LG Electronics Air Conditioner PRCKD20E User Manual

LG  
LG  
AHU CONTROL KIT  
Owner's Manual  
Models: PRCKD20E  
PRCKD40E  
IMPORTANT  
• Please read this installation manual completely  
before installing the product.  
• Installation work must be performed in  
accordance with the national wiring standards  
by authorized personnel only.  
• Please retain this installation manual for future  
reference after reading it thoroughly.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Safety Precautions  
To prevent injury to the user or other people and property damage, the following instructions must be followed.  
I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is  
classified by the following indications.  
This symbol indicates the possibility of death or serious injury.  
WARNING  
This symbol indicates the possibility of injury or damage.  
CAUTION  
I Meanings of symbols used in this manual are as shown below.  
Be sure not to do.  
Be sure to follow the instruction.  
WARNING  
I Installation  
System air conditioner can  
only be installed by  
specialized service provider  
with air condition  
installation certifications.  
When moving or reinstalling  
the air conditioner, please  
contact the MULTI VTM AHU  
installation service provider.  
Do not disassemble, repair  
or reconfigure the product  
arbitrarily.  
• Inappropriate installation can  
cause leakage, fire and  
electric shock.  
• Inappropriate installation can  
cause leakage, fire and  
electric shock.  
• It can cause a fire and electric  
shock.  
Do not store or use  
flammable gas or volatile  
substance near the air  
conditioner.  
Do not bend or damage the  
power cable.  
For the electric  
construction, request for  
service to the distributor or  
the service center.  
• It can cause a fire or an  
electric shock.  
• It can cause a fire or problem  
to the product.  
Arbitrary disassembly or repair  
can cause a fire or an electric  
shock.  
Always ground the product.  
When installing the product,  
always install the electric  
circuit breaker and the  
exclusive switch.  
Do not use damaged circuit  
breaker or exclusive switch.  
• If the product is not grounded  
properly, it can cause an  
electric shock.  
• If they are not installed, it can  
cause a fire or an electric  
shock.  
• It can cause a fire or an  
electric shock.  
Owner's Manual 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
When opening the box or  
installing the product, be  
careful of any sharp objects.  
Use the fuse of rated  
capacity.  
For the product installation,  
request for service to the  
service center or the  
installation service provider.  
• It can cause an injury.  
• It can cause a fire or an  
electric shock.  
It can cause a fire , an electric  
shock, an explosion or an injury.  
The electric construction  
must be performed by an  
electrician for electric  
installation based on the  
installation manual and  
designated circuit diagram.  
Use designated installation  
material at the designated  
location for the product  
installation.  
Do not install the product  
outdoors.  
• Use of inappropriate wire and  
electric construction, can  
result in an electric shock or  
a fire. Technical standard for  
electric equipment  
I Operation  
Do not let water get inside  
(Controller) the product.  
Especially do not wash the  
product with water.  
Do not leave the product  
near a heating device.  
Do not change or expend  
the power cord arbitrarily.  
• It can cause an electric shock  
or a problem to the product.  
• It can cause a fire.  
• It can cause a fire or an  
electric shock.  
Use exclusive cable for the  
product.  
If you hear or smell a weird sound  
or odor, or if you see smoke from  
the product or if you experience a  
power outage, pull down the main  
power switch.  
Do not put any heavy  
objects on top of the power  
cable.  
• It can cause a fire or an  
electric shock.  
• If not, it can cause a fire or an  
electric shock.  
• It can cause a fire or an  
electric shock.  
Do not let the work or the  
user get on top of the  
product.  
Do not use any heating devices  
near the power cable.  
Do not turn off the power  
with the main power switch  
while the product is  
operating.  
• He or she can fall over to get  
injured.  
• It can cause a fire or an  
electric shock.  
• It can cause a fire or an  
electric shock.  
Do not operate the switch  
with wet hands.  
If you are not planning to use the  
product for a long period of time,  
pull down the main power switch.  
If the gas leaks, open the  
window to ventilate the  
room before operating the  
product.  
• It can cause a fire or an  
electric shock.  
• It can cause a fire or an  
electric shock.  
• It can cause an explosion or  
a fire.  
4 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Do not put containers with water on top of the product.  
• If the water spills over, it can cause a fire or an electric shock.  
CAUTION  
I Operation  
When installing the product,  
make sure to level the  
product.  
Do not install the product at  
a location where flammable  
gas is leaking.  
Do not carry the product by  
yourself.  
• It can cause vibration or  
leakage.  
• It can cause a fire or a  
problem to the product.  
• You can get injured by doing  
so.  
Owner's Manual 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Necessary sensor by operating mode  
Necessary sensor by operating mode  
Operating mode  
Necessary sensor  
Function  
- This runs indoor air conditioning.  
-
Initial external air inlet setting is 30% of the air  
supply during the air conditioning and this can be  
changed by the user. But, when the damper actuator  
is installed on AHU, the setting can be changed.  
SA temperature sensor  
RA temperature sensor  
Air conditioning  
- This runs the indoor heating.  
-
Initial external air inlet setting is 30% of the air  
supply during the heating and this can be changed  
by the user. But, when the damper actuator is  
installed on AHU, the setting can be changed.  
SA temperature sensor  
RA temperature sensor  
Heating  
-
-
This is the operating function to run indoor air  
conditioning by controlling multiple outdoor units by  
comparing the enthalpy of the indoor/outdoor air.  
During the power save operation, the operation switches  
between partial air conditioning operation (Controlling  
multiple outdoor units) and external air conditioning  
operation (Outdoor unit OFF, 100% external air flow).  
This is operating function is mainly used in between  
seasons. But if there is no OA temperature/humidity  
sensor and RA temperature/humidity sensor on the  
AHU, the power save operation cannot be selected.  
SA temperature sensor  
RA temperature sensor  
OA temperature/  
Power save  
humidity sensor  
Damper actuator  
-
-
-
This is the operating function to remove the indoor  
humidity when the humidity level indoor is excessive.  
During the dehumidifier operation, the set value is  
50%RH and the user cannot change this setting. But  
if there is no OA temperature/humidity sensor and  
RA temperature/humidity sensor on the AHU, the  
dehumidifier operation cannot be selected.  
SA temperature sensor  
RA temperature sensor  
OA temperature/  
Dehumidify  
humidity sensor  
-
This is the operating function to control the humidity to  
the set value by detecting the indoor humidity level.  
SA temperature sensor  
RA temperature sensor  
- This can be selected during heating operation.  
But if there is no humidifier/humidifying valve and  
RA temperature/humidity sensor on the AHU, the  
humidifier operation cannot be selected.  
Humidification  
-
This is the operating function to control the amount of  
external air flow so that the CO2 level is controlled  
within the set level by detecting the indoor CO2 level.  
SA temperature sensor  
RA temperature sensor  
CO2 sensor  
- The initial CO2 level is set to 1000ppm, and can  
be changed by the user.  
-
Auto ventilation  
This function operates when auto ventilator  
(Additional operation) is selected during air  
conditioning or heating operation. But if there is no  
CO2 sensor and damper actuator on the AHU, the  
auto ventilator operation cannot be selected.  
Damper actuator  
- When the mixing temperature during the heating  
operation is below the set value (5°C),  
preheating device automatically operates. The  
preheating device and mixing temperature  
sensor must be installed on AHU for this to  
operate automatically.  
SA temperature sensor  
RA temperature sensor  
Mixing temperature/  
humidity sensor  
Preheating  
6 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part Description  
Part Description  
Name and Function of Remote Controller  
1 OPERATION INDICATION  
SCREEN  
1
2
3
SET TEMPERATURE Button  
WIRELESS REMOTE  
CONTROLLER RECEIVER  
• Some products don't receive the  
wireless signals.  
VENTILATION Button  
OPERATION MODE SELECTION  
Button  
2
3
9
4
5
10  
11  
12  
4
5
6
13  
14  
15  
16  
6
7
SUBFUNCTION Button  
FUNCTION SETTING Button  
7
8
8 EXIT Button  
ON/ OFF Button  
9
10  
11  
12  
13  
14  
ROOM TEMPERATURE Button  
RESET Button  
FAN SPEED Button  
AIR FLOW Button  
RESERVATION/ TIME SETTING  
Button  
SETTING/ CANCEL Button  
Please attach the inform label inside of the door.  
Please choose proper language defend on your  
country.  
15  
16  
UP, DOWN, LEFT, RIGHT Button  
3/4/12/13 does not work.  
6 Additional operation button depends on the application of the sensor.  
Owner's Manual 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic operation of wired remote controller  
Basic operation of wired remote controller  
Press the Run/Stop button on the control  
part of the remote controller to start the  
operation.  
1
Press the Operation Selection button to  
set the operating mode (Heating/Cooling  
etc.).  
2
Press the Temperature Control button to  
set the desired temperature below the  
indoor temperature. (Based on air  
conditioning operation)  
3
(Example) Remote controller  
display window  
L Indoor  
L Desired  
temperature  
temperature  
During the initial operation, the  
desired temperature is  
automatically set below the indoor  
temperature.  
When you press the Run/Stop button  
during use, the operation will stop.  
4
8 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main function of wired remote controller  
Main function of wired remote controller  
Every time you press the Run/Stop  
button, the ON and OFF will be  
repeated.  
1
Every time you press the Operation Selection  
button, it will change in the order of Air  
Conditioner Dehumidifier Heater →  
Power Save Fan.  
2
There are operating modes  
that cannot be set depending  
on the applied sensor.  
<Air Conditioner>  
<Dehumidifier>  
<Heater>  
<Power Save>  
<Fan>  
Owner's Manual 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main function of wired remote controller  
Every time you press the Temperature  
Control button and the Up/Down button,  
the desired temperature will change.  
Air Conditioner/Power Save:  
3
18~30°C / Heater: 16~30°C  
Dehumidifier/Fan:  
Desired temperature cannot be changed  
When you press the Indoor Temperature  
button, the Return Temperature of AHU will  
be displayed for about 5 seconds.  
4
5
Current humidity / CO2 level  
To check the current humidity, press the Left’  
button when the indoor  
temperature is displayed and  
the indoor humidity will be  
displayed at Display C.  
Function  
Setting  
Code  
(Function set by code)  
* Code 01: Current humidity  
* Code 02: Current CO2 level  
To check the current CO2 level,  
press the Rightbutton when  
the indoor temperature is  
displayed and the current  
CO2 level will be  
: Current humidity  
: Current CO2 level  
(Example)  
displayed at Display C.  
<Current humidity: 50%>  
<Current CO2 level: 1500ppm>  
10 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplementary function of wired remote controller  
Supplementary function of wired remote controller  
Humidifier  
Press the Additional Operation  
button.  
1
2
When the Humidifier icon  
flashes in Display B, press the  
Set/Cancel button to start the  
humidifier.  
B
When you press the OK/CLEAR  
button one more time, the  
humidifier will stop.  
3
* Humidifier can only be set during heating  
operation.  
* Humidifier operation can only be used when the  
humidifier is installed.  
* The humidifier operation is controlled by the  
desired temperature set.  
Owner's Manual 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplementary function of wired remote controller  
Desired humidity control  
Press the Function Setting  
button.  
1
Set the Function Code of  
Display Cto 01.  
2
3
C
Press the Up/Down button to set  
the target humidity.  
Press the OK/CLEAR button to  
decide the desired humidity.  
4
* Desired humidity can be controlled in the range  
of 40~60% by 5% increment.  
* Default humidity is set to 50%.  
Display C: Desired humidity  
Function  
Setting  
Code  
(Function set by code)  
* Code 01: Current humidity  
: Desired humidity  
(Example)  
<Current humidity: 50%>  
12 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplementary function of wired remote controller  
Auto ventilaton  
Press the Additional Operation  
button.  
1
A
When the Auto icon flashes in  
Display A, press the OK/CLEAR  
button to start the Auto Ventilator.  
2
When you press the OK/CLEAR  
button one more time, the Auto  
Ventilator will be canceled and  
return to the previous operating  
condition.  
3
* Auto Ventilator function can only be set during  
the Air Conditioning/Heating operation.  
Owner's Manual 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplementary function of wired remote controller  
2
Desired CO level control  
Press the Additional Operation  
button.  
1
Set the Function Code of  
Display Cto 02.  
2
3
C
Press the Up/Down button to set  
the target CO2 level.  
Press the OK/CLEAR button to  
set the target CO2 level.  
4
* Desired CO2 level can be controlled in the range  
of 500~1500ppm by 100ppm increment.  
* Default humidity is set to 1000ppm.  
Display C: CO2 level  
Function  
Setting  
Code  
(Function set by code)  
* Code 02: Desired CO2 level  
: Desired CO2 level  
(Example)  
<Desired CO2 level: 500ppm>  
14 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Reservation function of wired remote controller  
Changing Current Time  
Keep pressing  
secs to enter Setting current  
time mode.  
button for 4  
1
2
3
Ex) Changing Current Time as  
'Monday / AM 10:20'.  
Press  
day.  
key to adjust the current  
Press  
key to move to AM/ PM setting  
mode (the 'AM/ PM segment will flash).  
Setting AM/ PM value by  
4
5
pressing  
button.  
Press  
button to move to 'Hour'  
setting mode. (the 'Hour' segment will  
flash)  
Setting Hour value by pressing  
button.  
6
Owner's Manual 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Press  
button to move to 'Minute'  
7
setting mode. (the 'Minute' segment will  
flash)  
Setting Minute value by pressing  
button.  
8
9
Press  
button to finish.  
In the process, press  
button to release and exit  
from setting mode.  
10  
(In case of exit with  
incomplete information, it will  
return to the previous setting )  
16 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Programming : Setting Simple Reservation  
In case of there is not any reservation setup on system, it is possible to make a SIMPLE reservation  
on indoor unit.  
Press  
Programming mode.  
(the  
button to enter the  
1
2
segment flashing)  
Ex) Setting Simple Reservation  
time as '3'.  
Press  
reservation time.  
button to adjust  
Press  
button to finish setting.  
3
4
Adjusting the reservation time after finish  
reservation setting will release the  
previous one.  
If the indoor is ON, we can make the reservation for turning OFF. In reserve, if the indoor is OFF,  
we can set the timer for turning ON. The reservation time is from 1 to 7 hours.  
Owner's Manual 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Programming : Setting ON Reservation  
This function is able to turn air conditioner ON after a setting time.  
Press  
button.  
1
2
3
Ex) Setting ON Reservation  
Time as 'AM 10:20'.  
Repeat pressing  
enter the ON reservation  
setting mode.  
button to  
(
segment flashing)  
Press  
setting.  
button to adjust AM/ PM  
Press  
button to Hour setting  
4
mode. When the Hour icon flash, please  
setting time.  
The setting range is within 1~12.  
Press  
button to shift to Minute  
5
6
setting mode. When the Minute icon  
flash, please setting minute the setting  
range is within 00~59.  
Press  
button to finish setting.  
18 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Programming : Setting OFF Reservation  
This function is able to turn air conditioner OFF after a setting time.  
Press  
button.  
1
2
3
Ex) Setting OFF Reservation  
Time as 'AM 10:20'.  
Repeat pressing  
enter the OFF reservation  
setting mode.  
button to  
(
segment flashing)  
Press  
setting.  
button to adjust AM/ PM  
Press  
button to shift to Hour  
4
setting mode. When the Hour icon flash,  
please setting time.  
The setting range is within 1~12.  
Press  
button to shift to Minute  
5
6
setting mode. When the Minute icon  
flash, please setting minute the setting  
range is within 00~59.  
Press  
button to finish setting.  
Owner's Manual 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Programming : Weekly Reservation  
The weekly reservation is active after setting current time  
Press programming button to enter  
the Programming mode. Repeat  
pressing button to select [Weekly  
reservation].  
1
(The segment will be flashed)  
Ex) Setting one action as below.  
- Day : TUE  
- ON Time : 11:30 AM  
- OFF Time : 12:30 PM  
Press left, right button to adjust the  
current day.  
2
Press up, down button to adjust the  
action number.  
3
Press right button to move to 'Hour'  
Part on ON Time section.  
(The 'Hour' segment will be flashed)  
4
Start Time Section  
Press up, down button to adjust the  
Hour on Start Time section.  
5
6
Press right button to move to  
'Minute' Part on Start time section.  
(The 'Minute' segment will be  
flashed)  
20 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Press up, down button to adjust the  
Minute on Start Time section.  
7
Press right button to move to 'Hour'  
Part on OFF Time section.  
(The 'Hour' segment will be flashed)  
8
9
Off Time Section  
Please refer the process from No.5  
to No.7 for setting OFF Time. It is  
same method.  
If you finish the setting, press  
10 setting/cancel button to complete  
programming.  
The under bar segment will be  
created, when it finished.  
Please refer the process from  
11 No.2 to No.10 for setting other  
day weekly program. It is same  
method.  
Press exit button to exit or system will  
12 automatically release without any input after  
25 seconds.  
<Note>  
Description of weekly reservation  
<Start Time Section>  
<Off Time Section>  
Action  
Start Time  
Front  
To  
Off Time  
Two actions per weekday can be programmed, in total 14 actions  
Owner's Manual 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reservation function of wired remote controller  
Programming : Holiday Reservation  
This function is to automatically stop the machine working on some days.  
Press  
button to enter the  
1
2
reservation setting mode.  
Repeat pressing  
enter the holiday reservation  
setting mode.  
button to  
(
segment flashing)  
Press  
holiday position.  
button to move to  
3
4
Press  
button to set or  
release a selected day as  
holiday or not.  
(the holiday is indicated  
with a underline)  
If there is any holiday from  
Monday to Sunday,  
segment on LCD will be  
displayed.  
5
Press the  
button to exit or if  
6
7
there is not any input, system  
will release any setting after 10  
seconds.  
It is possible to set the air conditioner  
OFF in every "holiday"  
( ex. 9:00, 10:00, 13:00 )  
22 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Setting function of wired remote controller installation  
How to start installation setting mode  
Press the Function Setting button for  
more than 3 seconds and the Code will  
be displayed on Display Cto enter the  
1
installation mode.  
C
When you now press the Function  
Setting button, the function code will  
change.  
2
Press the Up/Down button to change the  
setting.  
3
Press the Left/Right button to navigate  
through the items.  
4
Press the Set/Cancel button to complete  
the setting.  
5
Owner's Manual 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Setting function by code  
Code 10: Test run (AHU has no function)  
Code 11: Central control address setting  
Code 12: Damper opening setting  
Code 13: Remote controller  
Master/Slave setting  
Display C: Installation setting display  
Function  
Code  
Setting1  
Setting2  
24 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Central control address setting  
Enter the Installation Setting mode.  
1
2
Press the Function Setting button  
repeatedly to reach function  
code of 11.  
Flashes  
Press the Right button to  
move to Setting of 1.  
3
4
Flashes  
Press the Up/Down button  
to set the central control  
address.  
Central  
control  
address  
Press the Set/Cancel button  
to complete the central  
control address setting.  
5
* This is the function to set the central control  
address of AHU.  
Display C: Installation setting display  
Function  
Code  
Setting1  
Setting2  
Owner's Manual 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Damper opening setting  
Enter the Installation Setting mode.  
1
C
Repeatedly press the Function Setting  
button to reach function code of 12.  
2
Flashes  
Press the Right button  
to move to Setting of 1.  
3
4
Flashes  
Press the Up/Down button to set the value.  
Setting of 1for each mode is as follows.  
* Cooling mode [ 01(OA) /02(EA) / 03’  
(Mixing)]  
* Heating mode [ 04(OA) /  
05(EA) / 06(Mixing)]  
* Fan mode [ 07(OA) /  
08(EA) / 09(Mixing)]  
Cooling  
OA damper  
Heating OA  
damper  
Fan OA damper  
Display C: Installation setting display  
Function  
Code  
Setting1  
Setting2  
26 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Press the Right button to move to  
Setting of 2by each mode.  
5
Flashes  
C
Press the Up/Down button to select the  
damper opening.  
The damper opening that can be set is  
in the range of 1~91  
6
degrees.  
Air conditioning  
external damper  
opening of 40°  
Heating external  
damper opening  
of 40°  
Fan external  
damper opening  
of 40°  
Press the OK/CLEAR button to complete  
the setting.  
7
* This is the function to set the damper opening  
of AHU.  
* This applies only to the site where the damper  
actuator is installed.  
Display C: Installation setting display  
Function  
Code  
Setting1  
Setting2  
Owner's Manual 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting function of wired remote controller installation  
Remote control Master/Slave setting  
Enter the Installation Setting mode.  
1
2
3
C
Press the Function Setting button  
repeatedly to reach function code of 13.  
Flashes  
Press the Right button to move to  
Setting of 1.  
Flashes  
Press the Up/Down button to set the value.  
Setting value of 01is  
the Master and 00’  
4
is the Slave.  
Master  
Slave  
Press the OK/CLEAR button to  
complete the setting.  
5
* This is the function to set the mainly  
used remote controller.  
* You can set one remote controller as  
the Master and the rest as Slave.  
Display C: Installation setting display  
Function  
Code  
Setting1  
Setting2  
28 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manual operating mode  
Manual operating mode  
SA fan operation  
When you set the SA Fan Switch to ON,  
the SA fan will operate manually.  
1
4
5
SA fan operating LED will be turned on.  
2
3
3
When you set the SA Fan Switch to OFF,  
the SA fan will stop operating and can  
be operated automatically with the wired  
remote controller.  
2
1
* The SA switch of the control kit during AHU  
operation with the wired remote controller  
must be maintained at OFF condition.  
(Operating LED)  
(Selector switch)  
RA fan operation  
When you set the RA Fan Switch to ON,  
1
the RA fan will operate manually.  
RA fan operating LED  
SA fan operating LED  
Wired remote controller  
SA fan switch  
1
2
3
4
5
RA fan operating LED will be turned on.  
2
3
When you set the RA Fan Switch to  
OFF, the RA fan will stop operating and  
can be operated automatically with the  
wired remote controller.  
RA fan switch  
* The RA switch of the control kit during AHU  
operation with the wired remote controller  
must be maintained at OFF condition.  
Owner's Manual 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check before requesting for service  
Check before requesting for service  
When there is a problem with the product, check the following detail before requesting for service to  
the service center.  
Symptom  
Check  
Action  
The product does  
not work at all.  
* Is the main switch turned off? * Turn on the main power switch.  
* Is there a power outage?  
* Check the other electric appliances.  
(If the power works, try operating the product again.)  
* Request for service to the installation service provider or  
the service center.  
* The fuse inside the product  
can be disconnected.  
The cool air does not  
flow continuously.  
* Is the desired temperature set * Set the desired temperature to be lower than the indoor  
higher than the indoor  
temperature?  
temperature.  
* Is the product running in  
Dehumidifier/Power save  
mode?  
* Change the operating mode to air conditioning.  
I cannot set the  
* Is the schedule properly set? * Refer to the manual and try setting up the schedule again.  
scheduled operation.  
* Did you check the current  
time?  
* If the current time is incorrect, try setting again.  
AHU automatically  
goes off.  
* Is the OFF schedule set?  
* Check the remote controller and cancel the OFF schedule.  
30 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Test run  
Test run  
Self diagnosis function  
Error display  
I This function displays the self diagnosis and the type of error if identified.  
I For the error display, the applicable code is displayed on the 7 segment LED on the wired remote  
controller and AHU controller.  
I If there are 2 or more errors simultaneously, the codes are displayed in the order of occurrence.  
I Once you resolve the error, the error code will disappear.  
Error display method  
I The first display on the 7 segment display refers to the error code and the second part refers to the  
location information of the communication PCB address or sensor location. Refer to the following for  
details.  
Error type  
Display condition  
CH [Error code] 0  
Example of output  
CH30  
Detail description  
Error #3  
Basic error  
Communication PCB error CH [Error code] [Address]  
CH204  
Error #2 in communication PCB with  
address of #4’  
Sensor error  
CH [Error code] [Location]  
CH [Error code] [Address]  
CH1302  
Air supply temperature sensor error  
Error #173 on the outdoor unit connected  
to communication PCB with address of #4’  
Outdoor unit error  
CH17304  
* The address the communication PCB refers to the rotary switch number on the communication PCB.  
Location number  
Location name  
Applicable sensor type  
Temperature sensor, humidity sensor  
Temperature sensor, humidity sensor  
Temperature sensor, humidity sensor  
Temperature sensor  
01  
02  
03  
04  
05  
06  
RA  
SA  
OA  
Mixing  
Differential pressure  
Static pressure  
Differential pressure sensor  
Static pressure sensor  
* The above table shows the information of the attached location by sensor.  
Owner's Manual 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Test run  
Error display (AHU)  
I ##refers to the address information of the communication PCB.  
Display  
number  
Error item  
Cause of error  
Cause or error  
CH  
2
## Temperature sensor  
error at pipe inlet of  
indoor unit  
Communication PCB  
rotary switch number  
##  
Temperature sensor disconnection or short circuit at pipe inlet  
of indoor unit  
CH  
3
00 Communication error  
between wired remote  
controller and AHU  
controller  
No communication signal for more than 3 minutes from wired  
remote controller to the AHU controller  
-
CH  
CH  
4
5
## Communication error  
between AHU  
Communication PCB  
rotary switch number  
##  
No communication signal for more than 3 minutes from  
communication PCB to AHU controller  
controller and  
communication PCB  
## Communication error  
between  
Communication PCB  
rotary switch number  
##  
No communication signal for 5 minutes continuously from  
communication PCB to outdoor unit  
communication PCB  
and outdoor unit  
CH  
CH  
6
8
## Temperature sensor  
error on pipe outlet of  
indoor unit  
Communication PCB  
rotary switch number  
##  
Temperature sensor disconnection or short circuit on pipe  
outlet of indoor unit  
00 Emergency operation  
-
The operating status of the smoke control mode through smoke detector is displayed  
Temperature sensor (RA/SA/Mixing) disconnection/short  
circuit/misconnection or when the sensor value is in the error  
range  
CH 13 01 Temperature sensor  
RA  
error  
02  
04  
SA  
Mixing  
RA  
SA  
OA  
-
CH 14 01 Humidity sensor error  
Humidity sensor (RA/SA/OA) disconnection/short  
circuit/misconnection or when the sensor value is in the error  
range  
CO2 sensor disconnection/short circuit/misconnection or when  
the sensor value is in the error range  
02  
03  
CH 15 00 CO2 sensor error  
CH 16 05 Pressure sensor error  
Differential pressure  
Static pressure  
Pressure sensor (Differential pressure, static pressure) disconnection/short  
circuit/misconnection or when the sensor value is in the error range  
Air flow sensor (RA, SA) disconnection/short circuit/misconnection  
or when the sensor value is in the error range  
06  
CH 17 01 Air flow sensor error  
02  
RA  
SA  
32 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Test run  
Example of error  
Situation  
Error  
Pipe inlet temperature sensor error (Communication PCB rotary switch number: 01)  
Communication error between communication PCB and outdoor unit  
(Communication PCB rotary switch number: 05)  
SA duct temperature error  
CH  
CH  
2
5
01  
05  
CH  
CH  
13 02  
14 01  
RA duct humidity error  
Sequence of error  
* The occurrence of error is displays in the order of 1  
* Refer to page 43 for details of and 3 .  
2
3
on 7 segment.  
2
Refer to the MULTI V technical material for details on error code and checkpoints of the outdoor unit.  
Owner's Manual 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34 AHU CONTROL KIT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P/No.: MFL62171702  
Printed in Korea  
After reading this manual, keep it in a place easily accessible to the user for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Weather Radio WS 7048U User Manual
Land Pride Tiller RTA20 Series User Manual
Lanner electronic Network Card IAC F848 User Manual
Lumex Syatems Mobility Aid 1925A User Manual
Mackie Musical Instrument Onyx 1220 User Manual
Macsense Connectivity Stereo Amplifier 300PLUS User Manual
Magnadyne Network Router C LP User Manual
Magnavox TV DVD Combo 32MD359B User Manual
Marquis Telephone EUROMW5 User Manual
Microsoft Network Card MN 130 User Manual