LST Smoke Alarm 7251 User Manual

Optical Laser Smoke Detector  
7251  
• ADM loop technology with  
System Sensor/200 protocol  
• Up to 100 times more sensitive than  
common optical smoke detectors  
• Sensitivity selectable in 9 steps  
• Optional pre-alarm function  
• Automatic drift compensation  
• Highly insensitive to contamination  
• Function testable with magnet  
Description  
The addressable Optical Laser Smoke Detector 7251 The proven ADM loop technology with System Sen-  
uses the scattered light principle, and was developed sor/200 protocol establishes a permanent communica-  
for the precise detection of smoke particles in a wide tion between the fire detection control panel and the  
range of applications. The modern design of the sen- detector. That ensures a periodical function testing of  
sing chamber allows to reliably evaluate the characte- the detector. In the control panel all types of fires are  
ristics of fire.  
detected by continuously comparing fire patterns.  
Due to the high sensitivity of the laser detection cham- The influence of contamination on the optical measu-  
ber, the detector is ideal for applications where an early rement system is reduced with the help of the laser  
fire detection is crucial:  
• Computer rooms  
• Clean room manufacturing  
• Hospitals  
principle and furthermore compensated for by using in-  
telligent evaluation algorithms. With that, the response  
sensitivity of the detector is kept constant for a long  
time – a further effective step to avoid false alarms.  
• Aspiration smoke detection systems  
The two LEDs with 360° visibility indicate the activated  
Depending on the application, the high sensitivity of the condition of the detector. The detector address is selec-  
detector is individually adjustable in 9 steps between ted with two decadic rotary switches, thus allowing to  
0.03%/m and 3.3%/m and provides a number of spe- quickly change the detector without additional tools.  
cial applications, which can not be covered using stan-  
dard optical smoke detectors.  
A detector function test can be conveniently conducted  
An optional pre-alarm can be activated two sensitivity using a magnet. The detector can be attached to va-  
levels before reaching the alarm level.  
rious bases and it can be protected against theft.  
Building Safety. Building Security.  
A
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27  
7251_DBL_LST_EN_0819.PDF • PAGE 1  
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lasko Outdoor Misting Fan 7050 User Manual
LG Electronics Headphones HBM 730 User Manual
Lochinvar Boiler CB 45 260 User Manual
Lucent Technologies Telephone Comcode 108239393 User Manual
Magnavox CD Player AZ241517 User Manual
Maytag Double Oven W10345638A User Manual
Maytag Range MER8880A User Manual
McIntosh Stereo Amplifier MC252 User Manual
Memorex Stereo System MKS5627 User Manual
Midland Radio Marine Radio 1001LWX User Manual