30" (76.2 CM) GAS DOWNDRAFT COOKTOP
PRODUCT MODEL NUMBERS
CUTOUT DIMENSIONS
KGCD807X
B
A
C
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural Gas:
D
This cooktop is design-certified by CSA International for use with Natural gas or,
after proper conversion, for use with LP gas.
E
F
ꢀ
This cooktop is factory set for use with Natural gas. If converting to LP gas, see
H
the “LP Gas Conversion” instructions provided in the package containing
literature. The model/serial rating plate located on the underside of the cooktop
base has information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local gas supplier.
I
LP Gas Conversion:
Conversion must be done by a qualified service technician.
J
G
No attempt shall be made to convert the cooktop from the gas specified on the
model/serial rating plate for use with a different gas without consulting the
serving gas supplier. See the Gas Conversion instructions provided in the
package containing literature.
Gas Supply Line
A. 28⁵⁄₈" (72.7 cm) maximum
B. 19¹⁵⁄₁₆" (50.6 cm) maximum
C. 9⁵⁄₁₆" (21.6 cm)
D. 6⁴⁹⁄₆₄" (17.2 cm)
E. 2¹⁄₈" (5.4 cm) minimum space to front edge of cooktop
ꢀ
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the cooktop location. A
smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint
compounds that resist the action of LP gas must be used. Do not use TEFLON®†
tape. With LP gas, piping or tubing size should be ¹⁄₂" minimum. Usually, LP
gas suppliers determine the size and materials used in the system.
F. Floor exhaust option
G. 6¹⁄₈" (15.6 cm) for 6" (15.2 cm) vent system and 5¹⁄₈" (13.1 cm) for
Flexible metal appliance connector:
5" (12.7 cm) vent system
ꢀ
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing gas
H. 9⁵⁄₁₆" (21.6 cm)
I. 13³⁄₈" (33.9 cm) from the top of the countertop surface
J. Wall exhaust option
connector, designed by CSA to connect the cooktop to the rigid gas supply
line.
PRODUCT DIMENSIONS
Rigid pipe connection:
30" (76.2 cm) Cooktop
The rigid pipe connection requires a combination of pipe fittings to obtain an in-
line connection to the cooktop. The rigid pipe must be level with the cooktop
connection. All strains must be removed from the supply and fuel lines so
cooktop will be level and in line.
A
B
ꢀ
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve
should be located in the same room but external to the cooktop opening, such
as an adjacent cabinet. It must be accessible without removing the cooktop,
and it should be in a location that allows ease of opening and closing. Do not
block access to shutoff valve. The valve is for turning on or shutting off gas to
the cooktop.
C
A. 21³⁷⁄₆₄" (54.8 cm) with stainless steel trim or
21½" (54.6 cm) without stainless steel trim
B. 19⁴⁷⁄₆₄" (50.1 cm) screw head to screw head
C. Model/serial rating/clearance plate location
B
A
C
A. Gas supply line
B. Shutoff valve “open” position
C. To cooktop
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Page 1 of 2
Ref. W10526087A
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
5/6/13
Download from Www.Somanuals.com. All Manuals Search And Download.
|