Battery Powered
Carbon Monoxide
Alarm
User’s Guide
Model KN-COB-B
P/N: 9CO5
Carbon Monoxide Alarm
MOVE TO
FRESH AIR
TEST/
RESET
OPERATE
ALARM
ATTENTION: Please take a few minutes to thoroughly
read this manual, which should be saved for future
reference and passed on to any subsequent owner. If
you have any questions about the operation or
installation of your alarm, please call our toll free
Consumer Hotline at 1-800-880-6788.
810-1362 REV. B
Download from Www.Somanuals.com. All Manuals Search And Download
Table of Contents
Carbon Monoxide Overview
Carbon Monoxide Overview . . . . . .Page 2
Quick Set Up . . . . . . . . . . . . . . . . . . .Page 3
Your new Kidde carbon monoxide (CO) alarm is a sophisticated
instrument that has been carefully designed and tested to assure
accurate detection of CO build up in a residential environment.
Your Kidde is for use specifically in the home.
Carbon monoxide cannot be seen, smelled or tasted and can be
fatal. The build up of CO in the blood is called the carboxyhemo-
globin level and interferes with the body’s ability to supply itself with
oxygen. Depending on the concentration, carbon monoxide can kill
in minutes.
The most common sources of carbon monoxide are malfunction-
ing gas appliances used for heating and cooking, vehicles running in
an attached garage, blocked chimneys or flues, portable fuel burning
heaters, fireplaces, fuel powered tools and operating a grill in an
enclosed space.
Installation Instructions . . . . . . . . . .Pages 4-5
Installation Location
Mounting
Where to Install
Where NOT to Install
Features and Operations . . . . . . . . .Pages 6-7
Red Alarm Indicator
Green Operating Indicator
Test/Reset Button
Battery Installation/Replacement . .Pages 8-9
Indications of carbon monoxide poisoning include symptoms sim-
ilar to the flu, but with no fever. Other symptoms include dizziness,
fatigue, weakness, headache, nausea, vomiting, sleepiness and confu-
sion. Everyone is susceptible to the danger of CO, but experts agree
that unborn babies, small children, pregnant women, senior citizens
and people with heart or respiratory problems are at the highest risk
for serious injury or death. Each year a qualified technician should
inspect and clean your heating system, vents, chimney, and flues.
Your new Kidde CO alarm has a five year limited warranty.
Please take a few minutes to thoroughly read the user’s guide and
familiarize yourself and your family with its operation. Your Kidde
CO alarm was designed to detect carbon monoxide gas from ANY
source of combustion. IT IS NOT DESIGNED TO DETECT SMOKE,
FIRE OR ANY OTHER GASES. If you have any questions please
call our Consumer Hotline at 1-800-880-6788.
What To Do If The Alarm Sounds . .Page 10
Alarm Instructions/Emergency Response
Alarm/Danger Levels . . . . . . . . . . . .Pages 11-12
Caring For Your Kidde Battery
Powered CO Alarm . . . . . . . . . . . . . .Page 13
Frequently Asked Questions . . . . . . .Page 14
Wall Mounting Template . . . . . . . . . .Page 14
Product Specifications . . . . . . . . . . .Page 15
Limited Warranty . . . . . . . . . . . . . . .Page 16
This manual and the products described are copyrighted, with all
rights reserved. Under these copyright laws, no part of this manual
may be copied for use without the written consent of KIDDE Safety.
If you require further information, contact our Consumer Hotline, or
write to us at:
Thank you for the purchase of your new Kidde carbon
monoxide alarm. If you have any questions about the
operation or setup of your CO alarm, feel free to call
our Consumer Hotline at 1-800-880-6788.
Kidde / Pyrene Corp.
13o Esna Park Drive, Markham, ON, Canada L3R 1E3
Consumer Hotline: 1-800-880-6788
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
Installation Instructions
Quick Set Up
Mounting
Remove the three enclosed AA
batteries and install them into the
battery well. Carefully place the
red battery warning flags into the
battery well. Observe the battery
polarity markings at the bottom of
the battery well.
1. Using the template provided (see
page 18). Mark the location on wall.
2. Insert the two screws provided until
the screw heads are approximately
1/8” from wall. (If mounting in
plaster board or drywall, drill 3/16”
hole and use the plastic anchors
provided.)
When the batteries are first
Figure 1
installed, the unit will beep once and the red alarm light will
flash. After approximately 20-30 seconds the green light will
flash indicating that the unit is operational. Replace battery
cover. Your Kidde CO alarm is now operational.
3. Hook the Kidde CO Alarm unit over the screws onto
keyholes in back of unit.
Seven (7) years after initial power up, this unit will "chirp"
every 30 seconds to indicate that it is time to replace the
alarm. After seven years the device may no longer detect car-
bon monoxide accurately and should be replaced immediately.
To help identify the date to replace the unit, a label has been
affixed to the side of the alarm. Write the "Replace by" date (7
years from power up) in permanent marker on the label.
Installation Location
When choosing your installation locations, make sure you can
hear the alarm from all sleeping areas. If you install only one
carbon monoxide alarm in your home, install the alarm near
bedrooms, not in the basement or furnace room.
Recommended Locations - Upper Levels of Home
• If you have only
Where To Install Your Kidde CO Alarm
one alarm, place it
The following suggestions are intended to help you with
the placement and installation of your Kidde CO alarm.
DINING
KITCHEN BEDROOM BEDROOM
near sleeping
areas, not near fuel
burning appli-
ances, such as fire-
places, furnaces or
hot water heaters.
• Place out of the reach of children. Under no circumstance
should children be allowed to handle the CO alarm.
LIVING ROOM
BEDROOM
• Install in a bedroom or hallway located close to the
sleeping area. Take special care to verify the alarm can
be heard in sleeping areas.
- Basement Levels of Home
• It is recommended that a CO alarm be installed on each
level of a multilevel home.
FURNACE
ROOM
• Locate at least 5 feet away from all fuel burning appliances.
• Placing at eye level allows for optimum monitoring of
the red and green indicator lights.
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions (cont.)
Features and Operation
• Insure that all vents of the unit are unobstructed.
Your new Kidde battery powered CO alarm utilizes
sophisticated electronic components to protect you and your
family from the dangers of CO. Unique features include red
and green diagnostic lights, battery status, and sensor health.
Familiarize yourself with these features:
• Do not install in dead air spaces such as peaks of
vaulted ceilings, or gabled roofs.
• Do not install in turbulent air from ceiling fans.
Do not place near fresh air vents or close to doors
and windows that open to the outside.
Red Alarm Indicator Light
If a dangerous level of carbon monoxide is detected the
red alarm LED will pulse and a loud (85 decibel) alarm pat-
tern will sound. When the device detects Carbon Monoxide,
the alarm pattern will be 4 short beeps – followed by 5
seconds of silence – followed by 4 short beeps with a
corresponding red LED flash. This cycle will continue for 4
minutes and then change to 1 cycle every 1 minute until the
device is reset or the CO is
• Keep the CO alarm away from excessively dusty, dirty,
or greasy areas such as kitchens, garages and furnace
rooms. Dust, grease and household chemicals can
affect the sensor.
• Keep out of damp and humid areas such as the
bathroom. Avoid spraying aerosols near the CO alarm.
• Do not install in areas where the temperature is below
40˚ Fahrenheit (4.4˚ Celsius) or hotter than 100˚
Fahrenheit (37.8˚ Celsius).
eliminated. See figure 2.
See page 11-12 for an
understanding of which CO
• Do not place behind curtains or furniture. CO must
be able to reach the sensor for the unit to accurately
detect carbon monoxide.
levels are dangerous.
Alarm
Figure 2
Green Operate Indicator
Light
The green light flashing every 30 seconds indicates the
unit is functioning properly (see figure 3).
The green light will flash before a CO reading is taken and
when any button is pressed.
The following conditions can result in transient CO situations:
Excessive spillage or reverse venting of fuel-burning appliances caused
by:
•
outdoor ambient conditions, such as wind direction and/or velocity,
including high gusts of wind, and insufficient draft in the vent pipes;
•
•
negative pressure differential resulting from the use of exhaust fans;
simultaneous operation of several fuel-burning appliances competing
for limited internal air;
If the unit chirps once every 30 seconds, observe the unit for
the following:
•
•
loose vent pipe connections from fuel-fired appliances;
A chirp every 30 seconds, with a green LED flash followed
by a red LED flash, indicates the batteries are low. Follow
the battery installation/replacement instructions on page 9
and 10.
obstructions, or unconventional vent pipe designs that can amplify
the above situations;
•
poorly designed or maintained chimneys and/or vents;
Extended operation of unvented fuel-burning devices (range, oven,
fireplace, etc.);
A chirp every 30 seconds, with a red flash and no green LED
flash indicates a unit error. If the unit does not respond,
call the Kidde consumer hotline at 1-800-880-6788..
Temperature inversions that can trap exhaust gasses near the ground;
and a
Car idling in an open or closed attached garage, or near a home.
6
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Features and Operation (cont.)
Battery Installation/Replacement
Since batteries are not installed in the unit at the factory, you
will need to install them. Your Kidde unit will continue to
remind you to change the batteries for up to seven days after
low batteries are detected.
Test/Reset Button
The test/reset button is used to
test the unit’s electronics and to reset
the unit during alarm
Test/
Reset
Operate
WARNING: Your Kidde CO alarm will not be
operational and will not monitor for CO levels without
the installation of three charged AA batteries.
(see figure 3).
Figure 3
• Test the unit - To test,
press and release the test/reset button, you should
hear one short beep – followed by 5 seconds of
silence – followed by 4 short beeps with a
corresponding red LED flash. Familiarize yourself
and family members with the alarm pattern.
Test the unit weekly! If at any time your unit
does not perform as described replace it
immediately.
Your Kidde CO alarm monitors for battery failure such as
bad or corroded connections, sudden battery failure and
other causes. If the alarm senses any form of battery
failure, the unit will start chirping an audible alarm
every 30 seconds, the green and red alarm light will
flash.
The battery error warning will continue until new batter-
ies are placed in the unit, or until the remaining batteries
become completely exhausted.
Note: After the test/reset button is pressed, the alarm
sounds and the red alarm light flashes. This does not
indicate that carbon monoxide is present.
Three AA batteries have been included with your pur-
chase. When replacing the batteries, we recommend use of
the following for a minimum of one year normal operation:
Due to the loudness of the alarm we suggest you place your
fingers over the sounder opening when testing your Kidde CO
Alarm.
• Duracell MN1500 • Camelion Mignon LR6-AM3-1.5
• Energizer E91
• Rayovac LR6
• Reset the unit - If the alarm is sounding, pressing
the test/reset button will terminate the alarm. If
the CO condition that caused the alert in the first
place continues, the alarm will reactivate.
Reactivation times depend on the amount of CO
that caused the CO alarm to initially alarm and the
amount of CO present after resetting the alarm
(see page 11, Alarm Instructions/Emergency
Response).
These batteries can be purchased at your local retailer.
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
What To Do If The Alarm Sounds
Battery Installation/Replacement (cont.)
Battery Installation/Replacement Instructions
Carbon Monoxide Alarm Procedure
To install or replace the batteries in your Kidde unit please
perform the following steps:
WARNING: Actuation of the CO Alarm
indicates the presence of Carbon Monoxide
(CO) which can kill you.
1. Gently lift open
the battery cover to
expose the battery
Carbon Monoxide A
compartment.
TEST/
RESET
If alarm signal sounds 4 quick beeps, 5 seconds off:
OPERATE
M
r
a
l
A
2. Remove the old
batteries and
properly dispose
of them as
recommended by
the manufacturer (see figure 4).
1) Immediately move to fresh air - outdoors or by an
open door or window. Check that all persons are
accounted for. Do not re-enter the premises or
move away from the open door/window until
emergency services responders have arrived, the
premises have been aired out, and your alarm
remains in its normal operating condition.
Figure 4
3. Reinstall the new batteries, being careful to seat
the red battery warning flags in the recess of
the battery well. Also, note the polarity illustration
in the bottom of the battery compartment (see
figure 5).
2) Call your emergency local service
(fire deptartment or 911).
PHONE NUMBER
Never restart the source of a CO problem until it has
been corrected. Never ignore the sound of the alarm!
4. The unit will chirp and the green light will flash.
5. Gently close the battery cover. The battery cover
of your CO alarm will NOT close if all
three AA batteries are not installed.
Figure 5
9
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Alarm/Danger Levels
Alarm/Danger Levels (cont.)
Caution: This CO alarm will only indicate the presence of
CO at the sensor. CO may be present in other areas.
Concentration
of CO in Air
Approximate Inhalation Time
and Symptoms Developed
(ppm = parts
per million)
Mild Exposure: Headaches, running nose, sore eyes,
often described as “flu-like” symptoms.
The maximum allowable concentration for
continuous exposure for healthy adults in
any 8-hour period, according to OSHA*.
50 ppm
Medium Exposure: Dizziness, drowsiness, vomiting.
Slight headache, fatigue, dizziness, nausea
after 2-3 hours.
200 ppm
400 ppm
800 ppm
Extreme Exposure: Unconsciousness, brain damage,
death.
Frontal headaches within 1-2 hours, life
threatening after 3 hours.
Dizziness, nausea and convulsions within 45
minutes. Unconsciousness within 2 hours.
Death within 2-3 hours.
Familiarization with the effects of each level is important.
The symptoms described in the chart above are related to car-
bon monoxide poisoning and should be discussed with ALL
members of the household.
Headache, dizziness and nausea within 20
minutes. Death within 1 hour.
1,600 ppm
3,200 ppm
6,400 ppm
12,800 ppm
Exposure to high levels of carbon monoxide can be
fatal or cause permanent damage and disabilities.
Headache, dizziness and nausea within 5-10
minutes. Death within 25-30 minutes.
Headache, dizziness and nausea within 1-2
minutes. Death within 10-15 minutes.
Many victims of carbon monoxide poisoning indicate that
while they were aware that they were ill, they became so dis-
oriented and confused that they were unable to help them-
selves by exiting the building or calling for assistance. If you
experience any symptoms of carbon monoxide poisoning, con-
sult your doctor immediately! CO poisoning can be deter-
mined by a simple blood test called a carboxyhemoglobin test.
Severe cases may require treatment in a hyperbaric chamber.
Remember, young children and household pets may be the
first effected.
Death within 1-3 minutes.
* Occupational Safety and Health Administration
WARNING: The chart above relates to healthy adults. Levels dif-
fer for those at high risk. This product is intended for use in
ordinary indoor residential areas. It is not designed to measure
compliance with commercial and industrial standards.
This device is designed to protect individuals from acute effects
of carbon monoxide exposure. It will not fully safeguard indi-
viduals with specific medical conditions. If in doubt, consult a
medical practitioner. Individuals with medical problems may
consider using warning devices, which provide audible and visu-
al signals for carbon monoxide concentrations under 30 ppm.
If you have additional questions please call the Kidde
Consumer Hotline at 1-800-880-6788.
This CO alarm meets these alarm response times
At 70 PPM, the unit must alarm within 60-240 minutes
At 150 PPM, the unit must alarm within 10-50 minutes
At 400 PPM, the unit must alarm within 4-15 minutes
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Frequently Asked Questions
Caring for your Kidde
Battery Powered CO Alarm
Q.
How many CO alarms do I need in my house?
How much square footage will one CO alarm cover?
How to Care for Your Alarm
To keep your CO alarm in good working order, you must
follow these simple steps:
A.We recommend you place CO alarms near the sleeping
area(s). If you have a multi-level home, you should place a CO
alarm on each level of the home. A good rule of thumb for the
number and placement of CO alarms for your particular home is
to place CO alarms near smoke alarms that have been installed
to meet current building code requirements.
Generally, one CO alarm can be adequate for 1,200 to 1,500
square feet of living space. The most important determination for
the number of CO alarms needed is whether an alarm can be
heard in all sleeping areas.
•Test the alarm once a week by pressing the Test/Reset button
•Vacuum the alarm cover once a month to remove
accumulated dust. Use the soft brush attachment of your
vacuum cleaner, and unplug the alarm from the electrical outlet
before vacuuming.
•Instruct children never to touch, unplug or otherwise interfere
with the unit. Warn children of the dangers of CO poisoning.
•Never use detergents or solvents to clean the alarm.
Chemicals can permanently damage or temporarily contaminate
the sensor.
•Avoid spraying air fresheners, hair spray, paint or other
aerosols near the CO alarm.
•Do not paint the CO alarm. Paint will seal the vents and
interfere with proper sensor operation.
•Do not mount the CO alarm directly above or near a diaper
pail, as high amounts of methane gas can cause temporary
readings on the digital display.
Q.
A.Do I have to press the test button to get a CO reading?
No. Your Kidde CO alarm continuously monitors the air
for carbon monoxide. If it detects a dangerous level of CO it
will alarm automatically. To test the internal components and
circuitry of your CO alarm, press the test/reset button.
Wall Mounting Template
Note: If you will be staining or stripping wood floors or furniture,
painting, wall-papering, or using aerosols or adhesives for a do-it-
yourself project or hobby, before you begin: Remove the CO
alarm to a remote location to prevent possible damage to or
contamination of the sensor. You may wish to unplug the CO
alarm and store in a plastic bag during the project.
If you are going to mount your Kidde CO Alarm to the
wall, you may use this template for exact placement of the
two wall mount screws provided. For more information
about mounting to the wall, please refer to page 5.
The following is a list of substances that at high levels can affect
the sensor and cause temporary readings on the digital display
that are not carbon monoxide readings:
2.375"
Methane, propane, iso-butane, ethylene, ethanol, alcohol,
iso-propanol, benzene, toluene, ethyl acetate, hydrogen,
hydrogen sulfide, sulfur dioxides.
Also most aerosol sprays, alcohol based products, paints,
thinners, solvents, adhesives, hair sprays, after shaves,
perfumes, auto exhaust (cold start) and some cleaning agents.
13
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Limited Warranty
Product Specifications
WARRANTY COVERAGE: THE MANUFACTURER WARRANTS TO THE ORIGINAL
CONSUMER PURCHASER, THAT THIS ALARM WILL BE FREE OF DEFECTS IN
MATERIAL AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARS FROM
DATE OF PURCHASE. THE MANUFACTURER’S LIABILITY HEREUNDER IS LIM-
ITED TO REPLACEMENT OF THE PRODUCT, REPAIR OF THE PRODUCT OR
REPLACEMENT OF THE PRODUCT WITH REPAIRED PRODUCT AT THE DIS-
CRETION OF THE MANUFACTURER. THIS WARRANTY IS VOID IF THE PROD-
UCT HAS BEEN DAMAGED BY ACCIDENT, UNREASONABLE USE, NEGLECT,
TAMPERING OR OTHER CAUSES NOT ARISING FROM DEFECTS IN MATERIAL
OR WORKMANSHIP. THIS WARRANTY EXTENDS TO THE ORIGINAL CON-
SUMER PURCHASER OF THE PRODUCT ONLY.
Power:
Three AA batteries (supplied)
Sensor:
Electrochemical carbon monoxide
sensor
Temperature:
Mounting:
Alarm:
Operating range 4.4°C (40°F) to
37.8°C (100°F)
Accessories supplied for wall
mounting
85+ dB at 10' @ 3.4 0.5 KHz
pulsing alarm
Warranty Disclaimers: Any implied warranties arising out of this sale, including but
not limited to the implied warranties of description, merchantability and fitness for
a particular purpose, are limited in duration to the above warranty period. In no
event shall the Manufacturer be liable for loss of use of this product or for any indi-
rect, special, incidental or consequential damages, or costs, or expenses incurred
by the consumer or any other user of this product, whether due to a breach of con-
tract, negligence, strict liability in tort or otherwise. The Manufacturer shall have no
liability for any personal injury, property damage or any special, incidental, contin-
gent or consequential damage of any kind resulting from gas leakage, fire or explo-
sion.
LED Operation:
•Flashing green LED every 30 seconds
indicates proper operation
•4 pulsing red LED with 4 quick alarm
chirps indicates presence of CO
Battery
Replacement:
Red and green LED flashes, and the
unit chirps every 30 seconds. Replace
the three AA batteries with one of the
following brands.
• Duracell MN1500
• Energizer E91
Some states/ provinces do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
Some states/ provinces do not allow the exclusion or limitation of consequential or
incidental damages, so the above limitations or exclusions may not apply to you.
Legal Remedies: This warranty gives you specific legal rights and you may also have
other rights that vary from state to state/ province to province.
• Camelion Mignon LR6-AM3-1.5
• Rayovac LR6
Warranty Performance: During the above warranty period, your product will be
replaced with a comparable product if the defective product is returned, postage
prepaid, to KIDDE / Pyrene Corp., Customer Service Dept., 130 Esna Park Drive,
Markham, ON, L3R 1E3, together with proof of purchase date. Please include a note
describing the problem when you return the unit. The replacement product will be
in warranty for the remainder of the original warranty period or for six months,
whichever is longer. Other than the cost of postage, no charge will be made for
replacement of the defective product.
Unit Malfunction: Red light flashes, and the unit chirps
every 30 seconds indicates a unit error.
Refer to page 7.
Test/Reset Button: Test button verifies proper unit
operation.
Size & Weight:
Warranty:
5.5' diameter x 1.4' depth/0.66 lbs.
with batteries
Kidde makes no warranty, express or implied, written or oral, including that of mer-
chantability or fitness for any particular purpose, with respect to the battery.
The above warranty may not be altered except in writing signed by both parties
hereto.
Five-year limited warranty from date of
purchase against defects in material
and workmanship on CO Alarm unit.
16
15