Setting The Minutes Manually
4. ˚F or ˚C will flash at the top of the display.
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button six more times to advance to the Manual
Minutes setting.
5. Press and release the “OUT/+” button to select the desired temperature measur-
ing unit.
6. Press and release the “SET” button to confirm the temperature measuring unit
and continue to the Air Pressure Measuring Units setting.
4. The minutes will begin to flash at the top of the display.
5. Press and release the “OUT/+” button to select the desired minutes.
6. Press and release the “SET” button to confirm the minutes and continue to the
Year setting.
M. Air Pressure Measuring Units Selection (inHg/hPa)
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button eleven more times to advance to the Air
Pressure Measuring Units setting.
I. Setting TheYear Manually
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button seven more times to advance to the Manual
Year setting.
4. The year will begin to flash to the right of the Moon Phase display.
5. Press and release the “OUT/+” button to select the desired year.
6. Press and release the “SET” button to confirm the year and continue to the Month
setting.
4. inHg or hPa will flash at the top of the display.
5. Press and release the “OUT/+” button to select the desired air pressure measur-
ing unit.
6. Press and release the “SET” button to confirm the air pressure measuring unit
and continue to the Relative Pressure setting.
N. Relative Pressure Setting
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button twelve more times to advance to the Relative
Pressure setting.
4. The barometric air pressure will flash in the middle of the display, just below the
forecast icon
5. Press and release the “OUT/+” or “IN” button to select the desired air pressure
measuring unit.
6. Press and release the “SET” button to confirm the relative pressure setting and
continue to the Forecast Sensitivity setting.
J. Setting The Month Manually
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button eight more times to advance to the Manual
Month setting.
4. The Month will begin to flash to the right of the Moon Phase display.
5. Press and release the “OUT/+” button to select the desired month.
6. Press and release the “SET” button to confirm the month and continue to the
Date setting.
O. Forecast Sensitivity Setting
K. Setting The Date Manually
1. Press and hold the “SET” button for five seconds.
1. Press and hold the “SET” button for five seconds.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button nine more times to advance to the Manual
Date setting.
2. “lcd” will appear at the top of the display and a number will flash next to it.
3. Press and release the “SET” button thirteen more times to advance to the Fore-
cast sensitivity setting.
4. The two air pressure tendency arrows will begin flashing on either side of the
forecast icon and a flashing number will appear under the forecast icon.
4. The date will begin to flash to the right of the Moon Phase display.
GB P.10
P.11 GB
5. Press and release the “OUT/+” button to select the desired forecast sensitivity
setting.
B. Moon Phase
1. There are 12 moon phases shown on the indoor weather station; the black por-
tion signifies the portion of the moon visible in the sky.Thus, when the moon icon
is all black, it is a full moon. The indoor weather station is programmed with all
moon phases from the year 2003 until 2029.
Note: Barometric air pressure is usually reported as “relative air pressure”. This
reading is based on the combination of absolute air pressure and altitude. In general,
an increase in altitude will result in a decrease in air pressure. Relative air pressure
will make readings in nearby locations relative to each other to allow for proper
forecasting. The absolute air pressure reading in the Weather Center cannot be
calibrated, only the relative air pressure.
Waxing Crescent
New Moon
Waxing Gibbous
First Quarter
6. Press and release the “SET” button to confirm the forecast sensitivity setting.
THE MANUAL SETTING IS NOW COMPLETED
FEATURES AND OPERATIONS
A. Time Alarm Setting and Operation
1. To set the time alarm:
a. Press and hold the ALM/DATE button for 5 seconds.
b. The alarm time will begin to flash to the right of the moon phase.
c. Press and release the IN button to adjust the hour.
Full Moon
Last Quarter
Waning Gibbous
Waning Crescent
C. Minimum and Maximum Temperature and Humidity
1. Indoor Minimum and Maximum Temperature and Humidity
Note: When in the 12-hour mode and setting an alarm for a time between noon and
midnight, “PM” will appear to the left of the alarm time.
The indoor weather station automatically stores the minimum and maximum indoor
temperature and humidity. The minimum and maximum values are updated auto-
matically when a new minimum or maximum is recorded, or until manually reset.
d. Press and release the OUT/+ button to adjust the minutes.
e. Press and release either of the SNOOZE/CH buttons to confirm the setting or
wait for 20 seconds and the display will automatically return to the normal mode.
a. From the normal display mode, press and release the “IN” key once to view the
indoor maximum temperature and humidity (“MAX” will be displayed above the
indoor temperature and humidity).
2. To activate the alarm:
a. Press and release the ALM/DATE button to toggle between the alarm time and
the day and date.
b. When the alarm time and alarm icon are showing to the right of the moon phase
the alarm is activated.
b. Press and release the “IN” key again to view the indoor minimum temperature
and humidity.
c. Press and release the “IN” key again to return to the normal mode (timeout of
viewing minimum/maximum values will occur if no keys are pressed for fifteen
seconds).
c. When the day and date are showing in the DATE LCD the alarm is deactivated.
Note: To reset the indoor minimum and maximum temperature and humidity, first
display the values you wish to reset (minimum or maximum). Next press and hold
the “SET” key for at least three seconds. You will see then that the values will reset
to the current temperature and humidity and corresponding time.
3. To activate the snooze:
a. While the alarm is sounding press and release the SNOOZE/CH button.
b. The snooze will be activated for 10 minutes. The alarm will come back on after
10 minutes.
c. To deactivate the snooze function press and release any button other than either
of the SNOOZE/CH buttons.
2. Outdoor Minimum and Maximum Temperature and Humidity
The indoor weather station automatically stores the minimum and maximum out-
door temperature and humidity. The minimum and maximum values are updated
automatically when a new minimum or maximum is recorded, or until manually reset.
Download from Www.Somanuals.com. All Manuals Search And Download.
GB P.12
P.13 GB
a. From the normal display mode, press and release the “OUT/+” key once to view
the outdoor maximum temperature and humidity (“MAX” will be displayed above
the outdoor temperature and humidity).
b. Press and release the “OUT/+” key again to view the outdoor minimum tempera-
ture and humidity.
Each remote sensor will have its own minimum and maximum values stored.
E. Comfort Indicator for Indoor Temperature and Humidity
1. The comfort level indicator appears inbetween the indoor tempearture and
humidity.
c. Press and release the “OUT/+” key again to return to the normal mode (timeout
of viewing minimum/maximum values will occur if no keys are pressed for fifteen
seconds).
2. The indicator will display a “happy-face” when the temperature is between 68˚F
and 79˚F (20˚C and 25.9˚C), and the humidity is between 45% and 64%.
3. A “sad-face” will be displayed when the temperature and humidity are outside the
mentioned ranges.
d. Note: To reset the outdoor minimum and maximum temperature and humidity,
first display the values you wish to reset (minimum or maximum). Next press and
hold the “SET” key for at least three seconds. You will see then that the values
will reset to the current temperature and humidity and corresponding time.
F. Weather Forecast Icon and Pressure Trend Indicators
The weather forecasting feature is estimated to be 75% accurate, and is based solely
upon the change of air pressure over time. The WS-9032U averages past air-pres-
sure readings to provide an accurate forecast-creating a necessity to disregard all
weather forecasting for 12-24 hours after the unit has been set-up, reset, or moved
from one altitude to another (i.e. from one floor of a building to another floor). In
areas where the weather is not affected by the change of air pressure, this feature
will be less accurate.
D. Multiple Remote Temperature Sensors
The WS-9032U is able to receive signals from 3 different remote sensors. These
extra remote sensors can be purchased through the same dealer as this unit. A
TX4U will monitor the temperature and humidity, a TX3U will monitor temperature
and display the temperature on its LCD, a TX3UP will monitor the temperature via a
probe for measuring soil or water temperatures and a TX6U will monitor the tem-
perature only.
1. Weather Icons
a. There are 3 possible weather icons that will be displayed at various times in the
center of the indoor weather station.
Note: When setting up multiple units it is important to insert batteries first into all the
remote sensors, and in numeric sequence. Second install batteries into the indoor
weather station. Transmission problems will arise if this is not done correctly and if
the total time for set-up exceeds 6 minutes
1. Set Up of Multiple Units
a. It is necessary to remove the batteries from all units currently in operation.
b. Remove the battery covers to all remote sensors.
c. Place all remote sensors in a numeric sequential order.
d. In sequential order, install batteries following the same battery installation proce-
dures seen in Detailed Set-Up Guide section of this manual.
e. Install batteries into the indoor weather station.
i
Sunny-indicates that the weather is expected to improve (not that the weather
will be sunny).
ii Sun with Clouds-indicates that the weather is expected to be fair (not that the
weather will be sunny with clouds).
iii Clouds with Rain-indicates that the weather is expected to get worse (not that
the weather will be rainy).
b. The weather icons change when the unit detects a change in air pressure.
c. The icons change in order, from “sunny” to “sun with clouds” to “clouds with rain”
or the reverse.
f. Follow the Detailed Set-Up Guide for programming and operating instructions.
2. Viewing and Operating with Multiple Remote Sensors
a. To view the temperature of a different remote sensor press and release either of
the “SNOOZE/CH” buttons. A shift from one “boxed” number to the next should
be observed in the OUTDOOR LCD.
d. It will not change from “sunny” directly to “clouds with rain”, although it is possible
for the change to occur quickly.
e. If the symbols do not change, the weather has not changed (or the change has
been slow and gradual).
b. The minimum and maximum temperature of the additional remote sensor can be
displayed by pressing the “OUT/+” button.
f. The sensitivity of the change in foreacst icon is set by the user in section F of the
Detailed Set Up Guide.
c. To reset the minimum and maximum temperature readings press and hold the
“SET” button for 3 seconds and that temperature/humidity record for that remote
sensor will be reset only.
GB P.14
P.15 GB
G. Weather Tendency Arrows
has a falling trend, and the weather should worsen.
8. Multiply the two values to find past air pressure (note the + or - sign of values on
the verticle axis); i.e. 0.03 hPa x 3 = 0.09 hPa, now add this value to the air
pressure (in LCD 4) to evaluate what past air pressures have been.
9. The bar chart will constantly scroll to avoid burnout of the LCD.
Pressure trend arrow
Note: This feature cannot be turned off.
1. Along with the forecast icon there is a pressure tendency arrow.
2. There is one that points up (on the left side of the LCD) and one that points down
(on the right side of the LCD).
3. These arrows reflect current changes in the air pressure.
4. An arrow pointing up indicates that the air pressure is increasing and the weather
is expected to improve or remain good.
5. An arrow pointing down indicates that the air pressure is decreasing and the
weather is expected to become worse or remain poor.
6. No arrow means the pressure is stable.
7. A storm can be expected if there is a drop of 4 hPa or more in less than 6 hours.
The clouds with rain icon will be displayed and the tendency arrow that points
down will be flashing-indicating the storm warning feature has been activated.
The flashing will stop when the air pressure stabilizes or begins to rise.
MOUNTING
Note: Before permanently mounting, ensure that the indoor weather station is able
to receive signals from the transmitters and WWVB signal at the desired location.To
achieve a true temperature reading, avoid mounting the remote thermo/hygro sen-
sor (or any sensor) where direct sunlight can reach the remote sensor. We recom-
mend that you mount the remote sensor on a North-facing wall or under an eve. The
sending range of the remote thermo/hygro sensor is 330-ft (100m) however obstacles
such as walls, concrete, and large metal objects can reduce the range. Place all
units in their desired location, and wait approximately 15 minutes before perma-
nently mounting to ensure that there is proper reception. If the indoor weather sta-
tion loses the signal from the remote sensor, it will display the last temperature read-
ing for 15 minutes. After 15 minutes of not receiving any signals, the remote tem-
perature will display “- -.-”.
H. Barometric Air Pressure Reading
1. The actual barometric air pressure is displayed directly under the weather fore-
cast icon
2. The relative air pressure is calibrated by the user through the programming mode.
3. Please Follow the programming instructions in section F of the Detailed Set Up
Guide to set this feature.
A. Mounting the Remote Thermo/hygro Sensor
The remote thermo/hygro sensor can be mounted with the use of screws or by using
the adhesive tape.
1. Mounting with screws
a. Remove the mounting bracket/receptor from the packaging.
b. Place the mounting bracket over the desired mounting surface.
c. Through the 2 screw holes of the bracket, mark the mounting surface with a
pencil.
I. Air Pressure History Bar Chart
1. The bar graph shows in hPa (Hekto Pascal) the recorded air pressure over the
past 24-hours.
2. The horizontal axis shows the hours at increments of -24 hours, -18 hours, -12
hours, -9 hours, -6 hours, -3 hours, and 0 hours (current).
3. The vertical axis is set by hPa: the “0” on this axis represents the current hPa,
and + or - 1,3,5, or 7 shows (in hPa) how high or low the past air pressure was as
compared to the current one.
d. Where marked, start the screw holes using the provided screws.
e. Remove screws from the mounting surface.
f. Align the mounting bracket with the started screw holes.
g. Screw mounting bracket onto the mounting surface. The screws should be flush
with the bracket.
4. The “0” on the vertical axis indicates the current air pressure value.
5. The “0h” on the horizontal axis indicates the current hour, thus the current air
pressure also.
h. Fit the mounting post (on the back of the transmitter) into the receptor of the
mounting bracket.
6. Each bar on the bar graph represents a value of 0.03 hPa, and each bar also has
a corresponding value on the verticle axis.
7. Air pressure trends can be determined by simply glancing at the bar graph.
a. If the bars are rising (higher on the right than the left) then the air pressure has
a rising trend, and the weather should improve.
b. If the bars are dropping (lower on the right than the left) then the air pressure
REMOTE
REMOTE
THERMO-SENSOR
THERMO-SENSOR
433 MHz
433 MHz
Download from Www.Somanuals.com. All Manuals Search And Download.
GB P.16
P.17 GB
2. Mounting with Adhesive Tape
D. Immediately remove all low powered batteries to avoid leakage and damage.
E. Opening the casings invalidates the warranty. Do not try to repair the unit. Con-
tact La Crosse Technology for repairs.
a. With a nonabrasive solution, clean and dry the back of the mounting bracket and
the mounting surface to ensure a secure hold. The mounting surface should be
smooth and flat.
b. Remove the protective strip from one side of the tape.
c. Press firmly onto the designated area on the back of the mounting bracket.
d. Remove the protective strip from the other side of the tape, and situate the mount-
ing bracket.
e. Firmly press the mounting bracket onto the mounting surface.
f. Fit the mounting post into the receptor of the mounting bracket.
TROUBLESHOOTING
Problem:
Solution:
1) Set the LCD contrast to a higher level.
2) Replace batteries.
The LCD is faint.
Problem:
No outdoor temperature/humidity is displayed.
B. Mounting the WS-9032U Indoor Weather Station
Solution:
The indoor weather station can be mounted in two ways; free standing or hanging on
a wall.
1) Remove all batteries, reinsert into the remote thermo/hygro sensor first, then into
the indoor weather station.
2) Place remote thermo/hygro sensor closer to the indoor weather station.
3) Be sure all batteries are fresh.
4) No other interfering sources are being used (such as computer monitors, TV
sets, headphones, or speakers) in the vicinity. The signal travels in a straight line,
an electrical source near that “line” may cause interference.
Problem:
Solution:
Temperature, humidity, or air pressure is incorrect.
1) Check/Replace batteries.
2) If multiple remote sensors are in use, check location with corresponding “boxed
numbers.”
3) Move away from sources of heat/cold.
4) Adjust relative air pressure to a value from a reliable source (TV radio, etc.).
5) The indoor weather station and remote sensors are calibrated at the factory. If
there is a consistent problem, please call La Crosse Technology.
To have the indoor weather station free standing, simply unfold the stands on the
back and set on a stable flat surface.
To wall mount the indoor weather station;
Problem:
Solution:
“- -” in humidity display.
1. Ensure that the integrated stands are folded in.
1) Humidity is below 1% or above 99%.
2. Fix a screw (not included) into the desired wall, leaving approximately 3/16 of an
inch (5mm) extended from the wall.
2) TX3U or TX3UP is used for remote temperature.
3. Place the indoor weather station onto the screw using the hanging hole on the
backside.
Problem:
Solution:
WWVB time and date will not set or update
4. Gently pull the indoor weather station down to lock the screw into place.
1) Wait until overnight for signal to be received
2) Move indoor weather station away from sources of electricity
3) Place indoor weather station in window facing Colorado
4) The first reception is most difficult, as the indoor weather station needs five con-
tinual minutes of clear signal reception. After the initial time/date set, the indoor
weather station only requires one full minute of clear reception each night.
MAINTENANCE AND CARE INSTRUCTIONS
A. Extreme temperatures, vibration, and shock should be avoided to prevent dam-
age to the units.
B. Clean displays and units with a soft, damp cloth. Do not use solvents or scouring
agents; they may mark the displays and casings.
C. Do not submerge in water.
GB P.18
P.19 GB
SPECIFICATIONS
This limited warranty begins on the original date of purchase, is valid only on prod-
ucts purchased and used in North America and only to the original purchaser of this
product. To receive warranty service, the purchaser must contact La Crosse
Technology, Ltd for problem determination and service procedures. Warranty ser-
vice can only be performed by a La Crosse Technology, Ltd authorized service center.
The original dated bill of sale must be presented upon request as proof of purchase
to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service
center.
Indoor weather station recommended
operating temperature
LCD contrast
Temperature measuring range
Indoor
32˚F to 122˚F (0˚C to 50˚C)
8 levels (0-7)
14.2˚F to 139.8˚F with 0.2˚F resolution
(-9.9˚C to 59.9˚C with 0.1˚C resolution)
(“OFL” displayed if outside this range)
Outdoor
-21.8˚F to 157.8˚F with 0.2˚F resolution
(-29.9˚C to 69.9˚C with 0.1˚C resolution)
(“OFL” displayed if outside this range)
La Crosse Technology, Ltd will repair or replace this product, at our option and at no
charge as stipulated herein, with new or reconditioned parts or products if found to
be defective during the limited warranty period specified above. All replaced parts
and products become the property of La Crosse Technology, Ltd and must be re-
turned to La Crosse Technology, Ltd. Replacement parts and products assume the
remaining original warranty, or ninety (90) days, whichever is longer. La Crosse
Technology, Ltd will pay all expenses for labor and materials for all repairs covered
by this warranty. If necessary repairs are not covered by this warranty, or if a prod-
uct is examined which is not in need or repair, you will be charged for the repairs or
examination. The owner must pay any shipping charges incurred in getting your La
Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service
center. La Crosse Technology, Ltd will pay reasonable return shipping charges to
the owner of the product.
Relative humidity range
Indoor/Outdoor
weather station
1% to 99% with 1% resolution, indoor
displays “—.-” if outside this range
Air pressure
Relative hPa (adjustable)
Relative inHg (adjustable)
Sensitivity setting hPa
Air pressure history
18, and -24 hours)
Data checking intervals
Indoor temperature
Indoor humidity
Outdoor temperature
Outdoor humidity
Transmitter reading update (within sensor)
Outdoor temperature
Outdoor humidity
Transmission frequency
Transmission range
Power supply
960 hPa to 1040 hPa
28.35 inHg to 30.72 inHg
2 hPa to 4 hPa
For the past 24 hours (0, -3, -6, -9, -12, -
Every 15 second
Every 20 seconds
Every 5 minutes
Every 5 minutes
Your La Crosse Technology, Ltd warranty covers all defects in material and work-
manship with the following specified exceptions: (1) damage caused by accident,
unreasonable use or neglect (including the lack of reasonable and necessary
maintenance); (2) damage occurring during shipment (claims must be presented to
the carrier); (3) damage to, or deterioration of, any accessory or decorative surface;
(4) damage resulting from failure to follow instructions contained in your owner’s
manual; (5) damage resulting from the performance of repairs or alterations by some-
one other than an authorized La Crosse Technology, Ltd authorized service center;
(6) units used for other than home use (7) applications and uses that this product
was not intended or (8) the products inability to receive a signal due to any source of
interference.. This warranty covers only actual defects within the product itself, and
does not cover the cost of installation or removal from a fixed installation, normal set-
up or adjustments, claims based on misrepresentation by the seller or performance
variations resulting from installation-related circumstances.
Every 1 minute
Every 1 minute
433.92 MHz
330 feet (100m)
Weather Center:
3 x AA (IEC LR6) 1.5V batteries.
2 x AA (IEC LR6) 1.5V batteries.
Thermo Hygro Transmitter:
Dimensions (H x W x D)
Indoor weather station
8.93 x 4.62 x 1.22 inches
(227 x 117.4 x 31.2 mm)
4.29 x 1.56 x 0.78 inches
(110 x 40 x 20 mm)
Remote thermo/hygro sensor
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES
ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT.
THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUB-
LIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S
REACH.
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against
manufacturing defects in materials and workmanship.
Download from Www.Somanuals.com. All Manuals Search And Download.
GB P.20
P.21 GB
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this
product against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid
only on products purchased and used in North America and only to
the original purchaser of this product. To receive warranty service,
the purchaser must contact La Crosse Technology, Ltd for problem
determination and service procedures. Warranty service can only be
performed by a La Crosse Technology, Ltd authorized service center.
The original dated bill of sale must be presented upon request as
proof of purchase to La Crosse Technology, Ltd or La Crosse
Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our
option and at no charge as stipulated herein, with new or
reconditioned parts or products if found to be defective during the
limited warranty period specified above. All replaced parts and
products become the property of La Crosse Technology, Ltd and
must be returned to La Crosse Technology, Ltd. Replacement parts
and products assume the remaining original warranty, or ninety (90)
days, whichever is longer. La Crosse Technology, Ltd will pay all
expenses for labor and materials for all repairs covered by this
warranty. If necessary repairs are not covered by this warranty, or if
a product is examined which is not in need or repair, you will be
charged for the repairs or examination. The owner must pay any
shipping charges incurred in getting your La Crosse Technology, Ltd
product to a La Crosse Technology, Ltd authorized service center.
La Crosse Technology, Ltd will pay ground return shipping charges to
the owner of the product to a USA address only.
Your La Crosse Technology, Ltd warranty covers all defects in
material and workmanship with the following specified exceptions: (1)
damage caused by accident, unreasonable use or neglect (including
the lack of reasonable and necessary maintenance); (2) damage
occurring during shipment (claims must be presented to the carrier);
(3) damage to, or deterioration of, any accessory or decorative
surface; (4) damage resulting from failure to follow instructions
contained in your owner’s manual; (5) damage resulting from the
performance of repairs or alterations by someone other than an
authorized La Crosse Technology, Ltd authorized service center; (6)
units used for other than home use (7) applications and uses that this
product was not intended or (8) the products inability to receive a
signal due to any source of interference.. This warranty covers only
actual defects within the product itself, and does not cover the cost of
installation or removal from a fixed installation, normal set-up or
1
Download from Www.Somanuals.com. All Manuals Search And Download.
adjustments, claims based on misrepresentation by the seller or
performance variations resulting from installation-related
circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY
FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER
SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR
MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO
BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC
INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF
CHILDREN’S REACH.
This warranty gives you specific legal rights. You may also have
other rights specific to your State. Some States do no allow the
exclusion of consequential or incidental damages therefore the above
exclusion of limitation may not apply to you.
For warranty work, technical support, or information contact:
La Crosse Technology, Ltd
2809 Losey Blvd S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
e-mail:
(warranty work)
(information on other products)
web:
2
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC DISCLAIMER
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
La Crosse Technology
Made in China
All rights reserved. This handbook must not be reproduced in any
form, even in excerpts, or duplicated or processed using electronic,
mechanical or chemical procedures without written permission of the
publisher.
This handbook may contain mistakes and printing errors. The
information in this handbook is regularly checked and corrections
made in the next issue. We accept no liability for technical mistakes
or printing errors, or their consequences.
All trademarks and patents are acknowledged.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
|