KitchenAid Double Oven KEBU107S User Manual

®
30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN  
PRODUCT MODEL SERIES  
KEBU107S KEBU208S  
OVERALL DIMENSIONS  
A
Electrical: Oven must be connected to the  
proper electrical voltage and frequency as  
specified on the model/serial number rating  
plate. (The model/serial number rating plate  
is located at the bottom of the right-hand  
mounting rail.) Models rated from 7.3 to 9.6  
kW at 240 volts (5.5 to 7.2 kW at 208 volts)  
require a separate 50-amp circuit. Models  
rated at 7.2 kW and below at 240 volts  
(5.4 kW and below at 208 volts) require a  
separate 30-amp circuit.  
A circuit breaker is recommended. Connect  
directly to the fused disconnect (or circuit  
breaker box) through flexible, armored or  
nonmetallic sheathed, copper cable (with  
grounding wire).  
A
B
E
B
E
A cold water supply with water pressure  
between 30 and 120 psi (207 and 827 kPa)  
is required to operate the steam feature. In  
Massachusetts, plumbing code 248 CMR  
3.00 and 10.00 must be followed. If you  
have questions about your water pressure  
call a licensed, qualified plumber.  
C
D
C
D
A. 28⁵⁄₁₆" (71.9 cm) max. recessed width  
B. 28¾" (73.0 cm) max. overall height  
C. 29³⁄₄" (75.6 cm) overall width  
A. 28⁵⁄₁₆" (71.9 cm) max. recessed width  
B. 50³⁄₄" (128.9 cm) max. overall height  
C. 29³⁄₄" (75.6 cm) overall width  
D. 23" (58.4 cm) max. recessed depth  
E. 27¹⁄₂" (69.9 cm) recessed height  
D. 23" (58.4 cm) max. recessed depth  
E. 49⁹⁄₁₆" (125.9 cm) recessed height  
CABINET OPENING DIMENSIONS  
Single Oven Installed in Cabinet  
Double Oven Installed in Cabinet  
A
A
Single Oven Undercounter  
(without cooktop installed above)  
B
A
B
B
A. 30" (76.2 cm) min. cabinet width  
B. 1¹⁄₂" (3.8 cm) min. top of cutout to  
underside of countertop  
C. 5¹⁄₄" (13.3 cm) bottom of cutout to floor  
D. 28¹⁄₂" (72.4 cm) cutout width  
F
E
F
D
D
E. 27³⁄₄" (70.5 cm) min. cutout height  
E
E
D
C
C
C
Cabinet Side View -  
Double or Single Oven  
A. 30" (76.2 cm) min. cabinet width  
B. 1" (2.5 cm) top of cutout to bottom of upper  
cabinet door  
C. 14³⁄₄" (37.5 cm) bottom of cutout to floor  
D. 28¹⁄₂" (72.4 cm) cutout width  
E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of  
cabinet door  
F. 49³⁄₄" (126.4 cm) min. cutout height  
A. 30" (76.2 cm) min. cabinet width  
B. 1" (2.5 cm) top of cutout to bottom of upper  
cabinet door  
C. 32" (81.3 cm) bottom of cutout to floor  
D. 28¹⁄₂" (72.4 cm) cutout width  
E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of  
cabinet door  
F. 27³⁄₄" (70.5 cm) cutout height  
A
B
A. 24" (61.0 cm) min. cutout depth  
B. 23" (58.4 cm) recessed oven depth  
C. Oven front  
D. Recessed oven  
E. Cabinet  
E
C
Typical Water Filtration System Installation Configuration  
NOTE: For unique installations contact a licensed plumber.  
D
A. 2  
B. 2  
C. O  
D. R  
E. C  
Cold water  
supply  
Hot  
Cold  
Filter  
assembly  
location  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8304535A  
06-18-07  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Intel Computer Hardware XP M5S661GX User Manual
Invacare Indoor Furnishings 9610 1 User Manual
Invacare Mobility Aid 3002801 User Manual
Jackson Dishwasher Tempstar GP User Manual
John Deere Drill AT 3502 J User Manual
JVC DVD Player 0105MOC MW SC User Manual
JVC Home Theater System GR D360 User Manual
Kambrook Blender KBL70 User Manual
KitchenAid Oven KEBS177SSS03 User Manual
Kolcraft Stroller S45J R7 User Manual