Kodak Printer Accessories CIS 201 User Manual

March 2000 CIS-201  
CURRENT INFORMATION SUMMARY  
Printer Conversion to  
KODAK EKTACOLOR Edge 8 and  
EKTACOLOR ROYAL VIII Papers  
in densitometer performance when setting up their printers  
for the new papers.  
KODAK EKTACOLOR Edge 8 and ROYAL VIII Papers  
incorporate new image-forming components to deliver  
improved colors. These new papers are designed so that a  
visually neutral patch will result in approximately balanced  
red, green, and blue densities when measured with  
densitometers that conform to ANSI Status A responses.  
Some densitometers that do not conform to ANSI Status A  
responses may produce non-matched red, green, and blue  
densities for a neutral patch on these new papers. Labs that  
use these non-Status A densitometers must compensate for  
the differences in densitometer performance when they set  
up printers for the new papers.  
When you are ready to convert to KODAK  
EKTACOLOR Edge 8 or ROYAL VIII Paper, follow the  
procedure below to determine how your densitometer  
performs. Once you’ve determined the densitometer  
performance, choose the appropriate compensation  
procedure (if one is necessary).  
To Determine If Compensation Is Required  
1. Print your “Normal” Printer Control Negative on  
EKTACOLOR Edge 7 or ROYAL VII Paper at the aim  
density.  
2. With EKTACOLOR Edge 8 or ROYAL VIII Paper,  
balance to match the density readings from Step 1.  
WHY DOES THIS HAPPEN?  
Densitometers fall into two classes: (1) for analytical use and  
(2) for comparative use.  
3. Compare the two prints. If the prints match visually,  
follow normal printer paper conversion procedures (see  
your printer manual). If the print from Step 2 appears  
cyan, the densitometer is reading EKTACOLOR Edge 8  
or ROYAL VIII Paper differently. You will need to  
follow one of the compensation procedures below.  
Analytical densitometers conform to an ANSI standard  
called “Status A.” Status A densitometers correlate colors  
similarly to the human eye through a wide color and density  
range. These densitometers will give similar readings for  
KODAK EKTACOLOR Edge 7/ROYAL VII and  
EKTACOLOR Edge 8/ROYAL VIII Papers if the prints  
appear visually matched.  
Note: Compensation procedures have not been prepared  
for equipment that produces matched prints in Step 3 of  
the procedure above. If your printer is not included in  
the list below, follow your equipment manufacturer’s  
paper setup instructions.  
Comparative densitometers are designed to match prints  
to a specific density. They are not intended for use over a  
wide range of densities and colors, and they do not see colors  
as the human eye does. These densitometers are often used  
in printing systems as a part of a minilab or a high-speed  
printer. They produce consistent measurements in the ranges  
used for printer setup. However, with KODAK  
EKTACOLOR Edge 8 or ROYAL VIII Paper, they do not  
measure the neutral aim patches as neutral. For example, an  
aim print on EKTACOLOR Edge 8/ROYAL VIII Paper  
measures 0.80 red, 0.80 green, and 0.80 blue with a Status A  
densitometer. The same print may measure 0.70 red,  
0.80þgreen, and 0.80 blue with a comparative densitometer.  
COMPENSATION PROCEDURES  
If you have one of the printers in the following list, choose  
the appropriate procedure:  
Compensation Procedure for NORITSU 1401/1501  
Printers  
Compensation Procedure for NORITSU 1801 Micro  
Printer  
Compensation Procedure for NORITSU 1701/1702  
Printers (without NOUS Scanner)  
Compensation Procedure for NORITSU 901, 1001,  
1201, and 1202 Printers  
Compensation Procedure for COPAL Minilab, Models  
1B, 1C, 5C, 5C II, 5L, 5S  
WHAT DOES THIS MEAN FOR LABS?  
New EKTACOLOR Edge 8 and ROYAL VIII Papers  
provide many performance advantages. But when they are  
used with densitometers that do not conform to Status A  
specifications, results may vary. Labs that use these  
non-Status A densitometers must compensate for differences  
Compensation Procedure for AGFA MSP Printers  
Compensation Procedure for AGFA MSC Printers  
Compensation Procedure for GRETAG Masterlab  
Compensation Procedure for GRETAG Masterflex  
©Eastman Kodak Company, 2000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Morning Setup channel will use the new paper, you  
would input the following:  
Ringaround Method  
This method does not require a densitometer.  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
00-07 (N)  
Range of channels  
Input corrections  
calculated above.  
0.0Y -0.7M 1.5C -0.4D Y/N  
This Channel Balance correction will be made to  
channels 00, 01, 02, 03, 04, 05, 06, and 07.  
Note: If the channels that will use the new paper are not  
in a continuous range, you will have to make multiple  
corrections to avoid altering channels that use other  
paper types.  
Keep the negative and prints in a safe place. Record the  
paper channel (00 to 59) and Morning Setup channel (11  
to 84) used to print this test.  
Also record the channels that will be using the new  
paper. Only these channels will be corrected.  
8. Repeat Steps 3 through 7 until the Normal test print  
matches the Normal reference print within one button.  
When the test print matches the reference print, you can  
proceed to “Setting the Paper Slope.”  
Note: If this paper size/surface will also be used for  
Morning Setup, you must include channel 00 in the  
corrections.  
2. When you are ready to convert to the new paper, load it  
into the printer.  
Setting the Paper Slope  
After matching the Normal test and Normal reference prints,  
make test prints from the “Under” and “Over” Printer Setup  
Negative. Make sure to use the same channel that was used  
to make the Old-Paper Reference Prints. If the Under and  
Over test prints match the reference prints, the conversion is  
complete.  
3. Print a one-button ringaround, using the same test  
negative you used to make the reference prints in Step 1.  
You must use the same paper channel and Morning  
Setup channel as before. Print a ringaround from the  
Normal negative as follows:  
If the test and reference prints do not match, proceed as  
follows:  
1. Calculate the corrections from the density readings in  
the same way you did for the normal test and reference  
prints.  
To print a one-button ringaround:  
MODE 32 (AUTO RINGAROUND)YESAUTO  
RINGAROUND 0(0-2:COLOR 3:DEN)1YES  
4. When the prints are processed, select the print that is the  
closest match to the reference print. Apply the  
correction as indicated by the backprint. It will appear in  
this order:  
2. Apply the slope correction to the paper channels that  
will use the new paper by using the channel shift  
command:  
Key: Print Order Channel  
Data: 236 45 0111  
Y
N
M
N
C
N
D
N
CF  
2
To correct the Under slope:  
MODE 33 (CH SHIFT)YESCH BALANCE  
SHIFTNOCH UNDER  
SHIFTD-INYESSET UNDER  
NEGYESinput correction  
This is a typical example. Some printers may have  
different CVP settings. If the backprint is switched off  
or not legible, keep the prints in order and mark the  
correction on the back. The prints are printed in this  
order: -Y, +Y, -M, +M, -C, +C, -D, +D, N.  
To correct the Over slope:  
MODE 33 (CH SHIFT)YESCH BALANCE  
SHIFTNONOCH OVER  
SHIFTD-INYESSET OVER  
NEGYESinput correction  
5. Identify the channels that are currently using the old  
paper. These channels will all require the same  
correction.  
You do not include CH 00 in the channel range, because  
slope is switched off for CH 00.  
Note: If the Master Balance or Morning Setup channel  
will use the new paper, you must include CH 00 in the  
Channel Balance Shift.  
3. Repeat the steps until the Under and Over test prints  
match the Under and Over reference prints to within one  
button.  
6. Apply the balance correction to the paper channels  
using this paper size:  
When Channel 00 is set up for EKTACOLOR Edge 8/  
ROYAL VIII Paper, you must make a new Morning Setup  
reference print to use in place of the old Edge 7/ROYAL VII  
Paper reference print. When you have achieved the final  
balance, make a print on CH 00 and store it to use for  
Morning Setup.  
MODE 33 (CH SHIFT)YESCH BALANCE  
SHIFTD-INYES  
7. Determine which channels use this paper. For example,  
to input the correction if the -1M print is closest to the  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
reference print, and if you use the same paper for  
channels 10, 11, 12, 13, 14, and 15, you would input:  
When Channel 00 is set up for EKTACOLOR Edge 8/  
ROYAL VIII Paper, you must make a new Morning Setup  
reference print to use in place of the old Edge 7/ROYAL VII  
Paper reference print. When you have achieved the final  
balance, make a print on CH 00 and store it to use for  
Morning Setup.  
10-15 (N)  
Range of channels  
Input corrections  
calculated above.  
Press arrow keys to  
move cursor.  
0.0Y -1.0M 0.0C 0.0D Y/N  
Compensation Procedure for NORITSU 1801  
Micro Printer  
Follow this procedure to convert to KODAK EKTACOLOR  
Edge 8/ROYAL VIII Paper from KODAK EKTACOLOR  
Edge 7/ROYAL VII Paper. This procedure permits  
conversion without the use of the printer’s built-in  
densitometer.  
The Channel Balance correction will be made to  
channels 10, 11, 12, 13, 14, and 15.  
Note: If the Master Balance or Morning Setup channel  
will use the new paper, you must include CH 00 in the  
Channel Balance Shift. For example, if channels 01, 02,  
03, 04, 05, 06, and 07, and the Master Balance or  
Morning Setup channel will use the new paper, you  
would input the following:  
Before You Begin  
1. Save or record your current setup information. This  
procedure will erase any corrections that may have been  
entered.  
00-07 (N)  
Range of channels  
Input corrections  
calculated above.  
0.0Y -1.0M 0.0C 0.0D Y/N  
2. Ensure that the equipment is correctly set up to lab aims.  
This procedure allows crossover to the new paper  
without noticeable differences in print quality.  
This Channel Balance correction will be made to  
channels 00, 01, 02, 03, 04, 05, 06, and 07.  
Note: If the channels that will use the new paper are not  
in a continuous range, you will have to make multiple  
corrections to avoid altering channels that use other  
paper types.  
Setup Procedure  
Before your supply of EKTACOLOR Edge 7/ROYAL VII  
Paper runs out, be sure that you have a Morning Setup  
reference print on Edge 7/ROYAL VII Paper. If none is  
available, perform a Morning Setup to make a reference print  
on the old paper. Then do this:  
8. Print a half-button ringaround to fine-tune the  
correction:  
1. Install the EKTACOLOR Edge 8/ROYAL VIII Paper  
magazine.  
MODE 32 (AUTO RINGAROUND)YESAUTO  
RINGAROUND 0(0-2:COLOR 3:DEN)0YES  
2. Perform a Morning Setup on the new paper, and process  
the print.  
9. Repeat the steps above to match the channels to the  
reference prints on Edge 7/ROYAL VII Paper. When  
the Normal test print matches the Normal reference  
print within one button, you can proceed to “Setting the  
Paper Slope.”  
3. Calculate a correction to produce a visual match  
between the test print on Edge 8/ROYAL VIII Paper  
and the reference print on Edge 7/ROYAL VII Paper as  
shown in the example. Use an X-Rite or similar  
Setting the Paper Slope  
densitometer that has Status A filters (e.g., an X-Rite  
881 or 891 densitometer) to measure the print densities.  
After matching the Normal test and Normal reference prints,  
follow the same procedure you did for balance.  
1. Print a ringaround from the Under and Over Printer  
Setup Negatives.  
Example  
Densitometer Readings—  
Reference and Test Prints  
2. Apply the slope correction to the paper channels that  
will use the new paper by using the channel shift  
command:  
Cyan  
75  
Magenta  
Yellow  
73  
REFERENCE  
TEST  
80  
87  
-7  
90  
73  
To correct the Under slope:  
Difference  
-15  
0
MODE 33 (CH SHIFT)YESCH BALANCE  
SHIFTNOCH UNDER  
SHIFTD-INYESSET UNDER  
NEGYESinput correction  
Note: To obtain the difference, subtract the test-print  
densities from the reference-print densities.  
Add the Cyan + Magenta + Yellow difference values to  
obtain an overall density reading. Then divide by 50 to  
obtain the density correction:  
To correct the Over slope:  
MODE 33 (CH SHIFT)YESCH BALANCE  
SHIFTNONOCH OVER  
SHIFTD-INYESSET OVER  
NEGYESinput correction  
Density  
Correction  
Difference -15 -7  
0
=
-22 -22 / 50 =  
-0.4  
You do not include CH 00 in the channel range, because  
slope is switched off for CH 00.  
4
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Divide the Cyan, Magenta, and Yellow difference  
values by 10 to obtain the color correction:  
8. Measure the -D, N, and +D test prints, but DO NOT  
enter the correction. Record the correction on a piece of  
paper; then press NO.  
Color Correction  
-1.5  
-0.7  
0.0  
9. Press MODE, then C-DATA. Input the correction from  
Step 8 into 00 CH BALANCE; then press YES.  
The correction for this example is -1.5 Cyan,  
-0.7 Magenta, 0.0 Yellow, and -0.4 Density.  
Repeat Steps 7 through 9 until no further correction is  
required. Remove the Setup Filter. The NORMAL balance is  
complete.  
4. When the message SET REFERENCE is displayed,  
press NO. Enter the correction, and then press YES.  
5. Press YES to reprint the test.  
Setting the Paper Slope (Under)  
6. Repeat Steps 2 through 5 until the test print on Edge 8/  
ROYAL VIII Paper matches the reference print on  
Edge 7/ROYAL VII Paper.  
If the Under slope requires adjustment, follow this  
procedure:  
1. Select the channel that will be most commonly used for  
the new paper. Press MODE, then AUTO SETUP. Then  
press NO until AUTO SETUP appears. Select “0” for  
“print,” press YES, and enter the number for “U”  
(Under). Then press YES.  
7. Keep the final test print as your new reference print for  
Edge 8/ROYAL VII Paper.  
8. Print customer negatives to verify print quality.  
2. Set the “Under” Printer Setup Negative in the negative  
mask, and press YES and YES. When NEXT SETUP  
appears, press NO.  
Compensation Procedure for NORITSU 1701/  
1702 Printers (without NOUS Scanner)  
Follow this procedure to convert to KODAK EKTACOLOR  
Edge 8/ROYAL VIII Papers from KODAK EKTACOLOR  
Edge 7/ROYAL VII Papers.  
3. Measure the -D, N, and +D test prints, but DO NOT  
enter the correction. Record the correction on a piece of  
paper. Then press NO.  
Normal Correction  
4. Enter the correction determined in Step 3 by pressing  
MODE, SETUP, and NO until CH UNDER SHIFT Y/N  
appears.  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
5. Press YES, place the “Under” Printer Setup Negative in  
the negative mask, and press YES. (If the Under  
negative is not in the negative mask, an NG error will  
occur and the correction will not be made.)  
6. Press D-IN and input the range of channels that will be  
using the new paper (do not include channel 00). Enter  
the correction, and press YES.  
2. When you are ready to convert to the new paper, load it  
into the printer. Then press MODE, AUTO SETUP, and  
NO. Select “0” to print a test. Press YES and place the  
“Normal” Printer Setup Negative in the negative mask.  
Press YES, YES, and NO. When the test prints leave the  
processor, select “measure,” PAP.  
Repeat Steps 1 through 6 until no further correction is  
required. Setup of the Under slope is complete.  
Setting the Paper Slope (Over)  
3. Enter the readings from the print labeled “Old-Paper  
Reference Print—Normal” into the Reference Aim.  
Then press D-IN and YES. Then press NO.  
If the Over slope requires adjustment, follow this procedure:  
1. Select the channel that will be most commonly used for  
the new paper. Press MODE, then AUTO SETUP. Then  
press NO until AUTO SETUP appears. Select “0” for  
“print,” then YES. Enter the number for “O” (Over);  
then press YES.  
4. Enter the readings from the -D, N, and +D test prints  
into the P-BAL correction mode. Press D-IN and YES.  
The correction will be made to the paper balance for the  
new paper.  
2. Set the “Over” Printer Setup Negative in the negative  
mask, and press YES and YES again. When NEXT  
SETUP appears, press NO.  
5. Select “0” to make another print, and then YES. Select  
“Normal” and press YES. Place the “Normal” Printer  
Setup Negative in the negative mask, and press YES and  
YES again. Then press NO.  
3. Measure the –D, N, and +D test prints, but DO NOT  
enter the correction. Record the correction on a piece of  
paper, and then press NO.  
6. Repeat Steps 2, 4, and 5 (do not repeat Step 3) until no  
further correction is required.  
4. Enter the correction determined in Step 3 by pressing  
MODE, SETUP, and NO until CH OVER SHIFT Y/N  
appears.  
Perform a Morning Setup, and carefully follow these  
instructions:  
7. Press MODE, AUTO SETUP, and YES. Insert the  
Setup Filter, press D-IN, and then YES. After the  
Change of Light has been completed, press YES.  
5. Press YES, and place the Over negative in the negative  
mask. Press YES. (If the Over negative is not in the  
negative mask, an NG error will occur and the  
correction will not be made.)  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Press D-IN and input the range of channels that will be  
using the new paper (do not include channel 00). Enter  
the correction, and press YES.  
Note: To obtain the difference, subtract the test-print  
density from the reference-print density.  
4. To calculate the correction, add the cyan, magenta, and  
yellow difference values to obtain an overall density  
reading. Divide by 5 to obtain the density correction.  
Repeat Steps 1 through 6 until no further correction is  
required. Setup of the Over slope is complete.  
Density  
Correction  
Compensation Procedure for NORITSU 901,  
1001, 1201, and 1202 Printers  
Difference -15 -7  
0
=
-22 -22 / 5 =  
-.4  
Follow this procedure to test KODAK EKTACOLOR  
Edge 8/ROYAL VIII Papers when converting from KODAK  
EKTACOLOR Edge 7/ROYAL VII Papers, and to set up  
your printer for the new paper.  
Divide the cyan, magenta, and yellow difference values  
by 10 to obtain the color correction.  
Color Correction  
-1.5  
-.7  
.0  
Testing the New Paper  
If the printer uses only one type of paper, follow Method 1.  
If it uses more than one type, follow Method 2.  
The correction for this example is -1.5 Cyan,  
-.7 Magenta, .0 Yellow, and -.4 Density.  
5. Identify the channels that are using the old paper, and  
record them; these channels will all require the same  
correction.  
Method 1:  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
Note: If the Master Balance or Morning Setup channel  
will use the new paper, you must include CH 00 in the  
Channel Balance Shift. For example, if the new paper is  
used in channels 01, 02, 03, 04, 05, 06, 07, and the  
Master Balance or Morning Setup channel, you would  
enter the following:  
2. When you are ready to convert to the new paper, load it  
into the printer and perform a Morning Setup procedure.  
00-07  
(N)  
Y/N  
-0.0 Y  
-.7 M  
-1.5 C  
-.4 D  
3. Print the Printer Setup Negative, “Under,” “Normal,”  
and “Over” on the channel that will be most commonly  
used for the new paper. If the test prints match the  
reference prints, the paper change is complete. If the test  
prints do not match the reference prints, proceed to  
“Setting the Paper Slope.”  
This Channel Balance correction will be made to  
channels 00, 01, 02, 03, 04, 05, 06, and 07.  
6. Input the correction into the Channel Balance Shift as  
follows:  
a. While pressing MODE, press SETUP, and then  
press NO until CH BALANCE SHIFT Y/N  
appears.  
Method 2:  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
b. Press D-IN. Press YES.  
c. To input the sample correction above for channels  
10, 11, 12, 13, 14, and 15, enter the following:  
10-15  
-.7 M  
(N)  
Y/N  
0.0 Y  
-1.5 C  
-.4 D  
2. When you are ready to convert to the new paper, load it  
into the printer. Make a print from the “Normal” Printer  
Setup Negative on the new paper. Make sure to use the  
same channel as in Step 1. Label the print “New-Paper  
Test Print—Normal.”  
Press the arrow keys to move the cursor.  
Press the YES key. The Channel Balance correction will  
be made to channels 10, 11, 12, 13, 14, and 15.  
3. Measure the Normal reference print and the print  
labeled “New-Paper Test Print—Normal,” and record  
the readings. See Example 1.  
Repeat Steps 2 through 6 until the Normal test print  
matches the Normal reference print. When the Normal test  
print matches the Normal reference print, you can proceed to  
“Setting the Paper Slope.”  
Example 1  
Densitometer Readings—Normal Reference  
and Normal Test Prints  
Setting the Paper Slope  
After matching the Normal test and Normal reference prints,  
make test prints from the “Under” and “Over” Printer Setup  
Negatives. Make sure to use the same channel you used to  
make the reference prints. If the Under and Over test prints  
match the reference prints, the paper change is complete.  
Cyan  
75  
Magenta  
Yellow  
73  
REFERENCE  
TEST  
80  
87  
-7  
90  
73  
Difference  
-15  
00  
6
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If the Under and Over test prints do not match the reference  
prints, proceed as follows:  
Compensation Procedure for COPAL Minilab,  
Models 1B, 1C, 5C, 5C II, 5L, 5S  
1. Use the method described in Step 4, above, to calculate  
a correction to make the Under and Over test prints  
match the Under and Over reference prints.  
Follow this procedure to test KODAK EKTACOLOR  
Edge 8/ROYAL VIII Papers when converting from KODAK  
EKTACOLOR Edge 7/ROYAL VII Papers, and to set up  
your printer for the new papers.  
Ensure that the Master Balance is on aim before making  
any changes to printer balance. Back up current channel data  
(see Step 5 under “Setting the Paper Slope”).  
2. Input the Under correction into the Channel Under Shift  
in the following way:  
While pressing MODE, press SETUP. Then press NO  
until CH UNDER SHIFT appears. Determine which  
channels use this paper. Do not include channel 00 in  
this correction. Place the Under negative into the  
negative mask, press D-IN, and enter the correction  
required for the Under slope. To input the sample  
correction from above for channels 10, 11, 12, 13, 14,  
and 15, enter:  
Testing the New Paper  
If the printer uses only one type of paper, follow Method 1.  
If it uses more than one type, follow Method 2.  
Method 1:  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
10-15  
-.7 M  
(U)  
Y/N  
0.0 Y  
-1.5 C  
-.4 D  
(If the Under negative is not in the negative mask, an  
NG error will occur and the correction will not be  
made.)  
2. When you are ready to convert to the new paper, load it  
into the printer and do a Master Balance Test. When the  
Master Balance Test is on aim, the “Normal” has been  
set up.  
3. Press the YES key. The Channel Under Balance  
correction will be made to channels 10, 11, 12, 13, 14,  
and 15.  
4. Input the Over correction into the Channel Over Shift in  
the following way:  
3. The new paper may be different in “Under” and “Over”  
characteristics (slope). Print the “Under” and “Over”  
Printer Setup Negatives on the new paper, using the  
same channel as in Step 1. Identify these prints as “Test  
Print—Normal,” “Test Print—Under,” and “Test  
Print—Over.” If the Under and Over test prints match  
the Under and Over reference prints, no further  
While pressing MODE, press SETUP. Then press NO  
until CH OVER SHIFT appears. Determine which  
channels use this paper. Do not include channel 00 in  
this correction. Place the Over negative into the  
negative mask, press D-IN, and enter the correction  
required for the Over slope. To input the sample  
correction from above for channels 10, 11, 12, 13, 14,  
and 15, enter:  
adjustment is needed. If the test prints do not match the  
reference prints, proceed to “Setting the Paper Slope.”  
Method 2:  
10-15  
-.7 M  
(O)  
Y/N  
1. When your supply of EKTACOLOR Edge 7/  
ROYAL VII Paper is about to run out, print the Printer  
Setup Negative “Normal,” “Under,” and “Over” on the  
channel most commonly used for the paper. Label the  
three prints “Old-Paper Reference Print—Normal,”  
“Old-Paper Reference Print—Under,” and “Old-Paper  
Reference Print—Over.”  
0.0 Y  
-1.5 C  
-.4 D  
(If the Over negative is not in the negative mask, an NG  
error will occur and the correction will not be made.)  
5. Press the YES key. The Channel Over Balance  
correction will be made to channels 10, 11, 12, 13, 14,  
and 15.  
2. Take densitometer readings from the Normal reference  
print; this will be your aim.  
3. Load the new paper, and make prints from the  
“Normal,” “Under,” and “Over” Printer Setup Negative.  
Be sure to use the same channel as in Step 1. Identify  
these prints as “Test Print—Normal,” “Test Print—  
Under,” and “Test Print—Over.”  
4. Read and record the test-print densities. Calculate the  
correction as follows:  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Subtract the test densities from the reference (aim)  
densities.  
by adding or subtracting from the current values and  
entering the new values. Then press ENTER.  
3. To enter the paper slope correction (over), go into the  
SETUP mode and select SLOPE ADJ. Write down the  
current values for SLOPE OVER. Make the correction  
by adding or subtracting from the current values and  
entering the new values. Then press ENTER.  
Example 1  
Densitometer Readings—Normal Reference  
and Normal Test Prints  
Cyan  
70  
Magenta  
Yellow  
70  
REFERENCE  
TEST  
70  
78  
-8  
4. Press the Shift and Centering keys and perform the Dead  
Heat procedure, using the “Normal” Printer Setup  
Negative. Then reprint both “Under” and “Over”  
negatives, and repeat Steps 1 through 3 until there is a  
difference of less than 3 densitometer points from the  
aim, with a spread between the values of less than  
5 points.  
75  
83  
Difference  
-5  
-13  
This example includes neutral density equal to the  
lowest correction figure (-5). Removing the neutral  
density results in this correction:  
5. Back up the printer data by going to the SETUP mode.  
Press MODE twice, and then press the Shift and  
Transfer keys. The display will read DATA  
TRANSFER FM_TO_. Enter “B1” in the first section,  
and then use the arrow keys to move to the second  
section and enter “B2.” Press ENTER to back up the  
new printing data.  
Cyan  
0
Magenta  
-3  
Yellow  
-8  
Density  
-5  
To change these figures from densitometer units to key  
corrections, multiply the color corrections by a factor of  
.7, and multiply the density corrections by a factor of .5.  
These are the key corrections for this example.  
Compensation Procedure for AGFA MSP  
Printers  
Cyan Magenta Yellow Density  
0
-3  
-8  
-5  
Follow this procedure to set up your printer when converting  
to KODAK EKTACOLOR Edge 8/ROYAL VIII Papers  
from KODAK EKTACOLOR Edge 7/ROYAL VII Papers  
1. Enter ITT Schwarzchild Coefficient values for KODAK  
EKTACOLOR Edge 8/EKTACOLOR ROYAL VIII  
Paper in an unused table (a total of 10 tables is  
available).  
Multiply by .7 for color  
and .5 for density  
0
-2  
-6  
-3  
5. To enter the correction, press MODE twice, and select  
COLOR BAL. Input the appropriate channel number.  
Write down the existing color balance figures as a  
reference. Add or subtract the corrections to the existing  
figures, and press ENTER. The corrections will be  
entered and the existing balance figures adjusted.  
a. Identify an available table; use DFPA (Define  
Paper). (The list of Schwarzchild tables follows this  
procedure.)  
Press the Shift and Centering keys and perform the Dead  
Heat procedure, using the “Normal” Printer Setup  
Negative. When the display reads ENTER  
RINGAROUND LEVEL#=_, press the Skip key to skip  
this part. Then return to the print mode by pressing  
MODE once.  
b. Type MOTC. The printer’s password is required.  
c. Enter a Brand/Paper Type.  
d. Enter the Schwarzchild Coefficients for  
EKTACOLOR Edge 8/ROYAL VIII Paper.  
e. Save the changes. (Enter Y when VALUES OK?  
appears.)  
Repeat Steps 3 through 5 until the test prints are within  
3 densitometer points of the aim figures, with a spread  
between the values of less than 5 points.  
2. Define the new paper.  
a. Type DFPA (Define Paper), and choose an unused  
Paper Number.  
Setting the Paper Slope  
After matching the Normal test and Normal reference prints,  
make test prints from the “Under” and “Over” Printer Setup  
Negatives. Make sure to use the same channel you used to  
make the reference prints. If the Under and Over test prints  
match the reference prints, the paper change is complete.  
If the Under and Over test prints do not match the  
reference prints, proceed as follows:  
b. Enter the Code Number from Step 1a.  
c. Identify the Paper Surface.  
d. Enter an Emulsion ID.  
e. Enter the Paper Width.  
f. Hit ESC twice.  
1. Compare the readings and work out corrections, using  
the method described in Step 4, above. (Use the aim  
figures obtained from the Normal reference print in  
Step 2, above.)  
g. Save the changes. (Enter Y when VALUES OK?  
appears.)  
3. Create a Paper Channel.  
a. Copy your current Paper Channel to an unused  
Paper Channel (use the COPC command). Enter the  
source channel and destination channel. Save the  
changes. (Enter Y when VALUES OK? appears).  
2. To enter the paper slope correction (under), go into the  
SETUP mode and select SLOPE ADJ. Write down the  
current values for SLOPE UNDER. Make the correction  
8
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
b. Type MOPC (Modify Paper Channel). Enter the  
Paper Channel that you copied to in Step 3a.  
5. Balance the paper.  
a. Load a roll of EKTACOLOR Edge 8/ROYAL VIII  
Paper into a magazine and install it in the printer.  
c. Change the Paper Type to the Paper Number of the  
new paper defined in Step 2.  
b. Load the Paper Channel from Step 2 and the Film  
Channel from Step 3, using the LOAD command.  
d. Save the changes. (Enter Y when VALUES OK?  
appears.)  
c. Expose a test print by using the ETP (Expose Test  
Print) command. Process the test print. Use the  
ACC (Automatic Channel Calibration) command  
and insert the test print when prompted. Allow the  
recommended Paper Channel changes. Make  
another test print and continue this step until no  
changes are needed.  
4. Create a Film Channel.  
a. Copy your current Film Channel to an unused Film  
Channel (use the COFC command). Enter the  
source channel and destination channel. Save the  
changes. (Enter Y when VALUES OK? appears.)  
b. Type MOFC (Modify Film Channel). Enter the  
Film Channel that you copied to in Step 4a.  
d. The balanced test print will appear cyan-green, and  
will be approximately +0.12 cyan and –0.03 green  
from neutral Status A. The Film Channel balance  
change compensates for this bias.  
c. Change the Brand/Paper Type to the code number  
of the new table created in Step 1.  
d. Adjust the balance 0.000, 0.010, -0.040 to  
compensate for the Agfa MSP densitometer.  
e. Run a reel of test negatives to confirm that the new  
paper has been correctly installed.  
e. Save the changes. (Enter Y when VALUES OK?  
appears.)  
AGFA-Recommended Schwarzchild Coefficients for KODAK EKTACOLOR Edge 8/ROYAL VIII Papers  
MSCs Without  
Loqik 4  
MSCs With  
Loqik 4  
MSP / MSC  
Blue  
Green  
0.001  
-0.002  
0.000  
0.004  
0.009  
0.016  
0.022  
0.032  
Red  
Blue  
Green  
Red  
Blue  
Green  
Red  
25ms  
0.016  
0.006  
0.000  
-0.008  
-0.013  
-0.016  
-0.016  
-0.021  
0.008  
0.002  
0.000  
0.001  
0.001  
0.002  
0.004  
0.005  
50ms  
100ms  
200ms  
400ms  
800ms  
1600ms  
3200ms  
13  
5
-9  
-6  
0
-1  
0
13  
5
-9  
-6  
0
-1  
0
0
1
3
4
0
0
0
-3  
-3  
-7  
6
1
-3  
-3  
-7  
6
13  
23  
3
13  
23  
4
Gamma 1/2/3  
1.8  
2.4  
2.7  
1.8  
2.4  
2.7  
1.8  
2.4  
2.7  
AGFA Recommendations for Printing on KODAK EKTACOLOR Edge 8/ROYAL VIII Papers  
Type Measuring Filter for  
MSP  
MSC/PSP8  
8501/147  
MSC 101  
8506/213  
7660/261  
MASK Value—MSP Only  
(Command MOTC)  
Blue  
0.901  
1.322  
1.778  
2.623  
Green  
0.720  
1.060  
1.435  
2.201  
Red  
Mask  
Under  
Normal  
Over  
0.340  
0.718  
1.128  
1.913  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
c. Enter the Schwarzchild Coefficients for EDGE 8/  
ROYAL VIII Paper into an unused TFS (Total Film  
Scanning) location (21, 22, or 23).  
Compensation Procedure for AGFA MSC  
Printers  
Follow this procedure to set up your printer when converting  
to KODAK EKTACOLOR Edge 8/ROYAL VIII Papers  
from KODAK EKTACOLOR Edge 7/ROYAL VII Papers.  
1. Confirm your setup for EKTACOLOR Edge 7/  
ROYAL VII Paper.  
d. Set the configuration channel to use the paper and  
film channels selected in Step 1.  
e. Change the paper channel to use the TFS with the  
Schwarzchild Coefficients for Edge 8/  
ROYAL VIII Paper.  
a. Perform “Auto Calibration” of MBL (Master  
Balance) with EKTACOLOR Edge 7/ROYAL VII  
Paper.  
3. Balance the channel for EKTACOLOR Edge 8/  
ROYAL VIII Paper.  
b. Perform “Auto Calibration” of Edge 7/ROYAL  
VII Paper PBL (Paper Balance).  
a. Select the configuration channel for Edge 8/  
ROYAL VIII Paper.  
c. Print the “Normal” Printer Setup Negative.  
Compare the print to the aim. If necessary, adjust  
FBL (Film Balance) to match the aim. Keep the  
final print as a reference for setting up the film  
channel for EKTACOLOR Edge 8/ROYAL VIII  
Paper.  
b. Load a paper magazine with the new paper and  
perform “Auto Calibration” of PBL.  
Note: You will need to set the paper magazine pins to  
the paper channel selected.  
c. Print the setup negative.  
2. Set up a configuration channel.  
d. Adjust the FBL to make this setup print match the  
setup aim from Edge 7/ROYAL VII Paper.  
a. Select an unused configuration, paper, and film  
channel for use with Edge 8/ROYAL VIII Paper.  
Note: The final setup print will appear cyan; this is  
correct for Edge 8/ROYAL VIII Paper.  
b. Copy the current Edge 7/ROYAL VII Paper  
configuration channel into the configuration  
channel you have selected for Edge 8/ROYAL VIII  
Paper.  
10  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To track other paper widths with the 4-inch reference  
paper:  
Select the paper channel to be adjusted (SET/PRINTER/  
PAPER/DIRECT), scroll down to “same brand as reference  
paper,” and enter YES.  
Compensation Procedure for GRETAG  
Masterlab  
Follow this procedure to set up your printer when converting  
to KODAK EKTACOLOR Edge 8 or ROYAL VIII Paper  
from KODAK EKTACOLOR Edge 7 or ROYAL VII Paper.  
If you are not converting all paper widths to  
Before Converting to the New Paper  
Make reference prints from the last roll of EKTACOLOR  
Edge 7/ROYAL VII Paper.  
EKTACOLOR Edge 8/ROYAL VIII Paper at one time:  
1. Select the paper channel that will continue to use  
Edge 7/ROYAL VII Paper.  
2. To turn off “same brand as reference paper,” press SET/  
PRINTER/PAPER/DIRECT, scroll down to screen 11,  
and enter NO.  
To confirm that the current setup is correct:  
1. Check the daily setup: CHECK/PRINTER/EXPOSE.  
Repeat the test until it passes.  
3. Set the paper balance to zero for all colors: SET/  
PRINTER/PAPER/DIRECT, screen 3. Enter YES to  
save the data.  
2. Check the 4-inch paper slope: CHECK/PAPER/  
EXPOSE. Repeat the test until it passes.  
To make reference prints on 4-inch  
EKTACOLOR Edge 7/ROYAL VII Paper  
1. Print a test negative strip on Edge 7/ROYAL VII Paper.  
4. Set the format balance to zero for all colors: SET/  
PRINTER/FORMAT/DIRECT, screen 2. Enter YES to  
save the data.  
Do not read the prints with the densitometer. Use them  
as a visual reference only.  
5. Run a paper balance test: CHECK/PAPER/EXPOSE.  
Repeat the test until it passes.  
2. Save all your current data to a memory card for security:  
COMM/SYSTEM/SAVE/START.  
Note: These test patches will be appear pink, not  
neutral. This is correct.  
3. If you have customized your production, note the deltas  
for all negatives, unders, and overs, in case you need to  
use the same customization again: SET/PRINTER/  
MASTER/DELTAS.  
Enter the manual correction values below: SET/  
PRINTER/MASTER/DELTAS.  
Y
M
0
C
D
-0.5  
+1.8  
-2.0  
Converting to the New Paper  
To make new reference prints:  
1. Load 4-inch Edge 8/ROYAL VIII Paper.  
Make test prints from customer negatives. If you need to  
customize production, start by entering the delta values you  
noted previously for Edge 7/ROYAL VII Paper production.  
Then adjust these values (SET/PRINTER/MASTER/  
SETMAN) based on visual assessment.  
2. Change the aim: SET/MENU/PRINTER/MASTER/  
DIRECT. In the second screen, change the aim values to  
these new values:  
Y
M
C
Compensation Procedure for GRETAG  
Masterflex  
0.80  
0.80  
0.70  
Follow this procedure to set up your printer when converting  
to KODAK EKTACOLOR Edge 8 or ROYAL VIII Paper  
from KODAK EKTACOLOR Edge 7 or ROYAL VII Paper.  
Press ENTER.  
3. Print the test negative strip on the new paper: SET/  
PRINTER/MASTER/TEST. Line up negative No. 3,  
and press START.  
Before Converting to the New Paper  
Make reference prints from the last roll of EKTACOLOR  
Edge 7/ROYAL VII Paper.  
4. Read all the prints, pressing the down arrow ()  
between readings.  
Note: Read the small grey patch, second from the right,  
not the large central patch. Press SET/PRINTER/  
MASTER/SETDEN. For “new ref film,” enter YES.  
For “save data,” enter YES.  
To confirm that the current setup is correct:  
Check the daily setup: TEST/PRINTER/EXPOSE.  
MEASUREÐ, UPDATE/Ð. Repeat the test until it passes.  
Note: In subsequent printing of the test negative strip,  
when “new ref film” appears, press NO.  
To make reference prints on 4-inch EKTACOLOR  
Edge 7/ROYAL VII Paper:  
5. Set all deltas to zero: SET/PRINTER/MASTER/  
DELTAS.  
1. Print a few customer prints on Edge 7/ROYAL VII  
Paper. Use these prints as a visual reference only.  
Make some test prints from customer negatives. If you  
need to customize production, start by entering the delta  
values you noted previously for Edge 7/ROYAL VII Paper  
production. Then adjust those values (SET/PRINTER/  
MASTER/SETMAN) based on visual assessment.  
2. Save all your current data to a memory card for security:  
OPERATE/ WRITE BACKUP TO CARD/Ð.  
3. If you have customized your production, note the deltas  
for all negatives, unders, and overs, in case you need to  
use the same customization again: SETUP/PRINTER/  
MASTER/EDIT; scroll down to the third screen.  
Printer Conversion to KODAK EKTACOLOR Edge 8 and EKTACOLOR ROYAL VIII Papers CIS-201  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printer Conversion to KODAK EKTACOLOR Edge 8 and  
EKTACOLOR ROYAL VIII Papers  
Converting to the New Paper  
To make new reference prints:  
1. Load 4-inch Edge 8/ROYAL VIII Paper.  
3. Enter the manual delta correction values below: SETUP/  
PRINTER/PAPER/EDIT. Highlight the paper size to be  
edited.  
2. Change the aim: SETUP/PRINTER/MASTER/EDIT.  
In the second screen, change the aim values to these new  
values:  
Y
M
C
-0.02  
-0.06  
+0.02  
Y
M
C
Note: When entering deltas, note that 1.0 is equivalent to  
10 color buttons, i.e., 0.1 = 1 color button.  
1.0  
1.0  
0.9  
Make test prints from customer negatives. If you need to  
customize production, adjust the delta values (SETUP/  
PRINTER/PAPER/EDIT) based on visual assessment.  
3. Change deltas to zero, as above: SETUP/PRINTER/  
MASTER/EDIT. In the third screen, change all delta  
values to zero.  
4. Press TEST/PRINTER/EXPOSE. MEASURE/Ð,  
UPDATE/Ð. Repeat the test until it passes.  
MORE INFORMATION  
Kodak has many publications to assist you with information  
on Kodak products, equipment, and materials.  
Additional information is available on the Kodak website  
and through the U.S.A./Canada faxback system.  
The following publications are available from dealers who  
sell Kodak products, or you can contact Kodak in your country  
for more information.  
5. Print the full “test film set” of negatives on the new  
paper: SETUP/PRINTER/PAPER/FULL PAPER  
TEST/EXPOSE. Make sure the paper channel with “**”  
is highlighted; this designates the master channel.  
6. Read all the prints in the same order in which they were  
exposed: MEASURE.  
7. If the test is “Not OK,” repeat Steps 5 and 6.  
Make some test prints from customer negatives. If you  
need to customize production, start by entering the delta  
values you noted previously for Edge 7/ROYAL VII Paper  
production. Then adjust those values (SETUP/PRINTER/  
MASTER/EDIT, screen 3) based on visual assessment.  
For the latest version of technical support publications for  
KODAK Products, visit Kodak on-line at:  
Many technical support publications for KODAK  
Products can be sent to your fax machine  
To track other paper widths with the 4-inch reference  
paper:  
1. Select the paper channel that will convert to Edge 8/  
from the Kodak Information Center. Call:  
U.S. 1-800-242-2424, Ext. 33 / Canada 1-800-295-5531  
—Available 24 hours a day, 7 days a week—  
ROYAL VIII Paper.  
If you have questions about KODAK Products, call Kodak.  
In the U.S.A.:  
2. To track with the “reference paper,” press SETUP/  
PRINTER/PAPER/EDIT; scroll down to screen 2.  
“Reference Paper” should show “4" Gloss.” If it does  
not, press the “Reference Paper” button and select  
“4" paper.” Confirm with Ð.  
1-800-242-2424, Monday–Friday  
9 a.m.–7 p.m. (Eastern time)  
In Canada:  
1-800-465-6325, Monday–Friday  
8 a.m.–5 p.m. (Eastern time)  
If you are not converting all paper widths to  
EKTACOLOR Edge 8/ROYAL VIII Paper at one time:  
1. Load the paper size that will continue to use Edge 7/  
ROYAL VII Paper.  
2. Run a paper balance test: TEST/ PAPER/ EMULSION/  
EXPOSE. Repeat this test until it passes.  
Note: These test patches will appear pink, not neutral.  
This is correct.  
Consumer Imaging  
EASTMAN KODAK COMPANY ROCHESTER, NY 14650  
Printer Conversion to KODAK  
EKTACOLOR Edge 8 and  
Kodak, Ektacolor, and Royal  
Minor Revision 3-00  
Printed in U.S.A.  
are trademarks.  
EKTACOLOR ROYAL VIII Papers  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Cooktop K1G21 R User Manual
International Home Products Flooring Floors User Manual
John Deere Tiller RT 1173 User Manual
John Lewis Clothes Dryer JLTDC10 User Manual
JVC Battery Charger AA V80EG User Manual
JVC CD Player KD G110 User Manual
Kenmore Dishwasher 5871521 User Manual
Kicker Speaker ZK500 User Manual
Kodak Printer ESP 7200 User Manual
Kramer Electronics Stereo System WP 500 User Manual