KitchenAid Ventilation Hood 423 User Manual

®
36" and 48" Island Canopy Range Hood  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
CABINET OPENING DIMENSIONS  
KICU265H  
KICU285H  
10 7/8"  
(27.6 cm)  
support  
structure  
7 1/16"  
(17.9 cm)  
upper  
chimney  
1" (2.5 cm) min. -  
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.  
electrical supply. Use copper wire only. A time-  
delay fuse or circuit breaker and separate circuit is  
recommended.  
11-1/8" (23.8 cm) max.  
upper chimney height  
lower  
chimney  
24-5/8" (62.5 cm) min. -  
canopy  
23-5/8"  
(60 cm)  
lower  
34-3/4" (88.3 cm) max.  
overall chimney height  
chimney  
height  
24" (61 cm) min.  
bottom of canopy to  
cooking surface  
8’ (2.4 m) min. -  
9’ (2.7 m) max.  
ceiling to floor  
10-1/4" (26 cm)  
canopy height  
23-5/8" (60 cm)  
overall depth  
36" hood 35-3/8" (89.9 cm) or  
48" hood 47-1/4" (120 cm)  
overall width  
36" (91.4 cm)  
base cabinet  
height  
VENTING REQUIREMENTS  
Vertical roof venting  
The vent system length should not  
exceed the lengths shown in the  
chart below.  
3-1/4" x 10" (8.3 cm x 25 cm)  
v
ent system  
roof cap  
3-1/4" x 10"  
3-1/4" x 10”  
(8.3 cm x 25 cm)  
elbow  
wall  
cap  
(8.3 cm x 25 cm)  
through  
the roof  
Vent size  
3-1/4" x 10"  
Maximum length  
6 ft. (1.8 m)  
35 ft. (10.7 m)  
(8.3 cm x 25 cm)  
7" (17.8 cm) round  
40 ft. (12.2 m)  
50 ft. (15.2 m)  
60 ft. (18.3 m)  
8" (20.3 cm) round  
9" (22.9 cm) round  
Note: 3-1/4" x 10"  
(8.3 cm x 25 cm)  
rectangular vent must  
be used inside chimney  
cover. Round vent will  
not fit inside chimney  
cover.  
2 ft.  
(0.6 m)  
To calculate the length of the system you need, add the  
equivalent feet for each vent piece used in the system.  
Maximum length  
= 35 ft. (10.7 m)  
1 — 90° elbow  
8 ft. (2.4 m) straight  
1 — wall cap  
=
=
=
5 ft. (1.5 m)  
8 ft. (2.4 m)  
0 ft. (0 m)  
Vent Piece  
3-1/4" x 10" (8.3 cm x 25 cm) 7" (17.8 cm), 8" (20.3 cm)  
Rectangular  
or 9" (22.9 cm) Round  
Horizontal wall venting  
45° elbow  
7.0 feet  
2.5 feet  
(0.8 cm)  
Length of 3-1/4" x 10"  
(8.3 cm x 25 cm)  
system  
3-1/4" x 10"  
(2.1 m)  
(8.3 cm x 25 cm)  
through the wall  
wall cap  
= 13 ft. (4 m)  
90° elbow  
5.0 feet  
(1.5 m)  
5.0 feet  
(1.5 m)  
Note: Flexible vent is Not  
recommended.  
If it is used, each foot of flexible vent  
used is equivalent to two feet (61 cm)  
of straight metal vent when  
calculating the vent system length.  
(Example: A flexible elbow equals two  
standard elbows.)  
90° flat elbow  
12.0 feet  
(3.7 m)  
Note: 3-1/4" x 10"  
(8.3 cm x 25 cm)  
rectangular vent must  
be used inside chimney  
cover. Round vent will  
not fit inside chimney  
cover.  
transition to round  
5.0 feet  
(1.5 m)  
wall cap  
0.0 feet  
(0.0 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 4360369 Rev. C  
10-15-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer WI 101 User Manual
John Lewis Oven JLBIDO911 User Manual
Johnson Controls Air Conditioner ACPU024 THRU 060 User Manual
JVC Car Stereo System LVT1055 001A User Manual
JVC DVD Player XV 511BK User Manual
Kalorik Coffeemaker USK CM 4 User Manual
Kenmore Range 3626278 User Manual
Kirkland Signature Clothes Dryer 3406079 User Manual
KitchenAid Double Oven KEBK101S User Manual
Kodak Digital Photo Frame P750 User Manual