Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KEYS700J
KEYS700L
KEYS710L
KEYS750J
KEYS750L
KEYS850J
KEYS850L
KEYS855J
Electrical: A four-wire or three-wire, single
phase, 120/240-volt, 60-Hz, AC-only, electrical
supply (or 120/208-volt electrical supply, if
specified on the serial/rating plate) is required on a
separate 30-ampere circuit, fused on both sides of
the line. Use 10 gauge solid copper wire. A time-
delay fuse or circuit breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
Not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.
RECESSED AREA AND CLOSET INSTALLATION
"
"
"
1. Small Opening Side-Swing Door
2. Large Opening Side-Swing Door
3. Wide Opening Side-Swing Door
4. Wide Opening Hamper Door
"
"
"
51
"
2
29"
(73.66 cm)
"
27
"
"
4
"
(70.5 cm) (14 cm)
1
3
2
For closet installation with a door, minimum
ventilation openings in the top and bottom of
the door are required. Louvered doors with
equivalent air openings are acceptable.
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents
EXHAUST VENTING
1. Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns. When using
elbows or making turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90° turns.
4"
(10.2 cm)
Box hood style
4"
(10.2 cm)
2.5"
(6.4 cm)
2. Determine vent length.
4"
(10.2 cm)
Angled style
The maximum length of the exhaust system depends upon:
Louvered style
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum
vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
Vent Length Chart
Number of
90° turns
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0
1
2
3
4
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
28 ft (8.5 m)
Flexible metal 36 ft (11 m)
Rigid metal
Flexible metal
54 ft (16.5 m)
31 ft (9.4 m)
48 ft (14.6 m)
23 ft (7 m)
In the column listing the type of metal vent you are using (rigid metal or flexible
metal), find the maximum length of metal vent on the same line as the number of
elbows.
Rigid metal
Flexible metal 27 ft (8.2 m)
44 ft (13.4 m) 38 ft (11.6 m)
19 ft (5.8 m)
Rigid metal
Flexible metal 25 ft (7.6 m)
35 ft (10.7 m) 29 ft (8.8 m)
17 ft (5.2 m)
Rigid metal
Flexible metal 23 ft (7 m)
27 ft (8.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8535888
09-17-02