KitchenAid Saw KSDG950E User Manual

30" (76.2 cm) Double Oven Dual Fuel Range  
PRODUCT MODEL NUMBERS  
KSDG950E KSEG950E  
PRODUCT DIMENSIONS  
This manual covers several models. Your model may appear  
different from the models depicted. Dimensions given are  
maximum dimensions across all models.  
GAS SUPPLY REQUIREMENTS  
Observe all governing codes and ordinances.  
IMPORTANT: This installation must conform with all local codes and  
ordinances. In the absence of local codes, installation must conform  
with American National Standard, National Fuel Gas Code ANSI Z223.1  
– latest edition or CAN/CGA B149 – latest edition.  
B
C
A
IMPORTANT: Leak testing of the range must be conducted according  
to the manufacturer’s instructions.  
Type of Gas:  
Natural Gas:  
This range is design-certified by CSA International for use with Natural  
gas or, after proper conversion, for use with LP gas.  
D
• This range is factory-set for use with Natural gas. See “Gas  
Conversions” section. The model/serial/rating plate located on the  
oven frame behind the top right-hand side of the oven door has  
information on the types of gas that can be used. If the types of gas  
listed do not include the type of gas available, check with the local  
gas supplier.  
E
LP Gas Conversion:  
Conversion must be done by a qualified service technician. No attempt  
shall be made to convert the appliance from the gas specified on the  
model/serial/rating plate for use with a different gas without consulting  
the serving gas supplier. See “Gas Conversions” section.  
F
A. 1³⁄16" (3.0 cm) height from cooktop to top of vent  
B. 2978" (75.9 cm)  
C. Model/serial/rating plate (located behind the oven door on the top  
right-hand side of the oven frame)  
D. 36" (91.4 cm) height to top of cooktop edge with leveling legs  
screwed in all the way*  
E. 28516" (71.9 cm) max. depth from front of console to back of range  
F. 2878" (73.3 cm) max. depth from handle to back of range  
Gas Supply Line  
• Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range  
location. A smaller size pipe on longer runs may result in insufficient  
gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm)  
minimum. Usually, LP gas suppliers determine the size and materials  
used in the system. NOTE: Pipe-joint compounds that resist the  
action of LP gas must be used. Do not use TEFLON®† tape.  
Flexible metal appliance connector:  
IMPORTANT: Range must be level after installation. Follow the  
instructions in the “Level Range” section. Using the cooktop as a  
reference for leveling the range is not recommended.  
• If local codes permit, a new CSA design-certified, 4 to 5 ft  
(122 to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9 cm) I.D.  
(inside diameter), flexible metal appliance connector  
may be used for connecting range to the gas supply line.  
* Range can be raised approximately 1" (2.5 cm) by adjusting the  
leveling legs.  
ELECTRICAL REQUIREMENTS  
• A 1/2" (1.3 cm) male pipe thread is needed for connection  
to the female pipe threads of the inlet to the appliance  
pressure regulator.  
It is recommended that all electrical connections be made by a  
licensed, qualified electrical installer.  
• Range must be connected to the proper electrical voltage and  
frequency as specified on the model/serial/rating plate. The model/  
serial/rating plate is located on the right vertical surface of the oven  
door frame. Refer to the illustrations in the “Product Dimensions”  
section of the “Location Requirements” section.  
• Do not kink or damage the flexible metal tubing when moving  
the range.  
• Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve.  
This valve should be located in the same room but external  
to the range opening, such as an adjacent cabinet. It should  
be in a location that allows ease of opening and closing. Do  
not block access to shutoff valve. The valve is for turning on  
or shutting off gas to the range.  
• This range is manufactured with a 4-wire power supply cord rated at  
240 volts, 40 amps, rated at 194°F (90°C) and investigated for use  
with this range.  
Specified Rating of Power  
Supply Cord Kit and Curcuit  
B
Range Rating*  
Protection  
120/240 Volts  
120/208 Volts  
Amps  
Temp Rating  
194°F (90°C)  
194°F (90°C)  
A
8.8 – 16.5 KW  
7.8 – 12.5 KW  
40 or 50  
16.6 – 22.5 KW 12.6 – 18.5 KW 50  
C
* The NEC calculated load is less than the total connected load listed  
on the model/serial/rating plate.  
A. Gas supply line  
B. Shutoff valve “open” position  
C. To range  
Page 1 of 2  
†®TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.  
Ref. W10787365A  
05/15  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Jensen Handheld TV JDTV 750 User Manual
JL Audio Car Speaker SB D MGACAB 10W6v2 User Manual
JVC DVD Player XV M50BK User Manual
Kawai Electronic Keyboard CP177 User Manual
Kenmore Water System 6253847 User Manual
Kenwood Car Stereo System KDC 3020R User Manual
KitchenAid Oven KCO1005 User Manual
Kodak Camcorder ZM2 User Manual
Kolcraft Stroller S47J R7 User Manual
Kramer Electronics Marine Radio VM 4HD User Manual