Data Management Software
CA-S20w
Installation Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Before you use the CA-S20w software, we recommend that you thoroughly read this manual
as well as the instruction manuals of your PC and the instrument.
Formal designations of application software used in this manual
(Designation in this manual) (Formal designation)
Windows, Windows XP
Windows, Windows Vista
Windows, Windows 7
Excel
Microsoft Windows XP Professional Operating System
Microsoft Windows Vista Business Operating System
Microsoft Windows 7 Professional Operating System
Microsoft Excel
Visual Basic .NET 2003
Visual Basic .NET 2005
Visual Basic 2010
Microsoft Visual Basic .NET 2003
Microsoft Visual Basic .NET 2005
Microsoft Visual Basic 2010
Visual C++ .NET 2003
Visual C++ .NET 2005
Microsoft Visual C++ .NET 2003
Microsoft Visual C++ .NET 2005
Trademarks
• “Microsoft”, “Windows”, “Windows XP”, “Windows Vista”, “Windows 7” and “Excel” are
registered trademarks of Microsoft Corporation in the U.S.A. and other countries.
• “Intel” and “Pentium” are registered trademarks of Intel Corporation in the U.S.A. and other
countries.
Other company names and product names mentioned in this manual are the registered trademarks
or trademarks of their respective companies.
Notes on this manual
• No part of this manual may be reprinted or reproduced in any form or by any means without the
permission of Konica Minolta Sensing, Inc.
• The contents of this manual are subject to change without notice.
• Every effort has been made to ensure the accuracy of the contents of this manual. However,
should you have any questions or comments, or find an error or missing section, please contact
your local sales office.
• Konica Minolta accepts no responsibility for consequences resulting from failure to follow the
instructions outlined in this manual, the condition above notwithstanding.
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.1 System Requirements ................................................................................. 3
1.1.1 System Requirements ....................................................................................3
1.1.2 Compatible Instruments.................................................................................3
1.1.3 Language.........................................................................................................3
1.2 Software Installation ................................................................................... 4
1.2.1 Installation Method.........................................................................................4
1.2.2 Uninstallation Method....................................................................................7
1.3 Connecting the CA-2000 to PC.................................................................... 9
1.4 Installing Calibration Files......................................................................... 16
1.4.1 Installation Method.......................................................................................16
1.4.2 Notes on Calibration Files............................................................................17
1.4.3 Hierarchy of the Installed Files ....................................................................17
1.4.4 File Path Settings ..........................................................................................18
2
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.1 System Requirements
1.1.1 System Requirements
OS
Windows XP Professional 32-bit Service Pack 3, 64-bit Service Pack 2
Windows Vista Business 32-bit, 64-bit
Windows 7 Professional 32-bit, 64-bit
(English, Japanese and Korean versions
For Windows XP professional 64-bit, English and Japanese versions only)
Equivalent to Pentium 4, 2.8GHz or better
1024 MB or more
CPU
Memory
Hard disk drive
At least 80 MB of available disk space is required on the system drive (drive where the OS
is installed).
To install the calibration data, the following disk space is required for each lens:
For a standard lens: approximately 540 MB
For a wide angle lens: approximately 470 MB
For a telephoto lens: approximately 1.3 GB
To save measurement data on the hard disk, you need to reserve the following additional
space on the hard disk:
For example, approximately 110 MB is required to save 10 pieces of measurement data
with 980 × 980 resolution.
(Up to 1,000 pieces of measurement data can be saved.)
About 1 MB is required for configuration files such as the spot setting file and
measurement condition file.
For protection in the event of forced termination, the CA-S20w retains measurement data
in the temporary work area until the data is saved by the user. Temporary data will be
stored in the following folder (assuming that the system drive is Drive C):
C:\Document and Settings\<login user name>\Local Settings\Temp\mcl
When the file is saved, the temporary data is deleted. The data, however, is retained
temporarily until it is saved on the hard disk, or until you exit the CA-S20w normally.
Consequently, when you plan to measure a large amount of data, you need to reserve a
certain amount of space for the temporary evaluation area (11 GB or more when
measurement at 980 × 980 resolution is performed 1,000 times). This must be considered
before starting continuous measurement.
Excel 2003 (required for continuous measurement with the automation function)
Display
Other
Display hardware capable of displaying 1280 × 1024 pixels / 65,536 colors (High Color:
16-bit color) or better
1 CD-ROM drive Required for installation
1 DVD-ROM drive Required for installation of calibration data
(As a substitute for the two drives above, 1 combo drive capable of reading CD-R media
and DVD-R media can be used.)
1 USB port (Ver. 2.0, type A connector) Required for instrument
Excel 2003 (when the OS is Windows XP), Excel 2007 (when the OS is Windows Vista or
Windows 7) or Excel 2010 (when the OS is Windows 7)
(required for continuous measurement with the automation function)
1.1.2 Compatible Instruments
Instrument
CA-2000
1.1.3 Language
Display language
English, Japanese (Select one during installation)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.2 Software Installation
Install the software before connecting the CA-2000 to the PC.
The software is provided on a CD-ROM and the calibration data on a DVD-ROM. A CD-ROM/DVD-
ROM drive is required to use them.
If an older version of this software has been installed, you need to uninstall it before installing this
version.
Note
If there are any measurement data or setting files stored in the installation folder, be sure to move
them to a different folder before uninstalling the older version.
For the uninstallation procedure, refer to page 7.
To install the software, be sure to log on to the PC as an administrator.
Tip
If you selected a user other than a user with administrator privileges, you cannot install the software.
1.2.1 Installation Method
1. Insert the software CD into the CD-ROM/DVD-ROM drive.
When the Select Language dialog box appears, select the language to install and click the OK button.
The procedure below assumes that English is the selected language.
The InstallShield Wizard appears.
2. Click the Next button.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
3. Read the software license agreement, select ‘I accept the terms in the license agreement’, and click
the Next button.
4. Check the destination folder.
Click the Next button.
To install to a different folder, click the Change button and specify the folder.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
5. Click the Install button.
Installation starts.
6. Click the Finish button.
Installation is complete.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.2.2 Uninstallation Method
1. In Windows, select Start - Control Panel - Add or Remove Programs.
In the Add or Remove Programs dialog box, a list of currently installed programs is displayed.
2. Select ‘CA-S20w’ from the list and click the Remove button.
3. In the Add or Remove Programs dialog box, click the Yes button.
The uninstallation program is executed.
4. Follow the prompts to complete the uninstallation process.
Tip
See pages 17 and 18 for calibration files and folders.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
Then, for Windows Vista or Windows 7, follow the procedure below to uninstall the driver of the CA-
2000.
5. From the Start menu, select Control Panel. When ‘Classic View’ is displayed in Windows Vista,
select ‘Control Panel Home’.
6. From the ‘System and Maintenance’ menu (Windows Vista) or ‘System and Security’ menu
(Windows 7), select ‘System’.
7. Select ‘Device Manager’ under Tasks.
8. Right-click ‘KMSE 2D Analyzer CA-2000’ in ‘Universal Serial Bus controllers’, and click the
Uninstall button.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.3 Connecting the CA-2000 to PC
Install the software before connecting the CA-2000 to the PC.
1.3.1 Connecting the CA-2000 for the first time (Windows XP)
1. After turning on the CA-2000’s power, connect the USB cable to the PC and the CA-2000.
The Found New Hardware Wizard dialog box appears. Wait a while.
2. Select ‘No, not this time’ and click the Next button.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
3. Select ‘Install the software automatically’ and click the Next button.
When your OS is Windows XP Professional 64-bit, you need to specify the source of the
installation. Select “ca2000.inf” in the “Driver” folder in the software CD and click the Next button.
The Hardware Installation dialog box appears.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
4. Click the Continue Anyway button.
5. Click the Finish button.
Installation is complete.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.3.2 Connecting the CA-2000 for the first time
(Windows Vista)
1. After turning on the CA-2000’s power, connect the USB cable to the PC and the CA 2000.
• The Found New Hardware dialog box appears.
2. Click ‘Locate and install driver software’. When the dialog box which confirms User Account
Control appears, select ‘Continue’.
3. Insert the software CD into the drive and click the Next button.
4. Click the Close button.
• The installation of the driver software is complete.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.3.3 Connecting the CA-2000 for the first time (Windows 7)
1. Insert the software CD into the drive. After turning on the CA-2000’s power, connect the USB cable
to the PC and the CA-2000.
• The installation of the device driver should start automatically.
2. Select the icon showing Installing device driver software from the taskbar.
3. When the Device Software Installation dialog box appears, click ‘Skip obtaining driver software
from Windows Update’.
4. When the confirmation window appears, click the Yes button.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
5. Wait for the screen below to appear and click the Close button.
• Please wait for a while as this may take several minutes.
6. Right click on the ‘Computer’ from the Start menu and select ‘Properties’.
• The screen below will appear after clicking ‘Device Manager’ on the left of the Control Panel.
7. Right click on ‘k364usb’ and select ‘Update Driver Software’.
8. Click ‘Browse my computer for driver software’.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
9. Designate the driver folder in the software CD and click the Next button.
(Example) In the case of CD-ROM in D drive.
D:\Driver
10.Click the Close button.
• The installation of the driver software is complete.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.4 Installing Calibration Files
The CA-2000 you have purchased comes with a calibration data DVD for each lens you selected at time
of purchase.
All items on the DVD provided must be installed in order for the CA-2000 to make measurements.
To install the calibration files, be sure to log on as an administrator to the PC.
Note
If you selected a user other than a user with administrator privileges, you cannot install the
calibration files.
Note
If you are installing calibration files for the first time, you need to run the CA-S20w as an
administrator. To do this, right-click ‘CA-S20w’ from the program menu and select ‘Run as
administrator’.
1.4.1 Installation Method
1. Start the software.
The Connect CA-2000 dialog box appears.
2. Select ‘Disconnect’ and click the OK button.
3. Select Tool - Install calibration files from the menu.
4. When the Insert calibration-DVD message dialog box appears, insert the calibration data DVD in
the drive and click the OK button.
Insert the disk in the drive recognized first.
After inserting the disk, the message may be displayed several times. Click the OK button each time
it appears.
Installation starts when the disk is recognized. Installation takes about 3 minutes.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
This operation must be performed for each disk.
The drive name may be different
depending on your PC usage
environment.
Tip
If the disk is not recognized, check the file path of the drive for the calibration disk in “File Path
Settings” below.
1.4.2 Notes on Calibration Files
During measurement, or when connecting the PC and CA-2000, the information in the installed
calibration files is compared with the information stored in the CA-2000.
You will not be able to connect, or you will not be able to select some lenses, if the calibration files are
found to be out of date (because more recent calibration files exist due to re-calibration after purchase).
Delete the folder containing the out-of-date files and install more recent calibration files. See the next
section for folders.
1.4.3 Hierarchy of the Installed Files
CA-S20w and the calibration files are installed in the following hierarchy.
When the OS is Windows XP
When the OS is Windows Vista or Windows 7
C: Program Files
KONICAMINOLTA
CA-S20w
C: Users
“Login user name” folder
AppData
1001006
Local
VirtualStore
Program Files
KONICAMINOLTA
CA-S20w
The calibration files
are installed in the
folder with the
same name as the
CA-S2000’s serial
number.
1001006
The calibration files
are installed in the
folder with the
same name as the
CA-S2000’s serial
number.
CA-S20w.exe
CA-S20w.exe
The calibration files are installed for each serial number (See page 9 “Status Bar” in the CA-S20w Instruction
Manual.) of the CA-2000 to use.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
1.4.4 File Path Settings
You can change the storage location of measurement files and calibration data and the file path of the
drive for the calibration disk.
1. Select Tool - File Path from the menu.
The Option File Path dialog box appears.
2. Change each file path as necessary.
Click the Browse button to specify the existing file path.
In the ‘Save folder’ field, do not choose a location in the root directory of the hard drive (such as
C:\) but specify a folder.
For ‘Calibration data’, specify the folder one level higher than the folder with the serial number
(‘CA-S20w’ in the figure above).
3. Click the OK button.
If the file path setting is wrong, the Option File Path dialog box appears again. Check the file path
and specify it correctly.